daikin ac outdoor wiring | split ac outdoor wiring | Gayatri airzone

Поделиться
HTML-код
  • Опубликовано: 27 ноя 2024

Комментарии • 44

  • @muthu6418
    @muthu6418 3 месяца назад +1

    Very Nice. I have changed capacitor myself by seeing this video. Great Work!

  • @souravrajput3839
    @souravrajput3839 6 месяцев назад +2

    TQ Bhai ji apke ye video best hai

  • @rakeshsuthar7441
    @rakeshsuthar7441 2 года назад +2

    Bhai Daikin me old model me Jo contor atahe us ki jagah par reguler contracter kese lagye us par vidieo banavo

  • @ajmeransari8142
    @ajmeransari8142 Год назад +1

    Good practical

  • @1stchannal964
    @1stchannal964 2 года назад +1

    Thrnk you sar

  • @Gulammustafa-official095
    @Gulammustafa-official095 2 года назад

    Nice video

  • @officialhonorupdates
    @officialhonorupdates 2 года назад +1

    I have 4 wires comming out of my indoor to outdoor one is live second is netural and third is ground so for what purpose fourth wire is and my outdoor has only 3 connector

    • @GayatriAirZone
      @GayatriAirZone  2 года назад

      The first one is phase and second is neutral and third one for communication wire. And you told that you have only 3 slots. Then earth connect with outdoor body.

    • @officialhonorupdates
      @officialhonorupdates 2 года назад +1

      @@GayatriAirZone i have seen on my outdoor 3 pins one is mentioned live second is netural and third is ground were should I connect communication wire?

  • @lakshkumar1362
    @lakshkumar1362 7 месяцев назад

    भाई आउटडोर के लिए सप्लाई कहा से देना है मेन मीटर से देना या नॉर्मल बोर्ड से

    • @GayatriAirZone
      @GayatriAirZone  7 месяцев назад

      Supply power plug se bhi de sakte ho bas wire 2.5mm se upar ka hona chahiye

  • @truefact2.015
    @truefact2.015 Год назад +1

    Same sound Ata Hai sir it's normal na

  • @sameerhafiz6479
    @sameerhafiz6479 2 года назад

    Sir g ap iski pcb ki wiring ki bhi video bana dijiye please sir g

  • @RahulKumar-gl5uo
    @RahulKumar-gl5uo 4 месяца назад

    Agar contactor hata de to koi problem hogi indoor pcb me..?

  • @mdasrar489
    @mdasrar489 2 года назад

    Bhai running wire starting wire ko acche se batao is ka kya kaal h

  • @chaitanyasharma1215
    @chaitanyasharma1215 Год назад

    Mere daikin ko sadhe 6 saal h split ac usme kl us bnde ne capacitor lga dia epcos ka.... Muje kuchh ni pta ta ab lgra gdbd h pls btao

    • @GayatriAirZone
      @GayatriAirZone  Год назад

      Problem kya Hai ac me

    • @chaitanyasharma1215
      @chaitanyasharma1215 Год назад

      @@GayatriAirZone hwa Kum t aur cooling bhi Kum thi aur jlne ki hlki smell t aur hlki awaz b pr 2016 m lia hai

    • @GayatriAirZone
      @GayatriAirZone  Год назад

      Service krwao ac ki or wiring or motor check karwao

  • @truefact2.015
    @truefact2.015 Год назад

    Outdoor to much noisy purchase last day but sound like drill machine or replacement Kiya Outdoor same problem kya reasons hoga sir

    • @GayatriAirZone
      @GayatriAirZone  Год назад

      Ya to fan ki wajah se noise aa rha h body se sahi connect nhi h ya fir compressor noise kr rha Hai
      Ya fir jis surface par rakha h waha balance sahi nahi Hai

    • @truefact2.015
      @truefact2.015 Год назад

      Visit technicians pipe touch and both unit sound same noise

    • @GayatriAirZone
      @GayatriAirZone  Год назад

      WHT did he said ?

  • @ahtishammalik9112
    @ahtishammalik9112 2 года назад

    Thanks bro

  • @mdikrar1290
    @mdikrar1290 9 месяцев назад

    Aapne red wala compresar me starting lagaya hai our bhai fir aapne usko ranning bana diyq

  • @nadimbgn6513
    @nadimbgn6513 Год назад

    Samjh me nhi aaya Bhai running stating sahi se batao

  • @mdshamshad848
    @mdshamshad848 2 года назад

    Daikin split inverter AC hai non inverter banana hai indoor ka pcb chenge karna padta hai kiye

    • @GayatriAirZone
      @GayatriAirZone  2 года назад

      Nhi bas compressor change krna padega or outdoor ki pcb hata k contractor laga dena

    • @mdshamshad848
      @mdshamshad848 2 года назад

      @@GayatriAirZone contractor jaroori hai indoor se to cp comnition to aayega na to contactor q

    • @GayatriAirZone
      @GayatriAirZone  2 года назад

      Safety for compressor

  • @sahudrocksahudrock7184
    @sahudrocksahudrock7184 Год назад

    Bulu wair kaha laga huwa hranig se

  • @V98000
    @V98000 2 года назад

    सर, मेरे यहाँ जो अंडरग्राउंड पाइपिंग हुई है उसका साइज 12mm और 6mm है जो कि 1.5 टन की मशीन के लिए सूटेबल होती है।
    मेरे को 2.2 टन का AC लगाना है, जिसके लिए कम्पनी कहती है कि 15mm और 6mm की पाइपिंग होनी चाहिए।
    क्या 12mm वाली पाइपिंग से ही कनेक्शन करने पर पूरी कूलिंग नहीं मिल पाएगी?

    • @GayatriAirZone
      @GayatriAirZone  2 года назад

      Ho jayega usi me

    • @V98000
      @V98000 2 года назад

      @@GayatriAirZone ok
      210sqft के ड्राइंग रूम एरिया के डाइकिन 1.8 टन (6400वाट) नॉन-इन्वर्टर सही रहेगा या फिर कोई और नॉन-इन्वर्टर?

    • @GayatriAirZone
      @GayatriAirZone  2 года назад

      @@V98000 direct sunlight ho room par to non inverter warna inverter le lo

  • @mdtecnicalmoin9852
    @mdtecnicalmoin9852 10 месяцев назад

    Bhai cp ka wire hai wo samaj me nahi aaya hai

    • @GayatriAirZone
      @GayatriAirZone  10 месяцев назад

      Line natural or cp se bas Jo kaam aayega wo cp or natural hoga line wire ko kisi me connect nhi karna

  • @mdtecnicalmoin9852
    @mdtecnicalmoin9852 10 месяцев назад

    Isme contactor nahi hai bhai

    • @GayatriAirZone
      @GayatriAirZone  10 месяцев назад

      Yes contractor wali alag se bnai Hui h video

  • @ssajid2845
    @ssajid2845 9 месяцев назад

    Thanks bhai