Lockdown Learning - The recommended basic electrical safety checks you should perform

Поделиться
HTML-код
  • Опубликовано: 16 май 2024
  • Welcome to #LockdownLearning
    Here's Baxi Trainer Graham taking you through the recommended basic electrical safety checks you should perform BEFORE you work on an appliance that contains electricity.
    Note: This video is intended for Gas Safe registered engineers only.
    For more information on Baxi Training: www.baxitraining.co.uk
  • НаукаНаука

Комментарии • 45

  • @timeyre9985
    @timeyre9985 3 месяца назад

    brilliant , straight to the point, recap on essential basic appliance electrical tests.

  • @pointypipedream
    @pointypipedream 4 года назад +4

    first of all thank you not thank us backseat have really knocked it out of the park with these training videos they are complicated enough so that customers won't try things themselves but easy enough for us gas engineers to understand lol as usual Baxi make it easy

  • @steveincork3669
    @steveincork3669 3 года назад +3

    Great refresher video. Priceless information well done.

  • @sukbajwa
    @sukbajwa 4 года назад +3

    Thank you. Absolutely brilliant video.

  • @michaelcorns2936
    @michaelcorns2936 3 года назад +1

    Amazing videos keep up the good work Graham👍

  • @leonardbalint4930
    @leonardbalint4930 3 года назад +1

    clear , simple, brilliant. Thanks

  • @ersoytoprak3627
    @ersoytoprak3627 4 года назад +2

    Very good video just refreshed my mind
    Thanks 😊

  • @jamesturk3700
    @jamesturk3700 2 года назад

    Brilliant learning .. well done Baxi.

  • @raul835
    @raul835 4 года назад +9

    Another brilliant vid. No other manufacturer, as far as I know, is doing anything comparable. Appreciate the effort. Looking forward to more.

  • @adamleonard1999
    @adamleonard1999 4 года назад +4

    Graham these videos are top draw , enjoy watching them and I'm learning all the time .keep up the good work. #lockdownlearning

    • @maximoquinn7218
      @maximoquinn7218 2 года назад

      you all probably dont give a shit but does someone know of a way to get back into an instagram account..?
      I stupidly lost the login password. I appreciate any assistance you can give me

    • @sonnyronin3453
      @sonnyronin3453 2 года назад

      @Maximo Quinn Instablaster ;)

    • @maximoquinn7218
      @maximoquinn7218 2 года назад

      @Sonny Ronin I really appreciate your reply. I got to the site through google and Im waiting for the hacking stuff now.
      Looks like it's gonna take a while so I will reply here later with my results.

    • @maximoquinn7218
      @maximoquinn7218 2 года назад

      @Sonny Ronin It did the trick and I now got access to my account again. Im so happy!
      Thanks so much, you saved my account!

    • @sonnyronin3453
      @sonnyronin3453 2 года назад

      @Maximo Quinn glad I could help xD

  • @manjsingh6500
    @manjsingh6500 2 года назад

    👍😊 great video very helpful thanks

  • @monica6mikida
    @monica6mikida Год назад

    Excellent video thank you

  • @arianxhebraj6107
    @arianxhebraj6107 4 года назад +2

    great!!!!!Thank you Sir

  • @kevind7150
    @kevind7150 2 года назад

    Worcester CDi Heat only, run under reverse polarity. Discovered this recently, changing checking an external pump.

  • @sergd7885
    @sergd7885 2 года назад +1

    I have been watching your channel for a long time, I have baxi solo 2 pf the overheat lamp lights up and he does not want to turn on thanks for any help, pump ok work.

  • @paulrossiter9567
    @paulrossiter9567 3 года назад

    Brilliant 👏👏👏

  • @robbiebicker5227
    @robbiebicker5227 3 года назад

    Great video mate

  • @jamesasprey2092
    @jamesasprey2092 4 года назад

    Great video again. I have a question about the short circuit test,a reading of 20 ohms on a 240 volt appliance according to ohms law would be drawing 12 amps and would surly take the 3 or quick blow fuse out why would this be allowed to be such a low reading? Many thanks

    • @jocelynne2552
      @jocelynne2552 4 года назад +2

      Absolutely correct but boilers do not have an appliance resistance anywhere near 20 ohms if they are safe. The value of 20 ohms is a recognised figure within the industry for appliance short circuit. Some appliances e.g. electric immersions have a resistance of approximately 21 ohms and therefore draw nearly 12 Amps. Of course these types of appliances should be protected by a 13 Amp fuse.

