Primary-Secondary Chilled Water Systems | HVAC Chilled Water Distribution System | HVAC World

Поделиться
HTML-код
  • Опубликовано: 15 май 2020
  • Hell guys!!
    HVAC se related choti SE choti problem ki video ham bana KR upload krte rhte jisse apko HVAC ki knowledge milti rahe
    so plz
    LIKE | COMMENT | SHARE | SUBS C R I B E
    Keep Sharing - And Subscribe For More Updates...
    THANK YOU.

Комментарии • 141

  • @HVACWorld
    @HVACWorld  4 года назад +9

    Let's have 100 likes for this video

  • @abhilashac3988
    @abhilashac3988 2 месяца назад +1

    Very good👍👍

  • @tinkurajrajsingh8589
    @tinkurajrajsingh8589 3 месяца назад +1

    Nice sir

  • @mdshahbazgaddi5319
    @mdshahbazgaddi5319 3 месяца назад

    Very nice explain thanks

  • @amarjeetbadhan9593
    @amarjeetbadhan9593 2 года назад +1

    Very very knowledgeable video. 🙏🙇

  • @prakashbaby9189
    @prakashbaby9189 5 месяцев назад

    Nice explanation

  • @hvacshailendarshahganjup9464
    @hvacshailendarshahganjup9464 2 месяца назад

    Good 👍

  • @shahikhan5637
    @shahikhan5637 3 года назад +1

    Bahut achcha samjhaya aap ne

  • @guddumishra5655
    @guddumishra5655 2 года назад +1

    Very good explain boss lot's thanks

  • @jarugumallipavankumar7161
    @jarugumallipavankumar7161 Год назад

    Very good explain sir thank you.....

  • @RAVIKUMAR-hd1gk
    @RAVIKUMAR-hd1gk 10 месяцев назад +1

    Bahut khub sir excellent

  • @muhammadjamilfaiz1173
    @muhammadjamilfaiz1173 Год назад +1

    Very nice informations.

  • @krishnarajsaradha8653
    @krishnarajsaradha8653 2 года назад +1

    Very good explain thank-you sir

  • @akhtarreyaz376
    @akhtarreyaz376 Год назад +1

    Meaning content

  • @mdmohi5635
    @mdmohi5635 7 месяцев назад +1

    Best explanation ❤

    • @HVACWorld
      @HVACWorld  7 месяцев назад

      Glad you think so!

  • @kumarsong855
    @kumarsong855 3 года назад +1

    Very nice Information... your explanation way is very Good

  • @A.AHAD123
    @A.AHAD123 3 года назад

    awesome information

  • @Samshiralam
    @Samshiralam 3 года назад +1

    Sir acche se explain krte ho, main abhi kuch din pahle hi aapke chanel pe aaya hu, or mujhe acchi knowledge mili hai

  • @sharanupujar5462
    @sharanupujar5462 2 года назад +1

    Thank u so much sir.... Really I loved it.... thanx alot

  • @mdaafanhasan2651
    @mdaafanhasan2651 4 года назад +1

    Awsome

  • @alok0734
    @alok0734 2 года назад +1

    Thank you for eloborating so clear and in simple words. Appreciate your efforts, keep doing good work.

  • @ssraorao7565
    @ssraorao7565 3 года назад +1

    Thank you very much sir now i am got secondary pipe line and primary pipe line bypass valve (decouple)🙏

  • @skbarua7677
    @skbarua7677 3 года назад

    Wow...great....thanks dear

  • @VikasSingh-sq8pk
    @VikasSingh-sq8pk 3 года назад

    Excellent explain sir

  • @rezashahid7768
    @rezashahid7768 4 года назад +1

    Excellent sir ji

  • @ankitpathade7023
    @ankitpathade7023 3 года назад +1

    Excellent explanations sir

  • @afrozroushan5194
    @afrozroushan5194 3 года назад

    Zbrdst bro ultimate appko professor hona chahye goood knowlage

  • @ASADKHAN-xb3vn
    @ASADKHAN-xb3vn 3 года назад

    Great Sir

  • @singhsingh-ip1sc
    @singhsingh-ip1sc 3 года назад

    Nice video

  • @golamnur989
    @golamnur989 3 года назад +1

    I have been following your channel from quite long time. Every video is very informative. I am benefited alot from your video. My humble request make a video on
    1. Chemical dosing (matual and automatic)
    2. Chilled water pressurisation unit
    3. Chilled water line flushing (most needed).

