How to Create Crisp and Modern HMI Graphics using Figma (In-Depth Tutorial) NEW
►► Grab My FREE GUIDE Featuring 5 easy steps to Drastically Improve the Structure of your TIA PLC Applications:
www.plcskilltree.com/free-guide-optin
►► Learn Advanced TIA Portal PLC and HMI Programming functions and features in the PREMIUM edition of my TIA Portal - All Basics Pack:
www.plcskilltree.com/bundles/tia-portal-all-basics
*►► Get 15% discount on all courses and bundles by using coupon code TIAPORTAL15OFF at checkout.*
Getting started with TIA Portal has never been so easy.
Let me help you become a confident and structured TIA programmer TODAY.
VIDEO CONTENT
00:00 - Intro
02:23 - What is Figma?
04:11 - First Steps
06:36 - User Interface
08:49 - Button Design Example 1
24:34 - Button Design ...
Просмотров: 9 069

Видео

How to Add a Structured VFD Control to your TIA Portal PLC Application (4 Step Tutorial)
Просмотров 23 тыс.9 месяцев назад
►► Grab My FREE GUIDE on How to Drastically Improve the Structure of your TIA PLC Applications Right Here: www.plcskilltree.com/free-guide-optin ►► Learn Advanced TIA Portal PLC and HMI Programming functions and features in the PREMIUM edition of my TIA Portal - All Basics Pack: www.plcskilltree.com/bundles/tia-portal-all-basics *►► Get 15% discount on all courses and bundles by using coupon co...
Brand-New TIA Portal Product Coming Soon...
Просмотров 3 тыс.Год назад
►► Grab My FREE GUIDE on How to Drastically Improve the Structure of your TIA PLC Applications Right Here: www.plcskilltree.com/free-guide-optin If you liked my PLC and HMI courses, then you're absolutely going to LOVE this new product that I'm about to launch. Stay tuned, subscribe to the newsletter by getting the guide above, and soon you'll be able to add premium TIA Portal PLC and HMI featu...
How to Add User Administration to your TIA HMI Project - Step-by-Step Tutorial (Full Course Chapter)
Просмотров 5 тыс.Год назад
►► Grab My FREE GUIDE on How to Drastically Improve the Structure of your TIA PLC Applications Right Here: www.plcskilltree.com/free-guide-optin ►► Learn Structured TIA Portal PLC and HMI Programming in ONE DAY - Get Instant Access to my Trusted Online Training Courses Right Here: www.plcskilltree.com/store This video contains the complete 6th (out of 9) chapter "User Administration" of my comp...
6 Reasons TIA Portal DOMINATES Simatic Manager: A Comprehensive Step 7 Comparison in PLC Programming
Просмотров 6 тыс.Год назад
►► Grab My FREE GUIDE on How to Drastically Improve the Structure of your TIA PLC Applications Right Here: www.plcskilltree.com/free-guide-optin ►► Learn Structured TIA Portal PLC and HMI Programming in ONE DAY - Check Out my Trusted Online Training Courses Right Here: www.plcskilltree.com/store ►► Get your Free 21-Day Trial Version of TIA Portal Version 17 Right Here: support.industry.siemens....
Master TIA Portal: Build a PLC + HMI Application from Scratch in ONE DAY (Online Training Course)
Просмотров 2,9 тыс.2 года назад
►► Grab My FREE GUIDE on How to Drastically Improve the Structure of Your TIA PLC Applications Right Here: www.plcskilltree.com/free-guide-optin ►► Check Out My Short, Hands-On and No-Fluff TIA Portal Training Courses Right Here: www.plcskilltree.com/store *►► Get 15% discount on all courses and bundles by using coupon code TIAPORTAL15OFF at checkout.* Getting started with TIA Portal has never ...
How to Handle Multiple Languages in Your TIA Portal Applications | In-Depth Tutorial
Просмотров 7 тыс.2 года назад
►► Grab My FREE GUIDE on How to Drastically Improve the Structure of Your TIA PLC Applications Right Here: www.plcskilltree.com/free-guide-optin ►► Learn TIA Portal PLC and HMI Programming in ONE DAY in my Online Courses Right Here: www.plcskilltree.com/store In this video, I will show you how to setup different languages in TIA Portal, how to translate texts on individual screens, and how to e...
