Laars Heating
Laars Heating
  • Видео 81
  • Просмотров 834 679
Installers like Ray, Recommend Laars
Laars Heating Systems has a solution that will meet today's residential heating needs. Laars residential gas boilers can be installed in small spaces allowing for more living space and less mechanical room space. Laars offers a series of residential boilers that are combination space heating and hot water boilers. These combination boilers, or combi boilers, handle both central heating and domestic hot water in one unit.
Просмотров: 137 352

Видео

LT Series Recirculating Model Water Heater, Tom Kelly
Просмотров 4632 месяца назад
This is the LT Series (recirculating model) Tankless Water Heater. In this 9 minute video, Tom Kelly gets into the basics of the LT Series, recirculating model, water heater. For full details on this high efficiency water heater, please visit the product page on laars.com 00:00 - Introduction. 00:16 - Top Three Reasons to go Tankless. 01:15 - Commercial Capabilities. 01:45 - Common Venting. 02:...
LT Series Standard Water Heater, Tom Kelly
Просмотров 2582 месяца назад
This is the LT Series (standard model) Tankless Water Heater. In this 6 minute video, Tom Kelly gets into the basics of the LT Series water heater. For full details on this high efficiency water heater, please visit the product page on laars.com 00:00 - Introduction. 00:16 - Top Three Reasons to go Tankless. 01:15 - Commercial Capabilities. 01:48 - Common Venting. 02:14 - Various Features. 03:5...
MagnaTherm Heat Exchanger, Cleaning.
Просмотров 4265 месяцев назад
This video is a step by step instruction to cleaning the water tube heat exchanger of the MagnaTherm 5:1 and the MagnaTherm HTD (20:1). 00:00 - Introduction. 00:12 - Open the front doors and remove the side panels. 00:42 - Remove the insulation and the shrouds. 02:48 - Pre-2016 VS Post-2016. The bands. 04:02 - The ‘Tadpole’ gaskets of Post-2016. 04:30 - Remove and inspect the baffles. 04:52 - R...
MagnaTherm 20:1 Combustion, Using the AZL.
Просмотров 2265 месяцев назад
Step by Step. This video shows the qualified installer how to do a 20:1 Combustion Setup using the AZL control on the MagnaTherm FT and/or the MagnaTherm HTD 00:00 - Introduction. 00:36 - Check Static and Dynamic gas pressure. 01:02 - Log-in and then go to ‘Configuration’. 01:26 - Disable O2 Trim. 02:00 - Elevate CH1 Setpoint. 02:45 - Increase Time Out. 03:36 - Enable Manual Heat Demand. 04:35 ...
FT Series 301 / 399 Wall Boiler Combustion Setup
Просмотров 2427 месяцев назад
This step by step video shows how to do the combustion setup for the FT Series Wall Boilers. 00:00 - Introduction. 00:40 - Check incoming static gas pressure. 01:48 - Set up a call for heat. 02:25 - Cover must be on to test CO2 02:45 - DIP Switches. Set DIP 6 to ON, Hi-Fire 04:01 - Back to Low fire to adjust at gas valve. 04:35 - Adjust at gas valve at Low Fire. 05:24 - Check CO2 once more, the...
NeoTherm XTR Combustion Setup. All Sizes.
Просмотров 2177 месяцев назад
This video is the step by step procedure to do the Combustion Setup for the XTR boilers and water heaters. 00:00 - Introduction 00:12 - Location of Hi and Low Fire adjustments on all 3 possible gas valves. 01:45 - Start by getting to the gas valve. 02:20 - Gas pressure. 02:55 - Log into the display. 03:12 - Increase CH1 setpoint, and clear your safeties. 04:30 - Go to Firing Rate and increase T...
MagnaTherm 5 to 1, Combustion Setup
Просмотров 1067 месяцев назад
This video shows the step by step combustion setup procedure for the MagnaTherm 5 to 1 models with the SIT Display. These are all models from 2018 and up, with SIT display. 00:00 - Introduction 00-15 - Check static gas pressure. 00:48 - High Fire and Low Fire gas adjustment locations on gas valve. 01:25 - Firmware was updated in July of 2022. 02:08 - Adjust CH1 set point. 02:30 - Go to Firing R...
FT Series Boilers (all sizes), Basic Installer Parameters.
Просмотров 1,7 тыс.10 месяцев назад
This video shows the Installer the Basic Setup Parameters for the FT Series Boilers (all sizes, floor and wall). It's a 7 minute step by step guide to setting the basic installer parameters and Steve Moruzzi offers several examples as to why installations are different and what you should do differently in your installation, given your installation requirements. The FT Series Combi models are v...
