What Can It ACTUALLY Handle? - EcoFlow Delta Pro Ultra Testing

Поделиться
HTML-код
  • Опубликовано: 26 сен 2024

Комментарии • 88

  • @TheSolarLab
    @TheSolarLab  3 месяца назад

    🛒 EcoFlow Delta Pro Ultra:
    • Shop Solar: shopsolarkits.com/collections/ecoflow-delta-pro-ultra/products/ecoflow-delta-pro-ultra?ref=TheSolarLab
    • Use Code: DPU505 for $505 Off a Delta Pro Ultra Kits & Get Free Shipping
    • EcoFlow: shrsl.com/4el4o
    🛒 Anker F3800:
    • Shop Solar: shopsolarkits.com/collections/anker-f3800-kits/products/anker-f3800?ref=TheSolarLab
    • Use Code: THESOLARLAB101 for $101 Off Your Order
    ☀ Calculate Solar Panel Cost for your House: www.solar-estimate.org/solar-calculator?aff=207512&cam=750
    🔔 Subscribe to our RUclips Channel: @TheSolarLab
    0:00 - Intro
    0:40 - Baseline Tests (Efficiency, Charge Speed, etc...)
    5:45 - Practical Testing (Kitchen Loads, etc...)
    8:26 - Heavy Duty Testing (Shop Loads, Car Lift, Compressor, etc...)
    13:45 - Conclusion
    The EcoFlow Delta Pro Ultra is one of our favourite new units! But what can it power? Today, we are finding out! It let us down in a few areas that we didn't think it would.. but all in all, it performed pretty well & we would always recommend this until! All power stations have their own issues, nothing is perfect. But the Delta Pro Ultra comes pretty damn close!
    ⚡ FOLLOW US:
    instagram.com/thesolarlab/
    www.tiktok.com/@thesolarlab
    👨🏼‍💻 The Solar Lab:
    www.thesolarlab.com
    We maintain an affiliate relationship with some of the products reviewed, which means we get a small percentage of a sale if you click our links, at no cost to our viewers.

  • @chiron03
    @chiron03 3 месяца назад +10

    I would verify that X-Boost was NOT enabled. X-Boost allows increased wattage by lowering the voltage. Which could explain the weird issues with things not working well. Which things that are voltage sensitive, i.e., the compressor/car lift would struggle if their electric motors aren't getting the correct voltage. According to Ecoflow, X-Boost is enabled by default in their products. Which would also explain why it was running the like 8400w load for as long as it did before you added another like 800w, and then it shut off.

  • @LordHillAquarium
    @LordHillAquarium 3 месяца назад +13

    Costco has deals on this including one with 3 batteries and the panel for $10k

  • @heart4Pahoa
    @heart4Pahoa 3 месяца назад +14

    It might be worth contacting EcoFlow to see about getting another unit in case there is something wrong with your unit. EcoFlow: We are awaiting your response.

    • @petergrinsell86
      @petergrinsell86 3 месяца назад +1

      As the amperage or voltage increases the other would drop, I wonder if it can run portable MRIs for First Responders.

    • @JDCheng
      @JDCheng 2 месяца назад

      @@petergrinsell86 Never heard of a portable MRI.

  • @dennischristians
    @dennischristians 3 месяца назад +5

    Very much appreciate your ongoing review of this system. I purchased a unit with two batteries and have been running tests to charge our EV using the pass thru (w/solar). Generated 24kWh yesterday for a 30% charge to the car using the 30a outlet. Didn’t realize I couldn’t use that outlet with the other charging options. Also ran into an error when using the high PV input giving me a 479 error code. Seemed to be related to a quick drop in light intensity. I could turn off the solar inputs and restart to restart charging, but obviously not ideal. Reached out to EF and they told me to send the unit back. Reached out to the vendor where I purchased and they found info that the issue was resolved with a firmware update. I had to wait a few days (unsure why) for the firmware update to appear in my app, but so far that has resolved the error code. Seems like there are still bugs to be sorted out, but overall happy with the setup and flexibility.

