Installing a Supco 3 n 1 compressor starter - what to do with extra power line?
My Kenmore fridge had 3 power lines running to the side of the compressor. The Supco hard start kit only tells you what to do with 2. The 3rd power cable in my situation was coming from my thermostat and running to the overload. My solution was to splice this 3rd cable into the "common" line of the Supco 3 n 1 kit.
Просмотров: 64 476

Видео

Malik Jury run 4:29:16
Просмотров 118 лет назад
Malik Jury run 4:29:16
Dmitri jury run 4:29:16
Просмотров 118 лет назад
Dmitri jury run 4:29:16
Bobby jury run 4:29:16
Просмотров 118 лет назад
Bobby jury run 4:29:16
Wright College Jazz Ensemble rehearsal
Просмотров 228 лет назад
All the Things You Are
Wright College Jazz Ensemble rehearsal
Просмотров 418 лет назад
St. Thomas
Wright College Jazz Ensemble rehearsal
Просмотров 518 лет назад
Poinciana
Wright College Jazz Ensemble Spring 2016
Просмотров 108 лет назад
All The Things You Are
Wright College Jazz Ensemble Spring 2016
Просмотров 108 лет назад
St. Thomas
Wright College Jazz Ensemble Spring 2016
Просмотров 178 лет назад
Watermelon Man
Wright College Spring 2016
Просмотров 128 лет назад
Poinciana
Wright College Jazz Ensemble rehearsal
Просмотров 438 лет назад
"Little Sunflower"
Wright College JE rehearsal 2015 My Foolish Heart
Просмотров 309 лет назад
Wright College JE rehearsal 2015 My Foolish Heart
Wright College JE Mahjong rehearsal 2015
Просмотров 339 лет назад
Wright College JE Mahjong rehearsal 2015
Milestones - 12/1/14 Wright College rehearsal
Просмотров 119 лет назад
Milestones - 12/1/14 Wright College rehearsal
A train - 12/1/14 Wright College rehearsal
Просмотров 239 лет назад
A train - 12/1/14 Wright College rehearsal
Mr. PC
Просмотров 1110 лет назад
Mr. PC
Blue Train
Просмотров 1710 лет назад
Blue Train
Corcovado
Просмотров 1910 лет назад
Corcovado
Blue Train
Просмотров 3010 лет назад
Blue Train
Mr. PC
Просмотров 3710 лет назад
Mr. PC
Corcovado
Просмотров 6610 лет назад
Corcovado
Blue Train
Просмотров 1010 лет назад
Blue Train
Mr. PC
Просмотров 1210 лет назад
Mr. PC
Wright College Jazz Ensemble 2013: more Oleo practice
Просмотров 4610 лет назад
Wright College Jazz Ensemble 2013: more Oleo practice
Wright College Jazz Ensemble 2013: Watermelon Man practice
Просмотров 4310 лет назад
Wright College Jazz Ensemble 2013: Watermelon Man practice
Wright College Jazz Ensemble 2013: Summertime practice
Просмотров 3010 лет назад
Wright College Jazz Ensemble 2013: Summertime practice
Wright College Jazz Ensemble 2013: Watermelon Man practice
Просмотров 10910 лет назад
Wright College Jazz Ensemble 2013: Watermelon Man practice
Wright College Jazz Ensemble 2013: Summertime practice
Просмотров 13610 лет назад
Wright College Jazz Ensemble 2013: Summertime practice
Wright College Jazz Ensemble 2013: Oleo practice
Просмотров 7810 лет назад
Wright College Jazz Ensemble 2013: Oleo practice

Комментарии

  • @JoyceSmith-u6c
    @JoyceSmith-u6c 27 дней назад

    Alexanne Land

  • @WoodFrancis-h3b
    @WoodFrancis-h3b 28 дней назад

    Adams Center

  • @MarianSpring-m2c
    @MarianSpring-m2c 28 дней назад

    Corbin Ville

  • @LambYetta-e8i
    @LambYetta-e8i 28 дней назад

    Mills Loaf

  • @JeromeBrady-z9i
    @JeromeBrady-z9i 29 дней назад

    German Land

  • @PearsonLeo-o2r
    @PearsonLeo-o2r Месяц назад

    388 Samson Trail

  • @shelltothekindgemini8819
    @shelltothekindgemini8819 2 месяца назад

    Mines comes one, then cut off, what’s the problem?