FT Series (all sizes), Soak and Scrub Technique.
Просмотров 1,3 тыс.11 месяцев назад
This video shows the best technique to clean your FT Series boiler or combination boiler. Your boiler or combi may be trying to tell you that there is a blockage or a cleaning needed. Please look up the error codes as listed in your Installation Manual. 00:00 - Introduction. 00:18 - Tools Needed. 00:47 - Is a fully cleaning neccesary? 00:57 - Various Error Codes and Indicators. 01:50 - Step by ...
MagnaTherm FT, Burner Removal and Inspect / Clean the Heat Exchanger.
Просмотров 50811 месяцев назад
This video is a step by step instruction into the top of the MagnaTherm FT (fire-tube), so that the heat exchanger can be cleaned. This is a linear assembly, so keep track of the gaskets in the sequence as they are removed! Re-assemble in the reverse order. Always order the Burner Gasket and Flame Sensor and Igniter Gaskets in advance as they must be replaced if they are damaged.
Laars Is
Просмотров 341 тыс.11 месяцев назад
Laars is the boiler of choice when replacing your boiler.
FT Series 301 / 399 and Floor Stand Assembly
Просмотров 482Год назад
The FT Series 301 / 399 boiler has an optional floor stand that can be installed by one person if necessary. Follow this video instructional and the Assembly Instructions that come with the stand.
FT Series Floor - Removal of blower and burner
Просмотров 1,3 тыс.2 года назад
Removing the blower from a floor standing FT is a little different from the wall mounted models. The display and it's bracket is mounted right where the blower needs to come forward and out. In this video, Mike Manos shows the licensed contractor exactly how to make this job quick and easy. 00:00 - Introduction. 00:23 - Tools Needed. 02:58 - Do Not mix up these bolts! 03:28 - Inspect the burner...
FT Series, (Residential) Combustion Setup
Просмотров 2,8 тыс.2 года назад
This video shows the licensed contractor how to perform the combustion setup on the FT Series residential boiler. All of the FT series boilers (wall and floor) are very similar in how the combustion is properly dialed in for the highest efficiencies. Refer to your installation manual for the CO2 readings and gas pressures for your model. 00:00 - Introduction. 00:28 - If propane, remove the plug...
Trust Laars
Просмотров 91 тыс.2 года назад
Trust Laars
OmniTherm Combustion Setup, Laars Academy, 2021
Просмотров 8552 года назад
OmniTherm Combustion Setup, Laars Academy, 2021
Laars Linc Part 5 Cascading
Просмотров 3682 года назад
Laars Linc Part 5 Cascading
Laars Linc Service Training Part 5 - Cascading
Просмотров 8212 года назад
Laars Linc Service Training Part 5 - Cascading
OmniTherm, Combustion Setup. Adjusting the Gas Valve at the Gas Valve Display. V2
Просмотров 9442 года назад
OmniTherm, Combustion Setup. Adjusting the Gas Valve at the Gas Valve Display. V2
Laars Commercial Tankless Electric Water Heaters
Просмотров 1,9 тыс.3 года назад
Laars Commercial Tankless Electric Water Heaters
FT Series Wall (residential) - Burner Removal and Inspection
Просмотров 2,3 тыс.3 года назад
FT Series Wall (residential) - Burner Removal and Inspection
FT Series Wall (residential), Pump and 3-Way Valve Remove & Replace
Просмотров 1,7 тыс.3 года назад
FT Series Wall (residential), Pump and 3-Way Valve Remove & Replace
FT Series Wall (residential), Fill and Purge
Просмотров 4,4 тыс.3 года назад
FT Series Wall (residential), Fill and Purge
Laars Linc Service Training Part 6 - Service
Просмотров 6893 года назад
Laars Linc Service Training Part 6 - Service
Laars Linc Service Training Part 4 - Config, Firing Rate, Misc
Просмотров 2613 года назад
Laars Linc Service Training Part 4 - Config, Firing Rate, Misc
Laars Linc Service Training Part 3 - Config, Pumps and VariPrime
Просмотров 2203 года назад
Laars Linc Service Training Part 3 - Config, Pumps and VariPrime
Laars Linc Service Training Part 2 - Configuration
Просмотров 3883 года назад
Laars Linc Service Training Part 2 - Configuration
Laars Linc Service Training Part 1 - Home, Padlock, Quick Start
Просмотров 4933 года назад
Laars Linc Service Training Part 1 - Home, Padlock, Quick Start
Mini-Therm JX DHW Kit Installation.
Просмотров 1,2 тыс.3 года назад
Mini-Therm JX DHW Kit Installation.

