AmateurHour
AmateurHour
  • Видео 15
  • Просмотров 321 660
Heating Element Control Board Preview & Fail
A preview of a PCB to control heating elements for soldering, heat treating, and foundry work.
github.com/c0yote/ignis
Просмотров: 735

Видео

Kid Sized Medieval Heater Shields
Просмотров 5797 лет назад
Faced with my children's lack of sword fighting prowess, I set out to equip them properly with their own swords and shields.
Rotary and Slide Axis CNC Control Algorithm
Просмотров 8277 лет назад
I demo a quick and dirty prototype of an algorithm that could control a CNC device using a rotation and slide axis. github.com/c0yote/mountain-jackal branch: hold-the-line
AvE Portable Rotary Plasma CNC Simulator
Просмотров 1,1 тыс.7 лет назад
AvE kept me awake with dreams of magnetically chucked portable CNC cutters. I built a simulation tool to help prototype the algorithms to control it. Source: github.com/c0yote/mountain-jackal
Lathe Tool Post Teardown
Просмотров 2,5 тыс.7 лет назад
I tear down the tool post that came with the Bradford Lathe to make it easier to clean and discover how it works in the process.
3 Phase Motor Gearbox Disassembly
Просмотров 4,1 тыс.7 лет назад
I disassemble the gearbox for the Lima 3 Phase on the Bradford lathe in order to find out why it will not shift.
Checking Windings in a 9 Lead 3 Phase Motor
Просмотров 304 тыс.7 лет назад
I check the windings in the motor for my Bradford Lathe. I also provide some simplified (read right-ish) information about the electrical nature of the motor.
Storing Some Mercury
Просмотров 3,7 тыс.8 лет назад
In this episode I invite Cunningham's Law by videoing my storage of a small mercury (Hg) sample. I shouldn't have done this, and you shouldn't do this either.
Bradford Lathe 3 Phase Motor Dissassembly
Просмотров 4038 лет назад
I disassemble the Lima 3 phase motor and gear box that drives my Bradford Lathe.
Bradford Lathe Tailstock Reassembly
Просмотров 3868 лет назад
I reassemble the cleaned and painted tailstock for my Bradford lathe, and get exactly 4 seconds to breath.
Bradford Lathe Tailstock & Workshop Update
Просмотров 9458 лет назад
I get the bulk of the work done on the tailstock and give a quick shop equipment update.
Bradford Lathe Tailstock Priming
Просмотров 1248 лет назад
Quick update on the Bradford Lathe clean up with a hint of failure to plan.
Bradford Lathe Tailstock Disassembly and Cleaning
Просмотров 1,3 тыс.8 лет назад
I get the tailstock disassembled and start cleaning it.
Quick Preview of my Machines
Просмотров 2088 лет назад
I make a first pass at the bed ways on my Bradford lathe, and briefly point the camera in the direction of my K&T 2H Plain horizontal mill.
Adventures in Evaporust
Просмотров 4238 лет назад
First step in a massive clean up as I begin de-cruding the change gears for my big Bradford lathe.

Комментарии

  • @galagatron5319
    @galagatron5319 Месяц назад

    I need help. I have a 3phase. I did a conituity test between each leg. The meter beeps on all. Normal? I did a ohms check. One leg =8 another=12 another 31. I did a supco megger to each leg with one tester and the other tester to casing. It shows good. My question is simply do i have a short in this motor?

  • @davidhamilton2708
    @davidhamilton2708 Месяц назад

    Video could have been waay better if you would slow down and show your work! Better camera position

  • @ejgonyoutube
    @ejgonyoutube 3 месяца назад

    This is the video I have been looking for for years. Thank you for putting this out. It really helped me.

  • @dc6233
    @dc6233 5 месяцев назад

    Thank you for explaining this properly, took me 6 videos to find you.

  • @bobbauvian7700
    @bobbauvian7700 5 месяцев назад

    so is that mean there are 6 separate winding in there? I have heard of delta and Y connection but not star, but of course I got a lotttt to learn. thank you for your video

  • @groundrodshorts
    @groundrodshorts 5 месяцев назад

    I don't know what you're doing nowadays, but this was a great video. For what it's worth, your video is the number 1 return in Google for troubleshooting a 9 lead the phase motor. Thank you for a very concise explanation!

  • @javmar86
    @javmar86 5 месяцев назад

    Excellent video, super clearly explained!

  • @ChrisHVACguy
    @ChrisHVACguy 6 месяцев назад

    Is there a tolerance for deviation of resistance from winding to winding for the single coils?

