Gary Meats Life
Gary Meats Life
  • Видео 47
  • Просмотров 93 164
Seplos Batteries Went Offline
Watch this to discover why it's important to plan, properly install and check your work later. This could save you a serious accident on DIY and even professional installations.
Просмотров: 41

Видео

My Inverter Fuse Melted
Просмотров 33614 дней назад
IMPORTANT - Choose the right fuse! Here you will see the thankfully limited damage caused by using the wrong fuse. Watch the video and see why. Got a DIY 48V battery system? Have more than 1 battery on a busbar system? Then you need the correct fuse. This is what I am now using: www.amazon.co.uk/dp/B0BLMTHNZ1?ref=ppx_yo2ov_dt_b_fed_asin_title You need the correct rating for Amps AND Voltage. Do...
Solar Battery Busbar - Final Day - 5 of 5
Просмотров 313Месяц назад
It's important to ground your batteries, so here is how I did mine. We could leave a big mess of cables and they would work fine, but taking pride in the finished job is an important part of the process and is worth it in the end. What do you think?
Solar Battery Busbar - Adding Another Battery - 4 of 5
Просмотров 201Месяц назад
When you want to add another battery, you need to extend the busbar, but you also need to get the battery into position. That's not always easy. Check out how I add each battery to the system.
Solar Battery Busbar - The Connection - 3 of 5
Просмотров 268Месяц назад
Getting the last of the lug crimps and breakers tied in before connecting the inverter to the busbar and energising the setup. Will it run smoothly? Does it ever?
Solar Battery Busbar - The Install - 2 of 5
Просмотров 223Месяц назад
Check out the grunt work section of the installation. The cutting, the crimping, the pain of sitting on a plastic stool for an hour, or three! Mistakes and miscalculations happen. Correcting them and moving on is how we learn.
Solar Battery Busbar - Planning - 1 of 5
Просмотров 175Месяц назад
This video series is a Thank You to those who have watched and enjoyed the content I have created. The first chapter is a look into how I plan projects off the cuff and is usually confined to the space between my ears. Join me on my thought process and get an insight into how I work through my solar battery challenges. Follow me as I make progress in my goal to become more energy sustainable an...
Battery Cabinet Build
Просмотров 252Месяц назад
Keep your batteries high and dry with one of these easy to build battery wall cabinets. Add foam insulation and an optional door to keep them toasty in the colder months, giving you the best performance from your energy storage. Measurements are for the storage of a Seplos Mason Vertical V2/V3. Adjust to meet your own battery needs. Sorry about the audio. The road noise behind my home is a pain...
Seplos V3 BMS Settings Improved
Просмотров 1,1 тыс.2 месяца назад
Recommended settings which are less conservative than previous settings. A must do if using more than one battery pack. The changed pack and cell parameters are: October 2024 Battery High Voltage Recovery = 56V Battery High Voltage Alarm = 56.8V Battery Over Voltage Recovery = 56V Battery Over Voltage Protection = 57.6V Cell High Voltage Recovery = 3.5V Cell High Voltage Alarm = 3.55V Cell Over...
To Daisy Chain or Busbar Batteries
Просмотров 1 тыс.3 месяца назад
Have you daisy chained your batteries, or are you thinking about it? You might want to consider using a bus bar approach, or risk uneven degradation on individual packs.
Connect Seplos Batteries Together (Daisy Chaining)
Просмотров 2 тыс.3 месяца назад
Want to know exactly how to connect Two or more Seplos battery packs together using the daisy-chain method? This is the video you have been looking for. When daisy-chaining, there are two methods. The method shown here links the first battery to the inverter and the second battery is added to the first battery. This method is the easiest way to setup, but it does place more stress on whatever b...
Seplos V3 BMS Studio Guide (see description for updated settings)
Просмотров 3,2 тыс.3 месяца назад
The Seplos V3 BMS Studio full setup video is a step by step tutorial on where and how to download the studio software and everything else to connect the BMS to your computer for setup. SEE BELOW FOR MY LATEST SETTINGS. Setting shown in the video are too conservative and may cause batteries to not fully charge and balance, especially with more than one battery. I have updated the following param...
How to Remove and Replace Nissan Leaf Seats
Просмотров 8794 месяца назад
Instructional video on how to remove and install Nissan Leaf car seats. Same practice applies to most Nissans from 2010 to 2024. Disclaimer: Undertake instructions at your own risk.
6 Month Carnivore - The End
Просмотров 1404 месяца назад
This is it. 6 months in and there is no other way of saying it, but i'm done. I'm done reporting monthly, but the carnivore way is here to stay. Someone has to eat all the meat the Vegans don't, right :) Seriously though, 6 months in, all is stable and going well. I am down from 110kg (243lbs) to 92kg (203lbs). That's a mass difference of 16% and I am pretty happy with that. Good luck to you if...
Solis Inverter Battery Settings (other options)
Просмотров 2,6 тыс.5 месяцев назад
The same settings for the same equipment won't always work for some setups for various reasons. This could be due to a conflict, or error in BMS settings, or could be a bug, or hardware fault. There are other options and settings you can use, including for alternative uses. This video answers the questions I have been asked and then some.
Nissan Leaf Dash Cam Installation
Просмотров 1,7 тыс.5 месяцев назад
Nissan Leaf Dash Cam Installation
5 Months of Carnivore(ish)
Просмотров 1085 месяцев назад
5 Months of Carnivore(ish)
DIY Battery to Solis Inverter
Просмотров 3,8 тыс.5 месяцев назад
DIY Battery to Solis Inverter
DIY Battery Build Seplos Mason
Просмотров 6 тыс.5 месяцев назад
DIY Battery Build Seplos Mason
Solis Inverter Battery Settings
Просмотров 5 тыс.5 месяцев назад
Solis Inverter Battery Settings
How to wire seplos V3 BMS and active balancer
Просмотров 5 тыс.6 месяцев назад
How to wire seplos V3 BMS and active balancer
4 Month Carnivore
Просмотров 2246 месяцев назад
4 Month Carnivore
3 Month Carnivore
Просмотров 9697 месяцев назад
3 Month Carnivore
2 Month Carnivore
Просмотров 1,9 тыс.8 месяцев назад
2 Month Carnivore
1 Month Carnivore
Просмотров 4,8 тыс.9 месяцев назад
1 Month Carnivore
Day 10 Carnivore
Просмотров 11910 месяцев назад
Day 10 Carnivore
Day 1 Carnivore Diet
Просмотров 29410 месяцев назад
Day 1 Carnivore Diet
It's Over
Просмотров 6411 месяцев назад
It's Over
5 Year Pond Update 2023 (Part 2)
Просмотров 631Год назад
5 Year Pond Update 2023 (Part 2)
5 Year Pond Update 2023 (Part 1)
Просмотров 334Год назад
5 Year Pond Update 2023 (Part 1)

