DESIGN OF BOUNDARY ELEMENTS: FROM ETABS TO MANUAL APPROACH- LIVE SESSION | ilustraca | Sandip Deb

Поделиться
HTML-код
  • Опубликовано: 11 дек 2024

Комментарии • 54

  • @RachidBentafat-i7p
    @RachidBentafat-i7p Год назад +1

    Very interest topics for daily structural engineers activities

  • @maheshtelange5132
    @maheshtelange5132 3 года назад +2

    This is grate platform where you get very grateful content. Thank u sir.

  • @83vornchanveasna34
    @83vornchanveasna34 Год назад +1

    Thank full Sir, form Cambodia 🇰🇭

  • @shareqinamdar9211
    @shareqinamdar9211 3 года назад +2

    Awesome session conducted in depth... Waiting for future sessions as well.

  • @mdazadrahman4192
    @mdazadrahman4192 2 года назад +1

    Well defined interactive session ever i had seen in RUclips. Sir, kindly make a video on Foundation Design for ShearWall and Concept using SAFE software. thanks a lot sir.

  • @kariukijosphat7523
    @kariukijosphat7523 2 года назад

    Best tutor ever

  • @suhaibkhan7356
    @suhaibkhan7356 Год назад

    very well you have explained i need this kind vedio to watch

  • @vpconsultants3660
    @vpconsultants3660 2 года назад

    Good work Sandeep..

  • @onearth2013
    @onearth2013 3 года назад +1

    Excellent sir

  • @rcbsht9644
    @rcbsht9644 2 года назад +1

    It was very helpful. I wash you had designed columns beams and slabs

    • @rcbsht9644
      @rcbsht9644 2 года назад

      Sir do you have any detailed video on design of beams and columns?

  • @vpconsultants3660
    @vpconsultants3660 2 года назад

    Very good excel sheet prepared by mr.siddique

  • @PoojanMistry
    @PoojanMistry 2 года назад +2

    how to provide shear reinf. in BOUNDARY ELEMENTS?

  • @HERE_I_AM_LES10
    @HERE_I_AM_LES10 6 месяцев назад

    Depth info. Thanks

  • @kato_emmanuel
    @kato_emmanuel 3 года назад +1

    Thank you sir

  • @vpconsultants3660
    @vpconsultants3660 2 года назад

    Axial force C and T with Pu shall be more than 4000kn as you are using BE results..
    I feel flexural moments and axial force shall be used rather than BE details since we are cross verifying the BE details of etabs

  • @giftsonsamuel2627
    @giftsonsamuel2627 3 года назад +1

    Hi.. great job..for core or C shaped shear walls. Why do we assign different piers even though they act combined. Like we connect rebars of the wall at the junction.

  • @suhaibkhan7356
    @suhaibkhan7356 Год назад

    In 32:35 time you have mention d1,d2,d3 , IT SHOULD BE DEPTH ALONG THE LENGTH OF WALL NOT WIDTH OF WALL , D1 ,D2 D3 WILL BE ALONG MAJOR MOMENT AND PERPENDICULAR TO X-X AXIS

  • @AkashSingh-su7nj
    @AkashSingh-su7nj 2 года назад +1

    You or anyone who made this spreadsheet, have inserted the formula of alpha 5 is incorrectly. Makesure, it is written as (phi/(2*beta)). because actually value according to my calculation is coming out to be 0.05053 not 0.0719

  • @akhileshgupta8342
    @akhileshgupta8342 Год назад

    your videos are very much helpful...Are you familier about the problem while designing shear wall?---Design Inadequate: Shear force exceeds maximum allowed at bottom /top of pier leg...Could you make video about it?

  • @krishnakantkarekar7760
    @krishnakantkarekar7760 Год назад

    Good video thanks

  • @jaydoshi5309
    @jaydoshi5309 7 месяцев назад

    What does PU in flexural design means?? If Total Pu is considered from Boundary Elements

  • @VenkateshMithran
    @VenkateshMithran Год назад +1

    Bro in which organisation you are working for? Really you are a great resource for that company.

    • @ilustraca
      @ilustraca  Год назад +1

      Can't say here😅😅...but thanks a lot for your appreaciation

    • @VenkateshMithran
      @VenkateshMithran Год назад +1

      @@ilustraca currently I am working in a company we are doing us projects. This is my first company straight away I am doing us projects without any knowledge. Struggling day by day because it is completely different from Indian projects. Here we don't have a great resource like you. Only very few people have much experience they too don't know how to teach but they have knowledge. Feeling sad. After a long gap I joined in the organisation before that I was worked in different field. So struggling a lot to learn. Do you any advice for a people who has just starting out?

