MJF MECHANICAL
MJF MECHANICAL
  • Видео 313
  • Просмотров 262 355
LEAK THROUGH CEILING FROM HELL..!!!
We were brought in to fix what seemed like a small issue, but it quickly turned into a full-blown disaster! 💧 Our client experienced a catastrophic leak that caused major damage to their home, and we captured the entire process of identifying the source, managing the chaos, and executing the repairs.
If you've ever had a leaky ceiling or want to avoid a disaster like this, don't miss the valuable tips at the end! 🔨
Don't forget to LIKE, SUBSCRIBE, and COMMENT your own nightmare home repair stories! 🏡👇
#LeakyCeiling #HomeRepairFail #DisasterFromHell
Просмотров: 319

Видео

"REPAIRING 92 YEAR OLD CUSTOMER'S GROHE SHOWER VALVE"
Просмотров 3313 месяца назад
"REPAIRING 92 YEAR OLD CUSTOMER'S GROHE SHOWER VALVE"
WATCH HOW WE INSTALL THIS 60"X30" AMERICAST BATHTUB FOR THIS LOVELY CUSTOMER OF OURS !
Просмотров 5753 месяца назад
WATCH HOW WE INSTALL THIS 60"X30" AMERICAST BATHTUB FOR THIS LOVELY CUSTOMER OF OURS !
THERES NO POWER AT MY THERMOSTAT !!! MY AC IS NOT WORKING !! I NEED YOU NOW !!
Просмотров 4613 месяца назад
THERES NO POWER AT MY THERMOSTAT !!! MY AC IS NOT WORKING !! I NEED YOU NOW !!
A.O. SMITH CYCLONE BTH 120 CONDENSING WATER HEATER WITH AN IGNITION FAILURE
Просмотров 7564 месяца назад
A.O. SMITH CYCLONE BTH 120 CONDENSING WATER HEATER WITH AN IGNITION FAILURE
ANOTHER PACKAGED RTU BEING REPLACED ! HUGE SHOUTOUT TO MY BUDDY MIKE AT R&J RIGGING ON LONG ISLAND !
Просмотров 3105 месяцев назад
ANOTHER PACKAGED RTU BEING REPLACED ! HUGE SHOUTOUT TO MY BUDDY MIKE AT R&J RIGGING ON LONG ISLAND !
BACK AT THAT CARRIER MINI SPLIT CONDENSER AND BAD REVERSING VALVE
Просмотров 7535 месяцев назад
BACK AT THAT CARRIER MINI SPLIT CONDENSER AND BAD REVERSING VALVE
HOW TO REBUILD A CONTINUOUS WASTE FOR A DOUBLE COMPARTMENT SINK
Просмотров 8665 месяцев назад
HOW TO REBUILD A CONTINUOUS WASTE FOR A DOUBLE COMPARTMENT SINK
6AM THE CRANE IS DUE TO ARRIVE FOR ANOTHER BEAUTIFUL INSTALL !!
Просмотров 8285 месяцев назад
6AM THE CRANE IS DUE TO ARRIVE FOR ANOTHER BEAUTIFUL INSTALL !!
THEY WANT MJF MECHANICAL TO DO WHAT ? NO THANK YOU !!
Просмотров 9465 месяцев назад
THEY WANT MJF MECHANICAL TO DO WHAT ? NO THANK YOU !!
ANOTHER BEAUTIFUL CARRIER DUCTED AC ONLY SYSTEM INSTALL
Просмотров 9085 месяцев назад
ANOTHER BEAUTIFUL CARRIER DUCTED AC ONLY SYSTEM INSTALL
6 YEAR OLD WARRANTY SWAP OF THIS COMMERCIAL GRADE PRO LINE SERIES PCG-75
Просмотров 3616 месяцев назад
6 YEAR OLD WARRANTY SWAP OF THIS COMMERCIAL GRADE PRO LINE SERIES PCG-75
PROPOSED TO HAVE CONDENSER SWAPPED OUT OR TAKE ADVANTAGE OF CON ED'S CLEAN HEAT PROGRAM NEW INSTALL
Просмотров 1,1 тыс.6 месяцев назад
PROPOSED TO HAVE CONDENSER SWAPPED OUT OR TAKE ADVANTAGE OF CON ED'S CLEAN HEAT PROGRAM NEW INSTALL
SOMEONE TELL ME "WHY" ?? ESTIMATE WAS GIVEN FOR A NEW ROOFTOP UNIT, LET'S BRING IN THE CRANE !!
Просмотров 6936 месяцев назад
