What are DC/AC Ratios, Overloading Ratios or Inverter Loading Ratios?
Most inverters let you oversize the array up to a point relative to the inverter AC output. We often call this overloading ratio or DC/AC ratio.
#solar #solarenergy #solarpower #stringsizing #solarpanel #inverter #solarmodules #battery #batteries #loadshedding #loads #diysolarsystem #diysolar #inverter #overloading #ratio
Просмотров: 89

Видео

Grid Support Functions: Inverter Ride-Throughs Examples
Просмотров 24Месяц назад
Checkout uptopsolarpower.com for more information! How do inverters response to grid disturbances and how doe it support the grid? In this video we'll explore inverter ride through example requirements and settings.
UpTop Solar Welcome
Просмотров 262 месяца назад
Welcome to UpTop Solar! I'd like to share some of my knowledge to you. If you have any questions feel free to ask and I'll try to answer them! uptopsolarpower.com #solar #solarenergy #solarpower #stringsizing #solarpanel #inverter #solarmodules #battery #batteries #loadshedding #loads #diysolarsystem #diysolar #inverter #overloading #rationjob Music I use: www.bensound.com License code: FDLJYU9...
Temperature Coefficient Converter Tool: mV/k or mV/C to %/C
Просмотров 393 месяца назад
On rare occasions you may need to convert your temperature coefficients from mV units into %. This is a quick tool you can you if you find yourself needing to do this for your string sizing tools or modeling tool. uptopsolarpower.com/mv-converter#page-top
Grid Support Functions: Inverter Protections & Ride-Throughs
Просмотров 463 месяца назад
Checkout uptopsolarpower.com for more information! How do inverters response to grid disturbances and how doe it support the grid? In this video we'll explore inverter ride through behaviors dictated by industry standards and utilities.
String Sizing a Fronius Inverter
Просмотров 894 месяца назад
uptopsolarpower.com/string-sizing#page-top Feel free to try it out yourself! Watch me go through a string sizing exercise for a Fronius Inverter!
String Sizing a Victron Solar Charger
Просмотров 835 месяцев назад
uptopsolarpower.com/string-sizing#page-top Feel free to try it out yourself! Watch me go through a string sizing exercise for a Victron Solar charger!
Overloading An Inverter (DC to AC Power Ratio): How does it work?
Просмотров 4636 месяцев назад
Most inverters let you oversize the array up to a point relative to the inverter AC output. We often call this overloading ratio or DC/AC ratio. I get questions like "how does that work?" and "how does that not damage the inverter?". This is how the inverter handles an oversized array (be sure not to exceed the inverters published limits). #solar #solarenergy #solarpower #stringsizing #solarpan...
String Sizing my SolArk Inverter
Просмотров 1418 месяцев назад
uptopsolarpower.com/string-sizing#page-top Feel free to try it out yourself! Watch me go through a string sizing exercise for my SolArk inverter!
How to Interpret I-V Curve Tracing Results #13: IV-Curve Evaluation Tool
Просмотров 2918 месяцев назад
Let's review one helpful article's flow chart and a tool based on it. Download the tool here: www.uptopsolarpower.com/iv-curve 1)hal.science/hal-03415367 2)www.solmetric.com/wp-content/uploads/2022/11/SolarPro-FieldApplicationsOf-I-V-Curve-Tracers-Hernday.pdf 3) www.solmetric.com/wp-content/uploads/2022/11/SolarPro-I-V-feature-article-Hernday.pdf 4) relab.uob.edu.bh/wp-content/uploads/2019/11/s...
How to Interpret I-V Curve Tracing Results #12: A Good Result and a Bad Result
Просмотров 1439 месяцев назад
How to Interpret I-V Curve Tracing Results #12: A Good Result and a Bad Result
How to Interpret I-V Curve Tracing Results #11: Fill Factor
Просмотров 1969 месяцев назад
How to Interpret I-V Curve Tracing Results #11: Fill Factor
How to Interpret I-V Curve Tracing Results #10:Low Current Ratio
Просмотров 1139 месяцев назад
How to Interpret I-V Curve Tracing Results #10:Low Current Ratio
How to Interpret I-V Curve Tracing Results #9: Low Voltage Ratio
Просмотров 1359 месяцев назад
How to Interpret I-V Curve Tracing Results #9: Low Voltage Ratio
How to Interpret I-V Curve Tracing Results #8: Rounder Knee
Просмотров 1309 месяцев назад
How to Interpret I-V Curve Tracing Results #8: Rounder Knee
How to Interpret I-V Curve Tracing Results #7: Lower Voc
Просмотров 1549 месяцев назад
How to Interpret I-V Curve Tracing Results #7: Lower Voc
How to Interpret I-V Curve Tracing Results #6:Lower Short Circuit Current (Isc)
Просмотров 1769 месяцев назад
How to Interpret I-V Curve Tracing Results #6:Lower Short Circuit Current (Isc)
How to Interpret I-V Curve Tracing Results #5: Step in I-V Curve
Просмотров 2249 месяцев назад
How to Interpret I-V Curve Tracing Results #5: Step in I-V Curve
How to Interpret I-V Curve Tracing Results #4: I-V Curve Possible Issues
Просмотров 2859 месяцев назад
How to Interpret I-V Curve Tracing Results #4: I-V Curve Possible Issues
How to Interpret I-V Curve Tracing Results #3: Overview Checklist and Tips When Testing
Просмотров 2869 месяцев назад
How to Interpret I-V Curve Tracing Results #3: Overview Checklist and Tips When Testing
How to Interpret I-V Curve Tracing Results #2: Introduction to I-V Curves
Просмотров 4249 месяцев назад
How to Interpret I-V Curve Tracing Results #2: Introduction to I-V Curves
How to Interpret I-V Curve Tracing Results #1: Intro to Module Topology
Просмотров 4739 месяцев назад
How to Interpret I-V Curve Tracing Results #1: Intro to Module Topology
UpTop Solar - PV System String Sizing Tool Quickstart
Просмотров 3562 года назад
UpTop Solar - PV System String Sizing Tool Quickstart
UpTop Introducción Solar 101 # 6: Elegir un Módulo
Просмотров 113 года назад
UpTop Introducción Solar 101 # 6: Elegir un Módulo
UpTop Introducción Solar 101 # 5: Elegir un inversor
Просмотров 163 года назад
UpTop Introducción Solar 101 # 5: Elegir un inversor
UpTop Introducción Solar 101 #4: Analisis de Carga
Просмотров 153 года назад
UpTop Introducción Solar 101 #4: Analisis de Carga
MATE3 DataLogging : How to Read Results!
Просмотров 4753 года назад
MATE3 DataLogging : How to Read Results!
UpTop Introducción Solar 101 # 3: Descripción General de la Industria
Просмотров 113 года назад
UpTop Introducción Solar 101 # 3: Descripción General de la Industria
UpTop Introducción Solar 101 Series # 1: Bienvenido
Просмотров 383 года назад
UpTop Introducción Solar 101 Series # 1: Bienvenido
Entonces, ¿Quieres Solar?
Просмотров 33 года назад
Entonces, ¿Quieres Solar?