Комментарии

  • @RS.Outdoors
    @RS.Outdoors Час назад

    Good stuff and thinking about getting a second Seplos battery later next year. Do you balance the batteries once a month. I was recommended to do it once they are at 100% charge once a month but not sure on process. Do you just press press the silver button in at back to balance or do you need to press and hold it for a period of time.

    • @GaryMeatsLife
      @GaryMeatsLife Час назад

      They will auto balance if you have the settings done properly and this happens once the cells reach set values. The manual balance button seems to be unnecessary. I make sure my cells are balanced every 7-10 days, or the risk of the SOC falling off a cliff is high. I have seen drops from 60% to 15% when not balanced. It only takes one cell to bring everything down. You can manually balance with a touch of the button once the pack is at 98% or higher (again depending on settings).

  • @halogen25
    @halogen25 День назад

    Thanks for your series - it has been very helpful! Have you been able to access both of your Seplos units in BMS Studio when daisy-chained like this? I am struggling to see more than one at a time.

    • @GaryMeatsLife
      @GaryMeatsLife 22 часа назад

      Always great to know the series is helping people out. I haven't tried to access more than one pack at a time, as I haven't needed or wanted to. I just upload any SW changes I want to each pack, one at a time and leave them do their job of saving me money. Andy on off grid garage has a video on it if you need to see what is happening with the packs daisy-chained. By the way, the method of power connection is not relevant to your question. Only the comms connection matters for your question. I have 3 pack now connected by BusBar and they communicate the same way regardless.

    • @halogen25
      @halogen25 4 часа назад

      @@GaryMeatsLife Thank you! Do you know if the batteries are working together properly for communication with your inverter via CAN?

    • @GaryMeatsLife
      @GaryMeatsLife 4 часа назад

      @@halogen25 Yes, the comms are working fine. In fact, if the batteries are all switched off and I switch on the main battery, the other batteries then turn on. I've only recently discovered this, so I will be seeing if it makes any difference with regards to discharge rates.

  • @SebyLazarovici
    @SebyLazarovici День назад

    EVE ELF280K-V3 batteries

  • @SebyLazarovici
    @SebyLazarovici День назад

    What do you say about a battery pack grouped in 4p16s?...with a single bms seplos V2 and neey active equalizer?...not recommended?...why?

    • @GaryMeatsLife
      @GaryMeatsLife День назад

      It depends on what you are looking for and why you are doing 4p instead of 2p. As long as you get the voltage and capacity you want, everything else is just optimisation, management and aesthetics. I wouldn't be the person to advise on this.

