RJ Murray Co., Inc.
RJ Murray Co., Inc.
  • Видео 24
  • Просмотров 38 316
Totaline After-Market Parts
The right part for the job is critical.
We have a full line of Totaline universal aftermarket part and supplies. Check inventory and shop online at www.rjmurray.com/page/hvac-parts-supplies-5.html
Просмотров: 20

Видео

Carrier Weather Series Rooftop Units with EcoBlue Technology
Просмотров 4444 года назад
Carrier Weather Series Rooftop Units with EcoBlue Technology
Carrier WeatherMaster Rooftop Installation by APA in Stamford, CT
Просмотров 1244 года назад
APA's installation of two energy-efficient and environmentally friendly 60-ton Carrier WeatherMaster single-packaged rooftop units on an office building in Stamford, CT. These units were tied into the existing Variable Air Volume (VAV) system. Carrier P Series rooftop units are pre-wired and factory-tested in both cooling and heating modes. All models feature an industrial-grade cabinet with fu...
Carrier EcoBlue Technology
Просмотров 1,1 тыс.4 года назад
The industry’s first beltless direct-drive fan for RTUs is just one of many technological advances that prove that not all rooftop units are created equal. Other enhancements include a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access door and more - all available on this multi-efficiency offering. More at www.rjmurray.com
Who Is RJM
Просмотров 865 лет назад
Get to know RJ Murray Company and the great people behind it! We've been in the heating and cooling business over 85 years and are committed to keeping our community comfortable. With hundreds of HVAC products under one roof, it's easy to stay cool with us!
Noritz EZ Series
Просмотров 235 лет назад
Learn how easy it is to install a Noritz!
FER video
Просмотров 135 лет назад
FER video
ECOBLUE VIDEO SET AIRFLOW
Просмотров 1285 лет назад
ECOBLUE VIDEO SET AIRFLOW
ECOBLUE VIDEO MAINT
Просмотров 1075 лет назад
ECOBLUE VIDEO MAINT
Carrier Sales App
Просмотров 1276 лет назад
Carrier Sales App
Are you ready for summer?
Просмотров 717 лет назад
Are you ready for summer?
RJM Parts and Equipment
Просмотров 1057 лет назад
A quick look at our warehouse, parts, and equipment.
Low Capacity Gas Furnace Training
Просмотров 2857 лет назад
NEW LOW CAPACITY GAS FURNACE by CARRIER CORP. Presented by R. J. Murray Company • Carrier has released a 26,000 Btuh input gas furnace, and it has some important new features. • Your company may not sell large projects with these small furnaces, but someone needs to know how to service them; literally thousands of them will show up in your area in the coming years. Plus, well-insulated and low ...
Carrier Air Purifier - Infinity and Performance Models
Просмотров 1,8 тыс.10 лет назад
Capture and kill mold, mildew, dust, pet dander, bacteria, viruses with the Carrier Infinity or Performance Air Purifier. A must for allergy or asthma sufferers.
Carrier ERV Energy Recovery Ventilator
Просмотров 1,2 тыс.10 лет назад
Bring the fresh air inside your home without sacrificing energy efficiency. Carrier ERV (Energy Recovery Ventilator). Perfect for the "air tight" home.
Carrier University My Learning Center Dealer Video
Просмотров 75310 лет назад
Carrier University My Learning Center Dealer Video
i-Vu Open Systems IP & MS/TP Networks & Addressing & Open Contollers on 3rd Party Systems
Просмотров 13 тыс.10 лет назад
i-Vu Open Systems IP & MS/TP Networks & Addressing & Open Contollers on 3rd Party Systems
I-Vu Open System - BACnet MS/TP Networks Bus Wiring
Просмотров 11 тыс.10 лет назад
I-Vu Open System - BACnet MS/TP Networks Bus Wiring
How to use Shop.RJMurray.com
Просмотров 19410 лет назад
How to use Shop.RJMurray.com
Carrier Packaged Rooftop Units
Просмотров 3,2 тыс.10 лет назад
Carrier Packaged Rooftop Units
How Quiet is the Carrier 23XRV Chiller?
Просмотров 46710 лет назад
How Quiet is the Carrier 23XRV Chiller?
Carrier Heat Recovery Video
Просмотров 33010 лет назад
Carrier Heat Recovery Video
Carrier 30rap video
Просмотров 9210 лет назад
Carrier 30rap video
How to Backup your Carrier I-Vu System
Просмотров 2,8 тыс.10 лет назад
How to Backup your Carrier I-Vu System