  • @gregnyssen1989
    @gregnyssen1989 3 месяца назад

    I have this exact setup and relay went bad and can definitively say that, contrary to some commenters about the three prong rotation theory, the bottom is common, left is start, right is run. BUT! Unlike tis video the extra "thermostat" wire tripped my breaker when splicing to the common, and the fridge and all its functions only worked with that extra wire connected to one of the power wires. Hope this helps anyone that was flummoxed like i

  • @donnya205
    @donnya205 3 месяца назад

    What about the Red wire on the new starter I know 1 hooks up on the right side . on the compressor i have a run capacitor , the top wire goes to the white, but the bottom wire goes to the thermostat .Do i splice the red to that? I would end up with 4 wires spliced together for the red wire on new starter?

  • @Henok-ib5yw
    @Henok-ib5yw 4 месяца назад

    Where should I connect the two wires (red and white) coming from the fan? I connected everything else but compressor is not on

  • @gsftom
    @gsftom 4 месяца назад

    Bro - thank you, thank you, thank you 🙂. I had the 3rd power wire as well and my compressor fired up as soon as I spliced it into the common wire like u described.

  • @justintran3265
    @justintran3265 5 месяцев назад

    CSR is how to remember it. And then reading from left to right and down just like reading a book. In your configuration which is an upside down triangle. Common is upper left then reading across would be Start and the middle pin which is down the middle and down would be Run. This is based on my commercial refrigeration training.

  • @joeshmoe1e
    @joeshmoe1e 5 месяцев назад

    Hi Everyone, thank you for the advice and input in these comments. I would like to say that I am not a repairperson and attempted this during the pandemic when I had no work - according to some comments, I did this completely wrong/backwards/dangerously. You may be right, I have no idea as I am not a repairperson! However I would like to share that it is May 2024 and my refrigerator is still running great off of this repair, sooo...🤷. Anyways, best of luck to you all and remember I have no expertise in this, just trying to get by and it seems to still be working. Perhaps next week my fridge will explode...😁

  • @Joe-ij3mg
    @Joe-ij3mg 5 месяцев назад

    Thank you so much. I searched all over google and now help. You r a life saver.

  • @sepehrfadaei7564
    @sepehrfadaei7564 6 месяцев назад

    Please note that there are a few major mistakes and issues in this way of wiring. 1) Your run and start wires (left and right on the compressor) are reversed. (If common is on top, Run is the right pin, if common is on the bottom, Run is the left pin.) 2) The black line connected originally to your bottom pin is one of your power lines (Hot). Your blue wire is your 2nd power line (Neutral), which was connected to the Run winding. The reason you have an extra wire is that you have a run capacitor. Your blue power line is also connected to one side of the capacitor, and from the other side you get the pink wire, which needs to directly connect to the compressor’s start pin. 3) Your run capacitor, which was supposed to be in series with your start winding, is now instead connected in parallel to your Hot and Neutral! So, you need to use the fridge black and blue wires and connect those to the 3n1 black power lines. And you should splice the pink wire to your 3n1 white wire to connect it to your start pin on your compressor. (and don’t forget your reversed Run and Start pins) I will be surprised if you haven’t damaged your run capacitor and compressor. Please either remove this video, or make another one with the right wiring to not misguide others. I appreciate your bravery and trying things out! You can refer to this video to fully understand it: ruclips.net/video/zqhkvXPjtKc/видео.html

  • @delmamilagrosmorenocortez747
    @delmamilagrosmorenocortez747 6 месяцев назад

    Por dentro del arrancador como van conectados

  • @demonology1013
    @demonology1013 7 месяцев назад

    Great video. My setup is I have 2 wires that connect to starter relay from the capacitor. I have one black one that connects and one yellow. I just ordered this kit. Which wires do I plug in the 2 black wires that's attached to the supko kit?

  • @strung00out
    @strung00out 8 месяцев назад

    Thank you. I have had issues with mine. Finally bought this and noticed everyone only had 2 wires. Saw this, did what you said it started right up! Thank you

    • @codyphillips3406
      @codyphillips3406 8 месяцев назад

      Did yours work? I did so and it didn’t work but I have the white wire closest to me as that’s how it was before I bought the 3 n 1… i heard a clicking before I installed this now I don’t hear anything.

  • @kamy4531
    @kamy4531 8 месяцев назад

    I think the red wire (Run) should switch to the white wire (Start) because the compressor connectors are upside down

    • @codyphillips3406
      @codyphillips3406 8 месяцев назад

      Did you figure it out? I’m confused with this… I put white closest to us (that’s how It was before I installed the 3n1) but now the compressor won’t even click…. Before it was at least clicking and warm..