Комментарии

  • @tanzeelakakitchen7959
    @tanzeelakakitchen7959 6 дней назад

    So beautiful video my dear friend 🥀🌷🌺🌻🌹🎋💐🌸🌼

  • @vibhakarpatel7200
    @vibhakarpatel7200 Месяц назад

    You are showing point on iv curve on 5 kw and speaking that it will try to reach 8 kw ! Explanation not proper at all and what you show on graph you speak totally differently and very fast too

    • @uptopsolar
      @uptopsolar Месяц назад

      You are confusing the I-V curve to the P-V curve. That's ok! Look carefully at the key and color code. The teal color and dot isn't representing power (current vs voltage relationship), only the yellow. The explanation is correct. Thanks for watching! :)

  • @prefectuscastrorum2339
    @prefectuscastrorum2339 3 месяца назад

    thanks for the informative information....Moreover, this would be a great course for new solar string owners... Thanks

    • @uptopsolar
      @uptopsolar 3 месяца назад

      Thank you for the kind comment. Glad it was helpful!

  • @jansmit4628
    @jansmit4628 3 месяца назад

    The max PV power of the string can be higher than specified for the DC input upto around 150%. The converter will "ignor" this extra available power and not convert it to the AC side. This will result on clipping the highest possible level, but this lost is only a few procents in regard to the total converted value. As a positive effect, the converter will convert power over a larger time span during a day, so produce more AC power. A second general mistake is that the each panel directly generated it's almost full voltage the moment some light shines on it, so the minimum MPPT voltage is directly exceeded. The string presents however a very low current at this low light level. The output current will be linear with the amount of light shining on the string. The converted will decide how much DC power is converted to AC power.

  • @pnela4648
    @pnela4648 3 месяца назад

    But if we multiply 13.84*49.42, it’s equal to 684.46 How is that at 540?

    • @uptopsolar
      @uptopsolar 3 месяца назад

      13.84 Isc is at 0V (short circuit) = 0 W and 49.42 Voc is at 0 Amps ( Open circuit) = 0W . You see this represented at each end of the power curve. You multiply the Vmp x Imp to get power.