Комментарии

  • @TrulysWorld-fi8sx
    @TrulysWorld-fi8sx 2 дня назад

    IM FAMOUS!!! (I’m the one with the orange shirt Truly)

  • @brettknighten1171
    @brettknighten1171 27 дней назад

    Can these units be used as only a baseboard heat boiler and turn the DHW off

  • @robertdonatiello870
    @robertdonatiello870 2 месяца назад

    Where can the condensate tubing with vent be purchased? Just got the error code 20 and noticed my installer didn’t use the vented tubing - just hard pipe! So a link to the proper tubing would be very helpful

  • @mikekeary7268
    @mikekeary7268 3 месяца назад

    Is this possible on the 3000 model??

    • @LaarsHeating
      @LaarsHeating 3 месяца назад

      Yes this is a feature on the 3000 model as well.

  • @kinzieconrad105
    @kinzieconrad105 5 месяцев назад

    Water tubes are safer than fire tube! Very nice piece of equipment. Scariest experience of mine was finding a fire tub boiler that ran dry with a stuck float valve! First thing to do is cut the water feed clossest to boiler as possible. Cause if you cut the fire first, because you can get a thermal shock the releases the stuck float valve and "boom your dead!"

  • @Da1what
    @Da1what 5 месяцев назад

    That’s regular dirt…be careful with the white coating!😮

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 5 месяцев назад

    Great video and explanation

    • @LaarsHeating
      @LaarsHeating 5 месяцев назад

      Glad you liked it! and Thank You for commenting!

    • @nebbrooklyn5966
      @nebbrooklyn5966 4 месяца назад

      See you guys in June. Siemens azl taking over

  • @lucille284
    @lucille284 5 месяцев назад

    Would this trick be required each time you try to flush and clean the system also?

  • @AlfredoDaza123
    @AlfredoDaza123 5 месяцев назад

    Hola que piensan ustedes de este problema q padezco en un edificio de 24 pisos en la línea de apartamentos E del 14 piso así a abajo el agua sale caliente en el lado frío y tarda en normalizarse

    • @LaarsHeating
      @LaarsHeating 5 месяцев назад

      ¿Donde está esto? ¿Y has llamado a nuestra línea de soporte técnico? ¿O habló con su representante en su área? Perdón por la demora en la respuesta, pero RUclips no se suele utilizar para brindar soporte técnico.

  • @AlfredoDaza123
    @AlfredoDaza123 5 месяцев назад

    Que piensan ustedes sobre el tema , un edificio de 24 pisos y la línea E del 14 para abajo sale agua caliente en la occion de fría en ocaciones y no emos podido resolver

  • @rodmanlott175
    @rodmanlott175 6 месяцев назад

    Very helpful. I had error 44 usually my drain plugged with white gunk but this time screen past blower (model 140) half blocked with bugs. Also noted the white gunk might be due to intake and exhaust being too close.

