- Видео 51
- Просмотров 18 709
Instrumentation Channel-Christopher A. Rodil
Филиппины
Добавлен 29 ноя 2012
Instrumentation & Control Engineering - Maintenance & Calibration of Process Instruments, Pressure, Level, Flow, Temperature & Analytical, Dimensional Metrology, Electronics/Electrical
Basic Calibration of Dial Indicator, UUT Mhar Indicator and Standard 716x Test Indicator
Observe the Standard with resolution of 0.0001" and the unit under test with resolution of 0.0005". Range is 0 - 0.1250"
Просмотров: 15
Видео
Basic calibration of Spi-tronic Pro 360 Digital Level Meter using 15""Sine Plate and Guage Blocks
Просмотров 352 месяца назад
Basic calibration of Spi-tronic Pro 360 Digital Level Meter using 15""Sine Plate and Guage Blocks
Part 3 Basic Combined Standard Uncertainty
Просмотров 312 месяца назад
This video explains how to combine the Type A and Type B Uncertainty and explains also how to get sensitivity coefficient and few examples. Please stay tuned to the last part of Uncertainty that covers Expanded Uncertainty, student T-table and how to interpret the Gaussian Curve Bell type shape.
Basic knowledge of Classification of test weights and where to adjust
Просмотров 102 месяца назад
Different types of test weights in this video is Class E2, M1, M2, and M3 (F Class is not available)..This where to find the adjustment cavity when to added or to lessen the target precise weights through high precision balances whether to use special sand, or metal like lead that embedded at the bottom of weight especially in M Class weights.
Basic Adjustment of Torque Wrench before Calibration
Просмотров 183 месяца назад
A simple technique to our calibration technician/engineer to adjust before calibration..It should be physically and visually checks and clean the instrument before proceed to calibration.
Basic Calibration of Caliper (62 Inches)
Просмотров 3710 месяцев назад
This video intended to know basic calibration of huge caliper with the range of 62 Inch with resolution of 0.001 Inches. I demo my in house set point procedure of outside and inside test. Its quite to much hour to take full calibration not included the calculation of Uncertainty..I used standard gauge blocks Grade 0 and wring it specifically to my target. If you have question please comment in ...
Calibration of Micrometer 26-28 Inches Using Starrett Standard Gauge Block
Просмотров 2610 месяцев назад
This video typically calibrating micrometer using gauge block combination. By using in house procedure you can test at calibrate accurately and test the instrument. My apology because i never show the value clearly in the micrometer scale but i guarantee to my viewers that is exactly fall in within tolerance plus/minus 0.001". And I cannot provide the flatness of anvil and spindle value to opti...
Part 2 Basic and Simple Calculation of Uncertainty of Measurement Type B Evaluation
Просмотров 502Год назад
Basic calculation of measurement type B uncertainty in temperature calibration. I have a 7 type B uncertainties here in my data which I analyze before I combine all these uncertainties. Please stay tune to another topic Part 3 and Part 4 of Basic Calculation of Uncertainty.
Calibration of different instrument in controlled room test facility.
Просмотров 80Год назад
This shows different calibration of instrument (pressure transducers abs & gauge, vibration, voltage, current transformer, temperature k type, and many others level, flow, RH, sorry i cannot take videos due to restricted ). This typical happening in every calibration with the team effort of each and coordinated so that it will fasten the work. Thank you comment, share and subscribe in my channel.
Calibration of Pressure Switch Jonhson & Control, 10 psi requirements.
Просмотров 157Год назад
Calibration of Pressure Switch Jonhson & Control, 10 psi requirements.
Calibration of ABB Pressure Transmitter Model 2600T Series 0-160kPa range
Просмотров 759Год назад
Calibration of ABB Pressure Transmitter Model 2600T Series 0-160kPa range
My micro-gridtie inverter set-up design: 4x415Kwp PV input/output 4x240W of combine power.
Просмотров 283Год назад
My micro-gridtie inverter set-up design: 4x415Kwp PV input/output 4x240W of combine power.
Testing of contactor using two pilot lamp and singe phase motor.
Просмотров 60Год назад
Testing of contactor using two pilot lamp and singe phase motor.
Basic testing of thermostat for beginner's , verifying working or defective.
Просмотров 72Год назад
Basic testing of thermostat for beginner's , verifying working or defective.
Basic testing of contactor using digital clampmeter from power contact to NC and NO contacts.
Просмотров 88Год назад
Basic testing of contactor using digital clampmeter from power contact to NC and NO contacts.
Calibration of Rosemount 3051S, zero & span push button, 0-200inH20 range.
Просмотров 527Год назад
Calibration of Rosemount 3051S, zero & span push button, 0-200inH20 range.
Basic testing of low voltage relay, switching NC/NO contact using one analog & one digital VOM.
