Summit Fire and Safety Equipment
Summit Fire and Safety Equipment
  • Видео 9
  • Просмотров 71 932
FIRE EXTINGUISHER CLEANUP How to Clean After Discharging an ABC Dry Chemical Unit
In this video we demonstrate how to clean extinguishing agent from items that were in the extinguisher's "blast zone"
If we have ever cleaned after a fire has been put out with a dry chemical extinguisher, then, we have probably wondered if the cure was worse than the disease.
The ammonium phosphate is that fine, yellow powdery fallout that was blasted over a surprisingly large area. Ammonium phosphate softens and sticks when in contact with hot surfaces. While this characteristic makes it a great extinguishing agent, it sometimes makes cleanup very difficult. ABC dry chem can do serious damage to delicate equipment and corrode metal, especially if it is not thoroughly cleaned.
You may fin...
Просмотров: 34 861

Видео

Amelia Discusses another Life-Saving Fire Safety TipAmelia Discusses another Life-Saving Fire Safety Tip
Amelia Discusses another Life-Saving Fire Safety Tip
Просмотров 16510 лет назад
Amelia Ann Taylor, a State Certified Portable Fire Extinguisher Specialist, shares an important fire safety tip. In case of fire, do you know where to go for the nearest extinguisher?
Protect Yourself from Cyber Bullying, Stalking, and Harassment - Interview: Alan SpenceProtect Yourself from Cyber Bullying, Stalking, and Harassment - Interview: Alan Spence
Protect Yourself from Cyber Bullying, Stalking, and Harassment - Interview: Alan Spence
Просмотров 24611 лет назад
Alan Spence has worked with computers and personal devices for many years. He has been a part of I.T. and I.S. departments, he hosted a successful pod cast on technology, and he now works with the department responsible for computers throughout a large national movie theater company. In this interview he shares ways to protect ourselves from cyber bullying, stalking, and harassment.
One Minute Could Save Your Life: Interview with Former Fire Chief, Bill GordonOne Minute Could Save Your Life: Interview with Former Fire Chief, Bill Gordon
One Minute Could Save Your Life: Interview with Former Fire Chief, Bill Gordon
Просмотров 9311 лет назад
Former Fire Chief takes less than 60 seconds to tell us how to protect our family and home from an insidious fire hazard. More information on this subject can be found at: www.nfpa.org/safety-information/for-consumers/causes/dryers-and-washing-machines
Fire Extinguisher: Why Recharge ASAP? (1 min.)Fire Extinguisher: Why Recharge ASAP? (1 min.)
Fire Extinguisher: Why Recharge ASAP? (1 min.)
Просмотров 2,1 тыс.12 лет назад
This video was made to answer the question: "Why must extinguishers be recharged immediately after use, even if only partially discharged?" If we stop a fire with only a small amount of extinguishing agent, the gauge may still show correct operating pressure and the weight may indicate it is still full. The obvious Question is: "Why should we have the unit recharged as quickly as possible?" In ...
Fire Extinguishers: The Danger of Not Recharging (SHORT VERSION)Fire Extinguishers: The Danger of Not Recharging (SHORT VERSION)
Fire Extinguishers: The Danger of Not Recharging (SHORT VERSION)
Просмотров 4,6 тыс.12 лет назад
This video was made to answer the question: "Why must extinguishers be recharged immediately after use, even if only partially discharged?" If we stop a fire with only a small amount of extinguishing agent, the gauge may still show correct operating pressure and the weight may indicate it is still full. The obvious Question is: "Why should we have the unit recharged as quickly as possible?" In ...
Fire Extinguishers: Danger of Not RechargingFire Extinguishers: Danger of Not Recharging
Fire Extinguishers: Danger of Not Recharging
Просмотров 27 тыс.12 лет назад
This video was made to answer the question: "Why must extinguishers be recharged immediately after use, even if only partially discharged?" If we stop a fire with only a small amount of extinguishing agent, the gauge may still show correct operating pressure and the weight may indicate it is still full. The obvious Question is: "Why should we have the unit recharged as quickly as possible?" In ...
When Must Fire Extinguisher Signs Be Used?When Must Fire Extinguisher Signs Be Used?
When Must Fire Extinguisher Signs Be Used?
Просмотров 1,3 тыс.13 лет назад
This video was made to answer the question "When must fire extinguisher signs be used and why are they necessary?" These links provide more information on this subject fireextinguisherman.wordpress.com/article/when-must-fire-extinguisher-signs-be-used-and-why-are-they-necessary/ www.tnsummitfire.com/signs.htm Bill’s Notes’ content has now been incorporated into Minute Reads and Summit Home page.
Why Plastic Collars on the Necks of Extinguishers?Why Plastic Collars on the Necks of Extinguishers?
Why Plastic Collars on the Necks of Extinguishers?
Просмотров 2 тыс.13 лет назад
Did you ever wonder why some extinguishers have a plastic collar around the neck just under the handle? Is it important? If the Fire Marshall or other Authority Having Jurisdiction (AHJ) inspects and notices a collar missing from an extinguisher that should have one, she may write a citation for the violation. Why? Bill’s Notes’ content has now been incorporated into Minute Reads and Summit Hom...