    • @kamy4531
      @kamy4531 8 месяцев назад

      I checked online and RUclips if common pin from top switch down then red wire or run wire should connect from right pin to left pin

    • @codyphillips3406
      @codyphillips3406 8 месяцев назад

      @@kamy4531 my common is on bottom. I currently have the white wire closest to me. Is that wrong? Compressor not turning on…

    • @codyphillips3406
      @codyphillips3406 8 месяцев назад

      @@kamy4531 before I tried this white was closest to me and that’s how I installed the 3n1 but now it won’t even click on. Wondering if I try how video is if it’ll make a difference

  • @aurelianida4805
    @aurelianida4805 9 месяцев назад

    După pornirea compresorului cum procedăm? Rebranșăm la loc compresorul la starterul frigiderului?.

  • @blackjebus1000
    @blackjebus1000 10 месяцев назад

    Thank you very much! Super awesome info.... Much appreciated. 👍 Success!!

  • @mikemcewen1360
    @mikemcewen1360 10 месяцев назад

    legend. thanks for this!

  • @therobs1484
    @therobs1484 11 месяцев назад

    You wired the 3 to the compressor wrong flip the diagram upside down should be red black white from left to right

  • @frenchyroy1260
    @frenchyroy1260 Год назад

    My issue is where is the power cables. Or source. This is what I have and wondering if we can just connect the 2 Blk wires to the orange and or white

  • @frenchyroy1260
    @frenchyroy1260 Год назад

    Thank you for the comments.

  • @TajFrancis-l1z
    @TajFrancis-l1z Год назад

    I jus fix my fridge with the extra power line thanks for the video 🤗

  • @phil78720
    @phil78720 Год назад

    The problem I see with all these videos is what about the on/off/thermostat switch on the outside of your freezer. You know that dial that turns on or off your freezer and you can set it to mid/high/low etc. Anyway the solution was simple. In its original configuration, two wires from the power go to the switch/thermostat. Blue and brown. A third wire coming from the switch/thermostat (black) provided 120 when there is a call for cooling. So simply connect the Supco 1 power lead to that black wire. The blue wire connect to one incoming power. The brown wire will connect to both the Supco and other power wire. Now you can turn off/on your freezer and thermostat control it.

    • @MickeyKimsey
      @MickeyKimsey Год назад

      You win the internet today🎉 between this guys video and your solution, I have now solved the puzzle.

    • @bobbymartin6866
      @bobbymartin6866 11 месяцев назад

      I edited this to say that I was wrong. 😂

    • @ChristopherUrbane
      @ChristopherUrbane 8 месяцев назад

      This is my issue but for some reason it keeps tripping the breaker. It worked for like twenty minutes.😢

  • @johndowns7536
    @johndowns7536 Год назад

    From a contractor: To have a hard start kit installed on your compressor, you can expect to pay anywhere from $300 to $350. Our prices always include the cost of labor and parts. The overall price of a hard start kit is cheaper than paying for a compressor replacement which can be $2,500 or even more. $20 part, 10 minutes work.

    • @tomdziekan2088
      @tomdziekan2088 Год назад

      How long does the repair last for usually? Is it a forever fix?

  • @treyfred3247
    @treyfred3247 Год назад

    Not to be rude, but adding a "power" to "common" makes no sense period. "Common" is Ground back to your electric provider. "Power" is electricity coming in from your electric provider. "Common" is the Path back to the Electricity grid.

    • @michaelcooprider4973
      @michaelcooprider4973 Год назад

      So I connected the two wires that give me 120 power to the black power wires. I also hooked up the start, run, and common wires to the compressor and it did not work. I left the third wire that with to the start relay disconnected and my system will not kick on. My compressor checks out with a multimeter but it will not kick on. Do I need to connect that Start Relay wire to the common as he showed in this video?

    • @michaelbaltzer562
      @michaelbaltzer562 11 месяцев назад

      100% spot on. the common to the compressor from the 2 + 1 is powered internally from the line side L2, L1 hits the start and run., DIY-ers just call a tech before you blow it up or get juiced. Nobody has mention Ohmning out the windings before you order parts from the web.

    • @codyphillips3406
      @codyphillips3406 8 месяцев назад

      I have the extra black wire (believe it’s thermostat) where would that go on here?

  • @jamesguralski5156
    @jamesguralski5156 Год назад

    Does this mostly fix lg refrigerators?

  • @mikiecope
    @mikiecope Год назад

    Had exact prob. Thanks.

  • @withtaniafox
    @withtaniafox 2 года назад

    YOU ARE A GODSEND!!! I spent the whole morning trying to install this thing and then... dang extra wire. Please please please label this one "Supco (U)RCO410 3-in-1 Installation - Leftover Last Wire Hack" for search purposes. I had to watch 12 before finding yours and watching to find out if you were going to have the same issue.

