Underfloor heating system fully fitted ready for screeding

Поделиться
HTML-код
  • Опубликовано: 15 апр 2023
  • Underfloor Heating for the garden room, this video explains the full fitting process for wet underfloor heating from the fitting of the membrane and edge expansion to laying the clip track and piping up the circuits and final connection to the manifold
    I have been fitting Underfloor heating in every project for the last 20 years and have always used Nu-Heat Underfloor Heating and renewables to design and supply the systems, quality products, excellent planning and specification and lifetime technical support is a real asset in a building project
    More information about Nu-Heat click here geni.us/Nu-Heat
    Like the Video? Maybe buy me a coffee!!
    click the link here geni.us/vn0mp
    For my 76mm and 102mm hinge jigs click here geni.us/fvGT
    My Amazon store for all kinds of goodies (PAID LINK)
    CLICK HERE geni.us/LgI3n6
    Music by www.bensound.com
  • ХоббиХобби

Комментарии • 55

  • @davidianwalsh
    @davidianwalsh Год назад +15

    i built my own place in 2011-2013 using NU-Heat UFH throughout (330m2) - I've never had any issues at all! I couldn't recommend them highly enough. I integrated a MVHR system, and thermal solar panels as well. It's such a great idea to invest as much as you can in trying to future proof your home if the intent is for it to be your 'forever' home.

    • @lukepeacham9663
      @lukepeacham9663 Год назад +1

      Do you have gas? How do you get hot water.

    • @davidianwalsh
      @davidianwalsh Год назад +1

      @@lukepeacham9663 no mains gas, I initially installed an electric boiler to top-up the solar panels, but that proved too expensive so I’ve got an external oil fired boiler now. Also back in 2011 when the initial feed-in tariff was available I installing 2.4kw of solar panels, they have already more than paid for themselves and I have 13 years of payments still to come!

    • @tonyradice1494
      @tonyradice1494 11 месяцев назад

      Can I ask who you used for MVHR ? I’m also about to do the same thing next spring, UFH throughout, MVHR, and solar. Many thanks in advance.

  • @samposton9101
    @samposton9101 Год назад +7

    Super neat work, Robin & Gary. Lovely seeing so much care and pride in something that’ll never be seen!

  • @jamiefors5062
    @jamiefors5062 Год назад +2

    Love old school tradesman like Gary, top fella 👍

  • @PeteBrisbourne
    @PeteBrisbourne Год назад +4

    Absolutely envious of all this excellent build quality and infrastructure.

  • @philipwilliams8114
    @philipwilliams8114 Год назад +1

    Great segment with Gary. A star is born 👍

    • @ukconstruction
      @ukconstruction  Год назад +2

      He's an amazing guy and good friend and super brave to be featured, he has been creating amazing work for me for decades!! I'm super lucky to have him in my team!

  • @conorlavery4762
    @conorlavery4762 Год назад +1

    Hey Robin........ Nice wee Sunday morning break required now...... perfect timing...... cheers

  • @Anthony-dh3ty
    @Anthony-dh3ty Год назад +3

    You should be running your ufh on weather compensation not using a crap manifold mixing valve you could run that room at 30c flow temperature

  • @alicocker3256
    @alicocker3256 11 месяцев назад

    Came back to this video as I’m just about to membrane over PIR prior to running clip track and pipe work for UFH and as per usual the work here is exceptional, also the details are covered sand all my questions were answered!! Cheers

  • @marcmcgettigan3580
    @marcmcgettigan3580 Год назад

    Great video Robin. very interesting and educational. Much appreciated

  • @stuartjones2242
    @stuartjones2242 Год назад

    nice job Robin , preparations the key 👍👍😃😃

  • @SJWardBuilders
    @SJWardBuilders Год назад +1

    👌Top work Robin

  • @soa324
    @soa324 Год назад

    Lovely Job that Robin

  • @caravancapers5091
    @caravancapers5091 Год назад

    Our first nu-heat was in 1997 (red twin pipe). Our second is coming in July 2023! Our only issue was the TRV and ultimately the control panel which I has to swap out for a wireless system. Not really a nu-heat problem but an issue related to a builder going through our control wiring. Our first choice was nu-heat before and again now. They have come along way in 25 years!

  • @colinturner9384
    @colinturner9384 Год назад +1

    Robin, love your channel, but all the talk of being accurate and then you go and install the pipework loops and take a different route back to the manifold different to the plans, hope you modify the plans "as installed"

  • @jongkim8386
    @jongkim8386 5 месяцев назад

    This very heating system is called "Ondol" in Korea and it started hundreds years ago.

  • @kevinmatthews2620
    @kevinmatthews2620 Год назад

    the cliptrack joints look just like scalextric track joints :) just a observation Robin :) :)

  • @ciaranclose192
    @ciaranclose192 3 месяца назад

    Did you retrofit that onto an existing floor without lowering the floor and if so how much additional height had been added to the finished floor including covering?

  • @ershadtaymourtash2529
    @ershadtaymourtash2529 8 месяцев назад

    Dear Expert,
    Thank you for the brilliant explanation. My question is whether we can install new laminate on top of old ceramics while using a wet floor heating system. Could you please guide me on whether this would prevent efficient heating conductivity, increase energy consumption, and how it might affect moisture levels? Additionally, what steps can I take to control these factors?
    Best regards,

    • @ukconstruction
      @ukconstruction  8 месяцев назад +1

      I would say that providing your system is man enough to heat the space in the first place then laying a laminate floor over the top should be ok, the following factors would need to be considered, check that the underlay and flooring is compatible with under floor heating, you may need a floor temperature sensor added to the underfloor room stat that will make sure the floor temperature will not exceed the flooring manufacturers recommendations, you may need to laytex over the tiles if the tiling is not that smooth and flat

  • @connordunne8975
    @connordunne8975 Год назад +1

    A solar pump helps will filling underfloor helps with wasted water just recirculates the same water 👍🏼

    • @paultyson777
      @paultyson777 Год назад +1

      Been doing it that way for years. Handy for adding additives to.

