IowaFireControl
IowaFireControl
  • Видео 27
  • Просмотров 154 022
Vehicle Fire Suppression Hydro Test Points
Noah Carspecken of Iowa Fire Control talks about hydro testing of vehicle fire suppression systems and what is done during a typical hydro. Iowa Fire Control services vehicle fire suppression systems in Des Moines, Ames, Fort Dodge, Burlington, Mason City, Sioux City, Northern Iowa, Minnesota, Nebraska, Illinois, and surrounding communities.
Просмотров: 126

Видео

Main problems found after inspections of vehicle fire suppression systems
Просмотров 926 лет назад
Noah Carspecken of Iowa Fire Control talks about Vehicle Fire Suppression Inspection and the main problems that are found after an inspection is done. Iowa Fire Control services Des Moines, Fort Dodge, Mason City, Sioux City, Spencer, Ames, Burlington, Waterloo, Cedar Falls, and all of Iowa.
Reasons why wet Chemical Fire Suppression systems accidentally dump or go off
Просмотров 5546 лет назад
Noah Carspecken of Iowa Fire Control talks about reasons wet chemical fire suppression systems have accidental trips or releases. He covers fire suppression systems such as Ansul, Badger, Range Gaurd, Kidde, Amerex, Pyrochem, Pirhana, Buckeye and Protex. Iowa Fire Control has offices in Des Moines, Mason City, Fort Dodge, Ames, Burlington, and Sioux City to take care of fire suppression and any...
Clean Agent Fire Suppression Inspections with Noah Carspecken Iowa Fire Control Des Moines Iowa
Просмотров 2746 лет назад
Noah Carspecken of Iowa Fire Control in Central Iowa with locations in Des Moines, Fort Dodge, Mason City, Burlington, Ames, and Sioux City talks clean agent fire suppression. He talks about inspections of fire suppression systems such as FM-200, Novec 1230, Ecaro 25, HFC 227, CO2, Fike, Sinorix, UTC, Kidde, Ansul, and others.
Wet Chemical Fire Suppression System Hydro Testing Process Explained
Просмотров 1,3 тыс.6 лет назад
Noah Carspecken of Iowa Fire Control explains the process of hydro testing a wet chemical fire suppression system.
Fire Extinguisher Hazard Analysis Explained
Просмотров 2666 лет назад
Noah Carspecken of Iowa Fire Control explains how a fire extinguisher technician does a hazard analysis when coming on site for new fire extinguisher placement and installation and existing annual inspection of fire extinguishers.
Choosing a Vehicle Fire Suppression Installation Company
Просмотров 276 лет назад
Noah Carspecken of Iowa Fire Control speaks about the difference between having an OEM install a vehicle fire suppression system or a local contractor. Focuses on the benefits of having a local contractor install your system and how to choose the right contractor.
Wet Chemical Fire Suppression Hazard Analysis
Просмотров 3056 лет назад
Noah Carspecken with Iowa Fire Control speaks about hazard analysis before service or installation on a wet chemical fire suppression system. His information is from experience in testing and inspected fire suppression systems and from his knowledge of NFPA 17A.
Vehicle Fire Suppression installations service contracts and inspections
Просмотров 416 лет назад
Vehicle Fire Suppression systems are discussed by Noah Carspecken with Iowa Fire Control. Suppression systems are always in need of continual service and maintenance and periodic recharge. What happens when a vehicle fire suppression system discharges in the middle of the evening?