Просмотров 90Год назад
Basic testing of low voltage relay, switching NC/NO contact using one analog & one digital VOM.
Microgrid type Inverter testing and basic explanation how to set-up.
Просмотров 36Год назад
Microgrid type Inverter testing and basic explanation how to set-up.
Calibration of Flatform Balance Using in Commercial Airlines, 60,000kgs capacity
Просмотров 22Год назад
Calibration of Flatform Balance Using in Commercial Airlines, 60,000kgs capacity
Part 1 Basic and Manual Calculation Uncertainty of Measurement Type A Evaluation
Просмотров 116Год назад
Part 1 Basic and Manual Calculation Uncertainty of Measurement Type A Evaluation
Field calibration with my buddy, simulation of standard voltage. 1-5Vdc in RS485 terminal.
Просмотров 38Год назад
Field calibration with my buddy, simulation of standard voltage. 1-5Vdc in RS485 terminal.
Some Temperature Calibration to be familiarity to our instrument technician.. Happy New Year 2023.
Просмотров 54Год назад
Some Temperature Calibration to be familiarity to our instrument technician.. Happy New Year 2023.
Basic Calibration of Control Valve with I/P transducer using process calibrator 4-20mA input
Просмотров 763Год назад
Basic Calibration of Control Valve with I/P transducer using process calibrator 4-20mA input
+/-3-2-3% accuracy vs. +/- 0.02% accuracy, UUT (UL gauge) vs. Reference Standard Gauge (Fluke).
Просмотров 31Год назад
/-3-2-3% accuracy vs. /- 0.02% accuracy, UUT (UL gauge) vs. Reference Standard Gauge (Fluke).
Calibration of Temperature Transmitter type J Thermocouple 0-1000F Newport Model MTX-J05
Просмотров 225Год назад
Calibration of Temperature Transmitter type J Thermocouple 0-1000F Newport Model MTX-J05
Calibration of Flow Transmitter Rosemount 1151Non-HART with square root function
Просмотров 2532 года назад
Calibration of Flow Transmitter Rosemount 1151Non-HART with square root function
Calibration of Pressure Transmitter Rosemount 1151 Non-Hart using Wallace & Tiernan and Fluke 87V
Просмотров 3,7 тыс.2 года назад
Calibration of Pressure Transmitter Rosemount 1151 Non-Hart using Wallace & Tiernan and Fluke 87V
Temperature Controller Panasonic KT4 Config & Calibration using MR9270S+
Просмотров 6812 года назад
Temperature Controller Panasonic KT4 Config & Calibration using MR9270S
Calibration & Configuration of ANLY AT-702 Temperature Controller
Просмотров 9322 года назад
Calibration & Configuration of ANLY AT-702 Temperature Controller
Pwede paturo ng seting ng omron E5CZ
❤❤❤
Greet brod. very informative video. thank you for sharing.
Salamat po sa panonood abangan po yung last part Part 4 Expanded Uncertainty, DOF and Gaussian Curve interpretation..🙂
Pls I love you videos even though I don't understand most of what you are saying....can do some of the videos in English pls
Wow. Never knew they came this big
Good day Sir, accurate naman reading ni AT502 at sa temp gauge namin (10C kay AT502, 9.5C kay temp gauge) pero 150C ang narereflect na value sa SCADA. Ano po kaya possible na troubleshoot para rito?
Salamat po sa pagcomment sir, kung tama po yung value reading sa temp indicator at kumukuha lng signal sa temp indicator, kailangan i simulate po yung signal niyan para ma fine tune/trim nio papunta sa scada..kuha klng ng signal generator po
Good day sir, tanong ko lang,sir, nde kasi ng eensrgize ung contactor electric oven namin, ano kaya ang pwedeng sira ?
Hello sir magandang araw, paki check yung mga connection if tightly enough maaring loose kaya d maka contact ang coil ng contactor. Thanks for comment po.
Sir itong pneumatic calibrator mu inches H2O paano kung mmH2O pde din ba itong calibrator na ito sir
Thanks for comment yes pede din yan gamitin..gagamit k nga lng ng conversion po.
Boss nagamit kana ng Hart communicator? 475?
@@DennisGutierrez-es7xk Hello sir, hindi po ako nagamit ng Hart 475 jan..manually ko lang po ito ginawa zero and span button..incase wala kang HART Communicator pede naman basta maginject klng ng right pressure n kailangan sa process o yung kailangan mo using standard pressure calibrator.
Boss wala b diagram yan para sa koneksyun
drive.google.com/file/d/100wR3xKV4C0GrDIolUa1_wTy3qv_wQKP/view?usp=drivesdk Sir paumanhin po at medyo busy sa work please see attached file. Salamat. Kung may Qusetion po please remind me. Salamat sa panonood ng video.