  • @saimathecalligrapher
    @saimathecalligrapher Год назад +1

    Love you sir

  • @usmankhalid1806
    @usmankhalid1806 3 года назад +1

    Sir agar load 100% acheive ho geya hai or 100gpm 44 F water secondary pump k through chala geya or 100gpm 44 F decoupler line se primary motor mai a geya than ye 100gpm with 44F and return se 100gpm with 56F mill ke low delta T nahi ho jeya ga?

  • @joydipghosh3273
    @joydipghosh3273 2 года назад +3

    What is the process of calculation of de-coupler pipe size???

    • @KashifKhan-rd8ts
      @KashifKhan-rd8ts 2 года назад

      Ek size chota le kr connect kr do, part load pe chiller run karega, kabhi bhi 100% water to return lena nhi hai decoupler se.

    • @javeedhvactechnician7760
      @javeedhvactechnician7760 8 месяцев назад

      ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=gvbqOfQpDHeg804C

  • @alamroushan9351
    @alamroushan9351 2 года назад +1

    Chlir or cling tawor ka keya cantion rahta hai plz Ripley

  • @usmanahmed8842
    @usmanahmed8842 4 года назад +2

    Sir first question k reply k liay thanks clear ho gya he, mera second question ye he k Ap nay jasy btya k off load pay jo return air ay gi us ka temperature b 56 rhy ga lakin jo water by pass ho raha he secondary pump say us ka temperature tu 44 hi rhy ga, is terha jb AHU ka retrurn Aur by pass ka water mily ga tu temperature 56 say km ho ker 50 nhi ho jay ga same constant volume system ki terha?

    • @HVACWorld
      @HVACWorld  4 года назад +2

      Video me maine explain kiya h k part load pe hmara 3 chiller me se 1 chiller off ho jayega or uske sath sath 1 primary pump v off ho jayega...jaise hi primary pump off hoga us case me bhut hi come amount me CHW bypass hoga jisse CHWR k temperature me bhut minutes difference ayega jiski wajah se baaki ke 2 chiller unload hone shuru jayege jisse k hmari power consumption come ho jayegi..ek chiz mai or add krna chahunga k primary-secondary system me secondary pump ka water flow maximum case me primary pump se zyada hota hai, kyu ke building me bhut sare equipments hote h to secondary loop me zyada GPM chahiye hota hai..isliye water bhut kam amount me bypass hota hai...

    • @usmanahmed8842
      @usmanahmed8842 4 года назад +1

      HVAC World thank you sir for your explanation

  • @MohdJaved-oq8bn
    @MohdJaved-oq8bn 3 года назад +2

    Sir bms systems ke bare m bataiye

  • @sunnymodi9393
    @sunnymodi9393 2 года назад

    DP sensors & Temp sensors are liittle bit tricky & technical, explained well though

  • @muhammadswalih5989
    @muhammadswalih5989 7 месяцев назад +1

    Why Ur installing modulating valve at the chiller outlet, on off valve is enough

    • @HVACWorld
      @HVACWorld  7 месяцев назад

      It is on/ Off type

  • @abhijitpalai6540
    @abhijitpalai6540 Год назад

    Sir achutor kese manual open close karte hai ek bar bataye plz video me🙏🙏🙏

  • @ranazubairkhalid9447
    @ranazubairkhalid9447 11 месяцев назад

    Love you bro

  • @usmanahmed8842
    @usmanahmed8842 4 года назад +1

    Sir Ap nay jis terha video me kaha k jb aik AHU ka 2 way valve close ho ga tu dosry AHU ka b 2 way valve close ho jay ga Aur load kam ho jay ga but mera question ye he k her aik floor ki apni cooling requirement hoti he suppose AHU #1 pay load km hota he tu lazmi tu nhi he k baki AHU ka load b km ho?

