السلام علیکم ورحمۃ اللہ وبرکاتہ میں خود ایک واٹر پلانٹ میں کوالٹی انچارج ہوں مائیکروبائلوجسٹ اینڈ کیمسٹ بہت اچھا لگتا ہے کہ اپ سمجھ کی باتیں بتاتے ہو ایسے ہی اپ لوگوں کے ساتھ اپنی سمجھ ساجھا کرتے رہو 😊😊شکریہ
Antiscalent high pH ka ya low pH , konsa use karna chahiye, Membrane konsi use karni chahiye kya ye feed TDS ke calculation pe depend karta he,..please solve it.
Sir how much will we dosing required ppm because in this video LSI range -0.3 to +0.3 but your another video LSI range and dosing ppm is different please consider at once time.
Bro I am from Bangladesh. I want to know if total feed flow in antiscalant calculation is only RO product. Or product and rejection are calculated together. Please bro reply❤
Assalam oalakum Bhai mian aik water filteration plants manufactured compony mian as service technician Kam kerta hon. ham na aik UF lagi ha Kisi company mian ab chock ho gi ha ham na HCL aur h2so4 high pH chemical say cip ki ha lakin us ka matloba flow nhai a rha bhai Koi aisa chemical btain jis say us ka flow normal ho ja
Sir, Water chemistry check kar k pher koi action lia jaata h, Agar CIP kar li h,tu may be us water main bacterial growth bohat ho membranes k andar bio fouling ho skti h apko alkaline ky sath sath hypo bhi dose karna chaheay and hypo ki circulation bhi karwaeyn
Why cant you dose antiscalant concentrate without calculations? I mean, I am tired of preparing these dosing solutions. I want it to prepare automatically. So here is what I will do. 1. Small tank, not more than 5 liters. 2. Install a small float valve. Hook it to tap water. Fill the tank. 3. Install a pH probe on the tank. Settup up the monitor to required antiscallants pH enough to descale. 4. Install a doser to this monitor and probe. Let it maintain the pH. 5. Install another doser to take the fluid and dose it to the RO. Why shouldn't this work?
No sir, Antiscalant ka koi name nahi hota na formula hota hy Ye blend hota h different chemicals ka is leay isy jusy anti scalant kaha jata h mean scale ko khatak karny wali cheez
السلام علیکم ورحمۃ اللہ وبرکاتہ میں خود ایک واٹر پلانٹ میں کوالٹی انچارج ہوں مائیکروبائلوجسٹ اینڈ کیمسٹ بہت اچھا لگتا ہے کہ اپ سمجھ کی باتیں بتاتے ہو ایسے ہی اپ لوگوں کے ساتھ اپنی سمجھ ساجھا کرتے رہو
😊😊شکریہ
Thank you sir
Sir LSI FORMULA is very good thank you sir 😊❤
Nice information
Thank you
Thank you thank you thank you so much Bhaijan 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
Welcome brother
Nice
Excellent sir ji 👍👍
Thanks 👍👍
very help full sir
Thank you 💞
Love you hogya bhai❤❤
Thank you
Super 👍🏻
Thank you
Thanks Brother ❤❤❤
Very very nice ❤❤❤
Thank you
Antiscalent high pH ka ya low pH , konsa use karna chahiye,
Membrane konsi use karni chahiye kya ye feed TDS ke calculation pe depend karta he,..please solve it.
Thnx sir ❤
More antiscalant using high ppm any changes water test sir
sir RO plant kese work karta hai or iski fitting waghera kese hoti hai iski infaormation pr 01 vdidio bana dejiye sir🙂
assalamu alaikum bhai saudi me Afras company kaisi hai please rely me
Purified water ham 24 Hur kyu circulation karva te he agar ham circulation nohi karega to kya haga
Sir my company ro running hrs 16
24m³/h he to kitna dosing krna chahie dosing tank he 100liter ki hr
Sir how much will we dosing required ppm because in this video LSI range -0.3 to +0.3 but your another video LSI range and dosing ppm is different please consider at once time.
Bro I am from Bangladesh. I want to know if total feed flow in antiscalant calculation is only RO product. Or product and rejection are calculated together. Please bro reply❤
Brother
Total feed flow mean ....
Total water that goes to membranes...
Why after RO water is bitter sir
Sir alknity kya hota h
sir where is the LSI formula link
Sir hum logo ka water quality 550 tds hai ak normal Bol dijia kitna ppm dosing karna hai plz bata dena
5 ppm enough
Where are you working in current days please reply me।
Hlo sir my new plant of ro project capacity is 110m³ what will be the dosing rate
How many hours plant running per day?
Give the correct dosing ppm according to LSI range please sir
Thanks sir ji
Welcome
Me aap se class lena chahata ho its possible
RO uf or etp ka experience he but theory nai he
Assalam oalakum Bhai mian aik water filteration plants manufactured compony mian as service technician Kam kerta hon. ham na aik UF lagi ha Kisi company mian ab chock ho gi ha ham na HCL aur h2so4 high pH chemical say cip ki ha lakin us ka matloba flow nhai a rha bhai Koi aisa chemical btain jis say us ka flow normal ho ja
Sir,
Water chemistry check kar k pher koi action lia jaata h,
Agar CIP kar li h,tu may be us water main bacterial growth bohat ho membranes k andar bio fouling ho skti h apko alkaline ky sath sath hypo bhi dose karna chaheay and hypo ki circulation bhi karwaeyn
@@abrazzaqinfo thanks Bhai
Why cant you dose antiscalant concentrate without calculations?
I mean, I am tired of preparing these dosing solutions. I want it to prepare automatically. So here is what I will do.
1. Small tank, not more than 5 liters.
2. Install a small float valve. Hook it to tap water. Fill the tank.
3. Install a pH probe on the tank. Settup up the monitor to required antiscallants pH enough to descale.
4. Install a doser to this monitor and probe. Let it maintain the pH.
5. Install another doser to take the fluid and dose it to the RO.
Why shouldn't this work?
Anti scalent Ka koi formula hota hy?
No sir,
Antiscalant ka koi name nahi hota na formula hota hy
Ye blend hota h different chemicals ka is leay isy jusy anti scalant kaha jata h mean scale ko khatak karny wali cheez
Ap SRACO ki kis side per duty kr rahy hn men bi SRACO men job kr raha hn men Dammam men hn ap kis jagha hn?
Men ny ek Pakistani chemical dealer sy pocha tha to us ny btaya k ye bhr sy Powder form men ata hy pher is men pani add kr k agy sale krty hn
Btother is ka name our ye kis kis chemical se banta hy is pay complete vedio banai hoi mainy aap daikh lejeay ga
@@abrazzaqinfo okay men Dekho ga
10 meter cube ro plant will have feed flow of 30 meter cube. feed flow is not permeate flow
Thanks sir
Welcome