Wet Chemical Fire Suppression Inspection Process
Просмотров 5116 лет назад
Noah Carspecken of Iowa Fire Control in Des Moines Iowa talks about the different fire suppression inspection points. Wet chemical fire suppression systems are the main defense against a major fire in your kitchen. Maintaining your fire suppression systems is of the highest importance. Make sure your systems are maintained by a fire suppression professional.
Vehicle Fire Suppression Semi Annual Maintenance Explanation
Просмотров 1676 лет назад
Noah Carspecken of Iowa Fire Control speaks about the semi annual inspections and maintenance on Vehicle Fire Suppression Systems.
Vehicle Fire Suppression Systems Blow Off Caps
Просмотров 1507 лет назад
Noah Carspecken with Iowa Fire Control speaks about Vehicle Fire Suppression system components and vehicle fire suppression system inspections.
Vehicle Fire Suppression Systems Pneumatic Actuator
Просмотров 1737 лет назад
Noah Carspecken with Iowa Fire Control talks about Vehicle Fire Suppression systems and inspection points on the systems. The systems are prevalent in mine site application mainly and the pneumatic systems on Ansul Vehicle Fire Suppression are focused on.
Vehicle Fire Suppression Systems Manual Actuators
Просмотров 3177 лет назад
Noah Carspecken with Iowa Fire Control speaks about Vehicle Fire Suppression System components. The difference between Ansul vehicle fire suppression pneumatic and electric actuators is discussed. Inspection differences are shown as well.
Cartridge Operated Versus Stored Pressure from Iowa Fire Control
Просмотров 8 тыс.7 лет назад
Noah Carspecken of Iowa Fire Control speaks about cartridge operated fire extinguishers and fire suppression in comparison to stored pressure type fire extinguishers. Video is meant for fire equipment distributors, end users, AHJ, Fire Marshalls, etc.
Vehicle Fire Suppression Inspection Points from Iowa Fire Control
Просмотров 1277 лет назад
Vehicle Fire Suppression Inspection Points from Iowa Fire Control
Fire Extinguisher Annual Inspection Video
Просмотров 1,1 тыс.7 лет назад
Fire Extinguisher Annual Inspection Video
Hydrostatic Testing of Stored Pressure Fire Extinguisher Final
Просмотров 39 тыс.7 лет назад
Hydrostatic Testing of Stored Pressure Fire Extinguisher Final
Rooftop grease containment
Просмотров 2 тыс.12 лет назад
Rooftop grease containment
Fan Hinge Kits; Range Hood, Kitchen Exhaust Hood, Accessories
Просмотров 2,9 тыс.12 лет назад
Fan Hinge Kits; Range Hood, Kitchen Exhaust Hood, Accessories
Kitchen Exhaust Components
Просмотров 60 тыс.12 лет назад
Kitchen Exhaust Components
Grease Lock for Kitchen Exhaust Cleaning: The End of Hood Cleaning
Просмотров 14 тыс.12 лет назад
Grease Lock for Kitchen Exhaust Cleaning: The End of Hood Cleaning
Exhaust Fan Access Ports
Просмотров 1,1 тыс.12 лет назад
Exhaust Fan Access Ports
Fire Classifications
Просмотров 79513 лет назад
Fire Classifications
CO2 & Halotron
Просмотров 12 тыс.13 лет назад
CO2 & Halotron
Class K Restaurant Extinguisher
Просмотров 2,8 тыс.13 лет назад
Class K Restaurant Extinguisher
Fire Extinguisher Ratings
Просмотров 6 тыс.13 лет назад
Fire Extinguisher Ratings