SOMEONE TELL ME "WHY" ?? ESTIMATE WAS GIVEN FOR A NEW ROOFTOP UNIT, LET'S BRING IN THE CRANE !!
BE BACK TOMORROW TO FOLLOW UP WITH THIS LOVELY CLIENT !! LET'S REPLACE THIS R-22 SYSTEM !!
Просмотров 2276 месяцев назад
BE BACK TOMORROW TO FOLLOW UP WITH THIS LOVELY CLIENT !! LET'S REPLACE THIS R-22 SYSTEM !!
HERE DOWN SOUTH TO LOCATE THIS SEWER AND TO ADD ANOTHER 15 FIXTURE UNITS TO IT FOR THE NEW ADU
Просмотров 8246 месяцев назад
HERE DOWN SOUTH TO LOCATE THIS SEWER AND TO ADD ANOTHER 15 FIXTURE UNITS TO IT FOR THE NEW ADU
WHICH ONE OF THESE BRANDS DID WE INSTALL TODAY ? TAKE A GUESS !
Просмотров 5066 месяцев назад
WHICH ONE OF THESE BRANDS DID WE INSTALL TODAY ? TAKE A GUESS !
THREE 3 TON MINI SPLIT SYSTEMS IN A HOUSE THATS ONLY 1200 SQUARE FEET ? WHAT THE F$&K ?
Просмотров 1,8 тыс.6 месяцев назад
THREE 3 TON MINI SPLIT SYSTEMS IN A HOUSE THATS ONLY 1200 SQUARE FEET ? WHAT THE F$&K ?
HOW TO REPLACE A FROST FREE HOSE BIBB !!! & HOW TO RESPOND TO NASTY EMAIL ???
Просмотров 6347 месяцев назад
HOW TO REPLACE A FROST FREE HOSE BIBB !!! & HOW TO RESPOND TO NASTY EMAIL ???
ANOTHER BATHROOM BEING ROUGHED IN !! CHECK OUT TO SEE HOW IT GETS DONE !!
Просмотров 6017 месяцев назад
ANOTHER BATHROOM BEING ROUGHED IN !! CHECK OUT TO SEE HOW IT GETS DONE !!
LEARN HOW TO FLY AT HERITAGE FLIGHT ACADEMY ON LONG ISLAND AT MACARTHUR AIRPORT !!
Просмотров 4587 месяцев назад
LEARN HOW TO FLY AT HERITAGE FLIGHT ACADEMY ON LONG ISLAND AT MACARTHUR AIRPORT !!
LET'S REPAIR THE SECOND FLUSHOMETER FOR THE WEEK THATS LEAKING !!
Просмотров 5557 месяцев назад
LET'S REPAIR THE SECOND FLUSHOMETER FOR THE WEEK THATS LEAKING !!
HERE TO RELOCATE THESE RHEEM CONDENSERS !!
Просмотров 5398 месяцев назад
HERE TO RELOCATE THESE RHEEM CONDENSERS !!
UN - GRATEFUL CUSTOMER GETS THE HORNS !!
Просмотров 7208 месяцев назад
UN - GRATEFUL CUSTOMER GETS THE HORNS !!
HERE TO RUN A FEW SERVICE CALLS !! LET'S ATTEND TO THIS NEW CUSTOMER !!
Просмотров 5118 месяцев назад
HERE TO RUN A FEW SERVICE CALLS !! LET'S ATTEND TO THIS NEW CUSTOMER !!
HERE TO INSTALL ABOUT 70 FEET OF HAYDON HYDRONIC BASEBOARD. LET'S GET IT DONE !!!
Просмотров 4198 месяцев назад
HERE TO INSTALL ABOUT 70 FEET OF HAYDON HYDRONIC BASEBOARD. LET'S GET IT DONE !!!
HOW TO CLEAR SEWER STOPPAGE THROUGH FAI
Просмотров 4778 месяцев назад
HOW TO CLEAR SEWER STOPPAGE THROUGH FAI
LET'S MAKE THIS REPAIR ON THIS VINTAGE TOILET AFTER THE FIRST PLUMBER FAILED TO DO SO
Просмотров 6918 месяцев назад
LET'S MAKE THIS REPAIR ON THIS VINTAGE TOILET AFTER THE FIRST PLUMBER FAILED TO DO SO
CUSTOMERS DECISION REVEALED !! NEW EVAPORATOR COIL GOING IN ON THIS AMERICAN STANDARD AIR HANDLER.
Просмотров 4498 месяцев назад
CUSTOMERS DECISION REVEALED !! NEW EVAPORATOR COIL GOING IN ON THIS AMERICAN STANDARD AIR HANDLER.
APOLLOS POWER PRESS LINE IS HERE TO IMPRESS ON THIS LOW PRESSURE STEAM REPAIR THATS GETTING DONE
Просмотров 1 тыс.8 месяцев назад
APOLLOS POWER PRESS LINE IS HERE TO IMPRESS ON THIS LOW PRESSURE STEAM REPAIR THATS GETTING DONE

