ABB 'Slimline' Fuseswitch Installation Video
A supplier partner video showing the ease of fitment at minimal time for ABB type 'Slimline' BS88 fuse switches. Ranging from 63A to 630A 3P & 4P within our bespoke switchgear cubicles a high density of incoming / outgoing circuits can be provided. For more information contact us on enquiry@reespowersystems.com
Просмотров: 794
Видео
Descriptive ABB 'Slimline' fuseswitch overview
Просмотров 57311 лет назад
A supplier partner video showing the 'Slimline' 3P and 4P fuseswitch and isolator, 'modular' LV distribution system. Supplied by 'Rees' into London Underground in many stations plus other clients its high density stacking and low heat rise characteristics are very favourable. For more details e-mail us at enquiry@reespowersystems.com
Descriptive ABB 'Fastline' LV distribution overview
Просмотров 1,1 тыс.11 лет назад
A supplier partner video showing an innovative isolator, fuseswitch, MCCB with metering, 'modular' LV distribution system up to 2500A. Very flexible and can be installed into exterior IP65 feeder pillars or internal LV Switchboards. For more details e-mail us at enquiry@reespowersystems.com
Options for Circuit Protection MCCB or Fuse
Просмотров 22 тыс.11 лет назад
A very interesting supplier partner video showing numerous short circuit performance tests on a range of MCCB's against fuse cartridges. Often these type of feeder circuits are where LV Switchboard faults occur - while both device types have advanatages which one is inherently safer ? - you decide. 'Rees' techncial advice for your application is available from enquiry@reespowersystems.com
Normal / Standby Mechanically Interlocked ACB's
Просмотров 278 тыс.11 лет назад
A supplier partner video showing fitment of a 'bowden'' cable mechanical interlock between two air circuit breakers. Typically used in a normal mains and standby generator arrangement. Any1 from 2 devices can only be CLOSED. Prevent paralleling of dis-similar power sources. 'Rees' can supply new units or re-calibrate / check your existing interlocks and ACB's Contact us at enquiry@reespowersyst...
Induced and Propogated Busbar Phase Arc Fault
Просмотров 3,5 тыс.11 лет назад
'Rees' commissioned this test station video to demonstrate the energy dervied from a phase to phase arc fault. Upon the fault occuring the supply energy was deliberately not isolated and hence a 'prolonged' arc flash resulted. A 1mm fuse wire between two copper conductors was all that was needed to instigate this fault ! 'Rees' busbar systems are designed and tested to withstand faults of much ...
Form 4 Type 5 - High Integrity MCCB or Fuseswitch Phase Terminations
Просмотров 47311 лет назад
A 'Rees' developed and manufactured MCCB or fuseswitch field cable phase and neutral high integrity seperation application. Provides easy 'disconnect' access to lug terminations - guaranteed phase seperation ! Contact us on enquiry@reespowersystems.com
Form 4 Type 5 - High Integrity Fuseswitch Part Assembly
Просмотров 26211 лет назад
A 'Rees' CAD developed and CAM manufactured 'Slimline' fuseswitch application Contact us on enquiry@reespowersystems.com
ISO Containerised 1500 kVA Diesel Generator Set
Просмотров 84111 лет назад
80dBA @ 1M - Diesel standby generator within RPS designed acoustic enclosure. Part of a new LV Switchgear mains/standby system designed, manufactured and installed by ourselves Contact us on enquiry@reespowersystems.com
nice
Why not used MN accesories ACB
Hi Sir, it was very good it helped me alot ..Could you help on how to settle a situation when rack in the ACB there is no contact to the breaker ..
👨🔧🏃♂️🤺💤💣
Great
HỘI KỸ SƯ ĐIỆN VIỆT NAM channel specializing in sharing knowledge about electricity wants to exchange and make friends. Everyone can go through our channel and give us advice for us to improve. We will be extremely grateful for this.............///
Our have same Lt omeage acb and standadby mechanical lock with lock key pls explain the purpose
can you help with l&t breaker
hii
In auto acb isnot closing but in manual mode it is closing? Why not auto?what may be the problem?can u tell me sir
changeover of two supply by bus cupler acb
sir we have 2500amp 3 pole ACB but every 7/ 6/8 hours after tripping we disconnected all output supply but again tripping please tell me sir why tripping and what we have to do
It means protection mode is active in your acb. ...it may be thermal magnetic or any malfunction data occur on acb...correct all data if probolam is not fixed make bypass.
how about the electrical interlocking?
Interesting! I think you just made the smoke monster from "Lost"
nice it helps me about the curiosity in my mind. . .thank you very much
please to show rack out&rack in
please to show rack out&rack in
thank you
ABB SlimLine XR product solved the problems : new.abb.com/low-voltage/products/fusegear/slimline-xr
why we charge air circuit breaker or VCB...any one tell me explane and solve my issue.
Once discharged, the spring has to be wound again, means we need to charge again. Wounding spring is charging.
Pandarinath Wagdalle
Vcb acb direffince
Air circuit breaker and vacuum circuit breaker
@@pandarinathwagdalle4416 while closing and opening contacts ..arc is produced...if arc is reduced by air...acb..if arc is reduced in vacuum it is vcb
halloooo
asslamualeikum
asslamualeikum
asslamualeikum
I wonder how these interlocks work...
asslamualeikum