Good morning sir .. FD compartment jab hum open karegei to air bleed valve close ho jata hai.. Aur jab compartment close karegei to air bleed valve open open ho jata hai.. Aisa kyo.... Please reply sir..
Air bleed means air remove from windbox and another function is that if plant trip then CO gas having higher density which removes from this bleed valve, I'll make seperate video on this topic as soon as possible.
Sir Bahut achhe se smjhate ho but ek or request karunga ki aap ye bolte ho ki ye laga hota hai to plz uske bare me ye bhi batayen ki kyon laga hota hai or nahi lagane se kya hoga........Ek aap video banaye jisme working of power plant ho...
Bhai....forward feed evaporator backward feed me bht confusion hoti hai...kab backward use karna chayie... Viscous ya phr cold feed hai to ku backward use karte hai vertical tube agitated type kb use karte hai please samjhaaye
Sir, Please make a video on Pressure Reducing Desuperheater, explaining the terms, Blending, Dumping, condensate formation etc., Thanks in advance sir.
If we provide at top side then heat transfer rate is more in top side, so cooling water gain heat and become as higher as steam temperature so half bottom if these hot cooling water circulated the heat transfer rate is negligible, so to proper heat transfer in Condenser, firstly water provide from bottom side some amount of heat absorbed after that top half remaining absorbed.
Condenser ek closed type of heat exchanger Device h jaha heat Ka exchange krte h, condenser may be classified according to their use like ACC where air is used for heat exchange & Surface Condenser where water is used for heat exchanging.
Because we only remove latent heat of exhaust steam in condenser, if exhaust steam having higher temperature (means loss of Turbine efficiency) then this delta temperature increases, so we design condenser only for removing such a latent heat means both steam and condensed water having same temperature only phase change after cooling in condenser. This 10°C is constant means if more heat available in steam which is not condensed in condenser so the accumulation of non condensing gas increases which drops the vacuum so we takes action on Operation. For Turbine best efficiency we have restricted this 10°C value. Thanks
The whole kinetic energy of steam is not utilised during turbine rolling, so due to accumulation of these energy gradually increase of temperature and if synchronisation done then proper utilisation of kinetic energy by turbine, so this temperature start decreasing, I'll make seperate video on this topic.
Dear if hotwell level high it means the space in condenser is reduced for condensing the exhaust steam, so accumulation of non condensing gas increases it means vacuum drops, in second condition if hotwell level low it means shortage of water at suction of CEP Pump which is Reason of cavitation in pump, ultimately damage of pump so to avoide this type of happening always we maintain hotwell level. Thanks
In between surface condenser and vapour condensate tank their is baromatric leg to maintain the vacuum inside the surface condenser so if it not maintained properly then vacuum breakdown will occur also vapour condensate pump will run dry. Also we have to maintain oxygen content of condensate because it will cause corrosion, for more information please refer HEI standard for steam surface condenser where they have mentioned 7ppb to 14 ppb oxygen content.
Water circulation kaise hota h sir cfbc boiler mei plz help me sir.....eco ,riser drum downcomer,evap downcomer, screen downcomer,....yeh sb mei kaha se water or kaise flow krta h plz help me sir
Dear Sir please tell me why we maintain the hotwell level is 50 % and external cold water source of condenser during the process (for condensing purpose )
If hotwell level maintain high it means this water tends to occupy the area where steam condensation which causes drop in vacuum, if water 20% or below the amount of water at pump suction side reduces which is reason of cavitation, and external cooling system is required for condensing the exhaust steam.
Ye parameter volume of steam occupied in surface condenser and we rejecting only Latent heat so if we increase temperature it means Condenser volume is smaller in size so volume for exhaust steam is less to avoid this we maintain always temperature difference 10°C maximum.
Sir AAP bht ache se smjahte ho bht acha lga condenser ka video ☺️
Nice information sir...
Thanks dear
Good morning sir ..
FD compartment jab hum open karegei to air bleed valve close ho jata hai.. Aur jab compartment close karegei to air bleed valve open open ho jata hai.. Aisa kyo.... Please reply sir..
Air bleed means air remove from windbox and another function is that if plant trip then CO gas having higher density which removes from this bleed valve, I'll make seperate video on this topic as soon as possible.
OK sir....
Very nice explanation sr
Thanks dear
Very nice Tq sir bhaut Ache se samj aaya 🙏🏻🙏🏻🙏🏻
sir you r great. Really appreciate your effort.