Комментарии

  • @marriagepartnersministry5942
    @marriagepartnersministry5942 5 дней назад

    flushing doesnt get the oil out. you have to skim the boiler. then add a antisurge or baking soda and use ph test strips to ensure ph is 9-10

  • @jamesa6272
    @jamesa6272 5 дней назад

    Another know it all who knows nothing. If you know everything lady than you fix it

  • @peterdunn920
    @peterdunn920 9 дней назад

    Hi Mike, I live in the Pocono, part of the state that voted for Trump and helped him win the election! I have a VXT 120 and was told it had to be replaced and quoted a price of $2780..00 to swap it out. One problem besides the price was that the reason the boiler was filling with water was a pin hole in the domestic coil. Glad I called another plumber , he charged me a little over $500.00 to diagnose the problem and replace the coil. He even let me buy the coil so no markup on price.

  • @2pugman
    @2pugman 9 дней назад

    I put Steam Clean in the boiler and it surges a few inches. Can I just add some Surge protection to the boiler ? The Ph is at 7.

  • @tmactheplumber4966
    @tmactheplumber4966 17 дней назад

    Have a Happy Thanksgiving.

  • @squ696
    @squ696 21 день назад

    Pros bro.

  • @FX10606
    @FX10606 24 дня назад

    Drill a hole before the diverter perform combustion analysis there , another hole after the diverter for draft test .

  • @skullfoot
    @skullfoot 25 дней назад

    WOW, never seen that crimping tool.

  • @ayaaninstitute10243
    @ayaaninstitute10243 Месяц назад

    Very cool video. Thanks for sharing 🙌

  • @bryanalbright3019
    @bryanalbright3019 Месяц назад

    Sounds like you don't want gay followers. Nobody ask who Iive with while working for them.😮

  • @StevenSchmidt-r9l
    @StevenSchmidt-r9l Месяц назад

    Hi good morining i had 2 plumbers come down to fix this they couldnt do it. after watctching this i was able to fix it on my own. i didnt remove the entire pump but i cleaned it and and put everything back togather it worked

  • @brianlutzak
    @brianlutzak Месяц назад

    I've had some of those old house battles. So satisfying when you finish it. Good work Mike!

  • @gaby03261
    @gaby03261 Месяц назад

    Hi MJF. Can I have 2 water meter in a 2 Family house in New york ?Im been charge 159% for wastewater . Can you please advise me

  • @anthonyfaulkner3205
    @anthonyfaulkner3205 Месяц назад

    So how much would you charge to change these items?

  • @brucebigbie1537
    @brucebigbie1537 2 месяца назад

    I just had the same issue with my brand new cold shot. Have you used it since and was it successful?

  • @ACTPlumbing-d3i
    @ACTPlumbing-d3i 2 месяца назад

    nice job on this one though! where did you get that threading/ thread cleaning tool and what is it called?