How to Structure Your PLC Program in TIA Portal Like a Pro (Full Course Chapter) | In-Depth Tutorial
Просмотров 55 тыс.2 года назад
How to Structure Your PLC Program in TIA Portal Like a Pro (Full Course Chapter) | In-Depth Tutorial
Simulation made easy: Learn how to Simulate PLC & HMI applications in TIA Portal
Просмотров 6 тыс.2 года назад
Simulation made easy: Learn how to Simulate PLC & HMI applications in TIA Portal
TIA Portal PLC Hack: Greatly Simplify IO Structures by using the power and structure of UDTs
Просмотров 4,9 тыс.2 года назад
TIA Portal PLC Hack: Greatly Simplify IO Structures by using the power and structure of UDTs
How to Import HMI Graphics in Bulk in TIA Portal (A little trick few people know about...)
Просмотров 13 тыс.2 года назад
How to Import HMI Graphics in Bulk in TIA Portal (A little trick few people know about...)
How to Create a Modern & Intuitive Screen Template for Your TIA HMI Application | Training Tutorial
Просмотров 21 тыс.3 года назад
How to Create a Modern & Intuitive Screen Template for Your TIA HMI Application | Training Tutorial
How Do I Create a New HMI Template in TIA Portal?
Просмотров 6 тыс.3 года назад
How Do I Create a New HMI Template in TIA Portal?
Unlock the Full Potential of Your HMI: Creating a Modern and Intuitive Interface in TIA Portal
Просмотров 2,1 тыс.3 года назад
Unlock the Full Potential of Your HMI: Creating a Modern and Intuitive Interface in TIA Portal
How to Add Intuitive Screen Navigation to Your TIA Portal HMI Template
Просмотров 9 тыс.3 года назад
How to Add Intuitive Screen Navigation to Your TIA Portal HMI Template
Simplify Your TIA Portal HMI Navigation: Learn to Add Screen Names to the Topbar
Просмотров 3,9 тыс.3 года назад
Simplify Your TIA Portal HMI Navigation: Learn to Add Screen Names to the Topbar
How do I Visualize the Current Date/Time in my TIA Portal HMI Application?
Просмотров 17 тыс.3 года назад
How do I Visualize the Current Date/Time in my TIA Portal HMI Application?
Easily Add a Start and Stop Button to Your TIA Portal HMI Template - Tutorial for Beginners
Просмотров 4 тыс.3 года назад
Easily Add a Start and Stop Button to Your TIA Portal HMI Template - Tutorial for Beginners
PLC Machine State Visualization Made Easy in TIA Portal HMI - A Step-by-Step Guide
Просмотров 3,1 тыс.3 года назад
PLC Machine State Visualization Made Easy in TIA Portal HMI - A Step-by-Step Guide
How to Add an HMI DEVICE to your existing TIA Project (TIA Portal Course)
Просмотров 4,6 тыс.3 года назад
How to Add an HMI DEVICE to your existing TIA Project (TIA Portal Course)
How to Create HMI TAGS for your TIA HMI Application (TIA Portal Course)
Просмотров 25 тыс.3 года назад
How to Create HMI TAGS for your TIA HMI Application (TIA Portal Course)
TIA Portal 101: Learn to Manage your PLC Applications like a Pro
Просмотров 7344 года назад
TIA Portal 101: Learn to Manage your PLC Applications like a Pro
TIA Portal 101: The Beginner's Guide to Starting a New Project
Просмотров 1,9 тыс.4 года назад
TIA Portal 101: The Beginner's Guide to Starting a New Project
How to Download your TIA Portal PLC Application to S7-PLCSIM (TIA Portal Course)
Просмотров 7 тыс.4 года назад
How to Download your TIA Portal PLC Application to S7-PLCSIM (TIA Portal Course)
Master TIA Portal: Learn to Program Step 7 PLC Applications from Scratch in this Introduction Course
Просмотров 1,9 тыс.4 года назад
Master TIA Portal: Learn to Program Step 7 PLC Applications from Scratch in this Introduction Course
Expert Guide to TIA Portal Function Blocks: Pro Insider Tips and Best Practices
Просмотров 15 тыс.4 года назад
Expert Guide to TIA Portal Function Blocks: Pro Insider Tips and Best Practices

Комментарии

  • @ademuwagunoladipupo1188
    @ademuwagunoladipupo1188 6 часов назад

    This is a great video. Thanks for showing advanced data structures like STRUCT in this video.

