Friction Weld testing in Engine ValvesFriction Weld testing in Engine Valves
Friction Weld testing in Engine Valves
Просмотров 4002 года назад
Thru Coat Thickness Measurement with Olympus 45MG EquipmentThru Coat Thickness Measurement with Olympus 45MG Equipment
Thru Coat Thickness Measurement with Olympus 45MG Equipment
Просмотров 10 тыс.3 года назад
The 45MG is an advanced ultrasonic thickness gauge packed with standard measurement features and software options. This unique instrument is compatible with the complete range of Olympus dual element and single element thickness gauge transducers, making this innovative instrument an all-in-one solution for virtually every thickness gauge application. Overview & Calibration of 45MG ruclips.net/...
Multilayer Thickness Measurement with Olympus 38 DL PlusMultilayer Thickness Measurement with Olympus 38 DL Plus
Multilayer Thickness Measurement with Olympus 38 DL Plus
Просмотров 7 тыс.4 года назад
Overview & User Interface of EPOCH-650Overview & User Interface of EPOCH-650
Overview & User Interface of EPOCH-650
Просмотров 2,4 тыс.4 года назад
Overview & Calibration of Olympus 45MGOverview & Calibration of Olympus 45MG
Overview & Calibration of Olympus 45MG
Просмотров 20 тыс.4 года назад
Tube Thickness Measurement with Olympus 45MGTube Thickness Measurement with Olympus 45MG
Tube Thickness Measurement with Olympus 45MG
Просмотров 17 тыс.4 года назад
EPOCH-6LT Angle probe calibrationEPOCH-6LT Angle probe calibration
EPOCH-6LT Angle probe calibration
Просмотров 2,5 тыс.4 года назад

Комментарии

  • @allinontalentsrakesh4470
    @allinontalentsrakesh4470 18 дней назад

    Thanks sir

  • @naryatraditional7648
    @naryatraditional7648 23 дня назад

    How to activate Save and File option ? Currently showing "Option is not activated".

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 20 дней назад

      You need to purchase the datalogger activation key

  • @Shivamsingh-wp5eh
    @Shivamsingh-wp5eh 4 месяца назад

    Thank you sir

  • @RRRMusic303
    @RRRMusic303 7 месяцев назад

    Very useful information thank you

  • @SoularRebelation
    @SoularRebelation 11 месяцев назад

    ty

  • @akhils1670
    @akhils1670 Год назад

    Great information 👍, i need the videos shear wave inspection angle probe on drill pipe

  • @maheshkharat2861
    @maheshkharat2861 Год назад

    we are having same machine in our lab. we tried to set 'mm' as a permanent unit. please guide us. we tried as per manual: FILE SETUP - UNIT TYPE - MILIMETER - MEAS

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj Год назад

      Once u set what issue ocurrs. It will again change to inches?

  • @AshishKumar-yo6tb
    @AshishKumar-yo6tb Год назад

    Why velocity is changing while doing calbiration

  • @gangeshtripathi5233
    @gangeshtripathi5233 Год назад

    Sir which institute you are working for?

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj Год назад

      I am working with Blue Star Engineering Electronics limited

  • @AshishKumar-yo6tb
    @AshishKumar-yo6tb Год назад

    I am not getting stable reading and as well get 0.15 different

  • @MoazzamAli-fh9ci
    @MoazzamAli-fh9ci Год назад

    AOA sir plz give me your WhatsApp number

  • @sunilgavade2293
    @sunilgavade2293 Год назад

    Olympus EPOCH 650 Ultrasonic Flaw Detector Navigation Pad is good or Knob Configuration which is good for site work and Training

  • @sunilgavade2293
    @sunilgavade2293 Год назад

    Olympus EPOCH 650 Ultrasonic Flaw Detector Navigation Pad or Round Knob Configuration which is good for site work and Training

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj Год назад

      . Its depends on your usage.I personally recommend for knob version because its response is faster

  • @gundakishor
    @gundakishor Год назад

    I have 45 mg but after zero calibration it does not ask for through coat option sir, what will I do

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj Год назад

      Check whether EETC software activated in your 45MG. Call me for the procedure for checking

  • @ROVILYNBUGNA
    @ROVILYNBUGNA 2 года назад

    what other probes detect coating thickness ?