    • @HVACWorld
      @HVACWorld  4 года назад +1

      Mere kahne ka mtlab hai k jaise jaise floor pe temperature achieve hota jayega waise waise us AHU ka 2-way valve usi ratio me band hota jayega or jisse k ahu k accross water flow kam hota jayega or wo water Bypass line se cross ho kr primary me chala jayega....aisa ko rule nhi h k at a time sare ahu ka valve band hoga..ye understood hai k valve tab band hoga jab room ya floor ka temperature achieve hoga.....I hope ab aapko clear ho gaya hoga... comment kr ke confirm zarur krna.. thank you

    • @usmanahmed8842
      @usmanahmed8842 4 года назад

      HVAC World G thanks

  • @usmankhalid1806
    @usmankhalid1806 3 года назад

    And sir zaroori nahi k har floor pe aik aik Ahu hon or hum pd sensor top pe lagaty hyn but design requirment agr ahus aik floor pr 2 ya 3 bhi hotay hyn or remaining floor pr 1 ya 2 to dp sensor kahan adjust kerte hyn than how it works out?

  • @johnphilip7084
    @johnphilip7084 Год назад +1

    dps which line it be placed,as there is 2 rises supply return.which floor it be placed if it is 6 floor building,

    • @HVACWorld
      @HVACWorld  Год назад

      DPS has two ports, one portt will be connected to Supply line and other one will be connected with Return line to get the pressure difference between supply and return line

  • @jai.shree.Ram-sena108
    @jai.shree.Ram-sena108 3 месяца назад

    Primary pumb kaha laga hota hai aur secdary pumb plz answer

  • @suru7593
    @suru7593 Год назад +1

    Would it be possible to create the chiller selection for various applications, such as commercial and residential, as well?

  • @TAHIRHUSSAINMEPINDUSTRY
    @TAHIRHUSSAINMEPINDUSTRY 3 года назад +1

    excellent video, u said PDS will be installed at high level, why? might i will got required temperature at low level floor, 2ndly if i have industry and all AHU,s will be on one roof horizontally, where i have to install PDS?

    • @KashifKhan-rd8ts
      @KashifKhan-rd8ts 2 года назад

      Hi, I think we receive the highest pressure at the last ahu either in case of vertically placed or in horizontal placed AHUs, that's why we are installing PDS there.

    • @javeedhvactechnician7760
      @javeedhvactechnician7760 8 месяцев назад

      ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=gvbqOfQpDHeg804C

  • @nishantsh03
    @nishantsh03 3 года назад

    Hot well and cold well kya hotabhai sir... Or hot well se connect kya hota hai primary pump or secondary pump

  • @abdulraqeeb6514
    @abdulraqeeb6514 Год назад

    Excellent very informative , just tell me what is roll of thermoste in the room , and it is linked to return air sensor ? Please.

  • @4umahin
    @4umahin 2 года назад

    Good explanation...but what will happen if in case valves of secondary pump circuit are closed and PP is still running? Like, is it possible if there may be no secondary pump?

  • @alishnawa1108
    @alishnawa1108 2 года назад +2

    Is there any English Version for ur valuable lectures ?

  • @meesamkazmi0512
    @meesamkazmi0512 3 года назад +1

    Sir jb load km hoga decopler line mai jayega to kya secondary pupm ki frequency km hogi ya same speed pe chalega

    • @HVACWorld
      @HVACWorld  3 года назад +1

      Secondary pump ki frequency kam ho jayegi jisaki wjh se secondary pump ka RPM kam hoga or water flow v kam ho jayega jo energy saving ka sabse bada reason h

    • @meesamkazmi0512
      @meesamkazmi0512 3 года назад +1

      @@HVACWorld sir agr water flow km hoga to primary pump k liye bhi water suction km hoga kya

    • @HVACWorld
      @HVACWorld  3 года назад +2

      Nahi...wo decoupler line se water suck kr lega

    • @meesamkazmi0512
      @meesamkazmi0512 3 года назад +1

      Ok thnku sir

  • @thepurposeofmyexistence2511
    @thepurposeofmyexistence2511 3 года назад

    Dear sir, i could not get one point , why allways we put the 2way valve or picv valve on the outlet of the ahu or fcu , can we put it on inlet of fcu/ ahu , and put actuator which operate on temp sensor of return air , if room temp achived then it will close the supply valve to fcu , which is same as if we put picv down stream the fcu

