  • In this HVAC Training Video, I Show How to Check the Charge and Add R-410A Refrigerant on an Air Conditioner that is Low. I Show the Procedure for Connection, Measuring, Charging R-410A Refrigerant, Disconnection, and Leak Testing at the Ports! Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    Our Tools!
    hilmor Scale: trutechtools.c...
    Manifold Gauge Set: trutechtools.c...
    hilmor Screwdriver: trutechtools.c...
    Refrigerant Charging Hoses: trutechtools.c...
    When Shopping on TruTechTools.com, Use our Promo Code: acservicetech for 8% off at checkout!
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos
    • R-22 and R-410A Operat...
    • Charging an R-410A AC ... R-410A
    • R-410A AC Unit, Checki...
    • Checking the Refrigera...
    • R-410A Charging and Re...
    • Charging R-410A Refrig...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicet...
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicet...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtoo...
    Refrigerant Charging Book and E-Book: www.acservicet...
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicet...
    Our Newest Articles: www.acservicet...
    Try our HVAC/R Quizzes! www.acservicet...
    Our Other Resources: www.acservicet...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicet...
    Our Tool List on Amazon: www.amazon.com...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtoo...
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.c...
    Apple Podcasts: podcasts.apple...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #r410a #airconditioner #airconditioning #measuring #measurement #low #procedure #hvacprocedure #refrigerant #r410a #disconnect
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Комментарии • 138

  • @wilfredovega577
    @wilfredovega577 2 года назад +11

    Once again an amazing demonstration of proper charging technics.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 2 года назад +6

    Even though im strictly commercial/ industrial.....instill enjoy your videos and instructional content......its all heat transfer at the end of the day and the basic principles still apply....Well done Craig...as always

  • @Vuratzkee
    @Vuratzkee Год назад +1

    Simple short video but very informative. For DIY people out there. It can save you a lot of money . Just give it a try yourself first and see if it gets better. If not. Seek the help of a pro. By watching this video, thank you for sharing information. Keep posting

  • @jonnykielbasa
    @jonnykielbasa 2 года назад +6

    Best Video on charging a system! I've seen Many and went to Tech School So this is your go to guide for anyone EPA certified to work on AC Units

  • @DavidTaylor-he7zl
    @DavidTaylor-he7zl Год назад +2

    I really appreciate your videos. As a newly graduated student of hvac I find your videos easy to understand and reassuring of procedures. Thank you. Keep them coming

  • @RadioChief52
    @RadioChief52 2 года назад +17

    I've always wondered why these analog gauges aren't made with the R-410 saturated temperature on the outer ring where you could read it more accurately. Put the pressure on the inside ring.

  • @pizzajoes2156
    @pizzajoes2156 3 месяца назад

    I agree.....this is probably the best video that explains the addition of refrigerant and also the subcooling and superheat concept. Thanks

  • @tinysand3517
    @tinysand3517 Год назад

    I do not know anything about ac, after watched his video I have confident I can upgrade my system. Thankyou very much Craig

  • @mpmfr
    @mpmfr 2 года назад +2

    I’m just a homeowner interested in knowing more! Love the videos Craig! Thank you!

  • @antoniolaracuente437
    @antoniolaracuente437 2 года назад +2

    thank you Mateo and thank you for these videos that you show on RUclips you are a blessing to most of us out here I'm from Jersey and I really appreciate what you're showing on these videos

  • @Joseph-vj2ph
    @Joseph-vj2ph 2 года назад +1

    You do an awesome job! Step by step. Way better than other videos I have watched. Keep up the good work.

  • @tecfriorefri
    @tecfriorefri 2 года назад +2

    This manifold is very cool

  • @nohmadbaker5449
    @nohmadbaker5449 5 месяцев назад +1

    Thank you for making this video. I really needed that lesson

  • @marshallnmoonshine
    @marshallnmoonshine 2 года назад +2

    Cleanest manifold ever. Haha.
    Thanks man, I love your channel.

  • @deltaf222
    @deltaf222 3 месяца назад

    This is so well documented & informative _ thank you Craig!!

  • @trompelemonde4728
    @trompelemonde4728 Год назад

    Seriously fabulous video, I am so pumped to finally understand what's going on here. THANK YOU!

  • @Billo1281
    @Billo1281 11 месяцев назад

    I’ve learned so much from you guys, thank you so much!

