  • @danielbersalis5224
    @danielbersalis5224 7 месяцев назад

    very good talk , great resume , love it

  • @rashwan2527
    @rashwan2527 6 месяцев назад

    Hi ! Thanks for the informative video. 16:38 what might be the reason for the difference in the pattern of relative amplitude of harmonic family of inner race and outer race?

    • @Stubbornnut
      @Stubbornnut  6 месяцев назад

      outer race fault: energy dissipates through the bearing housing leading to attenuation at higher frequencies
      inner race fault: energy is more efficiently transmitted and potentially amplified through the rotating components leading to increase harmonic amplitudes at higher frequencies.

    • @rashwan2527
      @rashwan2527 6 месяцев назад

      Thanks a lot for clearing the concept :)

  • @alloveryetstill
    @alloveryetstill Год назад +1

    Thanks for gold bliar

  • @jamintoday5137
    @jamintoday5137 5 месяцев назад

    Do you have slow info on bearing under 300rpm. I get rpm and number of balls. But i cant pass Charlottes test for cat2

    • @Stubbornnut
      @Stubbornnut  5 месяцев назад

      Under 600rpm use displacement.