  • @mark2020
    @mark2020 7 месяцев назад

    I was always told you need a megger to do this test correctly

  • @SashaNem
    @SashaNem 9 месяцев назад

    thank for scheme

  • @vincep1c156
    @vincep1c156 10 месяцев назад

    Great explanation!!

  • @patrickbelcastro6025
    @patrickbelcastro6025 11 месяцев назад

    That’s actually a little high for resistance on an ac 480 or 600 volt motor it should really only read 3 ohms or less most normal reading is .5 ohms

  • @shamanking5195
    @shamanking5195 11 месяцев назад

    Hi everyone. can someone tell me what could be causing high amps on two legs only ??? motor voltage = 460 motor amps rating = 283 Line 1 voltage to ground = 278 Line 2 voltage to ground = 281 line 3 voltage to ground = 280 Motor connection are secure , there is no loose connections. we Megged the motor and cables and shows over 2k megaohms . motor amps when running Phase A amps = 280 Phase B amps = 292 Phase C amps = 285 as you can see only one phases is below the name plate rating but still little bit to high. There is no enough voltage imbalance to explain the high current on the two phases . why is the high current in two phases only ??? motor was rebuilt recently. Anybody has any idea what our problem is ??? Any suggestions ???

  • @InoceNelson
    @InoceNelson Год назад

    Appreciate.thanks

  • @Rob.P974
    @Rob.P974 Год назад

    Hello there, thanks for making this video. I just wanted to comment about the inductance values you mentioned. Like you said it’s helpful if the value in Henry’s is known. If it is then the inductive reactance can be calculated by XL = 2(pi)fl, then that value can be squared off along with the resistance value and added together then square rooted. The result should give us the Impedance value.

  • @loosescrewdrew
    @loosescrewdrew Год назад

    So is low voltage 240 single phase or 240 3 phase?

    • @jhooah1
      @jhooah1 10 месяцев назад

      It's a 3 phase motor, your just changing the voltage setup, not the location of the windings, so it's manufactured as 3 Phase and cannot run single phase.(either 230 V or 460V depending on how you configure the wiring of the coils)

  • @MegaRiffraff
    @MegaRiffraff Год назад

    👍🏻

  • @robdogz01
    @robdogz01 Год назад

    Bloody awesome Video man! So clearly explained that even a dumb mechanical engine Bilder like me can understand that electronic witchcraft 😂🎉

  • @HafizurRahman-mw8bp
    @HafizurRahman-mw8bp Год назад

    I understand your theoretical side but when you measure practically how do you know which wire is which, looks very confusing did not understand your practical side.

    • @thenewkidzify
      @thenewkidzify Год назад

      Each wire has numbers on the insulation

  • @ypaulbrown
    @ypaulbrown Год назад

    thanks so much.....Paul

  • @svernwarunos546
    @svernwarunos546 Год назад

    Zombie channel

  • @aliso-pv7ll
    @aliso-pv7ll Год назад

    Being an apprentice in motor controls, I ask for low voltage, why do they want you to short 1&7,3&9 and 2&8? Why not connect to 7,9,8? Thanks for your excellent teach!

    • @michaelsaymon3705
      @michaelsaymon3705 Месяц назад

      The low voltage is wired in parallel instead of in series like the drawing 0:56

  • @jimkillen1065
    @jimkillen1065 Год назад

    I appreciate the information, it helped me to determine the correct numbers on the wires . The little metal tags were very hard to read . So i used this method and checked the condition of the windings . . What a learning experience especially trying to get the motor to run properly with a phase convertor. I going to buy a vfd and use it on the bridge port mill. Thanks

    • @v4lhulme
      @v4lhulme 10 месяцев назад

      Just remember to check rotation direction. If it's spinning backwards just swap L1 with L2 OR L2 with L3 OR L3 with L1. Basically just swap any 2 and it will change direction.

    • @dc6233
      @dc6233 5 месяцев назад

      HA! My Bridgeport just died and IDK if it's the motor or the static convertor; that's why I'm here. Oh well, I got 20 years out of it and only paid 100$ for it, I'm doing good no matter what the issue is...

  • @mavutoshaba9447
    @mavutoshaba9447 Год назад

    I didn't see clear the way you are testing What can I do to get it clear

  • @bigdaddy4975
    @bigdaddy4975 Год назад

    Why didn’t you get a megger I just got the Klein and this thing is great.

  • @kingssing
    @kingssing 2 года назад

    very well explained.

  • @ALIDIY007
    @ALIDIY007 2 года назад

    If the wires is not marked how to determine which wire is 1-4 3-6 etc??