  • @martintamroon6854
    @martintamroon6854 Месяц назад

    You have been a big help

  • @joebird1400
    @joebird1400 Год назад

    All this new equipment is crazy

  • @davidnunez7889
    @davidnunez7889 Год назад

    Great video Craig it’s sad that I learn more from you than college. Keep up the great work and glad to see your subscribers climbing up.

  • @Владимир-д2п8й
    @Владимир-д2п8й 4 месяца назад

    I BOUGHT THESE CARDS FROM YOU ,HELP A LOT, THANKS FOR HTE WORK ,

  • @kennethlobo4420
    @kennethlobo4420 2 года назад +2

    Great video

  • @virbone7141
    @virbone7141 8 месяцев назад

    U R wonderful people helping the comfortable equipment technology to people

  • @DanO181919
    @DanO181919 2 года назад +32

    You are such a blessing to the HVAC world. Thank you for all you do!!

    • @acservicetechchannel
      @acservicetechchannel  2 года назад +2

      So Glad you enjoy the videos Danny!!!

    • @jollyscaria1922
      @jollyscaria1922 5 месяцев назад

      Very good welcome shering gues best wishes welcome..one point veary good careudfull R410 using methad thsnfor me allthe time ..

  • @jonathanraul4086
    @jonathanraul4086 2 года назад +1

    Thanks a lot. Great video once again. Keep up the great work

  • @brianmcdermott2430
    @brianmcdermott2430 2 года назад +1

    Great info. Craig. Thank you.

  • @bonnylasu7665
    @bonnylasu7665 11 месяцев назад +1

    Sir good day to you. I'm interested watching explanation for air conditioning. R22 refridgerant can be used in R32 CHIGO room air conditioner charging air conditioner?

  • @deanmartin1966
    @deanmartin1966 2 года назад +1

    Good video. Thanks for sharing. You always work on the nicest systems Craig.Lol

  • @MtPockets14U
    @MtPockets14U 2 года назад +1

    Like to see video to show people what happens when the charge 410a with vapor by not paying attention

  • @DavidHernandez-gt9bo
    @DavidHernandez-gt9bo 2 года назад

    Nice , once again spot on ! Solid techniques !

  • @peenopiani7209
    @peenopiani7209 Год назад

    Excellent sir.i got answer of all my questions🙏

  • @samuelnunez9521
    @samuelnunez9521 Год назад

    Super helpful thank you for this video

  • @mhamrahi
    @mhamrahi Год назад +1

    Also any reason you never use a flash charger on your vapor line for refrigerant refill, instead of opening and closing the valve multiple times? I know you talked about it but never used it

  • @mhamrahi
    @mhamrahi Год назад +1

    Craig, Lennox units don't have any target Subcooling on the sticker. How can we figure that out?

  • @chuck0837
    @chuck0837 2 года назад +1

    Thank you so much for these videos. They really help to understand the concepts.
    I have a question: We add R410 in a liquid balanced form, but I am curious if R410 leaks from a system over time while the system is not running, does one or the other (R32 or R125) leak out disproportionately and imbalance the function of the gasses and cause a loss of efficiency ?
    If that was so should the system be evacuated and new refrigerant installed ?

  • @jonfitz8280
    @jonfitz8280 Год назад

    You have to have a low loss fitting with all or just this

  • @mitchc1263
    @mitchc1263 2 года назад +1

    The way I hook up the guages.
    Open suction side guage, close liquid side. Connect suction hose and let it bleed through charging hose and then close charging hose ball valve. Open liquid guage to bleed from suction side, then close liquid ball valve. Connect liquid line hose. Close guages and open liquid ball valve. Definitely no air getting in because the system pressure is pushing air out as you're connecting Hoses.
    Any thoughts or objections? The way taught in school is sort of silly to me. So I do it opposite.
    I use ball valve low loss fittings. Idk if this would work with his fittings in the video

  • @bobbyburt3636
    @bobbyburt3636 10 месяцев назад

    Is it normal for the suction side to be high if the compressor is not running?

  • @davidberger4726
    @davidberger4726 Год назад

    If you have a leak? How do you know if your blend is correct ?????

  • @briekhnaa
    @briekhnaa Год назад

    Hello. Why did you purge at yellow hose near the cylinder and not on other end ,near the manifold? Refregerant comes from cylinder and push air , in yellow hose , towards the distal end

  • @fisforfriendship6093
    @fisforfriendship6093 11 месяцев назад

    is delta t not required when dealing with txv systems?