  • @ronaldayling-w7e
    @ronaldayling-w7e День назад

    Just a question what about connecting the earth points shown on the back of the battery

  • @Vde1997
    @Vde1997 7 дней назад

    Hi Gary, so you didnt precharge your inverter or isnt that needed?

    • @GaryMeatsLife
      @GaryMeatsLife 7 дней назад

      Not sure what you mean by pre-charging the inverter. The inverter powers on when there is solar and/or there is a battery connected to it, assuming the isolator switches are on. Maybe you meant pre-charging the batteries? If so, no it is not necessary to do this, but it is advised to get them fully charged as soon as you start using them for your system. The batteries need to regularly top balance, or what will often happen is the state of charge can drop from as high as 50% to 10% (common with LiFePO4 cells if not cycled often) and nobody wants that to to happen when the alternative is paying for expensive grid electricity.

  • @doug1olson
    @doug1olson 9 дней назад

    It would be useful to comment on cleaning the windshield before applying the 3M sticker pad.

    • @GaryMeatsLife
      @GaryMeatsLife 9 дней назад

      I won’t judge people if they don’t clean their windows 🙂. Seriously though. It’s not something that needs mentioning. The line of information needs to stop somewhere and if I have to suggest window cleaning, I may as well tell people they should recycle the packaging.

  • @SandeepSharma-lv3pk
    @SandeepSharma-lv3pk 9 дней назад

    How do you manage to register with Seplos? I am trying its not letting me do the registration :(

    • @GaryMeatsLife
      @GaryMeatsLife 9 дней назад

      Try a different browser and try again tomorrow. If that doesn’t work, you should ask Seplos directly. There could be an issue with their site.

    • @SandeepSharma-lv3pk
      @SandeepSharma-lv3pk 8 дней назад

      @@GaryMeatsLife Thanks a lott it was a site glitch :) one more question did you configured bluetooth app? if Yes then please let me know how you have configured it. Also did you calculated the standby current draw from the inverter? I am trying to get one.

    • @GaryMeatsLife
      @GaryMeatsLife 8 дней назад

      @@SandeepSharma-lv3pk Everything I have done is recorded here. I don't use bluetooth with mine. The Wi-Fi is the better option, as you can access it anywhere. Check the settings in the videos I have posted and if something is not covered, I am happy to add to that.

  • @tigerhill2893
    @tigerhill2893 12 дней назад

    hi I have the same setup but even after 6 months of use the balancing seems to between 25-35 MV , not sure if the balancer is working , I have a 3 battery bank with parallel 2 have the same seplos balancer and one doesn't ? more to less all the 3 banks have the same 23-35mv balancing difference when fully charged , kindly guide

    • @GaryMeatsLife
      @GaryMeatsLife 12 дней назад

      Check out the BMS videos I have in the series. The pack without the balancer won’t balance. You’ll also need to confirm your software is up to date, as the old software was terrible. Andy on Off Grid Garage covers this software update on his channel.

  • @bobminchin
    @bobminchin 12 дней назад

    Thanks for your videos -so helpful and interesting. I am building a seplos 280 mason vertical like yours. Hi, Can you help me please? In the corner of the V3 BMS are three 4 pin connectors. In the kit are cables with three 4 pin plugs (one only has two wires to the on off switch. Please can you tell me the function of each board connector so I don't get it wrong. The latest manual downloaded from seplos, the all important diagram showing the wiring shows the wrong BMS ! Loving your channel and always good to watch the latest one from you Thanks in Advance Bob from UK

    • @GaryMeatsLife
      @GaryMeatsLife 12 дней назад

      Hey Bob. This is the section you want in the wiring video => ruclips.net/video/HO1wgsbChfA/видео.htmlsi=ho4sm8w5EPZVKeQC&t=800 The correct connections from left to right are: 2 pin connector = red/black . Connects to rocker switch on cover. 4 pin connector = red/yellow/white/black . Connects to active balancer. 4 pin connector = black/yellow/white/red . Connects to LCD Everything you need is in the wiring video. Good luck.

    • @bobminchin
      @bobminchin 12 дней назад

      @@GaryMeatsLife Thank you so much Gary. You are a gent of the first order!

  • @MatthewJoseph-q3f
    @MatthewJoseph-q3f 15 дней назад

    Same question here.

    • @GaryMeatsLife
      @GaryMeatsLife 15 дней назад

      @@MatthewJoseph-q3f Thanks for the question. I hadn’t seen the previous one until you asked about it. Answered below.

  • @omerqasimali
    @omerqasimali 16 дней назад

    Hi, i have installed Lead acid tubular batteries but battery SOC not showing in display. Battery voltage is showing. Please suggest.

