
- Видео 35
- Просмотров 74 360
TodayHVAC
Израиль
Добавлен 7 ноя 2017
Welcome to the TodayHVAC youtube channel
where the purpose of the channel is to give support, knowledge & education to air conditioning installers and costumers about HVAC issues.
TodayHVAC youtube channel is a private project of Mechanical Engineer Itay Ran.
Itay worked for the last 16 years as the product engineer of Econ-Tec LTD the importer of Mitsubishi Electric Air conditioners at Israel.
Subscribe now for:
Air conditioning planning
Air conditioning knowledge
air conditioner troubleshooting
help us make things bettter
where the purpose of the channel is to give support, knowledge & education to air conditioning installers and costumers about HVAC issues.
TodayHVAC youtube channel is a private project of Mechanical Engineer Itay Ran.
Itay worked for the last 16 years as the product engineer of Econ-Tec LTD the importer of Mitsubishi Electric Air conditioners at Israel.
Subscribe now for:
Air conditioning planning
Air conditioning knowledge
air conditioner troubleshooting
help us make things bettter
Outdoor Units Details of Model Name
tinyurl.com/CityMultiModelName
So how to read a model name? I mean how many times you saw these strange names and ask yourself “what is the meaning of this?” or “where did it came from?”.
So, let’s define what the model name is.
First of all, anybody watching this-you may not even know it, you all followed its rules.
Second, every letter that the manufacturer provides is important, especially if you are a planner, maintenance person or air conditioner technician.
So today I want to talk to you about the Mitsubishi Electric outdoor units’ details of model name.
The model’s name of the units is a group of characters, that each one of them describes the functionality of the unit.
Now let me explain...
So how to read a model name? I mean how many times you saw these strange names and ask yourself “what is the meaning of this?” or “where did it came from?”.
So, let’s define what the model name is.
First of all, anybody watching this-you may not even know it, you all followed its rules.
Second, every letter that the manufacturer provides is important, especially if you are a planner, maintenance person or air conditioner technician.
So today I want to talk to you about the Mitsubishi Electric outdoor units’ details of model name.
The model’s name of the units is a group of characters, that each one of them describes the functionality of the unit.
Now let me explain...
Просмотров: 145
Видео
Citymulti VRF-obstruction of airflow path
Просмотров 343 месяца назад
Citymulti VRF-obstruction of airflow path
2800CFM VRF AHU installation Beer Sheva
Просмотров 4073 месяца назад
2800CFM VRF AHU installation Beer Sheva
TodayHVAC Yt Channel Trailer jul.2024
Просмотров 753 месяца назад
TodayHVAC Yt Channel Trailer jul.2024
Bike trip on Saturday-Modiine Southern Hills Trail
Просмотров 174 месяца назад
Bike trip on Saturday-Modiine Southern Hills Trail
mastering the psychrometric chart for hvac engineers
Просмотров 805 месяцев назад
Hi guys link for the lesson: drive.google.com/file/d/1T9gaDEGvB4YfFL0YKcDcaGuLqy2lPZAy/view?usp=sharing So today I’m going to teach you how to calculate the cooling capacity of an air conditioning unit using this random example that I prepared for you here. So, 8500cfm of air is entering the air conditioning unit at conditions 1 which are 25°CDB/21°CWB And exit this cooling coil at 12°CDB and r...
Basic guide for PAR-CT01MAA Bluetooth
Просмотров 1735 месяцев назад
0020 Please note that Bluetooth is available for remote controllers with suffix SB or PB (you can see the model’s name at the bottom). The factory default setting for Bluetooth is off. You will see this sign on the screen- When Bluetooth is set to on. One more thing: if you have more than one controller, I recommend you see the “Complete guide for PAR-CT01 Bluetooth” link in the description. To...
blower bearing replacement
Просмотров 3676 месяцев назад
Let mo know what you think. mitsubishi electric PFAV Large capacity indoor unit blower bearing replacement
Bike trip on Saturday-Ben Shemen forest Blue route
Просмотров 336 месяцев назад
what do you think? Share us
PAR-21MAA change language
Просмотров 1417 месяцев назад
drive.google.com/file/d/1UIWJvOZ3UcxVnA1KAQTdEdrBiUsw71n5/view?usp=sharing Hi guys In addition to English, contents at the PAR-21MAA can be displayed in 7 other languages. So, to change the language: STEP1-press on the MODE & little ON/OFF together for 3 seconds, you will see “CHANG LANGUAGE” is blinking. STEP2-press separate presses on the MENU to change the language. Each pree will change the...
