Switch Gear & Automation
Оман
Добавлен 8 янв 2014
Learn about electrical and electronics switch gear components, PLC, VFD Also know about function and use.
Please subscribe the channel...
Thanks for your support....
Please subscribe the channel...
Thanks for your support....
SOFT STARTER ATS480 COMMISSIONING VIDEO / SCHNEIDER/CURRENT BUSINESS SOLUTIONS LLC / OMAN
Site installation videos.
how to install soft starters at site.
pump stations
#automation #schneider #oman #electronics #electricalinstallation
how to install soft starters at site.
pump stations
#automation #schneider #oman #electronics #electricalinstallation
Просмотров: 207
Видео
HMI configuration - Date and time / basics / SCHNEIDER HMI...
Просмотров 202Месяц назад
Schneider Ecostruxure operator terminal HMI configuration. #hmi #schneider #oman #plc #automation
How to control MOVE BLOCK with Digital Input? SCHNEIDER- M172 PLC
Просмотров 3304 месяца назад
IN THIS VIDEO WE HAVE SHOWN HOW TO CONTROL #move BLOCK WITH DIGITAL INPUT #m172 #schneiderplc #automationtesting #automation #HVAC #HMI #VARIABLES
Schneider HMI / Basics/Schneider PLC M172/HMIST6
Просмотров 1505 месяцев назад
HMI BASICS, SCHNEIDER PLC & HMI, M172, HMIST6
How to use impulse relay and cyclic timer in PLC for duty standby logic/ FBD/Schneider PLC
Просмотров 3668 месяцев назад
#zelio #schneider #pumpcontrol #dutystandby #plclogic #plcprogramming #siemens #sennapparajan #currentbusinesssolutions #oman #dubal #africa
PLC programming -Basic configuration of analog inputs /inbuilt with PLC and extension module..
Просмотров 2369 месяцев назад
This video we have explained what is the different between onboard analog input and extension analog input. #schneider #zelioplc
Oman Mazoon college students IV to Alkhoory Oman / Thank you for you Opportunity / Industrial visit
Просмотров 16511 месяцев назад
#students #mazooncollege #muscatstudents #iv #industrialvisit #alkhooryoman #schneider #sennspparajan #schneiderplc
What are PNP/NPN transistors? How its working...
Просмотров 218Год назад
A bipolar junction transistor is a three-terminal semiconductor device that consists of two p-n junctions which are able to amplify or magnify a signal. It is a current controlled device. The three terminals of the BJT are the base, the collector, and the emitter. A signal of a small amplitude applied to the base is available in the amplified form at the collector of the transistor. #bjt #bipol...
How Transistors are Receiving /Sending Inputs and outputs in PLC/VFD ? What is Optocoupler?
Просмотров 234Год назад
In PLC input card, how its working with both polarity with NPN and PNP type transistor? #optocoupler #npn #pnp #transistor #sinking #sourcing #plcinput
How to write PID control logic for SCHNEIDER PLC-M221/ Variables For HMI..
Просмотров 1,2 тыс.Год назад
#m221 #schneiderplc #pidcontroller #automation #hmi #memoryaddress
Two speed Motor starters working, testing & commissioning at site /HVAC
Просмотров 667Год назад
#doublespeed #jetfans #plcpanel #hvac #gicplc #basementventilation #dualspeedstarter
How to Write Analog output Value for M221 Schneider PLC.....
Просмотров 1,4 тыс.Год назад
#vfdspeedcontrol #m221plc #schneiderplc #automation
PLC control panel for Car park ventilation with CO Sensors / HVAC
Просмотров 1 тыс.Год назад
#hvaccontrolpanel #plccontrolpanel #plc #automation #m172plc #schneiderplc #carpark #ventilation
ELECTRICAL CONTACTORS - Some unknown information / how it is working / NO/NC/ Coil supply...
Просмотров 375Год назад
A contactor is an electrical device that is widely used for switching circuits on and off. As such, electrical contactors form a subcategory of electromagnetic switches known as relays. A relay is an electrically operated switching device that uses an electromagnetic coil to open and close a set of contacts. This action results in a circuit powering either on or off (establishing or interruptin...
Timing operation with M221 PLC-How to use RTC - Real time clock / Eco Struxure Machine expert..
Просмотров 1,4 тыс.Год назад
#m172 #mchineexpert #automation #schneiderplc #tm221
VFD Speed control using ANALOG OUTPUT /SCHNEIDER M172 PLC for water pump....
Просмотров 1,3 тыс.Год назад
VFD Speed control using ANALOG OUTPUT /SCHNEIDER M172 PLC for water pump....
