BLT Jimmy
BLT Jimmy
  • Видео 5
  • Просмотров 15 337
Biolight DM Module - Drip Monitor
Biolight provides unique Drip Monitor module for patient monitors.
➤ Make the intravenous infusion safer.
➤ The unique patient monitor with drip monitoring function, which can monitor the drip rate and clamp the infusion tube to stop infusion.
➤ It helps the healthcare workers to set the drip rate and gives a safer infusion to the patient.
Просмотров: 754

Видео

Biolight E30 - 12 leads ECG user instruction
Просмотров 5 тыс.2 года назад
Biolight E30 - 12 leads ECG This video is provided as user instruction for Biolight E30 12 leads ECG machine. (From Product department: Jimmy) Features: 4.3′′color LCD touch screen high-resolution & high- frequency data sampling realize that waveforms display accurately Innovative digital filters ensure better performance high-precision data saving ensures the accuracy of follow-up data analysi...
BIOVISION - Biolight Brand-new CMS (Central monitoring system)
Просмотров 6 тыс.3 года назад
BIOLIGHT BioVision is the revolution of the Central Monitoring System. It is intended to conduct centralized monitoring of vital sign information from patient monitors manufactured by Biolight, through wir-ed or wireless LAN in hospital or medical institutions. ■ Support nursing group, patient group; ■ Waveform freezing; ■ Large capacity storage ■ Bed switching; ■ HL7 standard. ■ Support up to ...
Biolight F90 Fetal monitor
Просмотров 1,3 тыс.3 года назад
This video is a demonstration of Biolight F90 Fetal and Maternal monitor.
Biolight S12 Patient monitor + CMS
Просмотров 2,3 тыс.3 года назад
This video demonstrates Biolight S12 Patient monitor connect with central monitoring system - M6000C touchscreen display.

Комментарии

  • @warunakumara7671
    @warunakumara7671 6 месяцев назад

    SIR WHAT DOES THE TWO BUTTONS DO IN THE DRIP MONITOR

  • @warunakumara7671
    @warunakumara7671 6 месяцев назад

    SIR S12 MONITOR DETECT GCS AUTOMATICALLY , TEACH US HOW TO USE THE NEWS AND MEWS IN IT , DOES THE MONITOR AUTO MATICALLY DETECT NEWS AND MEWS ALSO

  • @MedicalMaintenance
    @MedicalMaintenance 9 месяцев назад

    my ECG print but blank

  • @kuenzangthukten6911
    @kuenzangthukten6911 Год назад

    We need this tech. How can we work together ?

  • @thirrell
    @thirrell Год назад

    What the default password?

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY Год назад

      Drop me a email, I'll send you the password. Thirrell😃 jimmy@blt.com.cn

  • @YILDIRIMAILESI
    @YILDIRIMAILESI Год назад

    Demo number?

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY Год назад

      Email to me for demo password, thanks! jimmy@blt.com.cn

  • @natnichasritan1464
    @natnichasritan1464 Год назад

    Can show in mobile view?

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY Год назад

      Yes. With BLT remote viewing server, real time data can be shown on mobile devices.

  • @wiwikwiwik6009
    @wiwikwiwik6009 Год назад

    1.35 Lego Super Mario sleeping 🥺

  • @farhodkuziev617
    @farhodkuziev617 2 года назад

    What about this?

  • @farhodkuziev617
    @farhodkuziev617 2 года назад

    Hi! Thank you for video! In our patient monitor ECG not working, asked password

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY 2 года назад

      Changing of critical parameters settings, Please key in 12 34 56 for confirming the operation.

  • @btech9404
    @btech9404 2 года назад

    can you have a video on how to connect the patient monitor (s12) to the cms via network (Lan or Wlan)?

  • @btech9404
    @btech9404 2 года назад

    do you have a video on how to connect device on the CMS?