Комментарии

  • @DerekG
    @DerekG 7 лет назад

    Better cleaning up dry chemical than having to deal with the aftermath of a major fire. That said, alternatives like CO2 / Halon / Halotron / etc all present their own advantages / challenges. They are quite a bit more expensive than dry chemical, and CO2 can be very dangerous in an enclosed area. Clean Agents are safer (though they are expensive) and they can produce dangerous HF gas when used on hot fires. Regardless of the type of extinguisher once the fire is out (or getting too big to safely fight) you should evacuate until fire fighters arrive and tell you its safe to go back in.

  • @portagepete1
    @portagepete1 8 лет назад

    Ok so some engineer needs to improve the valve but that may not happen unless there is more money in making them better! 7 min video please talk like your speaking to adults and make it 1 min.

  • @michaelpetereffinger
    @michaelpetereffinger 8 лет назад

    SHOULD YOU BREATH THIS STUFF IN WITHOUT A MASK AND PROPER CLOTHING GEAR?

  • @goldwingman1500
    @goldwingman1500 8 лет назад

    In Oz they need a pressure test every 6 years no if,s or buts . The Valve is a spindle

  • @alvaalgood9393
    @alvaalgood9393 8 лет назад

    Very well done. . Over the past four decades I have also come across empty or partial use extinguishers with the gauge showing full charge. Excellent for training. Still too many people fluffing the chemical with a rubber hammer with can plug the gauge. Al g5alva@q.com

  • @fredbaker4127
    @fredbaker4127 9 лет назад

    I wanted to ask how long do cartridges in a cartridge extinguisher usually last? and it would seem if the extinguisher cartridge became bad I would just have to screw in a new cartridge? any thoughts are appreciated please thank you.

  • @goldwingman1500
    @goldwingman1500 9 лет назад

    Its good to get into the Habit of refilling all Fire Extinguishers after use as you might need a full charge next time you need it ?

  • @user6860
    @user6860 9 лет назад

    I just used a hose with a sprayer

  • @banksroadmodernimage7358
    @banksroadmodernimage7358 9 лет назад

    Does this apply to Halon/BCF extinguishers? Ive got two,both not used but one has gauge slightly in the red area now.

    • @arboretumvalley2360
      @arboretumvalley2360 9 лет назад

      class 66 so glad you commented on this one, who would have thought using one a little basically meant it was no use. We keep 3 car ones around the property. They have not been used, but I first had them when I had kids...so I am off to investigate and make sure they seem untouched.

  • @goldwingman1500
    @goldwingman1500 9 лет назад

    I have had Many customers tell me my Fire Extinguisher is Fine i tested it last week i tell them i will do it for Free if you can make it Work Now ,No Go powder every where they Must me refilled after use .

  • @Fredengle
    @Fredengle 10 лет назад

    well what if I have sodium bicarbonate or purple k do I use the same method?

  • @maxderuiter1
    @maxderuiter1 10 лет назад

    luckily this problem only occurs with dry chemical fire extinguihers. Water and foam extinguishers do not have this problem but it is always good to refill a fire extinguisher after use

  • @HimJimRimDim
    @HimJimRimDim 10 лет назад

    Yep, the dry chemical (chalk) types are a one shot deal. They must be thoroughly cleaned and recharged after every single discharge or partial discharge.

  • @Summitfireman
    @Summitfireman 11 лет назад

    Exercise caution when removing the valve assembly from an extinguisher. Occasionally a gauge malfunctions; indicating zero psi even though there is pressure. The valve may also fail to open when the lever is depressed. When this happens, the tech sees no indication of pressure in the extinguisher and so could be injured if care is not shown. Dry chemical units usually operate at 195 psi; CO2 extinguishers have a test pressure many times that amount. Thank you for the question.

  • @wildchild7029
    @wildchild7029 11 лет назад

    Yes it's safe. Remove the value assemble using a bench vise and turn anticlockwise the value.

  • @zartan7779
    @zartan7779 11 лет назад

    Hello i was looking to take apart a few old extiguisers. I have pulled triggers and nothing come out. Is is safe to remove the trigger value assemble?

  • @ezraspence
    @ezraspence 12 лет назад

    Very nice video Bill! I made that very mistake with our fire extinguisher... I should probably tell Dad! Lol oh and this was the first video I watched on the go on my iPhone :)

  • @Summitfireman
    @Summitfireman 13 лет назад

    @ezraspence Thank you for even more kind words

  • @ezraspence
    @ezraspence 13 лет назад

    Very nice. I like your videos cause they're done professionally. Keep up the good work!

  • @ezraspence
    @ezraspence 13 лет назад

    Nice video! :D I'll subscribe!