  • @tendekaidotdev
    @tendekaidotdev 2 дня назад

    Thanks man. This is an awesome tutorial.

  • @mr.write1433
    @mr.write1433 10 дней назад

    i dont have the simatic drive ? how will i see it ?

    • @PLCskilltree
      @PLCskilltree 10 дней назад

      Not sure what you mean

    • @mr.write1433
      @mr.write1433 8 дней назад

      @@PLCskilltree I already fix the problem. My version of TIA portal has no sinamics driver so i download it separately on their website.

  • @mr.write1433
    @mr.write1433 10 дней назад

    Tia portal integration to vfd kinda complicated…

    • @PLCskilltree
      @PLCskilltree 10 дней назад

      It’s not the only way to communicate, but it’s a structured way

    • @mr.write1433
      @mr.write1433 8 дней назад

      @@PLCskilltree Your videos are helpful. There's no video on the details of the function blocks though ?

    • @PLCskilltree
      @PLCskilltree 8 дней назад

      @@mr.write1433that information is in the course itself - link in the description below the video.

  • @teknosistem
    @teknosistem 15 дней назад

    Thank you sir.

  • @EmmanuelAkudike
    @EmmanuelAkudike 15 дней назад

    Please I can't find the finish refill program at the resource section of the course

    • @PLCskilltree
      @PLCskilltree 15 дней назад

      If you purchased the course, the refill application can be downloaded from one of the first lectures. It cannot be downloaded here on RUclips.

  • @user-pu1jw2ye3y
    @user-pu1jw2ye3y 15 дней назад

    Very good lesson. I and very impressed by your lecture. Thank you for your efforts and contribution to improving knowledge.

  • @mr.write1433
    @mr.write1433 16 дней назад

    Ow hes selling the graphics !!

    • @PLCskilltree
      @PLCskilltree 15 дней назад

      Check out my Figma tutorial on how to make these Hmi graphics yourself

  • @davewarmer2375
    @davewarmer2375 23 дня назад

    Do you cover any videos/training on unified comfort panels?

    • @PLCskilltree
      @PLCskilltree 23 дня назад

      Not yet no, but I’m considering adding it to my next course

  • @sofianetidjani
    @sofianetidjani Месяц назад

    Good explanation to every newcomer

  • @bilelmoussaoui8418
    @bilelmoussaoui8418 Месяц назад

    very good video, your are an amazing teacher thanks

  • @davidmurray1878
    @davidmurray1878 Месяц назад

    how do you use the function blocks? how did you get a pump section? where did FB- Control pump come from?

    • @PLCskilltree
      @PLCskilltree Месяц назад

      Hi David, The meaning of this tutorial is not to explain the application that I am using, it is to point out some important insights and tips on function blocks in general.

  • @davidmurray1878
    @davidmurray1878 Месяц назад

    i have a floating license for v16 but one of my customers has v14. I have 2 days left on a v14 trial. cant my v16 run v14?

    • @PLCskilltree
      @PLCskilltree Месяц назад

      It will update the V14 to V16. Afterwards it will stay V16. Normally you should use the version of the customer.

  • @davidmurray1878
    @davidmurray1878 Месяц назад

    does the online program continue to run during the download? is it a live edit

    • @PLCskilltree
      @PLCskilltree Месяц назад

      Depends. For small network edits (e.g. extra instructions in your ladder logic), PLC does not go in stop. When you start changing UDTs or DBs, it might go in to stop. But it will always tell you before it does. So you can decide not to go through with it.

  • @davidmurray1878
    @davidmurray1878 Месяц назад

    you have an on delay time in your function block but you want to try a different value maybe from 75ms t0 5 seconds. then keep those changes when you find a comfortable fit. but temporary at first and on a live system.

