Same PCB.. PFC complete ckt blown up, including IGBTs, PNP, NPN transistors and connected resistors. I do not have the component details.. is it possible for you to provide it or make a video on PFC ckt for this PCB with details of the all PFC components. Thanks in advance. U seems to me proper engr. Keep it up. Cheers
Hi,thanks for the video again.It's great as usual.However,my humble request is to include english translation in your videos,please.This way you will have more views i think.I did ask you in the past in one of your videos and you've said ''Ok"'.Please,include english subtitles in the videos,sir.Thanks.
Nice information, sir ji Daikin ke isse board me IGBT RJQ per on board lage Reactor se aane wali supply per 7D0 Resistance or V6 Diode lage hai, wo IGBT ke saat kharab ho jate hai unki value kya hoti hai.. please help me Thank you
The Best ING i have seen. Thanks for sharing your knowlege, next video in English, at least, because i speak spanish thank You anyway, saludos desde Tepic Nayarit México. I do understand English.
Really good information sir ji and once again thanku sir aap ka student bhi hu aap hamesha tumara support humko dete reheto ho sir really kitni bijy me bhi aap ne video karte there ho thanku for information sir
Sar ji namaskar Ahmedabad BM Service Center se bol rahe ho Sar ji aapka koi PCB Hamen aapko Daikin Ki Koi Bhi bhejni Ho To Ham bhej sakte hain to Aapka adress bhejiye
Bhai aapki video bahut acchi lagti hai bahut acche se aap samjhate hain aap 2 ghante 4 ghante ka video banaen Fir Bhi Ham pura dekhne ke liye taiyar rahte hain
I've this EXACT same PCB in my Daikin Inverter 5 Star AC, 1.5 Ton. The error showing is F3. The AC is out of service since 28th Apr 2022 & Auth Service Technician is not able to find the exact fault. AC is only 4.5 years old. The compressor starts & runs at full load for 5-8 mins. Pulling ~10 Amps. Unit is rated at 5.9 Amps only. It gets extremely hot & trips after 5-8 mins. The ODU fan runs for another 1-2 mins & stops as well... After some time the compressor again runs for another 5-8 mins & trips again. This cycle repeats again & again & then F3 error shows on indoor display. There is not much cooling coming form the indoor unit. F3 denotes Outdoor unit discharge temperature is too high caused by 1) Low refrigerant (R32 was recharged twice) 2) Faulty Sensor (New sensor installed) 3) Blocked Pipe (ODU is only 18 ft away & not very old with only 3x 90 degree bends) 4) Faulty PCB Daikin Auth Tech replaced PCB & the problem remained so he told me the new PCB is also faulty & he will get another one. He is adamant that the PCB is at fault & there is nothing wrong anywhere else. Changing PCB is very expensive. Is the PCB really at fault & could be repaired if so ????
sir sensor pr 4 volt ban raha hai phit bhi p4 erroraa raha hai kya karun sir aur pfc ka relay on nahi ho raha hai
Same PCB.. PFC complete ckt blown up, including IGBTs, PNP, NPN transistors and connected resistors. I do not have the component details.. is it possible for you to provide it or make a video on PFC ckt for this PCB with details of the all PFC components. Thanks in advance. U seems to me proper engr. Keep it up. Cheers
Hi,thanks for the video again.It's great as usual.However,my humble request is to include english translation in your videos,please.This way you will have more views i think.I did ask you in the past in one of your videos and you've said ''Ok"'.Please,include english subtitles in the videos,sir.Thanks.
Yes in English please. Saludos desde Tepic Nayarit México
Sir best explain. Sir from where you get schematic. Pl guide thanks alot
Sir, Aap konsa SMD gun use korte hain?
Sir, aap ne jawab nahi Diya
Nice information, sir ji Daikin ke isse board me IGBT RJQ per on board lage Reactor se aane wali supply per 7D0 Resistance or V6 Diode lage hai, wo IGBT ke saat kharab ho jate hai unki value kya hoti hai.. please help me Thank you
Sir micro prosesor change nhi huta kia
Excellent explaination with proper tools and modern equipment Sir Ji. Keep going I am egarly waiting for your next extraordinary tutorial.