Комментарии

  • @RSV4BOY
    @RSV4BOY Год назад

    Hi, This was great! Its hard to get clear and concise info from a Carrier controls guru when you cant ask a formulated question because you don't know the special vocabulary and acronyms. These two videos have answered many questions for me, so THANKS! Who at RJM gave this presentation BTW ( I promise not to bug you.-lol

  • @nategadow4482
    @nategadow4482 3 года назад

    Good job as always

  • @martintovar2537
    @martintovar2537 3 года назад

    Good afternoon, the PROT-485, it is recommended when the communication goes from an interior area to an exterior one or vice versa ... if there are many machines on the roof, they can be placed in the units where the communication is between the interior or exterior or vice versa. ... the a / c unit as such must have its protections against electrical noise so as not to affect it in the future.

  • @emptech
    @emptech 4 года назад

    The title should read, how to back up your I-VU database. I'm working on a customer's system, the AOpen computer is failing and will have to be replaced soon, the hard drive is 120G. It's apparent that this procedure does not back up the system, if it did, it would allow one to format a new hard drive, install an operating system and finally, restore the database. The alternative I see is to place the hard drive in a Linux system, using a Linux utility and mirror the drive to another drive as a backup, or better yet, make an image file of the hard drive that can be saved elsewhere. Jim

  • @pablogeraidine4858
    @pablogeraidine4858 4 года назад

    Please, what are the port settings when using HyperTerminal to set the IP Address?

    • @martintovar2537
      @martintovar2537 3 года назад

      Good afternoon, do the following, download the hyperterminal program, close the field assistant application, enter the program and follow the steps, set for 115200, none and never, then press enter and modify what you need. don't hesitate to ask.

  • @blubu68
    @blubu68 6 лет назад

    Thx for posting. If I have a Ivu 6.5 server on IP through Ethernet cable and a IVU Open Link do they both have to be on the same Sub-net?

    • @martintovar2537
      @martintovar2537 3 года назад

      Good afternoon, they do not necessarily have to be under the same network segment, if they are through the BBMD tool you can configure it, lean on the systems department or it so that they open the ports and if necessary create the rules.

  • @kevinhedges472
    @kevinhedges472 7 лет назад

    All that expensive equipment and they used cheap a$$ fiberboard duct work.

  • @thetearsdry
    @thetearsdry 9 лет назад

    shouldnt the title be how to backup and restore your I Vu system?

  • @StupidPeasant
    @StupidPeasant 9 лет назад

    Would you then install a PROT485 inside each package unit before going down into the building or would it have to be installed inside the building below the roof penetration. This is not clear in the manuals.

  • @dickc711
    @dickc711 9 лет назад

    Technically, and per BACnet/Manufacturers instructions, yes. There should be a PROT485 at each roof penetration. The object is to isolate a lightening strike to the roof.

  • @StupidPeasant
    @StupidPeasant 9 лет назад

    If installing this on many package units on a large roof, the wires would enter and exit the building at every unit. Would it need the surge protector at every unit?

  • @StupidPeasant
    @StupidPeasant 9 лет назад

    You are very clear. Thank you.

  • @RJMurrayCo
    @RJMurrayCo 10 лет назад

    Carrier's recommendations for the configuration, set-up, installation, start-up, and wiring for a BACnet MS/TP network that will provide the best network performance with i-Vu Open Controllers.