Sir agr converter ko on krne k bad sardion mn bhee Frequency direct 50 py chale jae aur OL1 ka option aae to eske kia wajh hoge please guide kr dy jazakallah
Thanks for your comment. Dear sb sy pehly ap apny input k voltage check karain. Unmain kitna faraq aya hy. Phir us hisab sy setting karna pary gi. Wesy motor k bearing and short circuit wagera b check kr lain
Ye over current ka fault hy. Motor short ho uski wires apas main ya ground wire ky sath short honn. Ya phir apka inverter card khraab ho ya p2 group main motor rated Amp theek adjust na kiay hoon. Ya motor inverter sy ziada capacity ki ho. Ya acceleration time bohat km ho tb ye fault aata hy.
Sir i have istalled an invt 7.11 vfd install ki hy ja 545 10 modules k sath distance from vfd 110 feet 15 mint baaad ol1 error sho kr raha hy any solution motor bi teek hy 3hp 3phase
Asalm u Alekum Sir main Akbar Sir hamar inwatar oc3 ka fault bata raha agar ap rahenumi kar dein main wait kar raha hon sir humara pani ka bahot masla hai
Your videos are great source of information and really helpful. Thanks for all your hard work and time, really appreciate it.
My pleasure!
Allah ap ko bahut khush rakhe Meri Dua hai sir g
Thanks for your comments and appreciate
Great guiding bhai ji❤️❤️👌👌
Thanks
سر آپ کی بہت سی ویڈو دیکھی ہیں کوئی ویڈو bldc motor پر بھی بنایئں
پورے یوٹیوب میں جتنی گہرائ میں جاکر آپ نے بتایا ہے آور کسی چینل نے نہیں بتایا شکریہ
Dear name plate ki picture send kro.
سر انو رٹر میں o u 1 فالٹ کو کسی طر ح ٹیک کر سکتے ہیں
Thanks for your comment. I will upload next video about it very soon. Keep watching.
can we use VFD for BLDC sensor motor? Which VFD can drive 200W BLDC
Dear i will check for Brush less DC motor.
Sir agr converter ko on krne k bad sardion mn bhee Frequency direct 50 py chale jae aur OL1 ka option aae to eske kia wajh hoge please guide kr dy jazakallah
Thanks for your comment. Dear sb sy pehly ap apny input k voltage check karain. Unmain kitna faraq aya hy. Phir us hisab sy setting karna pary gi. Wesy motor k bearing and short circuit wagera b check kr lain
Bhi 7.50 hp submersibles moter 15.18 vfd ha or 14 585 wat ka penal han oL1 ka problem arhaa ha jis sa vfd tarip ho jati ha har 30 35 mint bad
Check this video. And set p2 group parameter.
ruclips.net/video/EjJzlNnhACI/видео.html
VERY NICE❤
Bahi Jan solar 700 volt K sat 220 wapda Sher hi sakti he ya Nahin
Dear itny voltage ky sath kabi experiment nhi kea.
Bhai hum 7.5 ki motar boor par istmal karna chahte hain neo setting kaise ho gi inverter ki
Dear check this video
ruclips.net/video/QMdO7IAOgVo/видео.html
Oc1 bary men b btaen
Ye over current ka fault hy. Motor short ho uski wires apas main ya ground wire ky sath short honn. Ya phir apka inverter card khraab ho ya p2 group main motor rated Amp theek adjust na kiay hoon. Ya motor inverter sy ziada capacity ki ho. Ya acceleration time bohat km ho tb ye fault aata hy.
Very nice
Thanks 👍👍
Sir i have istalled an invt 7.11 vfd install ki hy ja 545 10 modules k sath distance from vfd 110 feet 15 mint baaad ol1 error sho kr raha hy any solution motor bi teek hy 3hp 3phase
Check your parameter according to this video.
ruclips.net/video/QMdO7IAOgVo/видео.html
Asalm u Alekum
Sir main Akbar
Sir hamar inwatar oc3 ka fault bata raha agar ap rahenumi kar dein main wait kar raha hon sir humara pani ka bahot masla hai
In next video i will mention
Zbr 10 gaid ness
Thanks for appreciate. Keep watching 👍👍
LO error how to fix?
Dear OL ho ga. Overload ka.
Apki current range km feed hy. Output voltage km hain. Motor short ho sakti hy Acc time km feed hy
❤❤❤❤❤
Thanks 👍👍
Single phase our 3phase rakna kaisi hy
Check this video
ruclips.net/video/UQXw2ta_HHg/видео.html
Good
👍👍👍
Fuji ace drive OL1 how to solve
Drive not available
Vfd invt 380 3phase 2phase 380 coming 1phase 294 coming falt coming Uu
Dear check this video. Link 🔗 is given below 👇👇
ruclips.net/video/QMdO7IAOgVo/видео.html
Auto chlana ma koi masla to nai hota motor ko
Don't worry. it is safe
30HP ki moter par kitna KW set karna ha?
Ampares b bta den
23 KW
40 Amp
👍👍👍
Uu
sir g ap ka work shop kidr hi
Sir g war app nmbr pleaz
Lahore Pakistan
Pektri riset nahi ho rahi kese
Send a video on my what's app number. 03116073134. I will check
ye vfd ac to ac hy
Dear. Dc to Ac b ap use kr sakty hain
Aoa
W. S
No......,
Aadha jhoot hy aadha sach hy
Dear i have shared my experience. You can explain what is wrong??
Galat bata rhy ho aap
Dear i have shared my experience. If you know better anything share with me.
ا پ کی نمبر
What's app only
03116073134
Sir please WhatsApp number de do mujhe
03116073134
Very good
Thanks 👍