@@instrumentmaintenance-Rodil78 sir yung cable na green na naka kabit sa transmitter papunta sa decade box normal ba na cable yun kahit anu cable ba pde or rtd cable yan
@@instrumentmaintenance-Rodil78 saka pala sir itong transmmitter na ginamit sa video na to ito pala ay hart built in kala ko ndi kasi ndi nakita sa nameplate na hart ito salamat sir
Generic po yung diagram ko..nilagyan ko lng ng hart if my hart yung transmitter..pede naman tanggalin yung hart sa diagram..
Pede basta tight o mahigpit ang mga bawat terminals.. or mas maganda talaga instrument cable.
Boss tanong ko lng kapag umiinit yang relay nayan during operation kasi pinapagana siya ng sensor anu boss ang dahilan nyan kapag madaling uminit yung relay salamat boss
Maraming salamat sa comment sir nelson.. Madaming dahilan po either loose contact (madumi, coroded,) or mataas ang dumadaloy n amperahe kaya nainit...or try to compare baka normal naman ang init usually kase coil po siya..
Hello from Canada 🇨🇦 We got a motor like this that have a oil failure in a University. Your video help us to understand the calibration, 100x thanks mister.
Thank you for watching sir...I hope I can contribute through my simple videos to troubleshoot instrument like the one that you watch. Keep it up. Many thanks again. 👍👍👍
give him Canada Work visa.
@@abdulrehmanakram.3030 I am not Immigration Canada 🇨🇦. Lol
gandang paliwanag sir salamat sa video mo.
Maraming salamat po sa comment..humingi ako ng paumanhin d kagandahan ang video ko d2.. abangan po ang Part 3...👍
@@instrumentmaintenance-Rodil78 Okay lang yun sir malaking tulong tong video mo para maintindihan yang mga measurements of uncertainty. antay ako sa part 3
1151GP7S22 analog or hart or penumatic transmitter ??? i am from indonesia
Thank you for commenting. Its analog yes its pressure transmitter.. non-hart transmitter..
😭 'Promo sm'
Diagram master?
hello sir, mg post po ako ng diagram nito.. salamat po sa panonood.
Dami mo n subscriber😅
opo sir para sa ka technician at ka engineer. 😊
Sir pwedi ba i Calibrate yung Thermocouple at PT100RTD?
magandand tanong po ito sir rey. Opo kinacalibrate din po siya..thermocouple with respect to mV to temperature ITS-90, and PT100 resistance to temperature. Makikita mo dito po yung kanilang slope or curve base sa performance ng mga sensor na ito kung proper po ang calibration nito..salamat po sa comment.
@@instrumentmaintenance-Rodil78 thank you sa reply sir! asahan q po ang video nyo on how to calibrate thermocouples&RTD. more power sir!
Anong training center to sir?
Mechatronics Technologies Corporation po sir sa Quezon City..
Nice❤🎉
NagCalibrate din ako ng mga FLUKESMULTITESTER LAHAT NG FLUKES MAY PANGCALIBRATE SA METER NAMAN AMMETER VOLMETER PYROMETER RPM SA PRESSURE SW. Relief Valves instrument ng ship mga gamit ay pressure Calibrator Bmx mc 5 at Latest Flukes Expierence lang sir 9 years saABU DHABI SHIP BUILDING CALIBRATION PACENCIA NA SIR NAMISS KUNA WORK KO SA NAPANOOD KO ANG VIDEO MO SALAMAT PO
same here sir I miss my work sa maintenance and I love to trouble shoot in instrumentation like sa mga big industrial plant..user din ako ng beamex software cmx and mc5 and mc6..thanks for sharing sir. 👍
Ui..ayos🎉😍
❤️
boss sana po makita din po mga wiring connection sam siya nyu pinag kukuha ng connection.kahit na malilit na time lang po mabigyan siya ng tume.salamatvpo
Hello sir cge po ibahagi ko po ang simple wiring diagram nito.. salamat sa comment po.
Superbbbb video paaare But y no English paare😢
Hello I will work for it to have a subtitle please keep in touch. 👍
Superb videooo paare... Why not English pareee😢
I will work for it to have a subtitle please keep in touch.
English subtitles please
06o1q11m
Thank you Po Sir
You're welcome po.
❤
nice idol dagdag kaalaman uli..
My limeter ba sir or naka net metering.? salamat.
opo sir may limiter po d ko muna kinabit under monitoring ko p itong set up ko.. paumanhin sa late reply..
Any videos in English? Good content but I wish I could understand
Thanks for watching KingAl, I will make subtitle of each of my content so the others will understand. Keep in touch.
@@instrumentmaintenance-Rodil78 thank you so much definitely appreciate it. Will stay tuned
Galing!👏
👏🤗👌
Pressure transmitter😏
Wow..galing!!👌👍