Basic electrical designing - DB, SMDB, ESMDB, MDB FOR 8 floor building ....Explained.....
Просмотров 1 тыс.Год назад
Basic electrical designing - DB, SMDB, ESMDB, MDB FOR 8 floor building ....Explained.....
Understanding of VFD bypass starter and SOFTSTARTER bypass starter ….Explained...
Просмотров 253Год назад
Understanding of VFD bypass starter and SOFTSTARTER bypass starter ….Explained...
Why VFD need Bypass starter ? Explained with Circuit /Bypass star delta
Просмотров 1,1 тыс.Год назад
Why VFD need Bypass starter ? Explained with Circuit /Bypass star delta
HMI - Human machine interface - Operation explained with PLC...
Просмотров 1 тыс.Год назад
HMI - Human machine interface - Operation explained with PLC...
M172 /SCHNEIDER PLC - BASIC PROGRAMMING TUTORIAL / TM172...
Просмотров 1,4 тыс.Год назад
M172 /SCHNEIDER PLC - BASIC PROGRAMMING TUTORIAL / TM172...
SCHNEIDER M172 PLC TUTORIAL - HOW TO USE ANALOG INPUT AS A DIGITAL INPUT/ECO STRUXURE HVAC
Просмотров 1,6 тыс.Год назад
SCHNEIDER M172 PLC TUTORIAL - HOW TO USE ANALOG INPUT AS A DIGITAL INPUT/ECO STRUXURE HVAC
The technical difference between pressure transducer & pressure switch Explained....
Просмотров 364Год назад
The technical difference between pressure transducer & pressure switch Explained....
SIEMENS LOGO - EASY TIPS FOR PROGRAMMING IN FUNCTION BLOCK DIAGRAM..
Просмотров 559Год назад
SIEMENS LOGO - EASY TIPS FOR PROGRAMMING IN FUNCTION BLOCK DIAGRAM..
Schneider-Ecostruxure M172 - Machine Expert PLC - How to do simulation /Schneider
Просмотров 1,1 тыс.Год назад
Schneider-Ecostruxure M172 - Machine Expert PLC - How to do simulation /Schneider
Schneider-EcoStruxure M172 - Expansion module configuration...
Просмотров 1,3 тыс.Год назад
Schneider-EcoStruxure M172 - Expansion module configuration...
EcoStruxure M172 -Module selection & Basic programming / IO mapping / SCHNEIDER/MACHINE EXPERT
Просмотров 4,5 тыс.Год назад
EcoStruxure M172 -Module selection & Basic programming / IO mapping / SCHNEIDER/MACHINE EXPERT
How BMS works (Building Management System ).Simply Explained...
Просмотров 3,9 тыс.Год назад
How BMS works (Building Management System ).Simply Explained...
what is PID CONTROLLER / FUNCTION in automation? Explained with example & program..
Просмотров 501Год назад
what is PID CONTROLLER / FUNCTION in automation? Explained with example & program..
what is True Off Delay timer? How its works? Explained.....
Просмотров 1,3 тыс.Год назад
what is True Off Delay timer? How its works? Explained.....
Sir how to schinider zelio communicate with vfd by modbus
hi... you need to add communication module with zelio PLC. also need to check if its supporting for MODBUS. will let you know.
@sennapparajan.p sir can you make detail in video???
Sir please make video Simens logo and vfd control through modbus communication
Sir please make video zelio modbus communication
Hi brother I have 4 pumps set up with one high pressure output. I am using a 4-20ma transducer. I am using 4 outputs from the common HP output of pumps. If I use one output my pump should give me 10 ma. When second output starts on the common output second pump starts maintaining 10 ma and so on. If any output is turned off my one pump should shut down and same for all the pumps. Can I do it with Logo . Please help me. Thanks in advance.
hi.. really i couldn't understand what u want exactly.. please explain clearly.
@@sennapparajan.p Hi, Thank you very much for prompt reply, I have 4 pumps. HP is monitored with one transducer. I want to have a set pressure all the time. When I use one HP output, One pump starts. If I use two HP outputs First pump pressure goes down than the set pressure, so second pump starts to make up the set pressure and so on with all the four pumps. When I shut one HP output (When all four HP outputs are active and all four pumps are on) one pump shuts down and same way for all the four. Hope it helps.
Is it ok to change the Ir while MCCB is on ?
technically its ok. but safety wise not gud.
Hello Sir. I need your help to program 4 pumps with transducer, how do I contact you.
Hi, can you do ST programming M173?
My contactor is tripping when mcb on and golink power regulator light blinking so sir can u tell me what is actual problem coming... mcb is ok and contactor is also ok...