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 2 года назад

      D7908 & D7906 probe can measure theu coat thickness

  • @ROVILYNBUGNA
    @ROVILYNBUGNA 2 года назад

    does d-798 probe detect coating thickness as well just like d7906-sm?

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 2 года назад

      No, D798 is normal probe range in steel 0.61 mm to 100 mm however D7906-SM probe is thru coat probe range in steel 1 mm to 50 mm

  • @anujgupta7805
    @anujgupta7805 2 года назад

    How to master reset of this machine

  • @anujgupta7805
    @anujgupta7805 2 года назад

    Sir i have problem with my Olympus 45, problem is when i on machine then it show 0.1g on screen

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 2 года назад

      Please send me the photograhs on my no. 9599700373

  • @anujgupta7805
    @anujgupta7805 2 года назад

    Sir can you give your contact details

  • @qumartanweer6589
    @qumartanweer6589 2 года назад

    Very helpful video

  • @tunuprasad7318
    @tunuprasad7318 2 года назад

    Sir Aaysomatri ke vidoes

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 2 года назад

      ??

    • @FAM533
      @FAM533 Год назад

      Mai bhi Aaysomatri Drowning ka video dekhne aya tha but nahi mila😢

  • @mooneyvayarus9079
    @mooneyvayarus9079 2 года назад

    Chu slowly tell

  • @pratikpaul4753
    @pratikpaul4753 2 года назад

    Hello sir Can you please tell me the price? And how can I purchase this machine in Bangladesh.

  • @ahmedawan3960
    @ahmedawan3960 2 года назад

    can we perform UTM through coat using high temperature probes with this equipment ?

  • @gangeshtripathi5233
    @gangeshtripathi5233 2 года назад

    Why last two is rejected as monitor is showing same pulse and reading.

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 2 года назад

      We are checking friction weld strength in this setup, rejected samples are showing less than 80% amplitude hence rejected

  • @sunilbhatambare3810
    @sunilbhatambare3810 2 года назад

    Hey I am using modosonic edition 1 wall thickness gauge. To using alluminium alloy. Casting I am facing problem to checked wall thickness above 20mm wall in cylindrical surface can u suggest prob either wall thickness gauge

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 2 года назад

      Please buy olympus thickness gauges for better results

    • @sunilbhatambare3810
      @sunilbhatambare3810 2 года назад

      @@VijayKumar-qx2lj yes sir i agree with you but olympus gauge show few reading but all reading can't show. I used olympus gauge for trial purpose can you give me the number our olympus techiation.

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 2 года назад

      @@sunilbhatambare3810 could you provide me model of olympus gauge? You can contact me 9599700373

  • @sanjayrajeshirke7770
    @sanjayrajeshirke7770 3 года назад

    Very nice.information. Give to DAC

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 3 года назад

      Will upload a new video regarding the DAC & DGS

  • @gangeshtripathi5233
    @gangeshtripathi5233 3 года назад

    Sir I want to talk with you. Please tell me how to contact

  • @willamegomes4064
    @willamegomes4064 3 года назад

    Gostaria muito de aprender a calibrar o aparelho, teria algum material didático?

  • @rahularulraj1689
    @rahularulraj1689 3 года назад

    Thanks sir

  • @adrianhartanto54
    @adrianhartanto54 3 года назад

    Where can I buy it ?

  • @AbhishekSingh-yf9yd
    @AbhishekSingh-yf9yd 3 года назад

    Can we check Both Thickness and scaling of Boiler Tubes.. with this one..

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 3 года назад

      Yes with this equipment but we need separate probes for the smae

  • @aneesmohemmed4313
    @aneesmohemmed4313 3 года назад

    Sir Can you please tell me how much this equipment will couse

  • @pmkcenterprise9813
    @pmkcenterprise9813 3 года назад

    Pls, tell probe's name or number along with its measuring range!

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 3 года назад

      Model D798 tip dia 7.2 mm , 7.5 Mhz, range 0.6 mm to 100 mm

  • @gopichmech
    @gopichmech 3 года назад

    where can we get those coating shims..... or can we set the coating thickness directly

    • @VijayKumar-qx2lj
      @VijayKumar-qx2lj 3 года назад

      We can supply the same or you can also enter the epoxy paint velocity directly

  • @virenderswami6184
    @virenderswami6184 4 года назад

    Quotation required for Ultrasonic Thickness meter Make - Olympus Model - 45MG