  • @Boxofcrap
    @Boxofcrap 2 года назад

    Great video. I wonder why the company has the diagram for white as the start, black as the common, and red as the run, but they have the wires coming out of the mechanism in the order of white, red, then black… Why confuse us? Is there a reason why it is out of order between the diagram and the physical wiring?

  • @jacquelinemanzano9328
    @jacquelinemanzano9328 2 года назад

    I also have 3 power lines on my GE side by side, just as you show on the video. I splice it into the common wire, it DID NOT work. Thanks for sharing.

    • @mikemd2697
      @mikemd2697 Год назад

      I have same problem. How did you ultimately connect that extra wire? Thanks in advance!

    • @jacquelinemanzano9328
      @jacquelinemanzano9328 Год назад

      I followed the instructions on the package. If you don't have the package, just google the brand you have and it will give you instruction.@@mikemd2697

    • @codyphillips3406
      @codyphillips3406 8 месяцев назад

      Any luck? Mine isn’t working either after that

  • @letstryhonesty11
    @letstryhonesty11 2 года назад

    Good Lord man you make that way more complicated than it needs to be. The thermostat turns on both the fan and the compressor. All you need to do is cut the two power wires and connect them to the two black power wires on the three on one. There is no third power wire. The thermostat is just a switch that breaks the circuit. Now, as far as the probes on the compressor if the common is on the top, run is on the right, start is on the left. If the common is on the bottom you just rotate that triangle so now the common is on the bottom, run is on the left, start is on the right .

    • @ld7103
      @ld7103 Год назад

      My thoughts exactly 😅

    • @michaelcooprider4973
      @michaelcooprider4973 Год назад

      So I connected the two wires that give me 120 power to the black power wires. I also hooked up the start, run, and common wires to the compressor and it did not work. I left the third wire that with to the start relay disconnected and my system will not kick on. My compressor checks out with a multimeter but it will not kick on. Do I need to connect that Start Relay wire to the common as he showed in this video?

    • @ricardoa.denegrimartinez9688
      @ricardoa.denegrimartinez9688 Год назад

      I did the inverter triangle as you said and it is working, but I can't hear when the compressor starts and finish. Question: If I hooked the cables start and run incorrectly, it can still work but maybe frying my compressor by failing to finish it's cycles? 😢

    • @alexandersheets1
      @alexandersheets1 Год назад

      If you wire this thing in wrong and plug it in will it just not start or do you fry the capacitor?

    • @ricardoa.denegrimartinez9688
      @ricardoa.denegrimartinez9688 Год назад

      @@alexandersheets1 I asked that to a supco guy via mail and he answered me this: "No, I have never seen one work that was not wired correctly.".

  • @deannseukumar247
    @deannseukumar247 2 года назад

    Yes i do that but coming on and go kix

  • @kevindynamite
    @kevindynamite 2 года назад

    Yeah but what if how do you hook up the fan and the thermostat

  • @jrelechrelech6898
    @jrelechrelech6898 2 года назад

    I put on the 3in1 and now my fan next to it stops. I'm confused because every wire is correct. Thoughts on what I do wrong here??

  • @houstonivan
    @houstonivan 2 года назад

    So what about the capacitor already with the board and the starter

    • @pajo2012
      @pajo2012 Год назад

      Ignore it,usually it comes included in the kit

  • @trippwhite631
    @trippwhite631 2 года назад

    Mine has 4 wires? Three to starter relay , and then one to the overload ? Any suggestions on how I would wire that up with this part ? I have the part already !

    • @adamanderson418
      @adamanderson418 2 года назад

      Same. I have a pink and blue across from each other. Then a red wire directly under the blue. There is a black wire to the overload.

    • @jaymyers9010
      @jaymyers9010 Год назад

      Did You Figure It Out ?

    • @VitaliiKrivchyn
      @VitaliiKrivchyn Год назад

      I believe you have an inverter compressor. You can not install this kit to inverter compressor.

    • @rayvidal5232
      @rayvidal5232 7 месяцев назад

      Mine is the same. Did you ever get it figured out?

  • @agustinolivarez6021
    @agustinolivarez6021 2 года назад

    I just tried it and my compressor just exploded… don’t try it unless you know exactly what your doing…

  • @rd424
    @rd424 2 года назад

    I appreciate your explanation of left to right with the start and run in relationship to the common. All the videos I saw had the common on the bottom. Mine is on top and I wasn't sure if I had to switch the order

  • @wasimedoo7994
    @wasimedoo7994 2 года назад

    How do you know that is the common from the two black in put wire I like to know

  • @glo1168
    @glo1168 2 года назад

    You must be from where joe Rogan is from

  • @jk24158
    @jk24158 5 лет назад

    Needs a cow bell!