    • @rojbonoy674
      @rojbonoy674 2 года назад

      ruclips.net/video/BnhFBiCIl30/видео.html

    • @btech9404
      @btech9404 2 года назад

      @@rojbonoy674 thank you...

  • @semirsultan9670
    @semirsultan9670 2 года назад

    can we use it with ctg, biolight F90

  • @Iamfick
    @Iamfick 2 года назад

    Can E30 ECG CONNECT TO ANY EXTERNAL PRINTER USE USB CABLE?

  • @teddyasrat7437
    @teddyasrat7437 2 года назад

    We do how BLT AnyView A8. where can we get the CMS software and help?

  • @vschannel7760
    @vschannel7760 2 года назад

    Very Nice

  • @hobocop99
    @hobocop99 2 года назад

    What's the password for entering entretien

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY 2 года назад

      Sent me an email, Hu Sain. - jimmy@blt.com.cn

  • @moment5196
    @moment5196 2 года назад

    How can I get one

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY 2 года назад

      Hi. You may contact us by email. - jimmy@blt.com.cn

  • @warunakumara7671
    @warunakumara7671 3 года назад

    sir in E30 ecg there are some settings that i got to ask from you , what does manual 1 , manual 2 , manual 3 do , in the unit , what does AC filter, DFT filter, EMG filter, Low pass filter do and how to select those filter values to each persons seperately ( i mean about what we have to think when we have to change those filters) , whats lead name AAMI and IEC , what does pre sample , real time sample , trigger sample do in sampling mode , if the language of unit change to chinese how to change it , whats the maintennace password of unit also sir some time interference come when using this unit near electrical bed this doesnt happen in Mindray and philips ....etc they also doesnt have equipotential ground line .

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY 3 года назад

      1. In manual mode, real-time recording of ECG waveform is conducted manually according to the requirements of users, and start and stop of recording are controlled via keys. Optional: Manual 1(display waveform of leadI~III), Manual 2(display waveform of lead aVR~aVF), Manual 3(display waveform of lead V1~V3), Manual 4(display waveform of lead V4~V6). 2. ➤ AC filter: Resist interference of AC power to prevent attenuation or distortion of ECG signal. ➤ DFT filter: Resist drift of baseline to ensure that ECG signal is on baseline at the time of recording. ➤ EMG filter: Resist interference to ECG signal caused by strong muscle fibrillation. When EMG filter is in use, lowpass is【Off】. ➤ Lowpass filter: Restrict the bandwidth of input signal and attenuate the signals higher than the cut-off frequency. When lowpass is in use, EMG filter is【Off】. 3. The IEC standards were published as international standards and the AAMI standards were published as standards in the United States. 4. ➤ When “Pre-sample” is selected, collection of ECG data begins as soon as lead is connected to patient; ➤ When “Real-time sample” is selected, if the user press Record button, record of the ECG data collected within 10s after pressing this key will be exported; ➤ When “Trigger sample” is selected, if the user press Record button, device will automatically trigger record once in case of arrhythmia. 5. Choose added language: Press 【System】 in main interface to enter system setup interface. Choose un-added language: Press 【System】, Select【Maintenance】, key in maintenance password, select 【Language】to add languages. 6. 【Maintenance】password, please contact me (Jimmy) by email: jimmy@blt.com.cn 7. Biolight E30 has standard Equipotent grounding terminal to allow device connect to the Equipotential grounding system of hospital. When there's interference from high frequency devices, we can set the filter parameters in order to improve the ECG anti-disturbance performance. Hope this clears your doubts! Thank you. Jimmy (Clinical Product specialist) Email: jimmy@blt.com.cn Biolight Product Department

  • @warunakumara7671
    @warunakumara7671 3 года назад

    thank you for the explanation sir , sir i got one more question to ask from you in M8000 monitors spo2 setup what does c lock switch do , whats the different between signal strength display and low confidence display