Well done!
Thanks a lot
Thanks Sir fr the Info.. 🙏😊
Most welcome dear ♥️
Please add the video specially for evaporative condenser.. sir
Well explained sir... thank u ..🙏🙏
Most welcome dear ♥️
Good explained 👍
Thanks a lot
Vaccum pump pr video bnaye sir
Sure dear I'll make
@@PowerPlantDiscussion sir mere yahn pr Vaccum pump lga hua h
great initiative, great explanation
Thank you so much
Sir jet condenser bhe bata dejiya 🙏🏻🙏🏻pls sir 🙏🙏🙏
Very nice sir 👌👌👌
Sir kya chiller ke condenser me bhi refrigerant ka latent heat hi reject karvate hai?
Condenser ke andar entropy kam hogi ya jayeda hogi sir so please tell me
Very good persecution
Thanks a lot
exam se 2 ghante phle notes banane ka alag maja hai
explain with drawing and actual its very easy to understand
Very nice sir
Thanks dear
very very good sir
Thanks dear
Nice
What is the mame of centrifugal compressor having 4suction and one discharge?
Badhiya bhaii
Thanks
Thank you sir.... Plz condenser ke formule pr v video bno sir
Today I'll upload on Calculation of quantity of cooling water inside surface condenser
Sir Bahut achhe se smjhate ho but ek or request karunga ki aap ye bolte ho ki ye laga hota hai to plz uske bare me ye bhi batayen ki kyon laga hota hai or nahi lagane se kya hoga........Ek aap video banaye jisme working of power plant ho...
Sure dear m trying to provide whole process in one video
Sir please explain start up procedure for steam turbine's.
Sure dear I'll make
Bhai....forward feed evaporator backward feed me bht confusion hoti hai...kab backward use karna chayie...
Viscous ya phr cold feed hai to ku backward use karte hai vertical tube agitated type kb use karte hai please samjhaaye
Sir, Please make a video on Pressure Reducing Desuperheater, explaining the terms, Blending, Dumping, condensate formation etc.,
Thanks in advance sir.
Dear sir can you give information about, how to calculate heating surface area and how to know, how effectively heating surface is working...
Thanks a lots sir
Most welcome dear
Very good sir g
Sr main cooling water pump ka pressure kitna hota h
Dear it depends on designing normally seen 2.5 kg/cm2 to 3.5kg/cm2
Verry... nice sir
Thanks dear
Sir spray dryer absorber par video bnao...mass balance
Or rotary kiln energy balance
Sir condenser me laga rapture disc kiss condition me fatata hai ek vedio banaye
Sir ACC type ko bataiye isme thoda function change rehta hai
Tq for good video sir
Most welcome
پلیز کنڈنسر کی ٹائپ بتائے Tell us type of condenser
M unable to read this language, question is not clear please write totally in English.
@@PowerPlantDiscussion tell about condenser types?
Kya effect padega entropy pay
Please Make video on regenrative surface condenser 🙏🙏
Very nice
why cooling water temperature difference is not greater than 10 deg, please explain
Sir maine pahile v aapse request kiya tha ki aap lp, hp, b&s, and reducer Pump ka work ball coal mill me kyon hota h.? Please solve this problem sir
Sure dear I'll make very soon
Sir thora regenerative surface condenser samjha dijiye
Sure dear
Amazing sir ❤️
Bhut sandar
Hi sir make screw compressor video ..
Sure dear I'll make
Air cooled condenser ka video banavo sir
Why cold water enter from bottom and exit from top...why not reverse direction
If we provide at top side then heat transfer rate is more in top side, so cooling water gain heat and become as higher as steam temperature so half bottom if these hot cooling water circulated the heat transfer rate is negligible, so to proper heat transfer in Condenser, firstly water provide from bottom side some amount of heat absorbed after that top half remaining absorbed.
Good afternoon sir... Please make video working on throttle valve and governor...
Sure dear very soon I'll upload video on this topic
Pls sir vacuum cooling line up information
The main Objective is to maintain the low (i.e below atm pr.) Then how it comes true the condenser is constant pressure latent heat extracting device.
Hello
Sir, surface condenser and condenser me difference kya h, plz detail me bataiye.
Condenser ek closed type of heat exchanger Device h jaha heat Ka exchange krte h, condenser may be classified according to their use like ACC where air is used for heat exchange & Surface Condenser where water is used for heat exchanging.