    • @HieuHoang-py8oe
      @HieuHoang-py8oe 28 дней назад

      What cable did you use to charge the EV with the DPU?

  • @ronbridegroom8428
    @ronbridegroom8428 3 месяца назад +7

    Ask EcoFlow for their comments. It is supposed to handle up to 120 LRA

  • @NorthernMTB
    @NorthernMTB 22 дня назад

    @TheSolarLab, no sure if the unit you have tested had some hw or firmware issues, but my DPU is actually able to pass power to the 240v L14-30 Generator plug AND charge the DPU while charging via the side Power Input/Output (which seems to be what you are doing). I have tested this a few time already with my WGEN9500. Because of your video I contacted Ecoflow, which confirm that this setup is actually supported. What is not supported however is using the regular AC Input port in the front with high-voltage charging at 240v/15a and use the AC Output.
    Would love to see you test this again!

  • @gelu88
    @gelu88 3 месяца назад +2

    The test i'd love is see which units support AC charging with solar bypass. Because I'd like to have a battery permanently plugged through a transfer switch to a couple of Ciscuit at my house and take advantage of solar.
    This way would be plug and play vs a traditional full solar system.
    The eg4 3000 (and most hybrid inverters) supports this, but none of the portable ones do.

  • @NextProjectawesome
    @NextProjectawesome 3 месяца назад +4

    Oooh nice would loved to have seen airconditioner

    • @criticalhadlock886
      @criticalhadlock886 3 месяца назад +2

      EcoFlow claims it will start and run a 3.5 ton AC. But I believe that is only if you have a soft start installed on it.

    • @NextProjectawesome
      @NextProjectawesome 3 месяца назад +1

      @@criticalhadlock886 at least in my part of canada, softstarts aren’t a thing. Talked to several electricians and air conditioning companies and no one would touch it :(

    • @NextProjectawesome
      @NextProjectawesome 3 месяца назад +1

      Even offered to buy it ahead of time

    • @terrya6486
      @terrya6486 3 месяца назад

      I installed a soft starter 25 years ago on my A.C unit He dropped its startup search by about fifty percent. Now I live off the grid With a twelve k transformer style inverter.​@user-ke4ev5pb6p

  • @evahsia
    @evahsia 3 месяца назад +3

    The specified capacity of the battery is 6144Wh. This would change your calculations slightly.

  • @Shorby99EK
    @Shorby99EK Месяц назад +2

    I don’t understand I’ve seen other people AC charge it and pass through 240 volts

  • @fastamx069box8
    @fastamx069box8 3 месяца назад +3

    Try 2 units with the 50 Amp output. It will run everything 👍
    Excellent presentation and review...

    • @bobafet5363
      @bobafet5363 3 месяца назад

      That what I was thinking!!!

    • @FatMat916
      @FatMat916 2 месяца назад

      2 inverters?

  • @thom1218
    @thom1218 3 месяца назад +4

    To run inductive loads like table saws, pumps (esp. well pumps) and your car lift, the inverter generally needs to be an LF inverter (low frequency) - they use heavy iron-core transformers to absorb surge. Most of these "power station" units use HF or high frequency inverters which are very sensitive to inductive loads and surges they produce, but they're cheap to make and they're very efficient. LF inverters are heavy and not very efficient... but they can handle inductive loads very well. What's probably going on here is that ecoflow is putting a little toroidal transformer in the inverter circuit and over selling its inductive load surge capacity - or your car lift surges (even just for the briefest micro second) passed the surge advertised capacity.

    • @beckerwholesale2913
      @beckerwholesale2913 2 месяца назад

      So is the delta pro ultra the better one to use for a water well pump?
      would it do better if you added another battery?
      or two?

    • @thom1218
      @thom1218 2 месяца назад

      @@beckerwholesale2913 Adding batteries wouldn't help as since the components used in the inverter circuit are the limiting factor. I'd use the Anker SOLIX F3800 because I know for a fact that one uses an LF inverter, though its efficiency tops out at 88 percent. I'm not sure what type of inverter the delta pro ultra uses....