How Ocean Air Affects Air Conditioners
Просмотров 1067 месяцев назад
How Ocean Air Affects Air Conditioners
PAR-CT01MAA how to set the current time
Просмотров 1058 месяцев назад
PAR-CT01MAA how to set the current time
The complete guide for PAR-CT01MAA Bluetooth
Просмотров 4608 месяцев назад
The complete guide for PAR-CT01MAA Bluetooth
PAR-CT01MAA Remote Controller Introduction
Просмотров 27410 месяцев назад
PAR-CT01MAA Remote Controller Introduction
Mitsubishi Electric Mr.Slim. Refrigerant System diagram
Просмотров 23311 месяцев назад
Mitsubishi Electric Mr.Slim. Refrigerant System diagram
PAR 21MAA: movie 04/1 How to Set the Weekly Timer
Просмотров 772Год назад
PAR 21MAA: movie 04/1 How to Set the Weekly Timer
Choose between AHU troubleshooting or installation
Просмотров 258Год назад
Choose between AHU troubleshooting or installation
How to Self diagnosis with the PAC-YT52CRA
Просмотров 783Год назад
How to Self diagnosis with the PAC-YT52CRA
Why the COOL operation Mode is Blinking at my Mitsubishi Electric Remote Controller
Просмотров 6 тыс.Год назад
Why the COOL operation Mode is Blinking at my Mitsubishi Electric Remote Controller
How to change the External Static Pressure with the PAC-YT52CRA
Просмотров 608Год назад
How to change the External Static Pressure with the PAC-YT52CRA
PAR-21MAA: movie 02-Setting the Timer Type
Просмотров 1,6 тыс.Год назад
PAR-21MAA: movie 02-Setting the Timer Type
PAR-21MAA: movie 01-How to set the DAY and TIME
Просмотров 1,5 тыс.Год назад
PAR-21MAA: movie 01-How to set the DAY and TIME
How to READ the Room temperature from the PAC-YT52CRA built in temperature sensor
Просмотров 1,1 тыс.Год назад
How to READ the Room temperature from the PAC-YT52CRA built in temperature sensor
How to Lock or Unlock the PAC-YT52CRA buttons
Просмотров 11 тыс.Год назад
How to Lock or Unlock the PAC-YT52CRA buttons
Introduction to the PAC-YT52CRA simple MA remote controller
Просмотров 3,1 тыс.Год назад
Introduction to the PAC-YT52CRA simple MA remote controller
איתי אתה אלוף 👌
The hotel I am staying at currently uses this controller and the unit is set 'CENTRAL' with no options available. Is there any way I can get around this so I can adjust the temperature?
Sorry for the late response. No (The controller is controlled by a central controller and unfortunately I'm not aware of a way to get around this)
Ok, that's unfortunate. Thanks for the reply!
How do you know which mode the weekly timer is using? I have a weekly timer set but no clue what mode it's using. I want it to be in auto so that once it cools down to the set temperature it stops cooling.
What you set at startup is what will remain. If you set auto - it will remain auto (in the timer you usually only set on/off and at what time, sometimes there is also a condition - all the settings remain as they were...)
@@todayhvac Ok thank you so very much. 🙂
וועליה דודו
PEFY-P71VMH-E unit plz
you change the external ststic pressure by changing the motor plug wire as follows: BLACK color=100Pa, WHITE color=150Pa(factory settings), RED color=200Pa.
I think you might want to update your thumbnail. Just a thought. 😊
Hi, I have a pead-sm71ja2 interior unit. Looking to the unit instructions, it says to connect remote Wi-Fi controller to a connector CN90, with 9 pins.. I understand then the controller MAC-5871IF is not compatible right? Any possible connection? Or What is the compatible wifi controller I should buy? Thanks
Hi, the PEAD-SM71JA2 has a CN105 connector(red). as far as i know-the MAC-587IF-E is compatible with this indoor unit(i.e. please see the attached wiring diagram and the Indoor controller board). the CN90 is for Signal Receiving Unit PAR-SA9CA-E. drive.google.com/file/d/1cC5-ZE27RiZQpb6_nEBIzCu-4UNRKaVZ/view?usp=sharing
Hi, great video! I have several MSZ-SF42VE2 units that i need to integrate via cloud. I've opened one, but can't find the CN105. Is there any? Thanks!
hi, basically all the MSZ series has a CN105 connector. please send me an email to itay@todayHVAC.com and i will do my best to send you a picture of the location
מה זה
יש מצב שזה נוצר משערות של חיות
Mine was red up ... There was a picture next to the wire and plug
It worked and saved our life. Thank you 🙏🏼
Glad it helped!
Oh vrf and AHU 😅😅 I m Vrf technician .
