Troubleshooting Trane EEV and EVC Board

Поделиться
HTML-код
  • Опубликовано: 26 авг 2024

Комментарии • 56

  • @francolezzi6948
    @francolezzi6948 2 года назад +22

    *Used to supplement the up stairs when it gets hot outside this works very well and **Fastly.Cool** Also works good when the upstairs gets too hot in the Winter from the heater.*

  • @trickyanims7852
    @trickyanims7852 5 лет назад +4

    Had a TAM7 with the 10 red flash (superheat) fault. Great video! Read a interesting article suggesting the "SH" fault can sometimes be due to a dirty filter or evap coil.

  • @Powlashvac
    @Powlashvac 8 лет назад +2

    Holy crap that PSI dropped like a brick. Great video Zack

  • @ComfortPlusHeatingandCooling
    @ComfortPlusHeatingandCooling 8 лет назад +4

    Good video Zack! That boy brazes copper the way I weld steel lol.

  • @joshmassaro7333
    @joshmassaro7333 4 года назад +6

    Honestly I can't find any literature for trane. It is driving me nuts. They tell me to go online but all I find online is installation manuals.

  • @mrgreen9086
    @mrgreen9086 5 месяцев назад

    Worked on of these the day
    Had 3 green flashes (stage 2 cooling) and 7 red flashes (high superheat) put a jumper on open and test and pressures did not change.
    Going to be replacing the exv 😅

  • @rutico12
    @rutico12 3 дня назад

    We're I can download the PDF for troubleshooting? Thank you

  • @10rninjariderzx
    @10rninjariderzx 5 лет назад +3

    How much energy does an eev save you vs the replacement and service calls to fix it?

  • @adamspears3819
    @adamspears3819 4 года назад +4

    Thanks for the video.
    Do you know what 7 red fault flashes mean on that EEV control board?

  • @Jimddddd1981
    @Jimddddd1981 8 лет назад +8

    Electronic expansion valve? Is that shit really necessary? I'm sure the salesman who sold that system talked about all the "benefits" of the Trane system. What I'm sure he did not mention is that the cost of repairing the system negates the energy savings. I would never recommend this type of system.

    • @zacksintheshop
      @zacksintheshop  8 лет назад +1

      It does not appear it was needed. I don't really do these type either.

    • @321marshman
      @321marshman 6 лет назад

      Jim D they are kind of in the new inverter technology

    • @jonathanhale8388
      @jonathanhale8388 3 года назад

      They're great for efficiency. They're really not bad to diagnose or work on. The motor can fail but the valve itself is rated for practically the life of the unit. EEV and ECM all the way!

    • @NotOurRemedy
      @NotOurRemedy 3 года назад

      More reliable and efficient.

  • @joeschneider67
    @joeschneider67 4 года назад +2

    No way that EEV and circuit board fail at same time. That's easy fix by replacing everything. Am sure the problem was the EEV...more likely, if that unit has air flow problems ( low air flow ), the valve will be working hard to maintain refrigerant flow till collapse. I have see that issue very often.

  • @camronconlee944
    @camronconlee944 8 лет назад +1

    I actually really like eev's.... for refrigeration, not for a/c. I mean if you already have an automation system I figure why not, but for one split system it seems like overkill.

    • @zacksintheshop
      @zacksintheshop  8 лет назад

      I don't see too many problems with them either. Just a little overkill like you said.

  • @johnisraeljr5623
    @johnisraeljr5623 8 лет назад

    Great troubleshooting Zack!! Really enjoyed this video!!

    • @zacksintheshop
      @zacksintheshop  8 лет назад

      Thanks John, I wad glad I ran into this one

  • @Chris-zo9yy
    @Chris-zo9yy 5 лет назад +1

    I’m just wondering but if you couldn’t jump out the stepper motor and then determined the step motors resistance was off point, what led you to condemn the board? You shouldn’t be able to jump out a bad motor.

    • @Papasquatch73
      @Papasquatch73 3 года назад

      He said why 4:51

    • @jonathanhale8388
      @jonathanhale8388 3 года назад +1

      If you ohm it out and it ohms bad, it's a bad step motor in my experience.

  • @jamesrothwell1738
    @jamesrothwell1738 3 месяца назад

    What’s the name of that book?

  • @Bill_CBR
    @Bill_CBR Год назад

    I'm curious, where did you find the leak? Did you ever go back for that?

  • @Wisdomoftheair
    @Wisdomoftheair 8 лет назад +4

    High-dollar equipment but not a lot of quality in the installation. That strikes me as, odd.

  • @jimmartinez8977
    @jimmartinez8977 5 лет назад

    Really appreciated the vid! Thank you.