    • @melissabecker2134
      @melissabecker2134 2 месяца назад

      @@thom1218
      Would two units tied to 50 amp hub solve the problem of starting a 2hp 230v water well pump?

    • @melissabecker2134
      @melissabecker2134 2 месяца назад

      If not, it sounds like my most assured to run my 2hp water well would be the 3800 with maybe an extra battery for running time?

  • @tonyinfinity
    @tonyinfinity Месяц назад

    I believe the reason the 30A plug shuts off power when you supply AC into the unit is because these companies have realized you can daisy chain the smaller units, so they figure people won't be buying the backup batteries they designed for the unit if you can just plug in a Delta Max you might have laying around to add to the capacity

  • @Trillville43
    @Trillville43 3 месяца назад +4

    I wonder was xboost on?

    • @Bowers31214
      @Bowers31214 3 месяца назад

      Hmm that’s something to consider

  • @AMXTomzo
    @AMXTomzo Месяц назад

    Test i like to see.........
    unattended solar charging, can i plug in nay brands battery with solar panels and never think about it again?
    thank you, love the video's and the work you put into them, hello from USA

  • @diskdrive123
    @diskdrive123 27 дней назад

    Me thinks you have X-boost enabled. This allows the voltage to drop when in overload, effectively soft starting large resistive loads. Obviously this is bad for motors/pumps because your under volting them. Turn x-boost off probably fixes it, or at least makes it a lot better.

  • @vic-wo7hb
    @vic-wo7hb 3 месяца назад

    Wow! The ultra did great for me, but can you guys try out the Etaker M2000? I would like to see the results of that unit

  • @beckerwholesale2913
    @beckerwholesale2913 2 месяца назад +2

    What do you gain (or loose)
    when you go to the pro 3?

  • @juanr.3314
    @juanr.3314 3 месяца назад

    One thing I’ve learned with this battery power station is that they are for low wattage usage or short term emergency situations…. Good product if you know when n how to use it correctly.

    • @francocastilloAR
      @francocastilloAR 3 месяца назад +2

      On the contrary. Everything he tested is high potency. Problems arise when you want everything at the same time.

  • @JamesAmbrose48
    @JamesAmbrose48 3 месяца назад +5

    Will Prowse also often had problems starting his car lift when testing power stations and inverters. I think car lifts have a much greater surge than people think.

  • @offgridgesertdwellers
    @offgridgesertdwellers 3 месяца назад

    I would like to see the Oupes Mega 5 tested in this same manner.
    Thanks in advance.

  • @mattman6199
    @mattman6199 3 месяца назад

    There was the compressor!! Well once anyhow 😂

  • @chaddoyle6911
    @chaddoyle6911 Месяц назад

    I want to run 240V 30A power tools with my battery solution, but it’s not clear to me what surges are fine or not fine. For me it will be a go / no go decision on purchasing from Ecoflow, so this video changes things. Can we a have follow-up on what’s going on here? I need to know.

  • @jamesc8453
    @jamesc8453 2 месяца назад

    Love your videos!!! Question? If I am using the DPU to power my critical circuits and I try to extend my battery longevity by also charging the DPU with the Ecoflow Duel Fuel generator will it stop powering my house? Same question with the Ecoflow 400 watt solar panel?
    I got confused watching this video

  • @MR_Garage
    @MR_Garage 3 месяца назад +1

    Inductive loads vs resistive loads. HUGE difference for an inverter / vastly different power factors. Example, a 2000w inverter can produce 2000W with a power factor of 1 and a resistive load. Move to an inductive load such as motors, shop equipment and such with a power factor of say .5 and the inverter would only be able to support say 800w under those conditions. Pretty normal.
    Very good to know the 240 out shuts down when charging. Deal killer for me. That is DUMB.

