  • @joseflandestorp3304
    @joseflandestorp3304 6 месяцев назад

    I'm designing components for high volume manufacturing (>100,000 pcs/y), so we have to rely on process capability for quality assurance. What are your thoughts on the use of MMC/MMB or envelope, in combination with process capability? Is it feasible or not?

  • @emincavlan4457
    @emincavlan4457 6 месяцев назад

    So it means, I will add bonus tolerance to position tolerance(0.05 mm) , after datum B and and C size measuring. For example if datum B size is 25 mm I will add 0.05 mm. If datum C size is 30 mm, I will add 0.1 mm. I measure feature itself as 10 mm, I will add 0.1 mm. In final condition it has 0.05 + 0.05 + 0.1 + 0.1 = 0.3 mm position tolerance. Is it correct?

    • @이종대-u1n
      @이종대-u1n 2 месяца назад

      No additional tolerance occurs on datum feature B and datum feature C where MMB is applied.

    • @이종대-u1n
      @이종대-u1n 2 месяца назад

      No additional tolerance occurs for datum feature B and datum feature C where MMB is applied. In this case, the Position tolerance becomes 0.05+01=0.15.

  • @chrmeiss67
    @chrmeiss67 7 месяцев назад

    May be datums B and C are equal: A | (B-C) MMC