  • @jfelshaw
    @jfelshaw 2 года назад +1

    Why don't you use one of those quick charge vaporizers?

    • @acservicetechchannel
      @acservicetechchannel  2 года назад

      you can just charge a little at a time to avoid damaging the compressor.

  • @stevee7774
    @stevee7774 2 года назад +1

    R Fortinay!!!

  • @mrbiglungz1789
    @mrbiglungz1789 Год назад

    Isn’t that around 312psig on the high side pressure?

  • @sergiodoordie319
    @sergiodoordie319 Год назад

    I'm getting those gauges man

  • @raymondperez8182
    @raymondperez8182 2 года назад +2

    Also what if you just have gauges and not those clamps to put on your vapor and liquid lines ? Could you make a beginner video I feel like this is for techs with all the gadgets

    • @paulrozinski1488
      @paulrozinski1488 2 года назад

      This channel does have a lot of other videos targeted to beginners. His books are also fantastic for beginners. Believe it or not, what he’s showing now IS the minimum amount of test equipment needed to do DIY service. They’re a good investment considering how many sketchy service companies are out there. I’ve found many of them! 😞

    • @antoniolaracuente437
      @antoniolaracuente437 2 года назад +2

      that's what I'm saying he gets all these tools for free I can't afford them

    • @sawdust85222
      @sawdust85222 2 года назад +4

      @@antoniolaracuente437 Not to be a jerk but it makes zero deference how a persons acquires the tools. If you don't have the tools, how do you expect to do the job?

    • @raymondperez8182
      @raymondperez8182 2 года назад

      @@sawdust85222 you don’t need a scale or those clamps . That’s extra gadget shit you get when you get money but every technician starts off with his basic gauge set

    • @sawdust85222
      @sawdust85222 2 года назад +3

      @@raymondperez8182 If you don't have the " extra gadget shit" how do you measure subcooling and superheated? Or how much refrigerant you're using? Or do those things not matter?

  • @namle-br8ju
    @namle-br8ju Год назад

    many thanks for sharing and showing this video. just one question about the super cooling, your machine has shown the target super cooling value is 9.7, but my machine does not show this SC value, where can I get this value? And where do I get the line temperature reader?

  • @xdropthatx
    @xdropthatx 2 года назад +2

    Should you charge by what it says on the nameplate (indoor txv subcool) or by what the chart says in the inside of the panel?

    • @acservicetechchannel
      @acservicetechchannel  2 года назад +1

      you would need to check and see what metering device is at the indoor coil. if its a txv, use subcoolung. if its a piston, use total superheat, thanks!

    • @caru3257
      @caru3257 2 года назад

      Maytag has charts based on liquid line temperature.

    • @randallwaters4273
      @randallwaters4273 2 года назад

      Yes and only by the chart..ps best way is approach method not subcooling

  • @REDRUSSIA0587
    @REDRUSSIA0587 2 года назад +1

    Clean filter, new coil what would cause a 30 degree delta T?

    • @acservicetechchannel
      @acservicetechchannel  2 года назад

      Low indoor airflow. check the duct if its too small or a low blower speed, thanks!

    • @REDRUSSIA0587
      @REDRUSSIA0587 2 года назад

      @@acservicetechchannel appreciate it figured so

  • @williamfeng6499
    @williamfeng6499 2 года назад

    I wonder is the subcooling is changed by the outdoor temperature. There has a subcooling rate table, is the table is not useable? Is the subcooling always need to be kept at 8?

  • @raymondperez8182
    @raymondperez8182 2 года назад +1

    I’m confused because you had your vapor and liquid line lever open ? Wouldn’t you need the closed during purging ?

    • @MaMa-qh4dy
      @MaMa-qh4dy 2 года назад +1

      The unit was NOT running while being purged. Thus, no liquid refrigerant could be sucked into vapor line and then on to compressor.

    • @raymondperez8182
      @raymondperez8182 2 года назад +1

      @@MaMa-qh4dy appreciate you a lot for this mamma makes total sense now !

  • @paulrozinski1488
    @paulrozinski1488 2 года назад +1

    What happened to the in-line vaporizer that you’ve shown in so many other videos ??. I see that you’re showing a new Hilmor set-up. I don’t know about this one, I see a lot of plastic on that manifold gauge set . From what I see, it just screams “cheap”.

    • @bobbycrosland9906
      @bobbycrosland9906 2 года назад +1

      Been using the same setup for about 10yrs, drops, weather and all it's the most accurate and durable I have used. I have Joblink kit, Sman, even the Elitetech digital set which is the best digital set by far but I prefer the setup he is using in this video.