    • @gelu88
      @gelu88 3 месяца назад

      It's because the unit has 2 120v AC/DC inverters doing multiple roles. (in and out).
      But 240v out requires both, so ypure stuck.
      The solution is 3 separate inverter, which maybe should be a option in the future

    • @francocastilloAR
      @francocastilloAR 3 месяца назад

      @@gelu88 Don't be scared by the price when it goes on the market 😂

    • @gregmiller6826
      @gregmiller6826 3 месяца назад +1

      Still has 120v ac charging while using 240v ac out.

  • @kwas27
    @kwas27 3 месяца назад

    My guess is they oversize the battery and then the charging process and and the inverter are about 90% efficient and that would make sense of your 7.25 ohh kilowatts at the outlet. Is this is what they did I mean kudos to them 90% efficiency is really really good anyway. I'm wondering if if there is a way to check the capacity of the battery or would it only work with the ecoflow unit. Thanks for the video

  • @HieuHoang-py8oe
    @HieuHoang-py8oe 28 дней назад

    I'm looking to max out both solar charging inputs. What's the best panels with smallest footprint?

  • @reedyhopkins4099
    @reedyhopkins4099 3 месяца назад +2

    Concerning pass through: if you are connected to a generator to recharge battery/run devices, the 30 amp plug doesn't work/support? Thank you.

    • @ronbridegroom8428
      @ronbridegroom8428 3 месяца назад +6

      Yes the 30 amp plug on the front does work. If you use the AC input on the front, and set to Fast, you can input up to 1800 watts at 120 volts and get up to 7,200 watts out at 240 volts the only unit that can do this. If you are using the AC input on the side you have to input at least 7,200 watts for the 30 amp plug on the front to output power also

    • @AndyGwynn-r3s
      @AndyGwynn-r3s 3 месяца назад +2

      @@ronbridegroom8428 Yeah, it's weird that they didn't mention this. I watched another RUclips that was running an electric dryer, pulling over 6000 watts, simultaneously charging with the front 120V Ac input at about 1700 watts, and it worked just fine. It's odd that they weren't using the front AC charger.

    • @ronbridegroom8428
      @ronbridegroom8428 3 месяца назад +1

      @@AndyGwynn-r3s I have personally done exactly what you stated with my dryer and 120 volt input. I have done it with using the wall outlet and also the Vehicle to Load feature of my Ioniq5.

    • @dennischristians
      @dennischristians 3 месяца назад

      @@ronbridegroom8428 Thank you for the info. Makes sense as my switch was set to slow.

    • @BazBobDaddy
      @BazBobDaddy 3 месяца назад

      @@ronbridegroom8428 To be clear, if using the side AC charge port with the "EcoFlow AC Generator Charging Adapter with the NEMA L14-30P being plugged into a 240V source capable of 7,200W, that the front panel NEMA L14-30R outputs 240V at 7,200 in passthru and works? Also, does the 120V NEMA TT-R30 work as well with side AC charging on?

  • @Marvin_Neon_Playz112
    @Marvin_Neon_Playz112 3 месяца назад

    First time searching this topic then found the video

  • @qtrhors1
    @qtrhors1 2 месяца назад

    Well most people dont have a car lift so its a good unit for normal households . :)

  • @joshm3342
    @joshm3342 Месяц назад

    @:27 you said you would LEAVE A LINK BELOW for your original full review. I can't find the link. Goodbye.

  • @MsYouANDREATube
    @MsYouANDREATube 2 месяца назад

    Would love to have seen a dryer

  • @AnonymousUser_no_name
    @AnonymousUser_no_name 2 месяца назад

    I couldn’t find a video anywhere on whether this can cope with welding work. Will this work stably?!

  • @buntnik
    @buntnik 3 месяца назад

    Did you test how much charge it loses with no draw? 15% each day …

  • @allen35315
    @allen35315 3 месяца назад

    Is there a separate plug/cord for the high voltage PV?