    • @GaryMeatsLife
      @GaryMeatsLife 16 дней назад

      You will need to select the "user defined" option. The Battery needs to connected to the comms and all signals need to be connected. Try a different comms cable to rule out that potential issue. Beyond that, your BMS settings will may need to be looked at. Lead acid batteries are an entirely different setup to what I use, which is LiFePO4 with Seplos V3 BMS.

    • @omerqasimali
      @omerqasimali 16 дней назад

      @ Thanks for replying. Actually when i connect with bluetooth then i can see the SOC but in wifi plant overview and on the inverter screen it is not showing. That is why i am curious that battery settings might be ok but data logging is not correct

    • @GaryMeatsLife
      @GaryMeatsLife 16 дней назад

      @@omerqasimali Lead acids typically don't have CAN BUS, so maybe that's why you can't get the SOC on the inverter screen.

  • @hasger1941
    @hasger1941 16 дней назад

    Hello Gary thank you for all your hard work and sharing the content, we have also purchased one of these and wondering where we can find a detail explanation of the "basic parameters" under the parameter management.. Some of them we do not understand what they are for

    • @GaryMeatsLife
      @GaryMeatsLife 16 дней назад

      Understanding the parameter is not what these videos are intended for. Getting your batteries working is the design purpose. There is a lot of confusion about parameters and what they do, so I just keep it simple here and share what I use and I hope that gives people what they need.

  • @BirgerKnudsen-jo1nr
    @BirgerKnudsen-jo1nr 17 дней назад

    HI Thanks for a very good video. I have 5 battery with each 15KW and all with Seplos 3 and activ balancer. Inverter is Deye 12 Kw 3 phase Have a problem with communication from battery pack and inverter. It seems like the inverter only can see the first pack. In BMS monitor i see all 5. Also can the 5 battery pack not itself ballace out? It is so one pack is 67%, one is 98% another is 85%. Why is they not to ballance itself? Thanks in advantage Birger from Denmark

    • @GaryMeatsLife
      @GaryMeatsLife 17 дней назад

      Your inverter will only see the first battery and the batteries will then communicate with eachother via their daisy-chain comms connection. It is normal for batteries to be at different percentages, especially if you have connected them by daisy-chain method. There is an improvement when using a central bus bar. The best thing to do is make sure your all your battery packs have good parameters set and equally as important, you should get them to a full charge at least once per week. If you are able to fully charge and fully discharge in the next cycle, you will top and bottom balance them, but the economics of this will depend on your system, or more to the point, the type of tariff you are on with your electricity provider. I have a 4 hour window to charge my batteries, so I tend not to drain mine and try keep them above 50% if possible for the darker months. I too am still learning and I am considering another method for keeping the batteries closer to the same state of charge.

    • @BirgerKnudsen-jo1nr
      @BirgerKnudsen-jo1nr 17 дней назад

      @@GaryMeatsLife Thanks for answer. It makes good sense. Please tell me a little more about the central bus bar. It sounds good. It is a good saying "Learning by doing" I thinh we all do this🤩

  • @TheFlyingJanner
    @TheFlyingJanner 18 дней назад

    Just get a big Jean Muller and some decent cartridge fuses in there. Handy isolator too.

  • @malcr4841
    @malcr4841 20 дней назад

    Another interesting video, thanks. It looks to me that it was caused by a high resistance joint on the left of the carrier. From the video the brass looks polished which leads me to think that its poor quality. The heat transfer melted the fuse link (which its not strictly designed to do), so you were lucky. Looking forward to your next offering

    • @GaryMeatsLife
      @GaryMeatsLife 20 дней назад

      It definitely seems to be due to the product being inferior. Serves me right for being drawn to a fancy volt meter. Next video might look at costs, or making doors for the cabinets if the temps dip low.

  • @NedNew
    @NedNew 20 дней назад

    Regarding the uneven state of charge (SOC) with the batteries, I noticed the same with mine. I have two same model batteries, both with equal cable size and length connected to the busbar. One tends to discharge about 8% more than the other over time. As you mentioned, a full charge puts them in sync again and they stay reasonably paired for a week or so after that. I now do a full charge every week to avoid this drift. All is well now.

    • @GaryMeatsLife
      @GaryMeatsLife 20 дней назад

      Thanks for letting me know. There is definitely an improvement with the busbar, but my understanding was that by adding a busbar, the batteries would charge and discharge at the very same rate. I might experiment later and calculate the overall distance of cable each battery connector must travel before hitting the final busbar connector. If I add more cable to battery 2 and more again to battery 1 so that each battery has the same length of cable to travel to the inverter, there should be no reason for uneven discharge rates.

  • @morisz25
    @morisz25 20 дней назад

    Hello, i recomand Weicon dor stripping conductor

  • @FarmsVilla
    @FarmsVilla 20 дней назад

    That amount of heat on the fuse is concerning. What sort of amperage are you drawing from the batteries? Was there a loose connection on the fuse by any chance?