  • @ACTPlumbing-d3i
    @ACTPlumbing-d3i 2 месяца назад

    you use enough teflon?

  • @ACTPlumbing-d3i
    @ACTPlumbing-d3i 2 месяца назад

    Do NOT listen to this guy if youre doing this project LMAO

  • @bobbygatto5206
    @bobbygatto5206 3 месяца назад

    Oh my God, the dog barking I was at a job today on 51st St. between 1st and 2nd Ave. and they had a little dog that barks so loud give me a fucking headache all day long and I hear the fucking dog brings back memories this video lol

  • @ranesrollins9144
    @ranesrollins9144 3 месяца назад

    Looks like a thin slab……

  • @daveg8918
    @daveg8918 3 месяца назад

    Are you in Florida or New York? Because I would think In New York that would be an issue ?

  • @F12255
    @F12255 3 месяца назад

    im not a plumber and all joking aside. is that deep enough?

  • @celena2033
    @celena2033 3 месяца назад

    This is a public safety issue. No IPC, UPC nor Milwaukee would approve your marketing this equipment.

  • @celena2033
    @celena2033 3 месяца назад

    List of reasons why if he welds it looks like bird poop. 1)Underground work needs to be sleeved and metallic taped so it can be located by utility companies. 2) only an unskilled plumber would use sch. 40 PVC underground.

    • @travisdoe4663
      @travisdoe4663 3 месяца назад

      Why? PEX is raided for underground use and is more flexible then pvc and less likely to burst in freezing temps.. We use black poly supply lines around here, unless we're dealing with really high pressure.

    • @celena2033
      @celena2033 3 месяца назад

      ​@@travisdoe4663if frozen temperatures is an issue, you're too shallow, you're not sleeved, it's not taped (location marked), you're using a ball valve, your pipe is undersized for the volume. You don't branch 2: 3/4" off a 1" branch. Mains coming into residential properties are 1 1/2" MINIMUM, 2" of the street wye and reduced down at the meter. You are creating a public health issue. No where did you show a check valve nor a backflow preventer. You are creating a health risk. There are reasons plumbers need a license.

    • @celena2033
      @celena2033 3 месяца назад

      These are another 2 reasons that alert me. You.didnt reread your text for auto correct, it's volume, not pressure. And nowhere did you mention a booster pump.

    • @travisdoe4663
      @travisdoe4663 3 месяца назад

      ​@@celena2033 Our municipal service is only one inch at the meters in our town. The check valves are at the meter. So all you need is a ball valve to turn flow off to the house if you need to service it. The only thing that's required to be wrapped According to my local code are brass fittings, we use stainless steel fittings and Risers.

  • @celena2033
    @celena2033 3 месяца назад

    Hey, people, he's the reason you don't go to RUclips for utility work.

  • @brian-ek1ec
    @brian-ek1ec 3 месяца назад

    Yo ,cap dat tub spout . If you go down in dat tub ,gotta call 911 to get up.

  • @randyr316
    @randyr316 3 месяца назад

    How do i hook up outdoor temp sensor? Its not in ur vid

  • @curtdswart
    @curtdswart 3 месяца назад

    Im looking at installing one of these. How easy is it to get parts if you need them?

  • @PlumbingRight
    @PlumbingRight 3 месяца назад

    Great job. That’s a tough one

  • @ChrisTopher284765490
    @ChrisTopher284765490 3 месяца назад

    You know that guy in his working days didn’t put up with anyones BS. Guy is great with words LOL

  • @addygomez123ify
    @addygomez123ify 3 месяца назад

    nice job, beautiful install

  • @armandomadrigal9793
    @armandomadrigal9793 3 месяца назад

    At least its not a crazy waste & overflow

  • @armandomadrigal9793
    @armandomadrigal9793 3 месяца назад

    Good advice Primo, all the upcoming apprentices, pay attention

  • @armandomadrigal9793
    @armandomadrigal9793 3 месяца назад

    Primo!!, gotta love these"engineers", had a neighbor, he is an engineer for jpl out here in Cali, was trying to pull his Moen cartridge, i went and pulled that pin, he was humbled

  • @denniscordova9920
    @denniscordova9920 3 месяца назад

    You have a good rapport with your customers. 😊

  • @jeffreyhalet9632
    @jeffreyhalet9632 3 месяца назад

    One word for you… Knee pads, I’m now 60 and wish I had protected my knees better earlier on. Beautiful install by the way!!