  • @robertlee8805
    @robertlee8805 6 месяцев назад

    Bought and had it installed. But the manual is not as good at showing how to take things apart. Glad I found LAARS Combi on RUclips on how to take it apart but sort of know what to do. Would like it of you'd use a visible (thick enough to see what you're pointing to without blocking the exact screw you're removing and putting back together. POINTER like an antenna with a comedy pointer head would be perfect to show what you're talking about.

    • @LaarsHeating
      @LaarsHeating 6 месяцев назад

      Good morning Robert! I will be sure to pass this information to our team for future videos. It's a great point. Thank you for choosing Laars

  • @vadimtyutyunnik353
    @vadimtyutyunnik353 6 месяцев назад

    Why I'm getting an error message after brend new installed SIT pcb?

  • @boxingfanjavier27
    @boxingfanjavier27 7 месяцев назад

    I have the same machine, the problem is, the heat always on, to hot inside the house and thermostat is off, any help thanks

  • @boxingfanjavier27
    @boxingfanjavier27 7 месяцев назад

    I have the same boiler in my house, something wrong with the boiler, the heat always on, i set up the temperature to 68 and she goes to 77, i dont know

  • @MudLakeRanch
    @MudLakeRanch 7 месяцев назад

    I be arw so 75& You

  • @audenandersen1549
    @audenandersen1549 8 месяцев назад

    Hi mike did a cleaning on the larrs heating boiler . After cleaning I can’t seem to get a way from an error 40 . Gas leakage . I check out your video to see if I missed a gasket but seems like I didn’t. I’m ordering new gasket . Are you fimiliar with an issue like this? Do your top burner plates ever warp ?

  • @thowe689
    @thowe689 11 месяцев назад

    Don’t mind the error code title. It shows how to troubleshoot the system

  • @curiousone7863
    @curiousone7863 11 месяцев назад

    Are you sure about using Rydlyme? When I checked their website, it doesn't list it as being safe on aluminum and the heat exchanger fins are aluminum are they not?

  • @juancotiy8325
    @juancotiy8325 Год назад

    RN42

    • @LaarsHeating
      @LaarsHeating 11 месяцев назад

      Good morning @juancotiy8325 - please contact our Technical Support team for assistance with this code. They can be reached at 800.900.9276 option 3. Thank you for choosing Laars!

  • @eh9692
    @eh9692 Год назад

    What amazing company, they boilers and tankless are some of the best money can buy!!😀

  • @lucille284
    @lucille284 Год назад

    Would love to see videos of the newer model P 920-C control panel.

    • @LaarsHeating
      @LaarsHeating 11 месяцев назад

      Good morning - we are working on updated videos however both controls work the same and have the same codes. If you have specific questions on error codes, please feel free to contact our Technical Support team at 800.900.9276 option 3. Thank you for choosing Laars!

    • @lucille284
      @lucille284 10 месяцев назад

      Thank you very much!@@LaarsHeating

  • @s60t5M
    @s60t5M Год назад

    Do you have a video on combustion setup for the JX series?

  • @yidelr.6345
    @yidelr.6345 Год назад

    When are these boiler available

    • @LaarsHeating
      @LaarsHeating Год назад

      Good morning - these are currently available to order from your local Laars distributor.

  • @curiousone7863
    @curiousone7863 Год назад

    I really appreciate this expert training.

  • @barryschuschke9149
    @barryschuschke9149 Год назад

    199 combo error code 11 ignition has failed 10 times. Checked the power from the 2 wires going to the ignitor transformer. Shows 16 to 18 volts not 120. They are sending a new board. Is there anything else that could cause this. Brand new boiler. Thank you

    • @LaarsHeating
      @LaarsHeating Год назад

      @barryschuskhke9149 please contact our technical support team at 800.900.9276 x6579. The team has some questions for you before they can give a final answer. Thank you!