    • @bobbycrosland9906
      @bobbycrosland9906 2 года назад +1

      Also that's an iron body these sets, gaurges are covered by proactive drop proof rubber, looks plastic but actually no plastic on this set

  • @kevinpearce3281
    @kevinpearce3281 2 года назад +1

    So… why can’t I add r410a into the high side. Is it just because the pressure from the system is to high and it won’t come out of the bottle.

    • @duganfr
      @duganfr 2 года назад +1

      Yes. Pressure is higher than bottle.

  • @michaeldreves5072
    @michaeldreves5072 2 года назад

    Can you safely pump down a 410a system and if so what do you do if it's a brand new 410a system and you try to pump it down and the pressures are coming down but than it makes loud swooshing sound and pressures claim back up quickly

    • @randybobandy9828
      @randybobandy9828 Год назад

      Are you pumping down a regular unit or a mini split?

  • @ChileVerdeDavid
    @ChileVerdeDavid 2 года назад +1

    How many times have you guys uploaded this video?

  • @ejohnfall
    @ejohnfall 2 года назад +1

    Thank you again for good information
    I have questions what the perfect pressure on R22 system when you connect your gauges just refresh memory

    • @Mridgwell
      @Mridgwell 2 года назад +1

      Do you mean static or running , what’s the outdoor temp what’s the indoor temp ?

    • @ejohnfall
      @ejohnfall 2 года назад

      Running temperature 89out and 78 inside

    • @sawdust85222
      @sawdust85222 2 года назад

      Honestly, pressures are not all that important. What you really should be after is the saturation temp. There are a lot of variables when it comes to operating pressures.

    • @Mridgwell
      @Mridgwell 2 года назад

      @@ejohnfall 75 psi

    • @Mridgwell
      @Mridgwell 2 года назад

      Think your super heat and sub cool is what's important, not everything will always be text book perfect but majority of 410 systems if you have target sub cool your good to go.

  • @anthonybarragan1687
    @anthonybarragan1687 Год назад

    Just one question, did you put your high side gauge on the access port of the discharge line vapor or the discharge line liquid line after the condenser???

  • @pana5075
    @pana5075 Год назад

    No se debe botar el gas refrigerante al ambiente y no es buena práctica de refrigeración hay otra forma para evitar la purga de gas

  • @jerrellstrawn6409
    @jerrellstrawn6409 2 года назад +1

    What is the name of the slider app you used?

  • @harh3101
    @harh3101 2 года назад

    Please disregar my previous comment, that was for the add on glasses.

  • @krishnarajachuthan3660
    @krishnarajachuthan3660 2 года назад +1

    2

  • @butlerstouchHVAC
    @butlerstouchHVAC Год назад

    11:07 you add freon through the blue hose?

    • @Cosmo95_
      @Cosmo95_ Год назад +1

      When system is running yes.

  • @reyrey9634
    @reyrey9634 2 года назад

    What if you use a liquid to vapor adapter/ vaporizer.. Do you still have to throttle the 410 into the system?

    • @randybobandy9828
      @randybobandy9828 Год назад

      Isn't that only needed for minisplits since most of them only have a connection port on the vapor/low pressure side?

  • @fabiodarocha2842
    @fabiodarocha2842 Год назад

    I lost my EPA 608 certificate.Does anyone here knows how to obtain a copy ? I have searched EPA site to no avail.

  • @kenshofalco8326
    @kenshofalco8326 2 года назад +1

    So the 7.6 degree's subcooling on the condenser's tag is the minimum amount of subcooling needed. I have a question, I hope you read this. How many degree's difference should there be between ambient temps and condenser refrigerant temp? Or should this just be ignored?

    • @DanO181919
      @DanO181919 2 года назад +4

      @ 8:33 it shows a target of 9.7 degree sub-cooling. You have a +\- 3 degree sub-cooling. It’s probably better to go over a little to allow for refrigerant loss due to connecting/disconnecting your gauges. You ask about CTOA (condensing temperature over ambient) it all depends on the unit. Rule of thumb is your older units have a 30 degree CTOA and the newer (high efficient) units could be as low as 15 degree CTOA.

    • @kenshofalco8326
      @kenshofalco8326 2 года назад +3

      @@DanO181919 Thank You. I thought it was 7.6... My bad!