    • @ilustraca
      @ilustraca  Год назад +1

      You have to learn by yourself... keep learning and don't lose trust on u

    • @VenkateshMithran
      @VenkateshMithran Год назад

      @@ilustraca thanks for your hopeful words bro

  • @binsabiravlogsuk6050
    @binsabiravlogsuk6050 Год назад

    It was really fruitful session, but i had some doubts....
    1.Shear reinforcement/rebar given in the etabs is applicable to the boundary element portion or web area as we are getting 3500 mm2/m.
    2. If main R/f is higher side i.e 3.4%, and the extreme fibre stress is more than 0.2Fck, so how can we provide the boundary element.

  • @aslshining1
    @aslshining1 9 месяцев назад

    is it coupled shear wall design ,sir?

  • @anastaha2438
    @anastaha2438 9 месяцев назад

    Hi engineer, can you please show if the boundary element takes the enlarge shape, how to draw the enlarged shape

  • @aldiputra9236
    @aldiputra9236 10 месяцев назад

    Dear Sir, How we determine reinforcement rebar in the Side of raft foundation..please inform me if you have any references..thank you

  • @aldiputra9236
    @aldiputra9236 10 месяцев назад +1

    Sir, thank you very much😂😂

  • @nageshghadge664
    @nageshghadge664 3 года назад +1

    In the formula you have written AST/(tw*Lsw)

    • @ilustraca
      @ilustraca  3 года назад

      yes, it will give you reinforcement ratio, multiply is 100, u'll get it in percentage

  • @santoshbasnet9950
    @santoshbasnet9950 2 года назад +1

    can you please check the value of alfa 5 which is incorrect. The value must be around 0.0505

    • @ilustraca
      @ilustraca  2 года назад

      yes.. there was some mistake

  • @aldiputra9236
    @aldiputra9236 10 месяцев назад

    Sir, can you see row table (G-111)..is my equation right??
    My input
    Ac=(450x300)-1080
    Asc=1080 mm2
    But when I input the result G-111 = 1789.83 not same with your result = 1520.16

  • @niranjanshrestha1147
    @niranjanshrestha1147 Год назад

    while calculating λ we usew the total Lw=2310, But for calculating you have used Lw=1410 mm i.e length of web only. IS it correct.

  • @nageshghadge664
    @nageshghadge664 3 года назад +1

    Sir how did you came to know that the %0.97 is the reinforcement in web

    • @ilustraca
      @ilustraca  3 года назад

      check the previous video on Shear wall design please

  • @Er_sanjay_blogs
    @Er_sanjay_blogs 3 месяца назад

    Will you provide the excel sheet?

  • @lalitbhandari9632
    @lalitbhandari9632 3 года назад +1

    Thanks for the informative session. I have one question, when you distribute the total load of 4200 kN to web area and boundary element, you got 2754 kN for web area but etabs desgin the web area for 830 kN axial load only. Why there is a difference in the axial load??? please reply

    • @ilustraca
      @ilustraca  3 года назад

      ETABS has some conservative approach... it used to take complete axial load on the boundary elements

  • @josesalazar4684
    @josesalazar4684 4 месяца назад

    can you provide this excel sheet?

  • @harshaldalal9765
    @harshaldalal9765 Год назад +1

    Good day, i know its quite late comment after your post of this video. But, i have prepared excel sheet and calculated the data which u input in the video. I found some mistakes in excel sheet formulations which are as follows.
    (1) In case 2, value of a4 (alpha) is not correctin your sheet.
    (2) In case 2, value of a5 (alpha) is not correct in your sheet.
    (3) In last section, short column design Pu value is not proper in your sheet. Please check and correct me if i am wrong.
    Regards.

    • @ilustraca
      @ilustraca  Год назад

      Yes yes..

    • @ilustraca
      @ilustraca  Год назад

      Those were discussed earlier in our groups... kindly correct those.

  • @AmulyaRajbhar
    @AmulyaRajbhar 10 месяцев назад

    Height of the wall - 3000mm . Is it correct ? 🤔 Or we have to take full height of wall !!

  • @chiluvuritrilokraju
    @chiluvuritrilokraju 3 года назад +1

    Max limit of comp stress 0.2fck
    More than 0.2fck What is max limit of comp stress

    • @ilustraca
      @ilustraca  3 года назад +1

      0.446fck.. though it won't be needed.. once you found that the Percentage of reinf. is going more than 2.5-3% it is better to increase the size of the shear wall or the boundary element.

    • @chiluvuritrilokraju
      @chiluvuritrilokraju 3 года назад +1

      @@ilustraca your explanation is excellent Tq, please make a tutorials safe foundation raft foundation & pile cap design & punching shear reinforcement designed in raft

  • @fazilpatel8723
    @fazilpatel8723 2 года назад

    Please share that excel.