  • @wesjarrett7295
    @wesjarrett7295 3 года назад +1

    What will you charge me for a copy of your service book. My boss just threw me into this role and I habe no information available

  • @geekincognito
    @geekincognito 2 года назад

    I have the same unit. Getting 6 green and 4 red flashes while cooling. Any idea?

  • @jakimsmark
    @jakimsmark 29 дней назад

    I wanted to know where can I find which manual you have that is telling you wheat the ohms for the senders should be I don’t work on a lot of trains but when I do it’s usually the eev sticking but someone brought my attention to homing out senders and that’s how I came here so if someone can help me would be great for next one I come across I can check instead of thinking it’s the eev I usually test the open and close am that that usually let me know if pressures change or not

    • @zacksintheshop
      @zacksintheshop  24 дня назад +1

      It’s been a long time, but I probably found this information in the service facts for this unit

    • @jakimsmark
      @jakimsmark 22 дня назад

      @@zacksintheshopthanks for getting back to me someone else I talked to said I can find the ohm chart in google when searching ohming sensors for trane

  • @arthurhartwick7974
    @arthurhartwick7974 2 года назад

    Great video. I was working on one today. What are those round things you're using to read pressure?

  • @frankcloskey7789
    @frankcloskey7789 2 года назад

    Note : Trouble shooting is very important so is your sub cooling.8/7/2022yr

  • @chinopaiz1708
    @chinopaiz1708 3 года назад

    Do you have the E-manual for the control board and electronic tapper motor ..??

  • @THEMFORMATION
    @THEMFORMATION 5 лет назад +2

    How did you fit your meter leads in there to test the stepper motor? Mine wont fit

    • @amann910
      @amann910 4 года назад

      you can use small piece of thermostat wire in a pinch or get back probe kit for your leads

  • @achevalier111
    @achevalier111 6 лет назад

    Hey where can I find gauges like that? I don't know what to call them, pocket gauges?

  • @380Banshee
    @380Banshee 2 года назад

    That stepper motor tho, dip switches trane famous for those, program to the air handler type, weeeee, lol!!

  • @dirtydave2315
    @dirtydave2315 4 года назад

    That little sticker in the corner says the unit should not be taped up like that

  • @joeshearer1247
    @joeshearer1247 8 лет назад

    That suction line was horrible! Were you lucky enough to have that literature left for you?

    • @zacksintheshop
      @zacksintheshop  8 лет назад +1

      Yep it was on the unit. My phone was ready if not.

  • @mistyflorist5455
    @mistyflorist5455 6 лет назад

    good day sir. may i know how to get the app for checking the reading from a tablet and where to get the service handbook?
    i am a apprentice in air con and will be doing a presentation by year end and our guys wish to monitor the system wirelessly.
    pls advicr

  • @chrisd3399
    @chrisd3399 4 года назад

    This is literally what happen too me today !

  • @video-wt6de
    @video-wt6de 6 лет назад

    Hello how are you

  • @RobHVAC
    @RobHVAC 8 лет назад +1

    Nice trouble shooting.

  • @john7017
    @john7017 5 лет назад

    You can pull a Trane...

  • @mns.gh6432
    @mns.gh6432 4 года назад

    From Iraq so thnxs

  • @usahoangsatruongsa
    @usahoangsatruongsa 5 лет назад +1

    Sssooo the bottom line here is you misdiagnosed it. You blamed it on Trane EEV and control board ?? When you first check the standing pressure 50 psi didn't ring a bell ? When you test run in cooling mode (3:32) the highside pressure only 214 psi for a r410a system did not ring a bell ? and You blamed it on EEV and control board ? have ever heard of low charge? I know a heat pump equipped with EEV is not popular and not easy to diagnose it but atleast when you look at the gauge The high side pressure only214 psi did not tell you anything?? If you suspect a bad EEV (not open,stuck closed) then when you run the cooling mode the high side pressure should be MUCH HIGHER not 214 psi as shown in your video.

    • @adamcraig1568
      @adamcraig1568 3 года назад +1

      So before you attack Zack know your shit. System was running 100/300 in heating mode which in NC is very possible. In cooling mode we could obviously see a restriction. If your running cool mode in winter (November) than obviously in cooling your head pressure will be that low. Come on man. Hvac 101

  • @Bluecollarworkingman
    @Bluecollarworkingman 6 лет назад

    This is good.

    • @Bluecollarworkingman
      @Bluecollarworkingman 6 лет назад +1

      Changing the dipswitch to the wrong refrigerant and back, got mine going temporarily until i could get a new one.

  • @tomwardzala4240
    @tomwardzala4240 6 лет назад +2

    Piece of shit hyperion series units