- Видео 23
- Просмотров 155 755
Jephills Engineering Co.
Добавлен 9 июн 2017
At jephills Engineering, we supplies electrical and inverter materials, We handle Electrical contracts, inverter installations and general maintenances of building.
Distance is never a barrier.
Contact us on +2348130253049
Distance is never a barrier.
Contact us on +2348130253049
How to install/pipe 3 phase Distribution box.
How to install/pipe 3 phase Distribution box.
Просмотров: 1 205
Видео
How to wire full conduit electrical house wiring for aircondition, water heater and cooker sockets
Просмотров 93111 месяцев назад
How to wire full conduit electrical house wiring for air conditioning, toilet water heater and cooker sockets
How to wire half conduit electrical house wiring
Просмотров 1,7 тыс.Год назад
How to wire half conduit electrical house wiring
How to install an industrial extractor or ventilating fan.
Просмотров 1,2 тыс.Год назад
How to install an industrial extractor or ventilating fan.
How to connect a 3phase D4 distribution board
Просмотров 1,4 тыс.Год назад
How to connect a 3phase D4 distribution board
How to fish in electrical cables in conduit wiring @jephillsengineeringco.1394
Просмотров 256Год назад
How to fish in electrical cables in conduit wiring
How to cut pop ceiling and wire rope light.
Просмотров 245Год назад
How to cut pop ceiling and wire rope light.
How to pipe staircase/steps lights piping in the decking.
Просмотров 3 тыс.Год назад
How to pipe staircase/steps lights piping in the decking.
How to install lightening thunder arrestor.
Просмотров 1,8 тыс.2 года назад
Created by InShot:inshotapp.page.link/YTShare
How to install lighting thunder arrestor
Просмотров 6982 года назад
How to install lighting thunder arrestor
How to connect a 100amps 3phase 4pole change over switch
Просмотров 24 тыс.2 года назад
How to connect a 100amps 3phase 4pole change over switch
How to install lighting thunder arrestor
Просмотров 2582 года назад
How to install lighting thunder arrestor
How to pipe full conduit electrical piping
Просмотров 34 тыс.3 года назад
How to pipe full conduit electrical piping
How to install lightning thunder arrestor
Просмотров 82 тыс.4 года назад
How to install lightning thunder arrestor
How to install plastic bottle blowing machine
Просмотров 1104 года назад
How to install plastic bottle blowing machine
Can you make full video show us step by step of everything
Yes but not very soon, very busy lately..🙏
Nice boss, keep us updated
You're welcome
Where is your location
Abuja Nigeria
Pls how much will be your work manship if you wire my three bedroom house
Where is the location...?
Can we just have a group chat
Okay, go on....
Where will the cable from distribution board be connected to ?
It's connected at the earthing terminal or bar
You are doing well
Thanks alot dear....
What does salt do
Where is ur Office?
Abuja Nigeria
Bro u only show d finished line for the half conduit I want to c how u do it from d beginning to the end I mean from the ceiling
Noted, it will be shown in our next video
Dear Sir, adding industrial salt is not a good practice. I agree many people still do it. The reason why its not a good practice is that overtime the salt will corrode the copper matt and rod thereby rendering the setup ineffective for its purpose. Secondly its my observation that in all these earthing job videos there is no measurement produced and offered to the client to prove that what has been done is effective. This is a general problem that needs to be addressed and demanded by customers from their installers.
You're right
Pura bakar video banaraho
Pls remove it ... It is not standard . Am sorry to say ...if you want to know why... Come to me I tell you
Please, post it here so we'll all learn from it.
That circuit breaker down wat do you call it and what wire will you move there
It is called main switch and 16mm supply cable goes into it.
A fairly good job and presentation. Keep it up!
Thanks, will do!
I’ll like to work with you I’m in Lagos Nigeria
Wow.... That will be great, but we're currently based in Abuja.
Except when we have work within Lagos like last year we had some contracts at alakija navy town there in Lagos state.
