this is nonsense explanation. the differential is how far the pressure should be down to get the motor "on" again which should be Range-differential value. in this case the pump will get on (Range is set 2 bar - Diffe 1.5 = 0.5 bar) so the motor will get "on" below 0.5 bar and once the pressure reached 2 bar, the motor will get "off". another example is if we keep the range at 7 bar and differential at 1 bar, the motor will get off when the pressure in above 7 bar and get on when the pressure goes below 6 bar (which is 7-1=6 bar)
😂pehle khud seekh lo fir logo ko sikhao Itna bada bada likha huabhai Cut in/out is range minus differential Jo aap bol rahe ho ki kuch log rang ko kam kar dete hain wohi tumne kiya hai
Good 👍
Nice explain 🎉
Sir. 2500 lpd tank may kitna satting rakhna cheya ?
Buhat tight❤😊
Good and simple explanation. Dhanyawad Ji.
Thanks sir
this is nonsense explanation. the differential is how far the pressure should be down to get the motor "on" again which should be Range-differential value. in this case the pump will get on (Range is set 2 bar - Diffe 1.5 = 0.5 bar) so the motor will get "on" below 0.5 bar and once the pressure reached 2 bar, the motor will get "off". another example is if we keep the range at 7 bar and differential at 1 bar, the motor will get off when the pressure in above 7 bar and get on when the pressure goes below 6 bar (which is 7-1=6 bar)
Hello
Ha boliye
Boss 0.37kw pump ke liye kitna setting rehna chahiye.....?
Sir iski control wiring ka connection ke sath practical karke bataiye
Ok bhai ji
Clamp meter se kaise pata karenge ki common, NC and NO kon hai
continuity check kr ke
mera pressure pump bhoot jldi on off hota hai , water flow bhi fluctuate hori hai ! kya solution hai iska ?
leakage check kr lo,Differential pressure ko increase kr do
ok i will try ! thank u !
He😢
Kya hua
Video me meter nhi dikha . 😊
Help me
Ok sir boliye
Range aur difference hota kya hai basic toh bataya hi nahi.
P. Swich kam nhi kar rha h kia tank ka parasar bhi chack karna h
Pressure switch kaha pr lgaya h
@@Stationofeducation 1hp parasr pamp
Swich bhi naya h
@@Stationofeducation watar tank ke pass booster pamp new swich lagane par bhi kam nhi kar rha h
Bypass karke check kar lo
Don't give wrong information regarding difference and range
Beech beech ma motor chalta hai kya wajah haii magar bib cock off hooka bhi 2 sec chalta haii khuch information dooga sir
Normal kitna रखना चाहिए
Low pressure dekharahe kiya karna he
Sir apka no. Bhejiye mujhe bat karni switch ke bare main
Pls sir jara jaldi bhejiye no.
Kbhi bhi galt information nhi deni chahiye
Pressure switch ki jo bhi video chahiye aap mere channel pr dekh lo mil jayegi ok
लगातार चल रहा है
Isme nipple size kaun sa lagega
Galat bataya h 2-1.5 = 0.5 pr start hoga
ruclips.net/video/aVrdLhwbs5A/видео.html&feature=share9
Prectical video h dekh lo
दबा के बकवास, बीच में ही exit marna para
Kyu
@@Stationofeducation bhai setting aise nahin hoti h jase aapane kari hai..
Yeh galat bataya… motor 1.5 pe start nahee hoggi.. 2 (-) 1.5 = .5 pe chaloo hoggee… vdo banane se pehle thoda padh liya karo
Ideal kya hona chahiye for 3story building...bar and differential?
😂pehle khud seekh lo fir logo ko sikhao
Itna bada bada likha huabhai
Cut in/out is range minus differential
Jo aap bol rahe ho ki kuch log rang ko kam kar dete hain wohi tumne kiya hai
ruclips.net/video/aVrdLhwbs5A/видео.html&feature=share9
It's ok
Wrong information 😢
ruclips.net/video/ElFGsyLaE6w/видео.html
pressure switch connection
Kya bekar video hai yar. Sab galat information hai.
Abe dhakkan logon ko galat information kyon de raha hai jab nahin pata to...
Tamij se baat kar
Mujhe ye bta kya glt h