  • @9mroot
    @9mroot Год назад

    ive got this unit. with t stat unhooked and the circulation pump unplugged, it is still feeding hot water to the baseboards. is there a valve of some type allowing hot water to the baseboards?

    • @LaarsHeating
      @LaarsHeating Год назад

      Hello - please contact our technical service team for assistance at 800.900.9276 and they will be able to help you. Thank you!

  • @Brett.284
    @Brett.284 Год назад

    These boilers are a nightmare to work on. Currently tearing the heat exchanger out for cleaning

  • @moyeedulhasan5870
    @moyeedulhasan5870 Год назад

    Hi I have got an er 16 code in my new LAARS MASCOT FT. No hot water no heating. Don’t know what do!? It’s just installed at 2019. Very disappointed to have problem so early..

    • @LaarsHeating
      @LaarsHeating Год назад

      Hello Moyeedul - Please contact our technical support team at 800.900.9276 or reach out to a contractor in your area by utilizing the contractor locator found on www.laars.com. You can contact me via email at communications@laars.com if you prefer.

    • @moyeedulhasan5870
      @moyeedulhasan5870 Год назад

      Thank you, a plumber replaced the inner pump. Now it’s working…

    • @hjciprian
      @hjciprian 10 месяцев назад

      How much he charge you?

    • @hjciprian
      @hjciprian 10 месяцев назад

      ​@@moyeedulhasan5870$$??

  • @robertshawiii8489
    @robertshawiii8489 Год назад

    I have a an indoor problem when it's really cold outside and it's about 57 degrees indoors and I take a space heater on the thermostat and it brought up the temp to 60 degrees and it only goes up 68 degrees

  • @Canadaistheanwser
    @Canadaistheanwser Год назад

    Is that 1" gasket strip necessary. Does not show it in tbe assembly diagram for Laars 300 boilers

  • @foymechanical914
    @foymechanical914 Год назад

    Great video very simple and easy to understand. Thanks guys.

  • @Jusfourfun
    @Jusfourfun Год назад

    What is the best solvent used to remove dirt and grime from the heat exchanger?

    • @LaarsHeating
      @LaarsHeating Год назад

      Hi Landon - we recommend lightly spraying the heat exchanger with water then use a brush to clean the heat exchanger. Feel free to contact our technical support department at 800.900.9276 for any assistance.

  • @jbstrongman
    @jbstrongman Год назад

    I’m confused. Is this separate from a pump that circulates the water through the system?

  • @damianstasek8946
    @damianstasek8946 Год назад

    What a terrible design. 14 years in the field and this is one of worst. I dred days I need to service/pm these boilers.

  • @zeroheat5787
    @zeroheat5787 Год назад

    Just picked one up for my parents home. I like the packaged low loss header. I usually make my own with Mechanical tees and a piece of pipe, but I opted for this cutie. I've installed 4 of these in my 22 years of plumbing/heating. Each time I've built a steel base with pipe and flanges as feet welded onto a 1/4" plate to raise it up off fhe floor and leveled by the flanges on the floor. For my parents, I opted for a Buderus horizontal indirect heater so i can sit the boiler on top. I don't need to make a base and will have more space in the boiler room for storage. Love Laars. Rathe Associates has classes on all their products if youre in the NYC area. Stay flowing Y'all.

  • @hossrismani2485
    @hossrismani2485 2 года назад

    You are a good teacher. Thank you

  • @krishna-e-bera
    @krishna-e-bera 2 года назад

    Our Laars furnace works great. Fairly simple to see and change the settings, and low maintenance.

    • @LaarsHeating
      @LaarsHeating 2 года назад

      That's great to hear your feedback! Thanks for letting us know.

  • @tomb375
    @tomb375 2 года назад

    Is there a major difference in the 199 models between the floor mount and the wall mount? I could do either one. Thank you.

    • @LaarsHeating
      @LaarsHeating 2 года назад

      Hi Tom - There are some unique aspects of the floor boiler that our contractors find helpful in installation and annual service. I would recommend contacting your local Laars sales rep and they can give you an overview of each. www.laars.com/support/sales-representatives. Thank you!