  • @warunakumara7671
    @warunakumara7671 3 года назад

    why does finger tip pulse oximeters give readings to pen or pencil

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY 3 года назад

      The patient’s condition is detected based on the sensitivity of the amount of red and infrared light falling on the sensor of the pulse oximeter or probe in other machines. When this is obstructed by increasing the distance between the LED and the detector, or by inserting some object inside the probe, the module will think the finger is inserted and will start searching for a pulse. In this condition, the varying intensity of diffused light falling on the detector can cause a pulsating effect and lead to a reading on the pulse oximeter. The pulse oximeter is a very sensitive device. However, if the gap between the LED and the sensor is closed fully, so that no light falls on the detector, the pulse oximeter will sense no pulse and there won’t be any reading. Small beams of light pass through the blood in the finger, measuring the amount of oxygen. It does this by measuring changes in light absorption in oxygenated or deoxygenated blood. The pulse oximeter will thus be able to tell you your oxygen saturation levels. The same is observed in all other devices. Hope this answers.

  • @warunakumara7671
    @warunakumara7671 3 года назад

    sir i got to ask several questions about biolight M12 monitor from you . in its ecg setup theres a setting called multi lead signal what does it do ? if we switch it on , also in the nibp setup sequence mode what does phase A, B , C,D DO When we switch them on , in its main menu theres a setting called full disclosusre what does it do , in the same menu whats CAA , EWS , GCS whats the importancy of those parameters ,in ews setup whats score and auto score , Also show us how to divide screen to see 16 nos of beds at the same time in m6000c cms software , in m8000 monitors spo2 setup what does c lock switch do , whats the different between signal strength display and low confidence display , in the same spo2 setup what does average time do if you can sir please explain each function of cms 6000 and M8000 , M12 MONITORS THANK YOU

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY 3 года назад

      Hi. Waruna. Thank for asking. 1. When multi-lead analysis function is switched on, the【ECG 2】will participate in the calculation of HR together with 【ECG 1】 to provide more accurate HR reading. 2. NIBP sequence measurements can consist of up to 5 measurement periods: A, B, C, D, and E. You can set the measurement duration for each period and the interval between NIBP measurements in each period separately. It mainly assist the user with a more customizable measurement to meet clinical needs. 3. On the Full Disclosure review page, you can review waveform data up to 72 hours. You can view compressed waveforms, full waveforms and numeric values. 4. Clinical Assistive Applications (CAA) is the comprehensive analysis and centralized presentation of the existing measurement results of the monitor, and it is the electronic application of common clinical guidelines and tools. The main purpose of clinical assistive applications is to improve the working efficiency of doctors. It is not used for diagnosis and cannot replace medical staff to make decisions. 5. Early Warning Score (EWS) The Early Warning Score can help identify early signs of deterioration in patients and is an early warning indicator for critical or potentially critical illness. The Early Warning Score System obtains corresponding scores by monitoring and observing patients' vital signs and states, and gives corresponding suggestions on solutions according to the scoring results. It's a scoring system that score each parameter selected and then calculate an aggregate score. The grading of each parameter is color-coded to indicate the corresponding critical level. Provide action when the total score exceeds the range. 6. The Glasgow Coma Scale (GCS) is based on the content of the Glasgow Coma Index, It can be used for coma patients caused by various causes to objectively express the state of consciousness of patients. The GCS score includes three aspects: eye opening, verbal response and motor response. Usually it's used for patients who are confused, altered mental status, or having brain injuries, etc.

    • @BIOLIGHT-JIMMY
      @BIOLIGHT-JIMMY 3 года назад

      7. The signal strength prompt is used to indicate if the SpO2 signal strength measured is adequacy. 8. Average Time Select the average time for SpO2. The shorter the averaging time is, the quicker the monitor responds to the change in the patient’s oxygen saturation level. (It is invalid while use Nellcor SpO2 module).

  • @lizaluna1423
    @lizaluna1423 3 года назад

    Very informative and detailed video which is helpful to the users. Nice job Jimmy and thank you...