    • @GaryMeatsLife
      @GaryMeatsLife 20 дней назад

      Yes, of course there is always a chance the connection becomes loose, or there is a poor mechanical connection due to crappy equipment, which is what I suspect happened. I had checked the connections the day after and gave them another twist to make them tight. I planned to check again at months end, but this had already happened. The reason for the arcing, is the low voltage rating. So when the fuse blew, the low voltage rating allowed the arc to form and melt the cover. Fascinating stuff, but I am glad the equipment is not inside the house. The new fuse holder is a much safer design. No issues there and it's still solid (checked this morning). If it did fail, it would be less likely to lead to any arcing due to the rating now being above the voltage of the system. Check your connections man.

  • @paulharker5052
    @paulharker5052 20 дней назад

    Hi thanks for videos just quick question on the ac to consumer unit are you running it on a 10mm flex to a 40amp mcb? Thanks

    • @GaryMeatsLife
      @GaryMeatsLife 20 дней назад

      I would assume it's 10mm flex, but I don't honestly know. The inverter was commissioned by an electrician and as such, I just let that work be done without much interest from my side. I don't know where you're from, but in Ireland, we are not allowed open the cover of the consumer unit and the AC cable for the inverter is out of sight behind the cement board, so I don't know what was used and I haven't been curious enough to check. I can say that it's on a 32A breaker, which makes sense to me, as it's a 5kW inverter and below 25A. The Solis 6kW unit is also fine on a 32A breaker, as it is also at around 25A or below to meet the NC6 requirements for export to the grid. Only when you go to the 8kW+ inverter might you need a 40A breaker. Separately, my EV charger is a 7kW unit and draws up to 32A, so that is on a 40A breaker and shared priority switch with my Triton T90 is a 9kW shower, so that needs a 40A breaker. I think the heaters (2) in the T90 are 4.5kW units, but they would rarely, if ever actually pull that. I haven't observed the shower pull more than 7kW on full power.

  • @haysdb
    @haysdb 22 дня назад

    The BMS manual says “Differential pressure alarm is only a prompt, without any action”. “Balancing Opening Differential Pressure” and “Balancing end differential pressure” (manual descriptions for parameters 82 and 83) would seem to be the parameters controlling balancing? Or maybe one is for passive balancing and 100, 101 are for active balancing?

    • @GaryMeatsLife
      @GaryMeatsLife 22 дня назад

      Good questions, some of which have been put to Seplos and the answers have not been consistent. This is why DIYers have had to experiment with these. The descriptions in the parameters are unclear in many cases and some do not do what they should when changed. I suspect this is due to default software being updated with description changes remaining the same even if the parameter no longer applies. All I can say is the settings I have shared are working for me, with the exception of an inverter frequency alarm I get when the pack is at 100%. I am working on a solution, but the pack functions perfectly fine.

    • @haysdb
      @haysdb 22 дня назад

      @ I guess all we can do is change things and observe what happens. I’ve put together a spreadsheet of all of the parameters, the descriptions from the BMS 3.0 manual (which are frequently different), the default values per the manual or from my battery manual, and your recommended settings. I’ll add comments if I learn more what each setting actually does.

    • @GaryMeatsLife
      @GaryMeatsLife 22 дня назад

      @@haysdbPlease share anything useful you learn. I’ll keep the settings up to date in the description

    • @haysdb
      @haysdb 22 дня назад

      @@GaryMeatsLife 👍

  • @haysdb
    @haysdb 22 дня назад

    What was the specific problem you were having before changing the default settings? Active balancing wasn’t working? Cell and pack High Voltage needed to be increased to trigger active balancing?

    • @GaryMeatsLife
      @GaryMeatsLife 22 дня назад

      OV Battery alarms were being triggered daily.

    • @haysdb
      @haysdb 22 дня назад

      @@GaryMeatsLife is this because the inverter was not in sync with the BMS? It was overcharging the battery? So increasing the BMS Over Voltage settings brought things into alignment?

  • @dumitruluca5119
    @dumitruluca5119 22 дня назад

    Hello Garry! I assembled a Seplos kit with Seplos BMS ver. 3A. Everything went Ok, including connection with BT and Studio. This was so, until recently, when the battery shuts down after 5 sec from power-on. The Studio displays a temp fault (-273.1 deg.) along with other alarms. Checked the four NTC sensors and they have 11.4-11.6 kOhm. Still the Seplos engineer insists there is a PCB issue. I am in a middle of nowhere… Any hint? Thank you!

    • @GaryMeatsLife
      @GaryMeatsLife 22 дня назад

      @@dumitruluca5119 If all the connections are correct, I would follow the recommendation of the engineer. PCB may need to be replaced?