Show me the neutral side of contactors and it phases
You can wire a ring circuit for the water heater using 2.5mm cable for 2 or more water heaters
You're very correct, ring circuit connection isn't a bad idea when you have a lower melemeter of cable.
How much do you receive for working Depending on location and house size
There is usually no fixed amount, it depends on our agreement and the size of the building.
Thank you Jephills for this wonderful video. ❤️ It is insightful and helpful.
Thanks alot sir, comments like this is what keep us going, we don't take it for granted, thanks once again..🙏
Waoo... The long awaited company, very good for your house wiring, tested and trusted, please patronize this company.❤
Thanks alot dear
Thank you Jephills. for this helpful video
It's my pleasure, Glad it was helpful
Very nice
Thanks alot
What wiring regulations are you using?
I use the 18th edition of wiring regulation which was amended in the year 2022.
please where is your location
Nigeria
If only we could see what's Happening up there, good going though
Noted, our next upload will capture the process very well, just subscribe and keep following up.
Nice 👍
Thanks alot ma
nice.
Thanks alot boss
Please I'm an electrician,I have learned this work for 4 years and I have graduated, so pls I would like to ask if there is any chance for me to work in ur company pls 🙏
Okay, where is your location..?
Please I'm an electrician,I have learned this work for 4 years and I have graduated, so pls I would like to ask if there is any chance for me to work in ur company pls 🙏
Where is your location...?
Please I'm an electrician,I have learned this work for 4 years and I have graduated, so pls I would like to ask if there is any chance for me to work in ur company pls 🙏
Okay, no problems
Please I'm an electrician,I have learned this work for 4 years and I have graduated, so pls I would like to ask if there is any chance for me to work in ur company pls 🙏
Yeah
Where is your location...?
Please I'm an electrician,I have learned this work for 4 years and I have graduated, so pls I would like to ask if there is any chance for me to work in ur company pls 🙏
Okay, good to have you here. At the moment, there is no vacancy but will get you informed once any comes out.
Sir I always enjoyed the way you tech ❤ Can I work with you?
Okay, that won't be a problem.
@@jephillsengineeringco.1394 how can I contact you sir
Hi...the wires going to the distribution board from the lighting point...is it the live (common) or the lighting(L1) ?
From the distribution board the live wire goes to the live (common) while the lightening (L1) goes to the lighting point (bulb).
Good job Please am a learner I want to understand more of this work
Just subscribe to the channel and keep following up, we will upload more videos which will help you know it better.
Doing it in the wrong way, no effective contact between the copper tape, earth mat and the earth rod.
The contact is very effective except maybe you're not seeing it very well.
This is wrong
It is actually very wrong for you to say that someone's work is wrong without pointing out the errors.
A considerable expense and waste for bad information.
Be more specific please.
@@jephillsengineeringco.1394 Some exposed copper being used- tempting theft in some places, and electricity follows water- inside or outside. Someone mentioned iron pipe or rebar- steel- which will take a lot electricity to vaporize than the copper tie wire.
Nice work
Thanks
Your bends look sharp. Is it because of the type of wires u use?
It isn't that too sharp oh.. it could be the video
Hi I've been looking at your work a few weeks now, keep it up,
Wow..... Thanks alot sir...!
No cow manua
Could you tell me why are you doing the job alone?
Can you explain the box connection
Ohh lord have mercy 😢
How do you mean..?
Thank you very much
You are welcome
It's not correct work Please check properly
Can you then make the correction so we could learn from ourselves.
Wow, seeing how the walls are caved in to lay the pipes, is that the right way to do? Some you could see the otherside through the walls. I mean why not use an angle grinder??
Frankly speaking, angle grinder is easier and faster to use but it is sometimes not cheap to obtain down here.
It looks sloppy, I am also concerned😅 about how it will look and intergrity of the wall once it it finished
How do you join the conduit pipe
With the use of couplers then we applies pvc gum to hold it firmly.