    • @jamesasprey2092
      @jamesasprey2092 4 года назад +1

      Jocelynne on behalf of Baxi Heating trainers thank you for getting back to me and clearing that up 👍

  • @tonyyoung9838
    @tonyyoung9838 4 года назад +1

    Brilliant video thank you. My hearing is terrible can you confirm when voltage testing between neutral and earth you are saying that up to 15 volts is acceptable. Many thanks

    • @BaxiBoilersUK
      @BaxiBoilersUK  4 года назад +1

      Hi Freddy, glad to hear you're enjoying Grahams training videos. I can confirm yes 15 volts is acceptable on Neutral to Earth.

    • @davidmarsden8868
      @davidmarsden8868 3 года назад

      @@BaxiBoilersUK 0 to 15 I was always told

  • @rosstaylor4924
    @rosstaylor4924 4 года назад +4

    Well done baxi 👍

    • @suniljose22
      @suniljose22 4 года назад +1

      Great video, I am watching all of his videos from the beginning. Precise and packed with lots information. No other manufacturers help engineers like Baxi does. Thanks to all trainers at Baxi

  • @mianasifgujar
    @mianasifgujar 4 года назад +2

    Excellent

  • @abdulh63
    @abdulh63 4 года назад +2

    quick question. You said if you're doing the short circuit test, a good reading would be anything above 20 ohms and anything less would indicate a short circuit. but straight after you said a on a baxi duotec a good reading would be between 6 and 800 ohms. but 6 is 14 ohms less then 20 ohms?

    • @shaundavey1170
      @shaundavey1170 2 года назад

      I had to re wind that for the same reason. Did you ever get the answer.

  • @patrickkalisz5461
    @patrickkalisz5461 4 года назад +1

    Great videos very good learning sessions keep the good work 👍👍

  • @hosseinkarimzadeh3085
    @hosseinkarimzadeh3085 3 года назад

    Hi when end of this video during you test ac live and N and live and earth nothing is coming in your motemeter

  • @davidmarsden8868
    @davidmarsden8868 4 года назад +1

    What would you define as a “known earth source” ?
    Would my sisters false metal leg qualify. :)

  • @timeyre9985
    @timeyre9985 3 года назад +2

    god help me for the last 42 years been doing it wrong

  • @David-vw9jn
    @David-vw9jn 2 года назад

    You shouldn’t have any voltage on the the n to e test 0 not 0-15v

  • @joncoke8208
    @joncoke8208 4 года назад

    Great videos pity your technical helpline cant answer emails

  • @davidproctor6359
    @davidproctor6359 2 года назад

    books say short circuit test over 100 ohms

  • @villagelifestylehelloindia679
    @villagelifestylehelloindia679 3 года назад

    Jay shree krishna

  • @colin5064
    @colin5064 2 года назад +2

    you say short circuit with less than 20 ohms, then you contradict this with duo tech example of 6-800 ohms is good.
    Makes no sense to me !!!!!!

  • @salandjim
    @salandjim 2 года назад

    Where in TB 118 is the gas operative instructed to perform a 'safety
    touch test' or an 'earth loop impedance test' or a 'polarity test' - the
    ONLY 'procedure' derined in TB 118 is the Safe Isolation procedure !
    This video does nothing more than add to the confusion within the
    industry because TB 118 is ill-conceived, misguided, misworded,
    inaccurate and contains an unforgivably dangerous bunch of words - it
    should be no more than 2 pages long and explain what is in the title of
    the TB - a SAFE ISOLATION PROCEDURE ! The objective is simple - prove
    the test gear good, isolate the appliance, prove the appliance is dead
    and then perform a confidence test of the equipment to prove it is still
    good. Th edocument has opened the flood gates for test gear
    manufacturers to sell kit for checks that are NOT required to keep the
    gas operative safe ....