    • @dumitruluca5119
      @dumitruluca5119 22 дня назад

      Thank you for considering my querry. Seplos promissed to send me free PCB replacements. Hope to get the BMS repaired/replaced if the problem isn’t there where they are suspecting.

  • @haysdb
    @haysdb 23 дня назад

    How can the pack voltages ever be triggered if they’re just the cell voltages times 16?

    • @GaryMeatsLife
      @GaryMeatsLife 23 дня назад

      I think the answer is in the question.

    • @haysdb
      @haysdb 22 дня назад

      @@GaryMeatsLifeNo. When will the pack voltage ever trigger at 57.6v when the cell voltage is set to 3.60? One cell will always trigger charging to stop before the pack ever hits 57.6v. Wouldn’t you want the cell voltage to be slightly higher than the pack voltage, to allow one cell to get close to 3.65 without shutting off charging? This is how the default is set that you’ve overridden.

    • @GaryMeatsLife
      @GaryMeatsLife 22 дня назад

      @ The first video shows the original settings which were conservative. The pack voltage is back to default. With the existing settings, my pack is reaching 100% SOC and is balancing. I am still experimenting with this, but for proper testing, I wait at least a month before making any software changes.

    • @haysdb
      @haysdb 22 дня назад

      @@GaryMeatsLife was it not balancing with the default settings? I have two Seplos 104-L 10.6 kWh batteries on the way. They have 2A active balancing. The sales guy mentions needing to set things up right to get active balancing to work but hasn’t answered my question about how to specifically do that. As far as I know there is no button to trigger active balancing, but it seems like the Cell Diff Pressure Alarm and Recovery would take care of turning it on and off. Have you done anything with the low voltage settings? According to the battery manual Battery Under Voltage Protection is set to 40.0. This is way too low. Cell Under Voltage Protection is set to 2.7, which is reasonable.

  • @ЕлиянПетров-я9е
    @ЕлиянПетров-я9е Месяц назад

    Tomorrow I will see Best Regards

  • @ЕлиянПетров-я9е
    @ЕлиянПетров-я9е Месяц назад

    Is it normal when balancer button always blinking?

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      No. If it has not turned off after a couple of hours by itself, then it it is likely you have not connected it into the right seat.

  • @Irishyoutubers
    @Irishyoutubers Месяц назад

    Thanks, Gary, for the informative videos with the cars. Our Son Luke (Ginger) loves cars, and i dont know any mechanics in our family. So videos like this make his day !!!!

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      No problem. I'll keep Luke in mind for the next car video 😎

  • @sub3marathonman788
    @sub3marathonman788 Месяц назад

    I too own a Nissan LEAF (2022), and I'm greatly appreciative of your video. My question is, at 25:22, the original factory fuse box is shown. Later you show the installation of the add-a-fuse kit, at 28:02 to 28:48, both were put into existing fuse locations (Blower 1, Blower 2). So why not just put them in the two already empty slots, instead of pulling those original fuses? I'm wondering if I'm missing something, that it's technically better to use an original fuse location, or if once again, you're proving that you're a glutton for punishment, as stated earlier. 😃

    • @GaryMeatsLife
      @GaryMeatsLife 15 дней назад

      @@sub3marathonman788 The reason for using the blower fuse location is that I know these pathways are only energised when the car is powered on. I didn’t want to use an always on fuse and I didn’t want to start fishing for other locations when I knew from the cover which location to tap. This is why the fuse kits are included. Not everyone has a multimeter, so I chose the easiest hardwire installation method that most people can easily follow.

    • @MatthewJoseph-q3f
      @MatthewJoseph-q3f 15 дней назад

      @@GaryMeatsLife This video is so greatly appreciated. Exactly what I needed. Now I just need to wait until April so it’s warm enough to actually do the install. Thanks again.

    • @GaryMeatsLife
      @GaryMeatsLife 15 дней назад

      @@MatthewJoseph-q3f What if you needed it before April? Put on a warm coat and you'll be done in no time. You'll be glad you did. Half the work is inside the car with the door closed 😁. Of course, if where you live is -20 degrees Celsius, I understand. Best of luck with the install.

  • @ИльяСидоров-г3у
    @ИльяСидоров-г3у Месяц назад

    Please help. How to balance the cells in this battery

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Use the settings in the video. Updated settings are in the description. Then let the pack charge to 100% and it will auto balance.

    • @ИльяСидоров-г3у
      @ИльяСидоров-г3у Месяц назад

      Thank you

  • @kenbone4535
    @kenbone4535 Месяц назад

    Have you done, or can you do a Seplos settings episode for the Solis/Seplos config, after my JK BMS died, ive just got a Seplos one. Inverter is the same Solis 5k Hybrid. Many Thanks.

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      @@kenbone4535 The whole video series is based on the Seplos and Solis combination, including Seplos BMS configuration. Take a look at the other videos in the series and you should see what you need. They are set in order, so maybe skip the first 2 videos, which are build and wiring ones.