  • @mdwaquaruddin165
    @mdwaquaruddin165 Год назад

    In vpf system where the water goes when system is return at part load

  • @mohammadrahman7597
    @mohammadrahman7597 2 месяца назад

    Is it possible to get a ladder diagram

  • @masterchef6694
    @masterchef6694 2 года назад

    Can we have 2 sets (arrays) of pumps in the secondary side? (If there are 2 different types of loads with very different pressure drops)

  • @kashifiqbalzafar
    @kashifiqbalzafar 4 года назад +1

    Sorry sir , I missed your live session today.
    Excellent explanation..

    • @HVACWorld
      @HVACWorld  4 года назад +1

      No problem... thanks

  • @hamzabadar3386
    @hamzabadar3386 Год назад +1

    Hmra jo primary pump ha wo b vfd sa control hota ha.. sir.

  • @AshrafKhan-xu4wk
    @AshrafKhan-xu4wk 4 года назад +1

    Sir apna 2 chiller 200tr
    iska GPM 800 hua but mera questions ye hi ki sir building ka load 50 percent hua toh vsd pump slow hua ab building ko 400gpm chahiye ye decopler line h vsd pump ke inlet and primary pump ke inlet se connect h sir ye samjh nhi aa raha h apna primary pump constent h ye depcopler se 800gpm le lega building 400gpm nhi ja payega sir depouler par automatic valve hona chahiye ki building ka 50 percent load ho toh decoupler valve se 50 percent water bypass ho

    • @HVACWorld
      @HVACWorld  4 года назад +1

      Good observation...jab building 50 prcnt pe operate hogi to schematic k according usko 600 GPM chahiye hoga or hamara primary pump 800 GPM delivered krega jisse decoupler se 200 GPM by pass hoga..ek point maine add nhi kiya jo mai add krna chahunga... primary-secondary system me secondary loop me zyada GPM building ko delivered krta hai maximum cases me...agar aap kisi v site pe jao waha dekhna building ka load zyada hoga to secondary pump ka flow rate primary se zyada hota hai to is case me building ko v zyada GMP chahiye hota hai kyu k bhut sare AHU hote hai..to us case me thoda paani bypass hota hai.... decoupler line pe automatic valve nahi lagate hai pani ka flow pump k pressure drop k according hota hai

    • @AshrafKhan-xu4wk
      @AshrafKhan-xu4wk 4 года назад +1

      @@HVACWorld sir chiller opreating kaise karte h bata dijiye step by step

    • @HVACWorld
      @HVACWorld  4 года назад

      Video mil jayegi apko....I hope apka doubt clear ho gaya hoga.... primary pump ka pura paani decoupler se suck nhi krega kyu k secondary pump v running condition me hai to wo v paani suck krega or aage building me bhejega... decoupler is chiz ko mind me rakh kr kiya jata hai uske bich ka pressure drop is trh se design kiya jata h k pura paani wapis se primary pump me na aye....

    • @AshrafKhan-xu4wk
      @AshrafKhan-xu4wk 4 года назад +1

      @@HVACWorld sir doubt clear ho gaya

    • @HVACWorld
      @HVACWorld  4 года назад

      Thanks

  • @mdsadabalam9434
    @mdsadabalam9434 3 года назад +1

    Sir DPT return ka pressure kaise sense karta hai wo to supply me laga hai

    • @HVACWorld
      @HVACWorld  3 года назад

      I will explain you in video

    • @mdsadabalam9434
      @mdsadabalam9434 3 года назад +1

      Thanks sir Actually,My course is about to finish on 30August,If you can explain before 30 August I will be grateful for you.Thanks