❤❤❤🎉🎉❤
Good job,I have one of the same AC it's showing ho
I have two questions and would greatly appreciate it if someone could answer them: 1) I have two MFZ-KT35VE AC units. Is this module compatible with them? 2) With this module, can I control my AC units through the Smart Life app? Thanks
1: you can connect the MAC-587IF-E to MFZ-KT35VG (i.e. i didn't find the exact model that you have mensioned will the suffix VE) 2: i will check
@@todayhvac thank you very much
Thanks!! The instruction book is so difficult 😂😂 This vid is going to help us save a lot of money this summer🎉
Glad it was helpful!
Hello, I would like to upgrade PAC-YT52CRA to a PAR-40MAA. Is it a simple replacement and will the MAA controller assume the settings on the controller board, or must the unit be completely reconfigured when upgrading the controller? I have a PEAD-SP100JA internal unit.
Hi, it is a simple replacemement, the PAR-40MAA will reacive your PEAD-SP100JA settings
Hello and thank you. I have a PEAD-SP100JA internal unit using a PAC-YT52CRA and I am also using an MAC-587IF-E WiFi controller with MELCloud. Do you know how to program the unit so that once the desired temperature is reached the fan unit will turn "off" completely versus the default low fan mode? Also, as per your video, when should the setting be set for room temperature versus the default?
Hi, Sorry for my late response: As for your first question: According to the manufacturer there is a function No. 25 (MODE 25) - "Fan speed during the heating thermostat is OFF". you can try MODE 25 setting 2 (setting 2 meaning is-fan speed STOP during thermostat is OFF during heating [It works on PEAD-RP units, I hope it will work on your PEAD-SP unit as well]). [i.e. MODE 27 setting 2 is the same as 25 but for cooling]. please see the movie ruclips.net/video/xTGc2HXPfEc/видео.html How to change the External Static Pressure with the PAC-YT52CRA and download the attachement 0009A From page 5: at step 6-choose 25 at step 8-chage it to 2 Do step 9 and continue to step 11 We'd love it if you let us know how it went. As for your second question-It is a bit more complex-I will try to make a movie about it in the future
@@todayhvac Thank you. I actually tried looking for both Mode 25 (Heat) and Mode 27 (Cool), as I wanted to set both to "Off". However, those modes are not available on the PEAD-SP and I can't find if there are different mode numbers for the unit. I guess I will keep trying. Thank you again for your response.
at this service call we clean only the indoor unit, why you are asking?
Didnt clean out the coils ?
The evaporator coil was cleaned with a damp cloth
That was half azz. If u take it apart to that degree, clean front back the whole thing with a fine tooth!
@@curseofthetraveler Thank you very much for the response, the comments are important to the viewers. In this particular case, crushing of the leaves was not observed, so there was no need to use a fine tooth
How can i Turn off the door Sensor?
hi, i hope i"m understand your question: There are switches on the back of the top case, SW No. 4 is about the Indoor temperature display on the Remote controller. Set it to OFF (OFF means that you don't want to display the indoor temperature on the remote controller)
Is there a energy saving mode at PAC-YT52CRA?
Thanks! It worked! (Now I'm no longer freezing!)
You are the best
Friend, I've done everything and I can't figure out how to change from F to C. Can you help me?
there are switches on the back of the top case. set dip switch no. 2 to ON in order to change to C.
is there a module to allow you to connect the aircond unit to internet by ethernet cable ? (not wireless but wired)
System controller AE-200 has ethernet connection
Announcement 17/04 : drive.google.com/file/d/1XSiHeP3wfpBQgyHzS01UwiQYECIicfBA/view?usp=sharing
My wifi unit suddenly lost connection yesterday after trouble free operation for over 2 years. No matter how many methods I try it just will not reconnect to my wifi. Is it possible for it to simply break and require replacement?
can you see what are the LEDs pattern? page 7 at the attached link drive.google.com/file/d/1l4vYDzHRTr-jXocEs4Oih4Iym6ASvGAZ/view?usp=sharing
@@todayhvac I can't remember now. So many different patterns but always involving the Orange (ERR) LED. Been trying all day and frankly so tired and frustrated now that I've given up.
if the NET the UNIT and the ERR are blinking mean that: Connection to MELCloud failed, and Connection to indoor unit established. Since you tell me you've tried everything and nothing works-Try talking to your installer who will contact the company
You did everything right, it's not a problem for you, there is probably a problem with Melcloud's servers
@@itayran981 thank you. All fixed now.👍
This helped me a lot when i stayed in a hotel, and i couldn’t figure out how to turn off the air conditioning which was set to freezing mode 😂
cheers!
Good video. But I have difficulties with connection. I think that module don't want to connect to my router
1. do you know the name of your indoor unit? 2. what is the name of the wi-fi interface?
@@itayran981 indoor unit is Lossnay. Wifi is 587. Someone said that i need to update firmware of ERV
hi Andrey. you can send me an email with the picture of your Lossnay model and i will ask the manufacturer if it can be connected via the MAC-587IF-E. i.e. it can take few days to reacive an answer form them.