@@PowerPlantDiscussion thanks
@@PowerPlantDiscussion condenser type Detial btay plz
Turbine dcs ke bare Mai btaiye
how many passes in tube and shell of surface condenser install with turbine?
Is pr numerical kraye sir
Ha Mai iska numerical Kia hu jisko bahut jald upload kr dunga dear, jisme Calculation h no of tube, quantity of cooling water, and their efficiency.
Mdfp and tdfp pumps ki ek video jrur bnaoo
Sure bna dunga
Sir dummy karna matlab kya hai..plz explain ?? If possible with a picture of dummy
Us tube ko close kr dena
So2 and No2 volues mg/Nm3 to kg and tones conversation how with example
Dear larg q banaya jata h..
Chota hoga tho kya problem hoge
Steam Ka volume jyada hota h comparatively to water so slightly larger make
Sir, why we restrict the temperature difference upto 10°C of cooling water.
Because we only remove latent heat of exhaust steam in condenser, if exhaust steam having higher temperature (means loss of Turbine efficiency) then this delta temperature increases, so we design condenser only for removing such a latent heat means both steam and condensed water having same temperature only phase change after cooling in condenser. This 10°C is constant means if more heat available in steam which is not condensed in condenser so the accumulation of non condensing gas increases which drops the vacuum so we takes action on Operation. For Turbine best efficiency we have restricted this 10°C value.
Thanks
Sir why temp difference between inlet water of condenser and outlet water maintained 10 ℃
SIR make a vd on acc
Sure dear I'll make
Sir Could you explain about regenerative aph
Sure I'll make
Sir,please reply why exhaust hood temperature increases while rolling of turbine.Please sir explain with some details.Thanks sir.
The whole kinetic energy of steam is not utilised during turbine rolling, so due to accumulation of these energy gradually increase of temperature and if synchronisation done then proper utilisation of kinetic energy by turbine, so this temperature start decreasing, I'll make seperate video on this topic.
@@PowerPlantDiscussion Thanks sir.when is next vedio coming?
Sir, what bad effect will occur if hot well level rise or down.
Dear if hotwell level high it means the space in condenser is reduced for condensing the exhaust steam, so accumulation of non condensing gas increases it means vacuum drops, in second condition if hotwell level low it means shortage of water at suction of CEP Pump which is Reason of cavitation in pump, ultimately damage of pump so to avoide this type of happening always we maintain hotwell level.
Thanks
In between surface condenser and vapour condensate tank their is baromatric leg to maintain the vacuum inside the surface condenser so if it not maintained properly then vacuum breakdown will occur also vapour condensate pump will run dry. Also we have to maintain oxygen content of condensate because it will cause corrosion, for more information please refer HEI standard for steam surface condenser where they have mentioned 7ppb to 14 ppb oxygen content.
Water circulation kaise hota h sir cfbc boiler mei plz help me sir.....eco ,riser drum downcomer,evap downcomer, screen downcomer,....yeh sb mei kaha se water or kaise flow krta h plz help me sir
Please watch my video on CFBC Boiler this video helps you lots to understand this all point, for more details I'll make seperate video on this topic.
Nice
air cooling condenser video please. 🙏🙏
Sure I'll make
Plzz explain different types of cycle in TG area (like condensate,steam,feedwater)
Sure I'll make
Dear Sir please tell me why we maintain the hotwell level is 50 % and external cold water source of condenser during the process (for condensing purpose )
If hotwell level maintain high it means this water tends to occupy the area where steam condensation which causes drop in vacuum, if water 20% or below the amount of water at pump suction side reduces which is reason of cavitation, and external cooling system is required for condensing the exhaust steam.
What is Candensr safty sir
👏👏
Jay hind sir
Which material is used to make surface condenser's tube?
Cast iron
Jandar Sundar
Thanks a lot
Sir condenser and ejector plant me uper kyu rakha jata he
Uska aap video banaye
boiler hot lightup afbc
Condenser and ejector uper kyu rakha jata he
10 degree hi q maintain kr t h sir
Ye parameter volume of steam occupied in surface condenser and we rejecting only Latent heat so if we increase temperature it means Condenser volume is smaller in size so volume for exhaust steam is less to avoid this we maintain always temperature difference 10°C maximum.
Sir isco counter surface condenced bolte he ki nehi
Ye counter (means opposite) ni hota h balki cross flow bol skte h.
🎉