  • @jupena
    @jupena 2 года назад

    I'm getting error code 80, water won't flow throughout the boiler. There's definitely water coming in, but it will not go out. Any advice would be greatly appreciated!!🙏🏼🙏🏼🙏🏼

    • @LaarsHeating
      @LaarsHeating 2 года назад

      Hi Juan - Have you tried using our contractor locator at www.laars.com/support/contractor-locator? That would be a great start. You can also email me at marketing@laars.com and I can help to get you connected with someone that way as well. Thank you!

  • @kirstenmckay2831
    @kirstenmckay2831 2 года назад

    Need more people so spread this video more

  • @cappachino007
    @cappachino007 2 года назад

    Everything looks so easy when it's brand new and have extra hands. Great job on the video. Currently having an issue. Auto high limit. Replaced filter but still nothing. Pump runs but no call for heat. The unit is @ 130°. Aquastat is set for 165°. Target set at 175°. Low water cut off keeps blinking. Unit runs when I jump aquastat to manual reset but interlocks light stay on

    • @LaarsHeating
      @LaarsHeating 2 года назад

      Please call our Tech Support Number during working days 7 am to 5 pm Eastern Time. 1-800-900-9276

  • @ashleyjustice8288
    @ashleyjustice8288 2 года назад

    👇 🅿🆁🅾🅼🅾🆂🅼

  • @dave25kool
    @dave25kool 2 года назад

    How much H series cost?

  • @livingthedream335
    @livingthedream335 2 года назад

    Hi Mike, Can a dedicated hot water recirculation line be tied in to FT Series 199 BTU model without an additional pump? Any info you have on this greatly appreciated. Thanks!

    • @LaarsHeating
      @LaarsHeating 2 года назад

      I can forward this message on to Mike. The service and training team doesn't monitor our RUclips channel. Best to call 1-800-900-WARM (9276) for technical assistance. Thank You

  • @mezianemeziani2956
    @mezianemeziani2956 2 года назад

    I have error code 16, and a noise coming out of the internal pump ( sounds like something is loose inside) and it’s leaking at the connection to the 3 way valve. The DHW works just fine. When the pump screw is loosen, water is leaking though the pump ( not sure if this is normal). I have 2 of these units installed in February 2018, and since I never went through a winter without one of them having a issue in the worst day of the season. So far we replaced 1 control board, 2 3 way valves, a pump. It’s disappointing to say the least!

    • @LaarsHeating
      @LaarsHeating 2 года назад

      Please look at the Error Codes in your Installation Manual. For the FT's, Error Code 16 is 'Operating Temperature Sensor detects Water Temperature Greaterthan 203°F (95°C)' Please let me know what you have done thus far in your diagnosis of this 16 error code.

    • @mezianemeziani2956
      @mezianemeziani2956 2 года назад

      The pump was the issue, the unit worked fine after the replacement of the pump

    • @EverydayMiniVlogs
      @EverydayMiniVlogs Год назад

      I currently have this same problem. I never go a winter without an issue neither.

    • @EverydayMiniVlogs
      @EverydayMiniVlogs Год назад

      @@mezianemeziani2956 did you have to pay for it or the warranty covered it ?

    • @hroman_codes
      @hroman_codes Год назад

      I just moved into our new home and we have a new FT Series combi. I also saw some water leaking through the pump when I unscrewed the pump. Is this normal? BTW I am also getting an error code 16 on a new machine. 😞

  • @eddiegaray7863
    @eddiegaray7863 2 года назад

    I need the meaning for AP13 error on a boiler

    • @LaarsHeating
      @LaarsHeating 2 года назад

      What kind of boiler? FT residential? Boiler? or combi/boiler? Thank You.