    • @PLCskilltree
      @PLCskilltree Месяц назад

      Sure you can do that online without PLC going into stop

  • @user-wl4my6ue7e
    @user-wl4my6ue7e Месяц назад

    1st of all - PRO never ever use LAD... just and only SCL. If you are using something else - you can't call youself a PRO or saying how PRO would do it. (other then SCL for PRO - it's 10-20 years ago was TRUE, right now - FALSE)

    • @PLCskilltree
      @PLCskilltree Месяц назад

      Haha, I strongly disagree but appreciate your honesty. The language does not define the skill level. Every language has its purpose, I happen to prefer ladder logic and been doing this professionally and very successfully since 2003 with industry leading machine builders. Your professionalism in PLC programming depends on how you can create modular and organized logic, NOT which language you use.

  • @ColinDickie
    @ColinDickie Месяц назад

    Can this be simplified using Technology Objects?

    • @PLCskilltree
      @PLCskilltree Месяц назад

      As far as I know, technology object are for motion axes = servo axes, not for VFDs.

    • @ColinDickie
      @ColinDickie Месяц назад

      It can be done with Technology Objects as I've done it. However, in my instance it was still using Telegram 1, and it resulted in over simplifying everything. I will be using your method from now on, which I hope will give me more control. Thank you!

  • @Kozak450
    @Kozak450 Месяц назад

    Nie bedziesz mi mówił jak mam programować.

    • @PLCskilltree
      @PLCskilltree Месяц назад

      Simply sharing what works for me - take it or leave it

  • @vijaipackiri238
    @vijaipackiri238 Месяц назад

    Dear friend... some of the blocks are already created in previously. So Need to create all by this session video itself. Then only easy understand this all

    • @PLCskilltree
      @PLCskilltree Месяц назад

      Thanks for your feedback. If you want to know how the program was made from scratch, please go and check out my courses in the description.

  • @PLCskilltree
    @PLCskilltree 2 месяца назад

    ►► Grab My FREE GUIDE Featuring 5 easy steps to Drastically Improve the Structure of your TIA PLC Applications: www.plcskilltree.com/free-guide-optin

  • @PLCskilltree
    @PLCskilltree 2 месяца назад

    ►► Grab My FREE GUIDE Featuring 5 easy steps to Drastically Improve the Structure of your TIA PLC Applications: www.plcskilltree.com/free-guide-optin

  • @PLCskilltree
    @PLCskilltree 2 месяца назад

    ►► Grab My FREE GUIDE Featuring 5 easy steps to Drastically Improve the Structure of your TIA PLC Applications: www.plcskilltree.com/free-guide-optin

  • @mehdikeyvani6179
    @mehdikeyvani6179 2 месяца назад

    thanks for your advanced tutorial , as a question? do you have tutorial about free telegram in your premium course?

    • @PLCskilltree
      @PLCskilltree 2 месяца назад

      The premium course uses the same telegram as the video. Why would you want to use a free telegram?

  • @yakubuauwallawan621
    @yakubuauwallawan621 2 месяца назад

    Its a wonderful video. How would i download the graphics?

    • @PLCskilltree
      @PLCskilltree 2 месяца назад

      Thanks. The graphics can be downloaded when you purchase my HMI course.

  • @Ronin_Martial_Arts
    @Ronin_Martial_Arts 2 месяца назад

    Just staring off using TIA Portal. Excellent video. I like the structure of it and well explained. Thanks

    • @PLCskilltree
      @PLCskilltree 2 месяца назад

      Awesome, thank you!

    • @Ronin_Martial_Arts
      @Ronin_Martial_Arts 2 месяца назад

      @@PLCskilltree I've signed up for full premium tutorial. I might be asking a few questions 🤔😁

    • @PLCskilltree
      @PLCskilltree 2 месяца назад

      Have you bought the premium bundle on my website? I did not get a sale from you so far (unless it’s under a different name)

    • @Ronin_Martial_Arts
      @Ronin_Martial_Arts 2 месяца назад

      @@PLCskilltree different name, Bucknorris74.

    • @PLCskilltree
      @PLCskilltree 2 месяца назад

      @@Ronin_Martial_Arts perfect, any questions before, during or after the course, send them In the course itself or to hans@plcskilltree.com

  • @ElectricsCars430
    @ElectricsCars430 2 месяца назад

    😘😍

  • @fabriciodepaula8025
    @fabriciodepaula8025 2 месяца назад

    Muito obrigado por dividir seu conhecimento.