Комментарии

  • @daveynorman4979
    @daveynorman4979 Месяц назад

    why when I do a 6yr maintenance sometimes it’s leaks out even when I change the o ring need help?

  • @VictorMiller-q8q
    @VictorMiller-q8q 7 месяцев назад

    great video

  • @yoz1967
    @yoz1967 10 месяцев назад

    When a unit calls for 585 test pressure but the working gauge sets on 586 or 588 what gets recorded on the data sheet? What gets punched out on the sticker label for the hydro reading?

  • @robcampbell1056
    @robcampbell1056 Год назад

    I own a Fire Prevention Company and have been testing Fire Extinguishers for 30 years. This is exactly what a testing room looks like. Powder everywhere. There are many other videos out there, usually by manufactures of equipment that show a perfectly clean shiny room with no yellow powder anywhere... Yeah, right... The only thing this video didn't show you is the holes in the walls because you get mad when an extinguisher goes off and the technician throw the thing against the wall. and then rights NFG on it.

    • @oldmech619
      @oldmech619 Год назад

      I have a bunch of old fire extinguishers. A couple were partly discharged. What should I do with them. 5pound

    • @stevecraighead4816
      @stevecraighead4816 10 месяцев назад

      My shop looks nothing like that and I’ve been doing fire extinguishers for over 20 years myself. I also have SOP’s in place to control the powder versus what I see in this shop. Dumping chemical into an open bucket instead of having a bucket lid on the top with a hole cutting it so just the mouth of the extinguisher cylinder fits in it. That cylinder vacuum thing from Getz is a piece of garbage. I came up with something my first week in fire protection that I’ve been using ever since 1995. Also, I don’t DOT test Ansul extinguishers because they’re not DOT cylinders

  • @sfdiscovery
    @sfdiscovery Год назад

    What is the difference bw ecology unit vs kitchen hoods

  • @carlosvelazquez2191
    @carlosvelazquez2191 Год назад

    And the most important..I can recharge in the fire scene area.

  • @brilliant13675
    @brilliant13675 Год назад

    So.... What brands are in the video and what were they rated? Lmao

  • @ashleywhatsittoya9345
    @ashleywhatsittoya9345 Год назад

    Didn’t show drying process

  • @aliwcarterelamparo9410
    @aliwcarterelamparo9410 2 года назад

    Does the piping/nozzle need also hydrotest, or only the cartridge and Wet-Chemical cylinder?

  • @StevenTYates
    @StevenTYates 2 года назад

    2:50 do not exceed 30 seconds during pressure testing. Its not 1 minute

    • @gmc1966
      @gmc1966 2 года назад

      According to NFPA 10 standard, you are required to hold the pressure for one minute

  • @Hollowayshouse1026
    @Hollowayshouse1026 2 года назад

    Cartridge operated is much more expensive

  • @madaneoulix1312
    @madaneoulix1312 2 года назад

    I work for big company that does this.. we always pressure to the end of the green just before so people can get as much use out of it as possible during an emergency.. and the hydrostatic testing in my state's only 30 seconds I find that interesting you guys have to do it for a minute

  • @faridulislamsardar
    @faridulislamsardar 2 года назад

    I am tacnichian of fire extinguisher I need a job

  • @samuelarney9224
    @samuelarney9224 2 года назад

    I've always wanted to do this for a living just don't know how

  • @thomaspalmaffy9112
    @thomaspalmaffy9112 2 года назад

    Appreciate it. Thanks

  • @johntabacek581
    @johntabacek581 2 года назад

    Very informative video. The new, innovative technology of the Rusoh Eliminator, which is non-pressurized until ready for use, does not require a 6 yr teardown. ruclips.net/video/Zyfrz-QC2tA/видео.html

  • @jaxrules2892
    @jaxrules2892 3 года назад

    how old is this

  • @mtbcaravan4632
    @mtbcaravan4632 3 года назад

    😂😂😂

  • @johntabacek581
    @johntabacek581 3 года назад

    Do you know that when you mix powders from other Fire Extinguisher Manufactures in that hoper, it's a Code violation, Manufactures Warranty and UL Listing has been voided. The Extinguishers will not operate as designed and is a danger to public safety. Check out the 1st complete redesign of the Fire Extinguisher in nearly 70 Years! @t

  • @joshuahandy2002
    @joshuahandy2002 3 года назад

    You are using the wrong Lube for Ansul Sentry Dielectric silicone compound, I like your low pressure hydro machine.

  • @GatheringSticks
    @GatheringSticks 3 года назад

    you have 110 problems but not one of them is hair loss. Keep her thick buddy.

