Fast Heat | Hot Runner Maintenance - MoldXChecker (Registered Patent No.: US 9,983,252 B2) (PT 1)
Просмотров 1,5 тыс.4 года назад
Fast Heat | Hot Runner Maintenance - MoldXChecker (Registered Patent No.: US 9,983,252 B2) (PART 1)
Fast Heat | Hot Runner Cable Maintenance
Просмотров 9094 года назад
Fast Heat | Hot Runner Cable Maintenance | CableXChecker (Registered Patent No.: US 9,804,218 B2) Full Review - Hot Runner Temperature Controllers.
Fast Heat's MoldXChecker (Registered Patent No.: US 9,983,252 B2) The Hot Runner Mold Testing System
Просмотров 5924 года назад
Fast Heat's MoldXChecker (Registered Patent No.: US 9,983,252 B2) The Hot Runner Mold Testing System
Fast Heat's CableXChecker The Hot (Registered Patent No.: US 9,804,218 B2) Cable Testing System
Просмотров 5324 года назад
Fast Heat's CableXChecker (Registered Patent No.: US 9,804,218 B2) The Hot Runner Cable Testing System
Fast Heat | ATP Proof
Просмотров 1884 года назад
Fast Heat | ATP Proof - Hot Runner Temperature Controllers. Mold and Cable Checkers.
Fast Heat | Why Pinched Wires in Hot Runner Systems Are Dangerous and Destructive
Просмотров 1944 года назад
“Because if there is a pinched wire in there, as soon as you plug it into the controller, the controller will tell you if there is a pinched wire. But, how’s it going to do it? It’s going to do it violently. It’s going to cause a short, hopefully, pops a fuse on the card. If it does, then it stops there. But, shorts can be fast, violent and sometimes it gets passed that fuse. If it gets passed ...
Fast Heat | The Problem with Hot Runner Cable Testing
Просмотров 2654 года назад
“Everytime that we would go out to do a service call, all of the good cables were where? Yes, they were all on machines. Where were all of the bad cables? There inside of the tool room, maintenance right; somewhere where they were going to repair them.
Fast Heat | Better Way to Wire Hot Runner Cables
Просмотров 2404 года назад
“If it’s a heater, all I have to do is put all of the wires in. Doesn’t matter where we put it. We don’t have to worry about what pin it’s in (on the controller side), the wiring diagram is right here. If we're making a set of cables, all we have to do is grab (after wiring up the controller side) the wires and immediately we know we're going to put that inside of zone number eight. Grab my oth...
Fast Heat | A Better Way to Test Hot Runner Cables
Просмотров 1084 года назад
“We're going to show you how easy it is to detect everything we just did, plus you don’t have to know the wiring diagram, because the wiring diagram is right on here. So if you have a 24-pin connector, it tells you 24-pin connector. If this had two connectors on it, it would have say a 25 pin and a 24 pin right on the label and the wiring diagram is right here - 1 and 13, 2 and 14 and so on and...

Комментарии

  • @edgarhernandez4529
    @edgarhernandez4529 2 месяца назад

    Hot runners never get proper reading due to being disconnected from the neck instead of the head

  • @edwinlucero30
    @edwinlucero30 6 месяцев назад

    Manny Diaz, a very intelligent person.

  • @inquisitive980
    @inquisitive980 11 месяцев назад

    Always checked before production. My problem with Fast Heat is the limited shutoff between the runner nozzle and the cavity. This caused a great amount of manifold leaks. Quit using their systems for this

  • @allaboutmould2252
    @allaboutmould2252 Год назад

    What should be the measurement value of the thermocouple?