    • @kenbone4535
      @kenbone4535 Месяц назад

      @@GaryMeatsLife many thanks, ive watched most of them over a few times 😁 whats your can setting in the BMS itself, to make it work with the Solis. Thx

    • @kenbone4535
      @kenbone4535 Месяц назад

      BTW I'm running an old leaf 24 pack that I've repurposed.

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      @@kenbone4535Plyontech protocol as standard. As it’s the default, I hadn’t mentioned it.

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      @@kenbone4535 brilliant. I had two of those cars. Currently our second EV is a 40kWh Leaf. I do hope that battery is not in the house. I keep my LiFePO4 outside even though they are very safe.

  • @danylonazarenko5199
    @danylonazarenko5199 Месяц назад

    Hi Garry, among those posted settings, there's missing parameter 102 (Charging request voltage). Assume it is 57.6V, but nevertheless would you please share the same.

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      ruclips.net/video/Ex8SXszAVLs/видео.htmlsi=g0PsZAH-NFBCPkUC&t=450 Timestamp 7:30 you can see line 102 and it is indeed 57.6V Also note I set my inverter to 99% for full SOC as I had been getting grid OV-ILLC alarms when the pack was at peak voltage. My packs seem to be doing very well with full charges, no alarms and no sudden voltage drops. You can achieve the same cell voltage by changing the 3.5V setting to 3.465V

    • @danylonazarenko5199
      @danylonazarenko5199 25 дней назад

      One more hint to all of us. I have enquired from Seplos and they told me how to make active balancer activate automatically. Actually, it is activated by Cell difference pressure(Voltage) alarm set in Parameter 100. In my case and also yours it was factory set to 500mV. So changing this setting to 50mV will be activating active balancer at 50mV Cell voltage difference even when active balancer is off. Recovery parameter 101 need to be adjusted accordingly to 20-30mV or so.

    • @GaryMeatsLife
      @GaryMeatsLife 25 дней назад

      @@danylonazarenko5199 Good to have that confirmed.

  • @qwertyasdfghg7714
    @qwertyasdfghg7714 Месяц назад

    Hi Gary, do you know what is the no-load power consumption of the inverter you are using ? I am planning to buy the same inverter but need to check standby time. Please let me know. Thanks for nice videos very helpful 🙏

  • @kenbone4535
    @kenbone4535 Месяц назад

    I concerned on the weight, relying a lot on those wall anchors.

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Don’t be. A single anchor is more than enough to hold the weight of the cabinet and battery. I’ve put several into each cabinet. Just as an example, the worst M10 bolt will hold 200kg with proper anchor bolts holding many times that before sheering. The reason for adding more bolts is to spread the load across the wooden structure.

  • @albyus
    @albyus Месяц назад

    Hi Gary, I have a question, do you know how I can limit the battery charge to 10A? Which setting should I change? Thank you !!!

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      This will be in your inverter settings.

    • @haysdb
      @haysdb 22 дня назад

      You want to never charge the battery above 10A? Why so low?

  • @stevenNicholson-y1d
    @stevenNicholson-y1d Месяц назад

    You need to put something Inbetween your earth bar and the foil it could become live ?

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Yes. There are rubber ring gaskets behind the earth bar. Though I plan to install on a small plastic block. Good spot by the way.

  • @stevenNicholson-y1d
    @stevenNicholson-y1d Месяц назад

    Hi where did you get dc isolators boxes from I have a similar setup to you

  • @alanslattery5954
    @alanslattery5954 Месяц назад

    Well done Gary, Hugely informative. Thanks for taking all the time to capture everything. I think you have convinced me to try and build a 2 battery system over the next few months.

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Go for it! I’m now planning an easy comms access solution should I need to access the BMS or change settings.

  • @FarmsVilla
    @FarmsVilla Месяц назад

    I used the same bus bars on my upgrade. 👍🏻 Gotta love Amazon! 🤣🤣

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Yeah. They’re good quality. I hope you didn’t put washers behind the nuts 😅

  • @kevincoholan7604
    @kevincoholan7604 Месяц назад

    Hi Gary, excellent videos. Where did you get the extra 25mm2 cable?

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Ordered on Amazon. Order by the metre

    • @kevincoholan7604
      @kevincoholan7604 Месяц назад

      @GaryMeatsLife I'll look at that so. Thanks

  • @cgutowski471
    @cgutowski471 Месяц назад

    Great video and very helpful. Do you know if Sepolos v2 (10e) and v3 can be daisy chained together?

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Not my area of expertise, but here’s my understanding. Physically yes, but the BMS are not compatible. They would need to connect to each other without comms link. Choose one BMS type to connect to the inverter. Don’t link the other BMS to anything. The unconnected battery will charge and discharge anyway alongside the connected battery.