  • @jamiemitchell8746
    @jamiemitchell8746 3 года назад

    Great video thanks for posting. Recently started my own business here in Canada Looking for guidance on forms for a 6 and 12 year maintenance

    • @talhamian
      @talhamian 2 года назад

      im in Canada as well and i started this business last year and ive been doing so well. very niche business

    • @talhamian
      @talhamian 2 года назад

      @@ricardovega6252 you just need insurance. I don't think you need a business license

  • @misterindependent7994
    @misterindependent7994 3 года назад

    Is there a static pressure limit in the hood that would indicate time to change filters? I'm assuming .5in/wc would be the max.

  • @user-wq4qm8nj2u
    @user-wq4qm8nj2u 3 года назад

    He didn't replace the o ring and there's a lot of wasted movement in this demonstration. Is this how you normally do your tear downs ?

  • @prlee1
    @prlee1 3 года назад

    bravo colleague

  • @bigtodd6609
    @bigtodd6609 3 года назад

    In Australia they don't put a verification of service collar on them after testing - They only stamp the bottle. Makes you wonder if they're Hydrostatically testing them properly.

    • @Krajorg
      @Krajorg 2 года назад

      I doubt it the majority of people probably just stamp it without doing anything that’s why we use service collars because you have to take the head off in order to put it on

    • @ghermansizer
      @ghermansizer Год назад

      They stamp the co2 bottle with the date and their R.i.n. #.

  • @firealarm3915
    @firealarm3915 3 года назад

    What is the purpose of doing a hydrostatic test when you could just replace the extinguisher completely for a fraction of the cost?

    • @user-wq4qm8nj2u
      @user-wq4qm8nj2u 3 года назад

      A hydrostatic test is a 1/4 of the price of most new extinguishers unless your buying a junk extinguisher. Secondly it's better for the environment to reuse a perfectly acceptable extinguisher.

    • @firealarm3915
      @firealarm3915 3 года назад

      @@user-wq4qm8nj2u Ah, thanks!

    • @schnoodle3
      @schnoodle3 3 года назад

      @@user-wq4qm8nj2u I wish that were the case for CO2 extinguishers.

  • @99SVTBolt
    @99SVTBolt 4 года назад

    Which is better to have in a car?

  • @chrishuston1451
    @chrishuston1451 4 года назад

    looking for a pyro chem red large tank with the silver tag and newer date code. psmc@hotmail.com

  • @williamwiwczaroski3598
    @williamwiwczaroski3598 4 года назад

    My questions to this video... Per NFPA 10 IS IT NOT MANDATORY TO CHANGE ALL PARTS EVERY 6 YEARS? NEW VALVE STEM NEW ORING I mean technically by the video the proper services were not completed due to that nature. If going to show on youtube shouldn't you be 100%?

  • @royaltransport481
    @royaltransport481 4 года назад

    hi noah thanks for all these videos i live in Va MD Dc metro area and i have a hood cleaning company. i want to add a business to it, in which majorly i will be doing restaurant kitchen fire suppression system inspections, recharging and hydro testing and also ABC and K fire extinguisher inspection recharging and hydro testing, so i have questions about it, please answer them i will really appreciate it 1 can you tell me the rates roughly for inspection of kitchen fire suppression system and ABC and K fire extinguishers 2 rates for recharging of kitchen fire suppression system with different tank sizes and ABC and K fire extinguishers 3 if you can tell me these rates for 2 or 3 different scenarios for example cartridge vs pressure or different sizes tanks 4 i need to get training and i prefer online training any suggestion of a website where they train you in restaurant kitchen fire suppression i tried calling lot of places here in dc area but no body will tell me that because i think they are worried that i will be there competition

  • @MdMarufHossain-vc6yh
    @MdMarufHossain-vc6yh 4 года назад

    Thanks you sir

  • @tarassu
    @tarassu 4 года назад

    What is the cost compared to new extinguisher?

    • @bertlarsen3202
      @bertlarsen3202 4 года назад

      I reckon it's about the same price

    • @gmc1966
      @gmc1966 2 года назад

      We sell new 10 pounders for around 110 bucks or more depending on the brand. A hydro/recharge with new valve and O ring,about 52 dollars

  • @alvaalgood9393
    @alvaalgood9393 4 года назад

    Also determine if the extinguisher is or is not regulated by DOT Code of current USDOT regulations.