  • @chrisredfield8698
    @chrisredfield8698 2 месяца назад

    Hi Hans chris again 😊. I've followed your steps and i created the "Standard Vfd Control FB", i've never thought it would be this easy especially the abuse of UDTs. But i wanted to ask about COMMISSIONING (inserting the motor data etc..), do you do it as a second step or do you follow another method ? Thanks in advance 🙏

    • @PLCskilltree
      @PLCskilltree 2 месяца назад

      Hi Chris, My video about creating the software is the first step, before the commissioning. Then during commissioning you will need to setup the VFD - give it an IP address, configuring the motor data like voltage, current, rpm, power etc.... I typically get the motor data from the data plate on the motor (picture with mobil phone) and I use the setup on the BOP screen of the VFD to set the applicable parameters to the correct values. I also write down the motor data for each motor in my project worksheet, just so I have a backup.

    • @chrisredfield8698
      @chrisredfield8698 2 месяца назад

      1- I apologize for skipping ahead of the video i'am just a bit excited😋 2- It seems that my Noob brain and its short term memory had a misunderstanding. I thought that "VFD control FB + commissioning" was enough and forgot about adjusting the VFD's Parameters through it's BOP/AOP so it can be controlled by the PLC through PN like in our example. Signature NOOB_Lvl_ONE_THOUSAND

  • @chrisredfield8698
    @chrisredfield8698 3 месяца назад

    I appreciate the time and effort you've put into this. Pls keep pumping these kind of lessons as they are gold to us. But i have a QUESTION in terms of "byte swapping", would keeping the bits as you declared in the video instead of bit15 to bit8 then bit7 to bit0 affect the control of the vfd or not ?

    • @PLCskilltree
      @PLCskilltree 3 месяца назад

      Hi Chris, Thanks for your nice words, happy to hear you get something out of these videos. If you do not do the byte swapping, then your VFD control will not work (because your bits 0 to 7 will be switched with 8 to 15). Was that your questions?

    • @chrisredfield8698
      @chrisredfield8698 3 месяца назад

      @@PLCskilltree Yes sir you've answered my question

  • @chrisredfield8698
    @chrisredfield8698 3 месяца назад

    I can't thank you enough for this PROFESSIONAL GUIDE 🤩you're truly a man of the FIELD. I have few questions from an AUTOMATIOIN NOOB 😋: 1- Why do we need to use "memories" such as "iLevel" and "xLowLevel" ? aren't these values taken from real inputs (tag table) ? 2- What benefits and oppertunities can we acquire by stocking an "input" in a "memory" instead of using the "input" right away (e.g water referrence in the HMI) or for e.g stocking the "true signal" that passed through "conditions" in a "memory" than transferring that to "output" ? 3- Do you do this by a simple "move" function or is there another method 🧐 As a NOOB i "Take" values from "inputs" directly and "Send" signals to "ouputs" also directly.

    • @PLCskilltree
      @PLCskilltree 3 месяца назад

      Hi Chris, Thanks for your feedback, love it! 1- "iLevel" and "xLowLevel" are part of the module data structure. And yes they are copied over from real inputs. There are a couple advantages to this. First off, it makes troubleshooting easier because all relevant data is easily accessible in the data structure. If you go online and open the DB where the module structure is situated, you get a great overview of what is happening in that module. Secondly, some inputs are being manipulated or scaled before they can be used (like e.g. scaling of a 0 to 100 degrees temperature sensor input). So instead of scaling this input every time that you use it, you scale it only once and add it to your module data structure. Now if you want to use it in another location in your PLC application, you can take the value directly from your module data structure (which is already scaled) instead of taking the input again. 2- Explanation is above 3- In case of simply moving the input, then yes a MOVE instruction will suffice. If you need to scale the input, then you might need a CALCULATE instruction, or even a small FC that takes care of the scaling calculations. I would recommend using an input (or an output) only 1 place in your user application. That input or output typically belongs to a specific module. So add it to that module's data structure. Furthermore, inputs and outputs should never be used directly in re-usable function blocks, always assign them to the Input or Output of the block interface. Else your function block is dependent on those exact inputs or outputs and cannot easily be copied to other projects or cannot be called multiple times in your application if needed. I hope this helps clarify things. -Hans

  • @user-hf1wj8bl9x
    @user-hf1wj8bl9x 3 месяца назад

    Hello hans. Do you also teach in your hmi program about display event (not alarm) . And also using OB of plc?