  • @Алюминаткобальта
    @Алюминаткобальта 2 года назад

    Вау

  • @taylorsellers5244
    @taylorsellers5244 2 года назад

    Love the step by step instructions on how to check the windings. It really helps make sense of all the "book learning" I've done

  • @jeffgerst3619
    @jeffgerst3619 2 года назад

    Good video. All coils are used irregardless of the supply Voltage. High voltage uses the +3 method for connecting the leads together and low voltage connects the windings in parallel with each lead connected to 1 and 7, 2 and 8 and 3 and 9 with 4-5-6 connected together just like 10-11-12 are from the factory. Hig voltage connects windings in series.

  • @younesmadride978
    @younesmadride978 2 года назад

    thanks very good. i am from Algeria. i am glad to see you . we'll I Will ask you about. when we make start high power . star low power. and when make delta high power .and dalta low power . and thank you very much.

  • @mikeadler434
    @mikeadler434 2 года назад

    👍👍

  • @twistedsno6734
    @twistedsno6734 2 года назад

    Helped me on my test

  • @PULSARIONequinox1
    @PULSARIONequinox1 2 года назад

    Wouldn't you have continuity between leads 1,2,3??

  • @davidhamilton2708
    @davidhamilton2708 2 года назад

    Great video with explanation, thank you for drawing the diagram FIRST!!!👌🏿

  • @zachariahmiddleton5256
    @zachariahmiddleton5256 2 года назад

    You saved me from spending like $800 on a new motor. Thank you!

  • @trueuno1
    @trueuno1 3 года назад

    At school they have us megg between 1 and 4. Doesn't that seem wrong?

  • @HumbleBrownWarrior
    @HumbleBrownWarrior 3 года назад

    You need to use a megger for a AC Gen.

  • @elcompavergolia9986
    @elcompavergolia9986 3 года назад

    What of the leads had no numbers????? Please do a video on that 🙏

    • @cfgman1
      @cfgman1 6 месяцев назад

      That indeed would an interesting video.

  • @gbrecycle8347
    @gbrecycle8347 3 года назад

    how to convert it in 1 phase?

  • @JoseAntonio-tt2mb
    @JoseAntonio-tt2mb 3 года назад

    Good afternoon , is it motor baldor?

  • @سعود-ق8غ7ث
    @سعود-ق8غ7ث 3 года назад

    How to convert silver mercury to red method

  • @marwanmoussif1814
    @marwanmoussif1814 3 года назад

    Hello, how are you? I am a young man. I am 24 years old. I work in the field of repairing electric motors, Bobbinage. I would like to work with you. I have experience and fast work. This is my number 49145985. Thank you. ملاحظا

  • @simpliciocamirino2271
    @simpliciocamirino2271 3 года назад

    Thank you for that sharing sir.

  • @austineswann1
    @austineswann1 3 года назад

    Your video just taught me that the hvac tech charged me for a new motor when the motor I had was perfectly fine. Then he tried to leave with the "bad" motor. The tech was trying to steal a perfectly good $800 motor.

    • @ChevyORwalk
      @ChevyORwalk 3 года назад

      Is it running now?

    • @v4lhulme
      @v4lhulme 10 месяцев назад

      One thing to remember, the motor also has bearings at the front and back of it that can go bad and seize, the windings may be good but the bearings go bad. Lol

    • @ScottDavis-d2g
      @ScottDavis-d2g 6 месяцев назад

      I had an instructor and AC repair man that pick up ""BAD AC compressor's and motor's off the side of the road". Take them home and test them, the majority were good.

    • @dc6233
      @dc6233 5 месяцев назад

      Beware, lousy companies do this often. A "friend" sold a customer an entire HVAC system when his old one was only 3 years old. He just wanted money for drugs and he's where he belongs now, in jail.

    • @Josh-px6xb
      @Josh-px6xb 3 месяца назад

      @@ScottDavis-d2gif they are not shorted to ground you won’t know for sure unless power is applied. It could be locked up mechanically but electrically it’s good

  • @petitladiop5961
    @petitladiop5961 3 года назад

    I'm interested please help me

  • @goldfish5606
    @goldfish5606 3 года назад

    really good video testing using a multimeter. Sadly i was hoping for a video as good as this video was made using a digital insulation resistance tester

  • @albertchen6816
    @albertchen6816 3 года назад

    Aren't you supposed to megger the insulation?

  • @brwndogg831
    @brwndogg831 3 года назад

    Very clear and instructive video . Thank you so much !

  • @mattsmith6828
    @mattsmith6828 4 года назад

    The Fluke 87-V has no rivals.