  • @jonathannoriega3025
    @jonathannoriega3025 4 года назад

    Hello I was wondering if you offer hands on training for fire extinguishers?

  • @joshuaborem7063
    @joshuaborem7063 4 года назад

    I'm going by memory here but I think the Parker O lube is not the correct one for that extinguisher...

  • @khawk7365
    @khawk7365 5 лет назад

    I'm in Alabama. I am a nicet 1 and 2 alarms and level 1 inspection. What is the certification that I would need to do hydro and 6 year maintenance on extinguishers?

  • @prettycureforever7102
    @prettycureforever7102 5 лет назад

    No wonder we can't feel the a.c in our building the goods are stealing or sucking the air out

  • @Essays4College
    @Essays4College 5 лет назад

    Was this guy doing this video without a mic?

  • @corywilliamson61
    @corywilliamson61 5 лет назад

    nice job!

  • @jamesjordanarmentor7485
    @jamesjordanarmentor7485 5 лет назад

    Thanks for the great info!

  • @earlr9381
    @earlr9381 5 лет назад

    Do you have a video explaining the impact of a vacuum (low pressue) created within the Kitchen when all the air is sucked out by the exhaust fan ? If we simply open a window to allow return air from outside to enter into the building then no point having an airconditoner on for customers because hot air from outside is continuously entering the restaurant. So how do you fix this ? Do I need a Economizer Relief Systems ? But these systems are not about Exhaust fans (removing air) but rather about supply fans (pushing air into the buikding). I'm so confused hope you can explain thus :)

  • @chasermanx77
    @chasermanx77 5 лет назад

    Is there a name or band of the device used at the 1:45 mark that blows out the excess powder? Or is that Custom made? I work for a Fire Extinguisher Service company in Maryland and are building out a new room for servicing extinguishers any help would be much appreciated thank you!

    • @joshwoodsmusic7979
      @joshwoodsmusic7979 5 лет назад

      Chase Castle they make a vacuum device that you tip the extinguisher over and it sucks the remaining powder. He was using it in the beginning

  • @DevenderSingh-ob4if
    @DevenderSingh-ob4if 5 лет назад

    ,.

  • @Mrbfgray
    @Mrbfgray 5 лет назад

    You can blow them into a running engine too.

  • @lewisbrand
    @lewisbrand 5 лет назад

    Being in the business myself I think cartridge operated fire extinguishers should be banned , you have no idea what condition they are in before squeezing the lever.

    • @dougbailey392
      @dougbailey392 5 лет назад

      Lewis Brand simply remove the fill cap and inspect the internal tank and agent, then weigh the cartridge. You simply cannot do that on a stored pressure extinguisher ... and that pressure gauge is a $2 item.

    • @Йурег
      @Йурег 4 года назад

      what an idiot

  • @tomsmith6706
    @tomsmith6706 5 лет назад

    Could you make a video about working over appliances in a sanitary and safe way?

  • @tomsmith6706
    @tomsmith6706 5 лет назад

    Thank you for taking the time to make this video. It's really great info if you're training to prepare for your certification.

  • @ernie5187
    @ernie5187 6 лет назад

    So the powder gets discharged into the hopper. But what about the nitrogen going into the air in the room? At work we recharge 30-40 5lb. Extinguishers in 6 hours. Is it safe to breath in all that nitrogen? Thanks

    • @justanotherguy8791
      @justanotherguy8791 5 лет назад

      By volume, dry air contains 78.09% nitrogen, 20.95% oxygen, 0.93% argon, 0.04% carbon dioxide, and small amounts of other gases.

    • @ernie5187
      @ernie5187 5 лет назад

      Greg Dinert....never new that, So is it safe? Is it ok as long as their is good ventilation?

  • @ironmatic1
    @ironmatic1 6 лет назад

    Nice earrape at the end