    • @PLCskilltree
      @PLCskilltree 3 месяца назад

      There’s a complete lecture in my HMI course dedicated to system diagnostics. I’m only using OB1 in my courses but I might update my premium content with interrupt OBs.

  • @angelrivera3192
    @angelrivera3192 3 месяца назад

    It’s to complex and there are a existing functions for this in the library of the software

    • @PLCskilltree
      @PLCskilltree 3 месяца назад

      I disagree about it being complex. It’s actually straightforward with simple steps. If you’re used to building structures for your plc applications then this example is relatively easy. Can you send me a link to the library that you are mentioning?

    • @nicholasfender869
      @nicholasfender869 День назад

      Sina_speed or Sina_Para ?

  • @user-hf1wj8bl9x
    @user-hf1wj8bl9x 3 месяца назад

    Hi. Your videos are awesome. Im interested in your courses but i want to know what are the knowledge i will learn in the course. I already bought courses before but i didn't expect what i need. Thanks Hans

    • @PLCskilltree
      @PLCskilltree 3 месяца назад

      Thanks. You will learn how to build structured TIA PLC and HMI applications from scratch, not just loose concepts or isolated examples - complete and fully functional applications. If you go to my website www.plcskilltree.com, you can read much more about each course or bundle and there are plenty of testimonials from people who took my courses. That should give you a good idea.

  • @kiarashiravani7104
    @kiarashiravani7104 3 месяца назад

    hi thank you for good video👌👌👌

  • @shoutxp1534
    @shoutxp1534 3 месяца назад

    How did the button turn blue when you pressed it

    • @PLCskilltree
      @PLCskilltree 3 месяца назад

      You select a graphic for the “off” state (=when not pressed) and another graphic for the “on” state (=when pressed). So basically 2 images.

  • @jgklinghardt
    @jgklinghardt 3 месяца назад

    Hi, great videos! To add multiple graphics I drag from Windows folder and drop in then they all are loaded at once.

    • @PLCskilltree
      @PLCskilltree 3 месяца назад

      Thanks for your feedback!!

  • @cricketisagame
    @cricketisagame 3 месяца назад

    Thanks for eye opening video

  • @suriyat8773
    @suriyat8773 3 месяца назад

    Thank you

  • @david.
    @david. 4 месяца назад

    You were a little quick on showing your statehandler fb. I couldn't see the whole code and I didn't understand, how you have an integer indicating the state, when all your states are boolean (at least if its the same as in the "how to organize your project"-video)

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      The complete code is available as a download in the full course which much more information.

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      The integer is used as the state representation as a number. It’s used for defining the conditions for switching from one state to another. The boolean states are status flags for the actual states. You would use those booleans in other parts of your logic. Hope this clears it up.

  • @simxschl
    @simxschl 4 месяца назад

    Being a huge fan of the TIA portal, I find it pityful that the inbuilt PLCSIM can't perform any communication to 3rd party applications. In my job I also need to use Schneider Electric's mediocre Control Expert IDE and their little simulator allows communication which is a must for our company. I fear that the high license fees for TIA and its PLCSIM Advanced will eventually make us switch to Schneider and its Control Expert and Automation Expert

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      I think that’s maybe a bit much to ask from a PLC simulator no? 😃 S7-PLCSIM allows you to simulate both PLC and HMI super easy with a click of a button, even simulating servo drives. I just used it to run several servo axes in positioning tasks using only my laptop.

    • @simxschl
      @simxschl 4 месяца назад

      @@PLCskilltree apparently not, if the Control Expert simulator manages to deliver this feature. The CE simulator has other weaknesses like wrong memory mapping sometimes but that's another story

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      @@simxschl I have experience with Rockwell and Siemens simulators and the TIA S7-PLCSIM is by far the easiest to use with most features. I do not have experience with Schneider simulators so you could be right, it might be better. But it doesn’t help you with simulating TIA Portal applications , which is what I am interested in 😃

    • @simxschl
      @simxschl 4 месяца назад

      @@PLCskilltree true that...