  • @allen35315
    @allen35315 2 месяца назад

    I ran the 30amp to a transfer switch while plugged into ac..worked fine - what am I not understanding?

  • @tonyhernandez3433
    @tonyhernandez3433 2 месяца назад

    Yoo TSL. Which would be better in ur opinion for a sprinter van instal the…..
    Eco Flo power kit 5k or this ultra ??

  • @ronbridegroom8428
    @ronbridegroom8428 3 месяца назад

    What is the LRA of the lift? Strange that the F3800 could do this but the Ultra could not. Have you reached out to EcoFlow?

  • @sherman1118
    @sherman1118 3 месяца назад +2

    Can this charge my rivian r1t?

  • @Moes_Prep_and_Tech
    @Moes_Prep_and_Tech 3 месяца назад +1

    6:37 what adapter are you using to hook it up to the stove?

    • @TheSolarLab
      @TheSolarLab  3 месяца назад +2

      Its just an L14 - 50A from amazon!

  • @georgehewitt3516
    @georgehewitt3516 3 месяца назад

    I want to run three laptops and two tv's and a 120 v well pump when power out goes out What Ecoflow should i get?Thanks

  • @jimfields9491
    @jimfields9491 3 месяца назад +1

    So it doesn’t have pass through charging????

    • @TheSolarLab
      @TheSolarLab  3 месяца назад

      Not to the L14 generator plug

    • @MotorhomeMike
      @MotorhomeMike 3 месяца назад +4

      @@TheSolarLabSilver Cymbal channel (ruclips.net/video/2K9mlryo8lI/видео.htmlsi=NrJdgnNMjwWo0XHy) showed pass through working from front 120V AC input (not the side in/out port). So the DPU should be able take in up to 1800W (120Vx15A) from a generator while still outputting 240v to a home panel through the L14 port.

  • @dr.geraldgroves8883
    @dr.geraldgroves8883 3 месяца назад +1

    How'd the 3800 do in the home? Is it better with surges and the pro inside the home? Or is the 3800 better all the way around, more or less?

  • @HieuHoang-py8oe
    @HieuHoang-py8oe 28 дней назад

    How does it handle charging an EV?

  • @carterjohnson25
    @carterjohnson25 Месяц назад

    No pass thru to 240? Is that for real? Wtf

  • @cottoncb
    @cottoncb 3 месяца назад

    Will it start an AC

    • @criticalhadlock886
      @criticalhadlock886 3 месяца назад +1

      Ecoflow claims it will start a 3.5 ton AC. But I believe that is only if you have a soft start installed on it.

  • @Theoppositeofchaos
    @Theoppositeofchaos 3 месяца назад

    I really think car lift is an unfair load to the Power Station.

    • @alexdrum94
      @alexdrum94 3 месяца назад

      I dont understand why you feel this way considerings 2200w is nowhere near the peak of this unit AND the less powerfull Anker 3800 can run it just fine. There is clearly something odd internally going on with the Delta Pro Ultra.

    • @TheSolarLab
      @TheSolarLab  3 месяца назад +1

      How much is EcoFlow paying you? 👀

    • @Zerrudo_
      @Zerrudo_ 3 месяца назад

      ​@@TheSolarLab The 30A DC output is limited to 378W and not intended for home backup. Based on other review vids, it's designed to be stationary, with the option to be portable if needed. You'd have to get the Smart Home (sub) panel 2 to fully utilize the system.

  • @FatMat916
    @FatMat916 2 месяца назад +1

    Let’s see test on charging a Tesla with this unit.

  • @caolanwhoriskey1358
    @caolanwhoriskey1358 3 месяца назад

    Will you come back to cars

    • @TheSolarLab
      @TheSolarLab  3 месяца назад

      Yep! once this is running smoothly i will come back and have it be more for fun again and not stressful. Stress can ruin a good ting, I'm excited to find a happy balance!

    • @caolanwhoriskey1358
      @caolanwhoriskey1358 3 месяца назад

      @@TheSolarLab nice, good luck, thanks for the reply