    • @HVACWorld
      @HVACWorld  3 года назад

      30 August se pahle video mil jayegi with practical demonstration

    • @mdsadabalam9434
      @mdsadabalam9434 3 года назад +1

      Thanks sir❤️

  • @RahulKumar-yy2jg
    @RahulKumar-yy2jg 3 года назад +1

    K3 metalizer kae bar me kuchh batai sir ji apana number dijiye

  • @MANISHYADAV-kc7jm
    @MANISHYADAV-kc7jm 4 года назад

    ye balancing valve Q lga rhe hai two way valve ke baad .iska kya opration hai

  • @ArifKhan-nh8xd
    @ArifKhan-nh8xd Год назад

    Sir can you explain me how we calculate GPM

  • @chiragbari7680
    @chiragbari7680 3 года назад

    Need to primary and secondary pump commissioning video upload (Mumbai)

  • @johnphilip7084
    @johnphilip7084 Год назад +1

    dps be placed in which line as there is both supply and return line,for example 6floor building which floor it be placed.can i have ur mail id i have some doubt to learn can u help me out.

    • @HVACWorld
      @HVACWorld  Год назад +1

      If 6th floor is your furthest point, Install it on 6th floor

    • @HVACWorld
      @HVACWorld  Год назад

      *5th floor

    • @johnphilip7084
      @johnphilip7084 Год назад

      @@HVACWorld dps is placed in which line as there is 2 lines supply and return

  • @dilawarkhan4838
    @dilawarkhan4838 Год назад

    Bhai to is system Mai bypass open hi rkhna hota hai

  • @subhashvasava6540
    @subhashvasava6540 3 года назад +1

    Humidity temperature KV Ritesh Himalaya temperature Ben 10

  • @mdsuhailansari485
    @mdsuhailansari485 Год назад +1

    600 tr ka ek hi chiller ho sakta hai kya?

  • @tinkurajrajsingh8589
    @tinkurajrajsingh8589 3 месяца назад +1

    Sir ji mujhe HVAC se koi diploma karna hai kon sa karu

    • @HVACWorld
      @HVACWorld  3 месяца назад

      HVAC in diploma nahi hota hai.... Diploma in Refrigeration and air conditioning se hota hai

  • @DilshadAhmad-mw3yc
    @DilshadAhmad-mw3yc 3 года назад +1

    Sir ji vfd se load kam kyu ho raha hai
    Pahle 100 % me chal raha tha abhi 40% me chal raha hai kyu

    • @HVACWorld
      @HVACWorld  3 года назад

      100% kab to or 40% kab hua???

  • @DilshadAhmad-mw3yc
    @DilshadAhmad-mw3yc 3 года назад +1

    Hello sir

  • @9889008366
    @9889008366 2 года назад

    Confusing.

  • @usmankhalid1806
    @usmankhalid1806 3 года назад

    Please explain.. lot of respects Stay blessed
    Sir i want your email id please if you feel easy. Because your channel have made my interest in HVAC.

  • @mepmep5682
    @mepmep5682 2 года назад +1

    100 TR ka AHU 😂

    • @HVACWorld
      @HVACWorld  2 года назад

      Isse zyada TR ka hota h

  • @a.m347
    @a.m347 Год назад

    English please 😢

  • @dil_ipkumar
    @dil_ipkumar 2 года назад

    Bhai VFD Hota hai VSD Nahi to hai yaar correction kijiye pahle vedio ko

    • @trick-tech6623
      @trick-tech6623 Месяц назад +1

      Vfd means variable frequency drive
      Vsd means variable speed drive.
      Bro plz enhance your knowledge before blaming someone.

    • @HVACWorld
      @HVACWorld  Месяц назад

      @trick-tech6623 zyada gyani ban jate ho. VFD or VSD k bare me ye video nahi h....ye Video piping system k bare me jisme pump ki speed vary karti h. Speed vary karne k liye VFD or VSD dono ka use Kiya jata h kyu dono ka kaam ek hi hai. Agar VFD k bare me janna hai to dusri video dekh lo.

  • @usmankhalid1806
    @usmankhalid1806 3 года назад

    And sir zaroori nahi k har floor pe aik aik Ahu hon or hum pd sensor top pe lagaty hyn but design requirment agr ahus aik floor pr 2 ya 3 bhi hotay hyn or remaining floor pr 1 ya 2 to dp sensor kahan adjust kerte hyn than how it works out?