  • @andrewhealy7224
    @andrewhealy7224 6 месяцев назад

    What is used for hearing on the upstairs?

  • @brianfox-paterson9717
    @brianfox-paterson9717 7 месяцев назад

    Just a little confused - at 21:31gary talks about the formers keeping the pipes down as he bends them up to the manifold. It's bit difficult to see but it looks like he is on a concrete floor, certainly not a DPM over Celotex or something equally as soft. So how does he attach them.? He says you need the formers because it is a tight radius but how do they stay fixed down and in place if there is not something substantial to fix them too.

  • @robertgeiger7026
    @robertgeiger7026 Год назад +1

    So u have 2 bleed the pipes.

  • @peefor135
    @peefor135 Год назад

    Another beautifully executed job. What sort of room temperature would you expect to be able to maintain with the system shown? I would imagine that the design would have a maximum achievable.

    • @ukconstruction
      @ukconstruction  Год назад +1

      We have been running it with a super low flow temperature while we dried the screed and also from a temporary 3kw electric boiler (so half size) and we easily reached 23 degrees at the thernostat

    • @peefor135
      @peefor135 Год назад

      @@ukconstruction Thanks for the reply. I was just curious as to what temperature you were hoping to achieve in the particular rooms. Some people are happy with 19°C, whereas others are cold at 23°C.

  • @pedrostokoe1980
    @pedrostokoe1980 Год назад

    Robin where abouts are you from just wondering what areas you work in

  • @cuebj
    @cuebj Год назад +1

    RC not using a stick or two to set distances! The world is spinning off its axis!

  • @user-to8bj6iy5x
    @user-to8bj6iy5x 9 месяцев назад

    i'm afraid from any problem will be in future like shrinkage between Tile and adhesive , please any one give me feed back this procedure are safe

  • @Brown969
    @Brown969 Год назад +4

    Only UFH problem I came across was the client putting too thick of an underlay down. I think we had to find an underlay with a lower TOG which made me laugh as I thought they were confusing it with duvets😂
    I think the UFH suppliers or designers can clarify what TOG underlay to use.

  • @lukeme7702
    @lukeme7702 4 месяца назад

    What did you use for the separation layer? Cheers

    • @ukconstruction
      @ukconstruction  4 месяца назад +1

      This is a typical polythene DPM type material, it is 1000 gauge, we use this as it is readily available and very good value and cheaper than thinner gauges

    • @lukeme7702
      @lukeme7702 4 месяца назад

      @@ukconstruction thanks for the quick reply. All the best

  • @lockdownlife3.028
    @lockdownlife3.028 7 месяцев назад

    Shouldn’t the DPM been installed underneath the insulation?

    • @ukconstruction
      @ukconstruction  7 месяцев назад

      This is the separation layer not the DPM that was under the main slab

  • @davidbarnett8002
    @davidbarnett8002 3 месяца назад

    What's the expansion joint

    • @PercyJackson93
      @PercyJackson93 Месяц назад

      The strip going up the edges to stop the cement spilling out and allows expansion of the cement as well.

  • @Jonas-sg1eo
    @Jonas-sg1eo 7 месяцев назад

    membrane should be under insulation ?

    • @ukconstruction
      @ukconstruction  7 месяцев назад

      This is not the DPM this is the screed separation layer

    • @Jonas-sg1eo
      @Jonas-sg1eo 7 месяцев назад

      whats the reason for it ?
      @@ukconstruction

    • @nathanberry2744
      @nathanberry2744 7 месяцев назад

      It’s to stop any reaction between the screed and the insulation

    • @tonymott3684
      @tonymott3684 6 месяцев назад

      And to minimise the chance of the liquid screed getting under the insulation boards which would be a disaster

  • @razorlicks7929
    @razorlicks7929 Год назад

    Looks like one of the loops was mlcp and the rest were pert.

  • @deanchapple1
    @deanchapple1 Год назад

    Been a plumber for 20 years. I used to use Nu-Heat but unfortunately they are hideously over priced! Most, if not all other UFH companies are significantly cheaper and offer just as good or better service.
    Nu-Heat need to change their ways.

    • @ukconstruction
      @ukconstruction  Год назад +1

      Hi Dean, I obviously price check and I too have found cheaper systems, I am personally the kind of person that sticks with what I know and the support and technical assistance that we get from Nu Heat is second to none, we also fully trust their specifications and we have had amazing results and energy usage based on well designed systems that we have fitted over the years.

    • @deanchapple1
      @deanchapple1 Год назад

      @@ukconstruction yeah I hear what you are saying and that was exactly my attitude.
      However, I have come to discover that there’s now plenty of UFH companies offering same customer experience but at half the cost (literally).
      Unfortunately Nu-Heat are so far behind the times in regard to pricing, I can’t see how they are surviving?
      To be honest, it’s strange how expensive they are?! Given that their products are mainly generic….. I.E mainstream manufacturers just branded up as Nu-Heat.

  • @bernardgarrett3897
    @bernardgarrett3897 Год назад +1

    Too many ads.

  • @michaelplates
    @michaelplates День назад

    I hate videos where there is so much talking and very little doing - please to keep one's attention do the job and talk your viewers through it as you do it. Utter annoying when you talk and don't do.