  • @baiamontes
    @baiamontes Год назад +3

    Hello Mate, nice job you do, I really wish you live in UK ! I got faulty Growatt and Can’t find anyone who can repair it, all the Best and thanks for sharing your expertise with us.

  • @crymeforeverlo3402
    @crymeforeverlo3402 Год назад +2

    شغل احترافي ومرتب.بارك الله بجهودك..thanks for sharing this helpful information 👍

  • @BeastMovies
    @BeastMovies Год назад

    Thanks. I have this problem. I wish there was someone like you that lived in Australia. You make it look so easy with your years of experience.

    • @JustaCuriousity
      @JustaCuriousity Год назад +1

      How long have you used spf5000es? Im planning on using it but afraid of the electronics 😞

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад +1

      Try voltronic power inverters

    • @Rexsitudio-WarcraftRumble
      @Rexsitudio-WarcraftRumble Год назад +1

      @@JustaCuriousity dont use it, it is garbage. i am distributor, currently having so many factory fault issues from this model

    • @YunaOgura-mx3ob
      @YunaOgura-mx3ob 5 месяцев назад

      ​@@Rexsitudio-WarcraftRumbleWhich Chinese brand you recommend?

  • @chasif4029
    @chasif4029 Год назад +3

    Very nice sir your good work

  • @User_987dfg
    @User_987dfg Год назад +3

    Good work sir nice video

  • @muhebullahdurrani6086
    @muhebullahdurrani6086 Год назад +2

    Nice video sir thanks very long time you upload the video

  • @coreyellisart6877
    @coreyellisart6877 3 месяца назад

    I am hoping I can get a response install 3 of these inverters ran 58 volts DC to them battery side did not have solar hooked up or grid hooked up as soon as I closed the switch on the batteries I blew the exact same igbt I also pre-charged the system with an inline resistor
    I'm repairing the igbt now and I'm very hesitant to hook the batteries back up the company growatt is giving me the runaround that's why I am fixing it myself I asked them what the max voltage was on the battery side they could not answer I am using lithium ion why would hooking up the batteries below this igbt?

  • @FourInTehMorning
    @FourInTehMorning 3 месяца назад

    Hi, I had a different issue where ZD1 zener in MPPT board burned out, can you tell what to replace it with?

  • @julianorchard6129
    @julianorchard6129 Год назад +1

    Hi ar you able to tell me what diodes and voltages are fitted to d20 and d24 i cant see it in the video

  • @miahmbewe2754
    @miahmbewe2754 Год назад +1

    Thanks brother. We are appreciate your hard work and good heart

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад

      Thank you..realy a lot of thanks

    • @julianorchard6129
      @julianorchard6129 Год назад +1

      ​@ALayoubiMaintenanceCenter hi I've become a paid subscription but can't see how to message you could you let me know what diodes including voltages go into my growatt inverter spf 5000es the info I'm asking for is about diodes zd020 and zd024 thanks

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад +2

      @julianorchard6129
      Please now you can contact us via whatsapp nomber
      You can find nomber in joining page

    • @julianorchard6129
      @julianorchard6129 Год назад

      ​@@ALayoubiMaintenanceCenter I have WhatsApp you thanks

  • @baiamontes
    @baiamontes 8 месяцев назад

    Hi
    I admire your job sharing for long time it helps me to solve many problems, I watched all your videos more than one time each, but now I got a problem that I can’t solve it not turning on with battery only I need to supply ac in them it starts Growatt SPF 3500 ES please give a hint where I should looking for problems.

  • @nivinenivine4101
    @nivinenivine4101 Год назад +1

    يعطيك العافية شغل ممتاز . من اين نشتري الاغراض اذا انت موجود في لبنان الترانزيستورات موجودين لاكن الاوبتوكابلار كلا هل يوجد رقم بديل شكرا

  • @خالدمحمود-ق8ث
    @خالدمحمود-ق8ث Год назад +2

    شكرا استاذ عمل متميز وفيه الفائدة

  • @tunas66
    @tunas66 Год назад +1

    What do you charge to repair a growatt 5000 a spark came out of the right side and just shut down?

  • @mrseharris
    @mrseharris Год назад +1

    trying to set up an offgrid solar system in nevada, USA
    having fault code 58 on sungold 5000 watt inverter.. do u know how to fix that?

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад

      You are welcome
      Please if you can join our channel
      To get whatsapp nomber
      And contact our technical team

  • @chienthanlienminh
    @chienthanlienminh Год назад

    How is the quality of sako inverter compared to other inverters?

  • @vctech4954
    @vctech4954 6 месяцев назад

    ❤ nice job...What is buck convertor work in pcb?

  • @YTiNgraM
    @YTiNgraM Год назад +1

    Have u ever repaired volt polska ?

  • @kawsermahmud4828
    @kawsermahmud4828 Год назад +1

    Sir con campani invter vol growatt and crown inverter konta valo

  • @jessew6757
    @jessew6757 Год назад +1

    Hi Alayoubi. I have watched your hybrid inverter repair video and it seems the Growatt circuit is almost similar to MUST PH1800 hybrid inverter.
    Now we have an PH1800 5Kw that has developed a problem this week. This inverter has been in operation since mid year 2020. All three LED
    Lights are blinking alternately continuously. The Inverter is stuck at the screen showing 48v and 5.0kw.
    What could have failed inside ?
    Regards, Jesse.