    • @cgutowski471
      @cgutowski471 Месяц назад

      @@GaryMeatsLife Thanks for the quick reply. All these BMS' are frustrating. I guess that would work like you described. Capacity would not be reported correctly but SOC would since current would be flowing in/out all of them.

  • @NedNew
    @NedNew Месяц назад

    Nice work.

  • @morisz25
    @morisz25 Месяц назад

    Good job 🎉

  • @lpkitson
    @lpkitson Месяц назад

    Hi, great videos, very informative. On the same journey as you. Just wondering where did you get your batteries?

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Great to hear about others getting value from the content and taking a similar route. The battery cells are all from NKON in the Netherlands and the cases are from Fogstar in the UK.

  • @seanfagan8490
    @seanfagan8490 Месяц назад

    You could build a house on top of them cabinets😂

  • @NedNew
    @NedNew Месяц назад

    Very interesting, I the detail you're showing, it for a very enjoyable video. Nice work. p.s I'm no expert but I think that the cables from the battery only need to be equal in length for each polarity, e.g you could have 3 red/positive cables of 1m each battery and 3 black/negative of 1.2m. As long as the positives are the same length and the for the negatives.

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Thanks. Glad you enjoyed it. You are correct. I erred on the side of caution and kept everything the same relative length regardless of polarity.

  • @ozanam
    @ozanam Месяц назад

    Can you charge these fully in the 4 hour window at night and charge a car?

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Great question. Charging the EV is sort of separate and only matters because of my incoming limits. My main fuse is 80A for the house. My inverter is 5kW. This gives me 20kWh over the 4 hour window. That’s half of my useable capacity, but when I have solar, some of that will top up the batteries and will export power when batteries are full. What I have is a nice big buffer suited to my use case. I will also be adding a DC-DC charger to the loop. It will be a 3000W charger on a 25A timed smart switch. That will give me another 12kWh if needed. I predict that it will be rare I would see a need for the full 40kWh per day and when a lot is used, there is some buffer built in. Then, during brighter months, I’ll probably dump 20kkWh per night to the grid before charging at the cheap rate to fill up again. It’s a working progress.

  • @mick.Walker
    @mick.Walker Месяц назад

    I may be wrong but, by the look of the setup, you don't have one central busbar to terminate all three batteries, you seem to have done nothing more than move the connection point on each battery down to underneath then reconnected them back up in parallel, or am I missing something

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      Hi Mick. Thanks for the comment. Yes, I think you’re missing a bit here. Have you watched the video prior to the series just released? The central busbar is all the cabling and busbar connections below the cabinets. The reasons for the busbar system was to even the load on each battery and to be able to isolate each battery individually. There is no need to isolate all 3 at once, so I have put the inline fuse between the inverter and busbar. If I wanted to isolate all 3, I have 3 breakers instead of 1 master breaker (if you will allow that term). This takes about 2 extra seconds to turn them all off and allows me to disconnect a single battery from the system if it needs maintenance. The previous setup worked, but was drawing power unevenly, draining battery 1 faster and reducing the useable capacity. This new setup is so much more functional than what was in place before. I hope that answers your question. Are you considering something similar?

    • @mick.Walker
      @mick.Walker Месяц назад

      you have connected battery 3 busbar to battery 2 busbar then those two to battery 1 busbar, then to a fourth busbar then to the inverter, is that correct,

    • @GaryMeatsLife
      @GaryMeatsLife Месяц назад

      @@mick.Walker No. You might be getting mixed up because the location of the Battery 3 breaker is on the right hand side of Battery 2 cabinet. It's better to see the breakers as 1,2 & 3 and ignore the location of them relative to the cabinet they are mounted. The breaker 3 location was chosen to allow for a fourth breaker to be placed to the right of it (left side of cabinet 3) if I decided to add another battery. 4 batteries would fit inside the 3 cabinet space with minor changes needed. You will see at time stamp 14:00 that there is a partially cut breaker hole for a fourth breaker which I decided to patch up having decided (for now) to not get a fourth battery. Each battery has its own breaker and then each breaker connects to the busbar system below the cabinets which then runs to the inverter, which in turn has a 150A inline fuse on the positive cable.

  • @dbuts5136
    @dbuts5136 Месяц назад

    Good man

  • @dbuts5136
    @dbuts5136 Месяц назад

    I'll have to tap my leap card.

  • @GaryMeatsLife
    @GaryMeatsLife Месяц назад

    5 Videos to be rolled out in this series. Video 2 an hour after this one. Video 3 an hour later. Videos 4 and 5 drop tomorrow. The footage is pretty raw and I have given as much info as possible without getting too deep into the process. I hope you all get something from this. Happy Days!