  • @davidmerkrebs9967
    @davidmerkrebs9967 3 месяца назад

    fill the tub you hack

  • @ChrisTopher284765490
    @ChrisTopher284765490 3 месяца назад

    Nice Job Mike. Honestly how many F Bombs did you throw out off cam?

  • @mattl643
    @mattl643 3 месяца назад

    Nice job. Lets do yours next baby!!!

  • @billwendt2128
    @billwendt2128 3 месяца назад

    That was a tuff 1, good job in the BX 🕶️

  • @williamloder9194
    @williamloder9194 3 месяца назад

    Great outcome to a not so easy install. Looks good. Enjoy your videos. Plumber from Cape Cod

  • @jeffreyjohn2037
    @jeffreyjohn2037 3 месяца назад

    Regardless, the run trap is too high in relation to the condensate pan. Should be a p trap.

    • @F12255
      @F12255 3 месяца назад

      yeah those running traps are dog 💩

    • @TomHyatt-i7z
      @TomHyatt-i7z 3 месяца назад

      Hey are you ok? I’m just not sure of running trap…❤

    • @M.J.F.MECHANICALL.L.C.
      @M.J.F.MECHANICALL.L.C. 3 месяца назад

      SHOULD BE YES

  • @jeffreyhalet9632
    @jeffreyhalet9632 3 месяца назад

    How did your commercial project turn out with getting those large air handler’s through the small opening in the ceiling,I somehow missed how that one turned out.

  • @mattl643
    @mattl643 3 месяца назад

    Tighter than you sistah's chocolate starfish up in that attic. Let's do yours next baby!!!

  • @Joshuabryabt-gf6sc
    @Joshuabryabt-gf6sc 3 месяца назад

    So my old roommate had one of these and it leaked from that tube and sure as heck it was the expansion tank

  • @Z-Ack
    @Z-Ack 3 месяца назад

    5v? Your just reaching for reasons why your shit keeps shutting down.. pushing blame around.. you dont think your start cap is out of spec causing the inrush to trip? What about cabling to the compressor, it sized right? Is a fan locked up? Defrost board all happy?

    • @mediadaemon
      @mediadaemon 3 месяца назад

      I agree. Overcurrent is likely to be high head pressure due to the enclosed space.

    • @M.J.F.MECHANICALL.L.C.
      @M.J.F.MECHANICALL.L.C. 3 месяца назад

      ALL IS GOOD

  • @mediadaemon
    @mediadaemon 3 месяца назад

    On a 120/208y 3phase service, 201v is a perfectly acceptable utilization voltage for a line to line single phase appliance. Now if the condensor is not rated for 208v then its not likely right or if its a 120/240 service then its way under.

  • @EdyCokic
    @EdyCokic 4 месяца назад

    You keep this conversation so long bro very hard to watch it we need a day off when you post something to be able to watch it. And you jump from one subject to another all over the place and sometimes you talk like a therapist and life coach. Everything more than hvac/plumbing

  • @tomasalers
    @tomasalers 4 месяца назад

    Not familiar with carrier but if the reversing valves are like traditional condensers with my luck going behind other techs it’s usually the solenoid and not the valve itself. One plug one screw 5 minutes.

  • @walterbordett2023
    @walterbordett2023 5 месяцев назад

    Do you think the burnt ground and the distorted flame rod are trying to tell you that the draft is not good and things are getting hotter than they should?

    • @M.J.F.MECHANICALL.L.C.
      @M.J.F.MECHANICALL.L.C. 3 месяца назад

      THERES NO COMBUSTION TEST THAT CAN BE DONE ON THIS CONDENSING WATER HEATERS ! THATS STRAIGHT FROM AO SMITHS MOUTH !

    • @te10183
      @te10183 17 дней назад

      @@M.J.F.MECHANICALL.L.C. can do a draft test with a manometer