Hi a major part went above my head. You must be expert and I appreciate. In your logic just starts and stops, now a days pump motors are controlled by VFD and it’s with PID command. Can you advise me with it?
Totally wrong and misleading
any reason?
@@sennapparajan.p because the attributes you specifying for one also belong to the other one, and vise versa. You are NOT addressing the differences.
super ,
Sir please video in Hindi
useful one...
I didn't watch your video because I know it is for beginners but I will ask you a question maybe you have the answer for it for driving an air blower motor What are the critical parameters that I should give them more attention to to prevent the VFD from faulting with overload or over voltage . The second question is what parameters I should adjust to move a heavy load machine in low speed with direct motor no gear box just a synchronous belt. You can choose any brand but I prefer Mitsubishi or Fuji just Give me the parameters number.thanks for sharing your knowledge with us
hi bro thank you for your feedback. in any VFD brand there are selective model VFD for heavy machinery and simple machine. we need to select accordingly. also some of VFD has 2 ratings like... the same VFD 18.5kw (HD - HEAVY DUTY) and 22kw ND-NORMAL DUTY. so we can select the same. and in parameter in control mode option Select sensor less vector control for heavy motor with gear box /direct best driven. if you run normal machine like ex fan or AHU motor select V/F control (voltage frequency control) i hope u understand if you need more details please let me know if u want to know exact parameter number please let me know the VFD make and model.
@@sennapparajan.p thanks I will try this but I am not sure . because during my career where I had air blowers I get VFD overload fault sometimes every 2 weeks sometimes after 2 or 3 Months all this from different brands and different machines
if logo possible to change the analog output with count value. for example, when counter is 1, then Ao=100. when counter is 2, then Ao=250. when counter is 3, Ao=800
yes its possible
siemens 6ed1052-1cc08-0ba2 model does not seem to give out digital but 24VDC output?
Do you do a course?
OKEH How many okay in this video? gift away waiting for u
Thank you for unlocking a apart of my brain lol.
Is it get wiring diagram,
Hindi
Not a good explanation... Fully confused now
സാംസ്കാരിക നഗരം തൃശ്ശൂർ തന്നെ ആണ് 😂
How to do program delta T in logo plc for heating
please share your number ,we require your consultancy and execution for large project in pune
Please send me your number
Thank you
3 phase moter ka 3 time multiply karna padega mathlab startinge current 3 time 4 time jadha chaltha he Or single phase 1.5 multiple karna padega 15 amps hoga tho 15×1.5. 22 ampere
Vacon vfd pressure transducer parameter setting tell me bro plzz
Hello bro ji kya muje PLC ki childwater on and off hr dx kntrol drawing pic mil gaye gi bro ji
But here n u.a.e mostly kwh meter s connected with Smdb insted of mdb which u mention here
🎉
Thanks man
English la purila mudinja tamil la sollunga appo than yengalukum doubt varum illaina unsubscribe panniduven
bro...unga doubt sollung will do u video for u iin tamil..
thank for the above video. But is it possible to do manually on the PLC.
Bro Add Trip logic
Make a same logic with trip functions for delta PLC
Bro same logic make in for delta PLC
i don have software and i don't use delta PLC... THANK YOU..
@@sennapparajan.p bro free available in Delta website and just make a simulation demonstration
@@sah_shrawan Ok..will try..
your video is more irritating to viewers because always you are telling ok ok. what is this ?
sorry pa.... will try to improve.. thank you for your feedback...
👎
Dear Sir, Thank you for uploading the valuable video for us. We would greatly appreciate it if you could also upload the control wiring project. Additionally, could you please provide me with your contact number? I would like to discuss some business details further. Thank you! Best regards,
Hi Thanks for your knowledge sharing.. can you please make hand sketch flow chart will be helpful and what level carbon monoxide Wil triggering if we have any specific range pls share details
Hi.. the level is based on our setting in PLC. we can set any level for triggering by PLC programming. example.. 0-20 PPM level is normal if CO level goes above 20PPm we can start the FAN and extract it. hope u got an idea.
Price amd contact details 8:33❤
Link for more explanation?
Is it possible to do based on lead lag run time changeover
I have an enquiry
Yes please…
🎉🎉🎉🎉🎉🎉🎉
Hi I want to set the set temp in HMI KTP 700 which shall be variable and with respect to Analog input in logo plc the out put shall on/off function shall happen is it possible from logo ?
I use 1.5/100 kw brake but the output go in to PLC sometime cause of fault. How ca I solve it ?
Nice explanation okay
Bro❤