  • @chuckh2d
    @chuckh2d 2 года назад

    A lifesaving video. This is the same setup as the dreaded HTP EFTC-140/199W, which 99 out of 100 plumbers in Massachusetts refuse to work on. It's also high season for COVID and the coldest part of the winter, so once my one-of-100 plumbers got sick there was nothing to do but replace the 3-way pump myself. (What's a warranty worth if no one will do the work? As one plumber after another said to me, "The reason I can't service your boiler is if I open it, I own it. It's probably the valve but...") Obviously this is not recommended for non-plumbers, but I'm reasonably handy...and really had no other choice. The short version is that (1) a wide jaw basin wrench is essential: the front nut is 1 3/8" and there is not room between the cabinet frame and the plastic top of the internal pump for a plumbers wrench or adjustable wrench to make even a minimum 60° turn. And (2) the front gasket is a non-standard diameter which stumped the two nearest plumbing supply stores and two oldschool hardware stores (mind you, it's COVID and supplies are bad on everything). Fortunately Harbor Freight's "Tap Reseater Washer Assortment" includes two of the correct size. (The OEM washers were mashed so tight on my 2018 HTP 199W - and had baked so hard - that after a sixth of a turn to loosen the nut I was able to unscrew both nuts by hand. As far as diagnosing the problem is concerned, the 3-way valve appears to be by far the most common problem with these units. Because the non-functioning 3-way valve does not open to CH/heating zones (it only makes hot water/DHW for the house), the CH out and CH return pipes warm rapidly during startup and/or while the DHW/hot water comes up to temperature, but - even though the zones are still calling for heat - the burner shuts off because the temperature of the CH return is already over the maximum. You may suspect that an external circulator pump is the problem instead, but you can check by removing power to the external pump and setting only one zone to call for heat. The internal pump has plenty of power to force a couple of zones-worth of CH through the idle external pump, so if the external pump IS bad you'll feel hot water flowing through the external pump to the zone[s]. Assuming no other failures surface this video was everything I hoped for. Thanksagain.

    • @LaarsHeating
      @LaarsHeating 2 года назад

      Excellent! Yes, we design our videos to be useful for techs like you (and even handy non-plumbers, as long as all safety guidelines are followed as outlined in the Installation Manual!). Steve Moruzzi and Ken Resnick have a nack for taking the complicated and keeping it simple. We'll have more FT videos this year! Thank You for buying Laars!

    • @mtx450
      @mtx450 Год назад

      Good call on getting those washers from Harbor Freight. I looked up the part numbers and they are just 3/4" and 1" rubber washers (they call them "packing"). The parts distributors and supply houses want over $20-30 each!! Am I missing something or is that just highway robbery?

  • @abccommercialproperties300
    @abccommercialproperties300 2 года назад

    Any recall on ignitor. We have this elephant for about three years and had 20 service calls and dozens of ignitor failing. Any advice?

    • @LaarsHeating
      @LaarsHeating 2 года назад

      The igniters for the MT2 (2400-286) are very consistent. Dozens of them failing? Please contact our Tech Support Team at 800-900-9276 !

  • @bobmariano3731
    @bobmariano3731 2 года назад

    How can I get a video of cleaning the outside coils of my Laars mini therm JVH ? Installed 2006 it also makes a humming sound when it runs ? ? Is this normal ? ?

    • @LaarsHeating
      @LaarsHeating 2 года назад

      The Mini-Therm JVH has copper tubes. They're not 'coils' and I would always recommend that servicing your Mini-Therm should always be done by an experienced and trained HVAC Technician. With that said, it's not a complicated boiler to service. Were you able to get the humming sound addressed?

    • @bobmariano3731
      @bobmariano3731 2 года назад

      Appreciate the reply, haven’t had it serviced yet, hard to to someone or an experienced HVAC person out to check it out. Previous owners said it was last serviced in 2017. The person they used is retired, been trying to get in touch just to let me know what they did when it was serviced. It’s still makes a humming sound while turning on however ……is this normal ? Appreciate any advice & help you may have on this unit . Thanks so much again . Bob

    • @LaarsHeating
      @LaarsHeating 2 года назад

      @@bobmariano3731 if you want to contact me with your location and phone number, we can connect you with someone in your area that can assist you. My email is marketing@laars.com. Thank you!