  • @eisasatari3777
    @eisasatari3777 4 месяца назад

    HI , There is no TELEGRAM option in my added drive properties 🤔 can you guide me ? thanks in advance

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      Which drive did you add? Which plc are you using?

  • @muhammadganji1529
    @muhammadganji1529 4 месяца назад

    🎉🎉🎉🎉🎉

  • @andrei4311
    @andrei4311 4 месяца назад

    problem of the FB's is that in fact you have double memmory usage. Each input and output are stored in instance memmory. You have UDT as "iq" parameter and you store same memmory in global variable as well in your instance..so you expend you memmory usage. So i exceed the work memmory limit by creating "big" projects ( 50 valve's , 20 motors, 40 Switches etc...) Solution: replaced all to the FC's and use the counter for count the time and its reduce my memmory usage at least to 40%... :) I still think that the best praxis to use the FB's only in OOP (example TwinCat/Beckhoff) there you can create the object(class) and work almost without "global variables" and you will avoid double usage of the memmory as well many benefits from OOP. Waiting Simatic AX

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      Using the InOut of an FB only passes the UDT through to the FB, like a gateway (=call-by-reference). Using the Input and Output of an FB required copying to and from the instance data of the FB = requires extra resources. I only use FCs for small repetitive tasks that don’t require static memory, like small calculations, conversions, or scaling operations. I use practically only FBs in my projects (and they get very big) and I never had problems with work memory (retained memory is a different conversation)

  • @elnino9139
    @elnino9139 4 месяца назад

    What if I already had an existing HMI Project ?

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      Not sure what your question is, please be more specific

    • @elnino9139
      @elnino9139 4 месяца назад

      @@PLCskilltree I have 2 seperate projects. One has only the PLC and the other has only the HMI. Now I want them to be in the same project so I just copy the HMI from the HMI-Project to my PLC with drag and drop. After that I set the PN/IE connection for them and try to simulate the programm. THe Problem is that on my screen I only see for example #### instead of the value that I drag and drop from a data block. So I-m trying to solve that problem. Maybe you could help me ?

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      @@elnino9139try and check your PG/PC interface (start typing “PG” in the start menu of your Windows). Make sure it’s configured with the correct network adapter. In case you’re running a simulation on your laptop, it should be set to PLCSIM. In case you are downloading to a hardware PLC and run a simulated HMI on your laptop, it should be configured with the network adapter that you use for downloading to your hardware PLC. The hashtags indicate that there is no connection between your HMI and PLC. Check as well if “Connections” is set up correctly in your HMI application.

    • @elnino9139
      @elnino9139 4 месяца назад

      @@PLCskilltree Thanks for the helping. I have figured it out. The problem was that I chose in the loading plc menu X1 instead of PN/PE_1. And then it forced me to type some password for PLC and I forgot. Thats a bit rough but I think I will copy the Data seperately to my new plc in another project. Hope it will work as well

  • @juhotoivanen7832
    @juhotoivanen7832 4 месяца назад

    When i follow these exact step creating HMI tags and connecting them to my PLC tags via HMI_connection its requires an address for the tag even though i am using datablock tags. I've tried to find a way to change absolute access to symbolic access but the program wont let me and doesnt even offer the possibility. In my global datablock properties the "optimized" option is grey and i cannot activate it. I am using a S7-300 PLC. Can anyone help me with my problem?

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      S7-300 PLCs do not support optimized block access. This video is made for S7-1200/1500 controllers.

  • @warasali7875
    @warasali7875 4 месяца назад

    Very good video 💯❤ your teaching way are so deferent. Thank you

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      How is it different? Would be nice to know 👍🏻

  • @shawnbraganza9020
    @shawnbraganza9020 4 месяца назад

    Great video

  • @amarnathnsw9392
    @amarnathnsw9392 4 месяца назад

    Pls sir make video on profibus communication

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      Profibus is kind of an outdated technology, I prefer to create videos on newer technologies

    • @amarnathnsw9392
      @amarnathnsw9392 4 месяца назад

      @@PLCskilltree ok but in India most place we are used sir

    • @PLCskilltree
      @PLCskilltree 4 месяца назад

      @@amarnathnsw9392 I understand