Error code list please send me
👌👌👌👍
Sir ek request he. Plz aap isi video me Jo PCB dekha rahe he iska diagram de sakte he. Plzz plzz plzz 🙏🙏🙏
Join Qphix membership frist
What if h5 shows how to fix those
Thanks sir
SIR DAIKIN INVERTER AC OUTDOOR PCB me fan motor not working plz tell me what is the exact fault
Sar h6 ka video
Bom dia valeu
Good 👍
Plz make one video on compressor on and off on same pcb
Ok sir
Sar Esme kampresar nhi chal rha hai
me aapke sare videos dekhta hu sir best hai ek daikin e8 error par bhi bna dijiye video full details me
Bilkul banaynge sir
The Best ING i have seen. Thanks for sharing your knowlege, next video in English, at least, because i speak spanish thank You anyway, saludos desde Tepic Nayarit México. I do understand English.
Really good information sir ji and once again thanku sir aap ka student bhi hu aap hamesha tumara support humko dete reheto ho sir really kitni bijy me bhi aap ne video karte there ho thanku for information sir
holle sir if resistor burn number how to know value?
Yahi video valid pcb me 7d0 rjistar ud jata hy. Compressor 4 amp par panache te hi band ho jata hay
Sar ji namaskar Ahmedabad BM Service Center se bol rahe ho Sar ji aapka koi PCB Hamen aapko Daikin Ki Koi Bhi bhejni Ho To Ham bhej sakte hain to Aapka adress bhejiye
Msg on whatsapp 7297939704
Me encantaría poder ver subtítulos en español
Bhai aapki video bahut acchi lagti hai bahut acche se aap samjhate hain aap 2 ghante 4 ghante ka video banaen Fir Bhi Ham pura dekhne ke liye taiyar rahte hain
Please have an English channel even though with robotic sound
sir ye bord ka H0 video bnado aek jo bar bar igbt shot hoti hai very naice werk
Ok
Very usefull video for me,,,thank u so much..plz keep making this kind of detail video.👏
I've this EXACT same PCB in my Daikin Inverter 5 Star AC, 1.5 Ton. The error showing is F3. The AC is out of service since 28th Apr 2022 & Auth Service Technician is not able to find the exact fault. AC is only 4.5 years old. The compressor starts & runs at full load for 5-8 mins. Pulling ~10 Amps. Unit is rated at 5.9 Amps only. It gets extremely hot & trips after 5-8 mins. The ODU fan runs for another 1-2 mins & stops as well... After some time the compressor again runs for another 5-8 mins & trips again. This cycle repeats again & again & then F3 error shows on indoor display. There is not much cooling coming form the indoor unit.
F3 denotes Outdoor unit discharge temperature is too high caused by
1) Low refrigerant (R32 was recharged twice)
2) Faulty Sensor (New sensor installed)
3) Blocked Pipe (ODU is only 18 ft away & not very old with only 3x 90 degree bends)
4) Faulty PCB
Daikin Auth Tech replaced PCB & the problem remained so he told me the new PCB is also faulty & he will get another one. He is adamant that the PCB is at fault & there is nothing wrong anywhere else. Changing PCB is very expensive.
Is the PCB really at fault & could be repaired if so ????
!! Msg on whatsapp plz.
@@qphixappliancerepair5888 Done... Please check WhatsApp
Thank you sir first time daikin bord riparing video. 👌
Sir kisi bi circuit ka diagram ke se dawonlod kare
Inke diagram nhi milte sir ji
Sir agr thermistor kharab ho uski value agr maloom na ho wo k say pta lgayengai k ktna thermistor lgega.