@@todayhvac ok. I'll make photos tomorrow
@@todayhvac it will be great, because our local Ukrainian suppliers of ME don't have answers)))
Thank You!!
Hello I have a controlar with error H0 how i resolve this problem
This is usually can be due to a communication problem. it can be when the indoor unit is not recognize by the outdoor unit, if you are a Certified technician you can try to solve this by RESET the outdoor unit(Disconnect the voltage to the outdoor unit and turn it on again)
Check that there is 30VDC at the indoor unit TB5 (M1,M2,S) between M1 and M2
Yeah my only has drying option heat and cool. No auto option.
my i ask what is the mofel of your indoor unit?
Model # TAC-YT53CRAU(REF.J)
Dear Sir PAC-YT53CRAU-J is the name of the remote controller, you can find the name of the indoor unit on the model label sticker that is stuck on the indoor unit itself
How do I set the thermostat to auto?
you can set the thermostat to auto by Pressing the MODE button located at the at the bottom left(with the six icons on it). will change the operation mode in the following order: COOL->DRYING->FAN->AUTO->HEAT->VENTI. Note: Not all functions are available on all models of indoor units. Functions that are not available will not appear on the display.
hi, great video! I don't get the 00 option on the first two settings it starts at 01 and goes up to 50
hi. sorry for my late response. i thing that the reason for the phenomenon you described is beacuse you have VRF system(P_FY indooe unit). for most of the VRF system, in order to READ the temperature from the remote controller you need to make it by indoor unit Dip switch SW1-1=ON. may i ask what is the model of the indoor unit?
Model number is PVFY-P12NAMU-E. I tried the dip switch one however it’s made the thermostat a “sub” instead of main. Thank you so much for your help
the dip switch SW1 is located on the indoor unit PCB
Hello . Please some help. I conect the phone to the mitsubishi wifi, after that i canot conect to the 198.11... because i dont have net, the phone is on mitsubishi wifi. Should i disconect the mitsubishi wifi and then conect to 198.11...?
Hi, i hope i understand you correctly-please try to type 192.168.11.1/network. (today you can't get access to the wi-fi configuration screen if you type 198.11....., please open the movie Description )
So I have 6 units could i connect one remote to 6 so all of them have their own remote so I can go without adding as a group? We are installing them in a hotel, So we are trying to figure out if they can be separate or if they have to be controlled as a group
basically their are two ways: 1. you can connect one remote controller to all of your 6 indoor units-in that case it will operate them as a group(The controller will give the same setting to all of the indoor units, the maximum allowable indoor units that you can operate as a group are 16). 2. you can connect one remote controller for one indoor unit And each unit will operate according to the definition of its specific controller. if you want, you can email me a diagram to itay@todayhvac.com of what you want to do with the exact name of the indoor and outdoor units and I will give you an opinion
Thank you
Why i can't still turning on the weekly timer?
hi, It's a bit complex to know without a picture or video what the problem is. you can send me a vedio to my email itay@todayhvac.com via this free website www.jumbomail.me/l/en/home And I'll try to help. By the way, did you go through all the steps in the video? Is there any step you failed at?
Very good : precise, concise, efficient We wish all the tutorials on yutube were this good!,
Thank you very much
Thanks, it's a lifesaver.
Don't get lost, you are truly amazing.
Great info. I am searching for the CN105 on my SEZ-KD50VAQ, but I am not able to find it in the manuals (probably because it is an older model). After connecting the wireless interface, the wired controller (PAR-21MAA) will also be active - did I get it right?
please see the attached picture with the SEZ-KD50VAQ CN105 red connector. the PAR-21MAA will be active also drive.google.com/file/d/1C_B670NYw3m2oWXtwglhlmAzyB-V4-9T/view?usp=sharing
@@todayhvac I have managed to order the interface and even to connect it to the system - it works without any issues! The number of the connector (cn105) was written on the plate as well. Thank you for your assistance!!
I'm glad you made it, have a good day
תודה רבה!
Great video I have a EHSC-VM2D. Where is CN105 located?
the CN105 connector(Red color) located On the right side in the middle of the height of the P.c. Board. see the attached picture drive.google.com/file/d/1XIdzOT_G4T7urQlVLfJ7RniK6yrpshTq/view?usp=sharing
Good guide, very helpful. Thanks.
very cool, thank you very much and cheers from Germany :-)
Thank you so much for your guide : clear and effective ! The only issue : email adresse doesn't work. Need to connect with wps on your wifi router.
Hi, Sorry for my misunderstanding of your question. what do you mean "email adresse doesn't work"? do you mean that you can't connect to the wireless configuration screen by type 192.168.11.1(min 2:59)? or something else
by type 192.168.11.1 ?