  • @darrellfort1668
    @darrellfort1668 3 месяца назад

    how does removing the diodes on a solar panel help at all? does anyone know

    • @zenniz1992
      @zenniz1992 Месяц назад

      Bypass diodes take up space, but it is not recommended to have zero bypass diode.

    • @darrellfort1668
      @darrellfort1668 Месяц назад

      @@zenniz1992 thanks

  • @redhammer9273
    @redhammer9273 4 месяца назад

    thx u for your time and effort what software do u use to plot the IV curve ?

  • @jamesdean7756
    @jamesdean7756 4 месяца назад

    Makes no sense to me

  • @RehanMazhary
    @RehanMazhary 4 месяца назад

    Awesome tool!!! thank you for sharing.. I just downloaded and was taking it out for a test drive. One question though... Why does cell D19 show "TRUE" instead of the value that you input there? I tried to see the logic/ formula but it only lets me input a value and then displays TRUE regardless of whatever value I input for the Test Voc value. Also I am unable to edit the Pmp value for my panels... Please help

    • @uptopsolar
      @uptopsolar 4 месяца назад

      Hmm, that's strange. I see that too. I'll look into it now and let you know when I've updated it, hopefully tonight.

    • @uptopsolar
      @uptopsolar 4 месяца назад

      Check it out now and let me know if there is anything else. It should say Version 3.

  • @MrSummitville
    @MrSummitville 5 месяцев назад

    When using your APP on a cell phone in Portrait Mode, the parameters for the Victron 250/60 Charge Controller get truncated and "appear" very wrong. Landscape mode is OK.

    • @uptopsolar
      @uptopsolar 4 месяца назад

      Hi thanks for the feedback, I can try to make more portrait mode friendly in the next version.

  • @MrSummitville
    @MrSummitville 5 месяцев назад

    Victron RS 450/100 and RS 450/200 Charge Controllers *NOT* listed?

    • @uptopsolar
      @uptopsolar 4 месяца назад

      No one has suggested it to be added. I can certainly add it. For now, feel free to enter the specs in the "Custom" mode for inverters or Solar Chargers that are not listed. I'll add it in the next update. Thanks!

  • @venishkumar4658
    @venishkumar4658 7 месяцев назад

    Pls share about PV module string testing

  • @irfanzahid1506
    @irfanzahid1506 9 месяцев назад

    Could you explain....why max fault current contribution is greater in low capacity of solar inverter compare to high rating solar inverter.

    • @uptopsolar
      @uptopsolar 9 месяцев назад

      Hi! Can you clarify your question? Are you implying and asking why do lower capacity inverters (smaller inverters like residential) have higher fault current contribution than larger inverters (utility scale)? If so can you share two models as examples so that I better understand the question and see the type of inverter and fault current ratings on both models?

    • @irfanzahid1506
      @irfanzahid1506 9 месяцев назад

      @@uptopsolar yes my question is, why low capacity of inverter has max fault current contribution (1 cycle RMS) is more than high capacity of inverter of max fault current contribution (1 cycle RMS) . For example:- a. Cps inverter model name CPS SCA 36ktl-DO/US- 480 has fault current contribution (1 cycle RMS) is 73.2A (1.68 PU), while b. Cps inverter model name CPS SCA 60 ktl-DO/US-480 has maximum fault current contribution (1 cycle RMS) 64.1 A (1.6/0.88 PU).

  • @keyable
    @keyable Год назад

    Whats the difference between Rated MPPT Voltage range and MPPT Operating Voltage range?

    • @uptopsolar
      @uptopsolar 9 месяцев назад

      I couldn't find the SMA manual that shows this, but from my experience with other inverters... MPPT Operating Voltage Range is where the inverter can operate and perform some MPPT, it's a wider range. Then Rated MPP Voltage range is the range where the inverter can out put it's max power. So in this example it appears that between 100Vdc and 155Vdc there could be some derating, same thing on the high end (between 480Vdc and 550Vdc). Between 155Vdc and 480Vdc, you could expect full power output.

    • @keyable
      @keyable 9 месяцев назад

      @@uptopsolar Thanks for the information!

    • @jansmit4628
      @jansmit4628 3 месяца назад

      No, the voltage is immediately there the moment some light hits the string. The string generates however hardly any current as only a view number of atoms are hit by the light. Current generation will linear increase with the increase of light on the panel upto a maximum where the maximum output is reached. See an episode of Gerry does Solar.

  • @noenuguit440
    @noenuguit440 Год назад

    You're good easy to understand or follow. Thanks

    • @uptopsolar
      @uptopsolar 9 месяцев назад

      Thanks, I appreciate the kind words!

  • @rustypope8643
    @rustypope8643 3 года назад

    Very nice vid! You need more subs! Take a look at PromoSM, I used it on my main channel and it helped me rank my videos!