Very very nice video and good explanation sir. Thanks for sharing
Reetika Electronics,Rohtak
Sar bahot hi achhi lagi yeh video thank you so much sar
Sir apka contact no milenga
7297939704
Super.. I want this training. Sir
Whatsapp for training related details 7297939704
Thank you sir
Mza aagya sir ji... Ek ap or ek apka smjane ka tarika fantastic h
sir mujhe daikin ki pcb bhejni hai aapko repair ke liye kaise bheju
SAMSUNG INVERTER AC ERROR - PC 04 KYA PROBLEM HAI SIR
Thank you sir
Thank you so much bro for this great knowledge.
Daikin "H6" error show please this topic apload video. thinking you please please please 🥺🥺
Ok sir
Apki her video m kuch jyda hi sikhne ko milta h
Very professional work sir 👌
Sir aap ka adress kya hai traing ke leye
Jaipur Rajasthan online offline classes available h
Thank you bhaiya to make this video 🙏🙏🙏🙏🙏🙏🙏
स्मार्ट इन्वर्टर एसी बनाने के पीछे का ऐसा क्या कारण है ?
Electricity losses ko km Krna
@@qphixappliancerepair5888 ऐसे एसी error ज्यादा दे रहे है !
Sir data sheet erore code ka kaise milega plz reply
Sir apka service center ka address kaha per hay?
Please reply sir
Jaipur Rajasthan
Sir PCB repair Charge kitna he aapke service centre me
Excellent and deep information sir. Thanx
❤
Sir same pcb compressor 4 minit bad off ho jata hai
Ye PCB repair karbane hai sir aapka office kaha par hai
Nice video
Very nice explain sir thank you
How you make diagram please tell me
Nice explaination
Tools are great, very nice sober person hai sir ji
Wow super sir
Chandigarh
H0 error code par video banaye kis bajah se aata hai
Great explanation sir, wonderful work and knowledge.
Agar iska pfc blast. To iska koi solution h
Very good explanation 5 star
Nice work keep it up and good info for technician
Great work great job nice person
Sir ji h 6 kiya arrcod h
Good bro
Veri nice 👍
Very very informative video. Thank you.
❤️❤️❤️❤️❤️
Ram Ram ji ❤
Correct & perfect explanation
Very informative video 💖💯🔥
Great explanation
Realy a good service
Sir ji very very Thanks
Ustad ji very good ❤❤❤
Sir kitna kharcha hoja
Msg on whatsapp for all details
@@qphixappliancerepair5888 WhatsApp number please
Superrrrrr
Jordar Video 👌🔥🔥
Need ur videos regularly
Thanks 👍
Nice sir ji
Sir muje pcb repair sikhne ke liye ana hey charge kaya hey apka content no bhejna
7297939704
nice
Sir muje inveter ac ki pch repair ke leye bhejna apka content no bhejna
7297939704
Jai hind
Good explained 👌🙏
Good job 👍 sir
Sir please explain us about h6 error in daikin inverter ac
Ok
Hmm sir
Too good sir
Bhai ji bahut ache se batye ho app pcb repair khikha sakta ho mughey pls
Call for training details 7297939704
Sir hame ye cors karana hai please aap aapna adrass
Msg on WhatsApp 7297939704
Sir mujhe ye resistance ke book chaiye the
Call 7297939704
Sir godrej inverter ac main P0 E9 ka error ahraha he kyu?
Sir pls whatsapp pr msg kre thanks
WhatsApp number?
Sir is board me 00 ka error ata hai kis Karan se ataa hai use par bhi ek video banao please
00 ka matalab h sb normal hai
@@qphixappliancerepair5888 sir fir bhi system on nahi hota hai
Last tk dekhe bahut achhe se bataye apne
U r a good teacher
Very good Sir
Thanks sir
Sir iske ipm me bhi thermistor laga hota jiski output processor ko nahi jati hai isme self ot protection hota hai
Is ipm m tharmister nhi h sir
Sir check this ipm datasheet
This ipm 17 number thermistor pin
PSS15S92E6-AG