  • @Beariam24
    @Beariam24 2 года назад

    Would this still be the same if the internal duct had a restriction on the intake side of the unit?

    • @zippythechicken
      @zippythechicken 2 года назад +1

      a clogged filter or one with too high a rating can result in you overcharging to compensate so check that first

  • @nidhisahu3579
    @nidhisahu3579 2 года назад

    Pleas help

  • @mikev.1034
    @mikev.1034 2 года назад +2

    👍🤘🤙

  • @rafaetkhanrk6475
    @rafaetkhanrk6475 Год назад

    I'm Air Conditioner maintenance technician from Bangladesh? I am interested to work with you please reply me.Presently HTMl is engaged in hotel management in Saudi Arabia. FROM TTES Air Conditioner maintenance

  • @wadysrodriguez3756
    @wadysrodriguez3756 2 года назад

    Sorry my friend lm dont know to much about the refrigeration but in my opinion you are think its so easy understund what ever you explain i say notI desaproval totally your video thanks

    • @randybobandy9828
      @randybobandy9828 Год назад +1

      That's a YOU problem.

    • @wadysrodriguez3756
      @wadysrodriguez3756 Год назад

      @@randybobandy9828 no no it is not only my problem its your problem too because I talk you because its you have channel in you tube what its your grow? Thinking about that sorry if I botter to you

    • @randybobandy9828
      @randybobandy9828 Год назад +1

      @Wadys Rodriguez I can tell by the way you type that you have issues with the English language. This guy's videos are concise and easy to understand. You can't expect to know what he's talking about as a person who isn't familiar with HVAC. Like I said, it's a you problem.

  • @randallwaters4273
    @randallwaters4273 2 года назад

    Let me help you...1st. The system wasn't low..you added refrigerant and made your suoerheat go down .if it's 77 inside you should have MORE suoerheat..if it gets a q10 inside and 101 outside ,you will have NO superheat putting the compressor in danger...suoerheat ensures 100 percent vapor..your coil temp was 35.too low..you wasted time and charged a homeowner to get minimal or no reward

    • @acservicetechchannel
      @acservicetechchannel  2 года назад +1

      This system had a TXV so we use subcooling to charge. Superheat is checked to make sure the TXV is operating properly. If you try to set these systems using superheat, they will get overcharged. On a system with a TXV, the indoor coil sat temp depends on the indoor air wb temp, thanks.

    • @anthonylasassa9679
      @anthonylasassa9679 2 года назад

      Youre right with a warmer return temp youll have higher superheat even with a txv. Also forgot to mention why he's adding in the first place. If it's low, perform a leak search and repair the leak. But it's OK all of these home owners trying to charge their own units is gonna make us a lot of money when they end up having to call us anyway.

  • @harh3101
    @harh3101 2 года назад

    Why so much freaking lip service, I don't have the time nor the patience.Buzz off

  • @nidhisahu3579
    @nidhisahu3579 2 года назад

    Hindi language sir

  • @berhanusisay3588
    @berhanusisay3588 10 месяцев назад +1

    The steps are really amazing.

  • @WESK18
    @WESK18 Год назад

    how do I calculate the required r410 on an empty 4-zone mini split 36kbtu, Suction OD is 3/8 and Liquid OD is 1/4, I have 82ft total for all 4zones but not sure if I need to multiply this number by 2 because each set has two lines, if so then its 164?

  • @JoeSmith-um2sg
    @JoeSmith-um2sg 2 года назад

    Please make content with commerical RTUs! there is NOTHING good available

  • @william-feng-007
    @william-feng-007 2 года назад

    why do you think the subcooling should be 8? if this system has TXV, the subcooling is variable. only the superheat is stable. could explain this?

  • @Hopefullymarried
    @Hopefullymarried 2 года назад +1

    Those Hilmar gauges are nice !!

  • @testtesting2868
    @testtesting2868 Год назад

    Excellent!

  • @maziarkhanlari7279
    @maziarkhanlari7279 2 года назад +1

    Why you enter liquid to system?
    We are suppose to inject vapor because of protecting compressor

    • @marty2958
      @marty2958 2 года назад +2

      R410A is a blend of refrigerants so to keep it whole you add as a liquid

    • @caru3257
      @caru3257 2 года назад

      R22 is supposed to go in as vapor but not R410A.

    • @maziarkhanlari7279
      @maziarkhanlari7279 2 года назад

      @@caru3257
      Thanks a lot buddy