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад

      Hello dear friend
      Please if you can join our channel
      To contact us via whatsapp
      And to send some photos and video to can help you

    • @jessew6757
      @jessew6757 Год назад

      @@ALayoubiMaintenanceCenter Hi.....I’ve since managed to find the problem on the power circuit board. There are two small electrolytic capacitors that had severely deteriorated in their microfarad values. One was testing 131 microfarads instead of its rated 1000microfarads. The other one was testing 54 microfarads instead of 100 microfarads. All power Mosfets tested ok and no problems. Resistors around the power areas also tested ok. So I proceeded and replaced only the two capacitors, and reassembled the inverter yesterday. I powered it up and it booted up normal. Today as I write, I’m doing a extended run testing to see if everything is ok. Thank you....
      Question: Is “joining” your channel the same as the regular RUclips “subscribing” ?
      Regards,
      Jesse

  • @Qaiserhayatkhan
    @Qaiserhayatkhan Год назад +2

    Very nice

  • @pcmultimedia1
    @pcmultimedia1 Год назад

    Is there a place online where we can get the complete circuit diagram of the sp5000es . So we can check components and test.
    I have two of these in operation , I’m capable of repairing these. I’ve just got a few new fans just in case. Th e fan run up when loads is on but do quieten download at night when there is little load, so I got some just in case they fail and give a 01 error.

  • @npi_solutions282
    @npi_solutions282 Год назад

    Nice vedio thanks for sharing knowledge

  • @Alliegish
    @Alliegish Год назад +1

    Assalamualaikum, I am out in South Africa, and I have a Code 2-over heating error, there is nothing wrong with the temperature. The moisture started messing with the MPPT board. Is there a way to temporarily bypass this code until i get money to get new board or get this one fix. shukran

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад

      Did you check filters?
      And check the place
      You must have about 25cm free space round the inverter

    • @Alliegish
      @Alliegish Год назад +1

      slm, all checks mentioned are ok, unit not overheating, the CN2 connection picked some moisture damage, is there anyway of bypassing until i get it fixed, i can send you picture if you send me your email address. shukran

  • @janathrscnw
    @janathrscnw Год назад +1

    do you have any repair work for error code 02 on Growatt SPF5000ES model

  • @wisamaljanabi1959
    @wisamaljanabi1959 Год назад

    can you please do a video about repair of fault 08

  • @STACKHOUSE25ify
    @STACKHOUSE25ify Год назад +2

    Hello AL ayoubi, I'm from Brazil, I have a Growatt spf 5000ES inverter, it turns on but it doesn't charge the battery through the photovoltaic panels, it only charges through the AC, I've already checked the MPPT and the main board, it seems ok, could you help me with these repair conditions. I am a member of your RUclips channel, I WILL BE VERY THANKFUL FOR YOUR ATTENTION.

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад

      You are welcome dear friend
      Now you are joining our channel
      Please check our whatsapp nomber in joining page
      To contact us
      So you can send photos or video to tell you how you can fix it💐💐

    • @YunaOgura-mx3ob
      @YunaOgura-mx3ob 3 месяца назад

      After how many months you got problem in growatt?

  • @pvteksolarenergy
    @pvteksolarenergy Год назад

    I want to learn how to diagnose and identify the faulty ic

  • @pcoa7183
    @pcoa7183 5 месяцев назад

    Because of what Growatt SPF 5000 ES: Fault code 08 ?

  • @mbpowersalutionkasur1889
    @mbpowersalutionkasur1889 Год назад

    Nice work

  • @mattikhan5478
    @mattikhan5478 Год назад +1

    hello sir how are you sir my question is how the fault solve the fault vode 57 the 5 kw inverter vm2 model fronous the board what side check the 57 fault is solve plz guide me

  • @ruwankumara6226
    @ruwankumara6226 4 месяца назад

    Great

  • @القناعةغايتي
    @القناعةغايتي Год назад

    كيف الاجهزه موديل mps -h 3.5kw

  • @arielbertinatti2791
    @arielbertinatti2791 Год назад +1

    Hi i have fault 08 error , please help

  • @teutonman7018
    @teutonman7018 Год назад +1

    Does anybody know what causes fault code 9?

    • @ALayoubiMaintenanceCenter
      @ALayoubiMaintenanceCenter  Год назад +1

      There are many reasons
      May be
      An onverload when the battery voltage drops
      Short on inverter output
      Weak batteries..

    • @teutonman7018
      @teutonman7018 Год назад +1

      @@ALayoubiMaintenanceCenter Thank you for replying.

  • @apachecomm
    @apachecomm Год назад +2

    thank you master, but you don't reply to messages, it's sad.

  • @dibeerwolf1645
    @dibeerwolf1645 Год назад

    ask yourself: if the SPF5000es is connected via AC output and via AC input and the following conditions apply: all consumers are off, the battery is already 100% charged, i.e. fully charged, and there is full sun on the PV modules at 12:00 p.m.: what happens to the EXCESS electricity from the PV system then ? (does it flow back into the public grid via AC output or AC input?) thank you

    • @MuzzleloaderPoland
      @MuzzleloaderPoland 11 месяцев назад

      There is No excess, inverter just don’t take power from pv

  • @AbdulRasheed18587
    @AbdulRasheed18587 7 месяцев назад

  • @ruwankumara6226
    @ruwankumara6226 4 месяца назад

    Hello I have many problems with this inverter and I have 10 unit error 9, error 08, error 02

  • @GhannysXatzhdakhs
    @GhannysXatzhdakhs 6 месяцев назад

    👋👋👋👋👌

  • @mdmojibor1859
    @mdmojibor1859 Год назад

    growatt solar inverter fault 53 servicing

  • @guidomercera7647
    @guidomercera7647 4 месяца назад

    can i have your email i want to fly you over to do some repair and to teach me trobleshooting

  • @stevenbliss989
    @stevenbliss989 Год назад

    Would love to know what the switching frequency of the main transformer is, because to me it look WAY TOO SMALL for 5KW, and the only way around that is exotic transformer running at 200kHz+ frequency???????????????????????????????????????????????????