suriva
suriva
  • Видео 28
  • Просмотров 228 007
Underground WW2 Nazi Factory - Richard I. (Leitmeritz)
Brief exploration of former WW2 underground nazi factory Richard I. in Leitmeritz (Sudetenland) almost 4 years after propper seal-up of remaining entrances (double steel door, PIR sensors, cameras, etc.)
_______________________________
Just a quick reminder this place is literally falling apart hence dangerous. Besides the other parts of the former mine complex (Richard II. and Richrad III.) are used as Nuclear Waste Storage Facility tho heavily guarded 24/7/365(6) by state authorities (not worth messing with).
_______________________________
If you are interested in photographs from this place let me know. I might upload them on my patreon page. Thanks for watching !!! (Support for more)
___...
Просмотров: 317

Видео

1970s USR292 all-relay PBX telephone switch to PSTN testline call (rotary dialed)
Просмотров 1734 месяца назад
1970s USR292 all-relay PBX telephone switch to PSTN testline call (rotary dialed)
[ASMR] 60+ Minutes Of 1000 kVA Electric Transformer Humming at 50 Hz | No Talking
Просмотров 21 тыс.Год назад
This is a ASMR video of a 1000 kVA medium voltage power transformer peacefully humming at 50 Hz grid frequency. No voiceover. Actual noise slightly varies with the load. Weird relaxation, meditation, learning, sleeping, studying background sounds... Thanks for watching. This footage was shot on a gopro. Please do leave a like, comment, suggestion, hate speech or whatever. You are free to share ...
Holiday projects: Bringing my ГАБ-1-O/230 soviet gasoline generator back to life
Просмотров 66Год назад
Holiday projects: Bringing my soviet ГАБ-1-O/230 gasoline generator back to life. This little beast should be EMP proof and it can power a 600W compressor like nothing.. The problem is not the compressor power which is obviously less than the generator capacity but the locked-rotor current during start-up of the motor. None of todays commercial grade portable generators this size (1kW) would ha...
Last Crossbar Telephone Switch (Central Office) In The 2022 PSTN (TESLA UK11 PBX)
Просмотров 15 тыс.Год назад
Probably one of the last crossbar telephone switches this size in the public switched telephone network still in operation as of december 2022. This system is a part of a fairly large installation of private branch automatic exchange (central office) with 800 subscriber lines and 96 trunks. Installed in early 1980s this switch is capable of direct inward dialling, automatic and semiautomatic tr...
Telephone Intercept Recordings from mid 1990s - Lost & Found Tapes (US, CA, UK, ES, JP, CS, IL)
Просмотров 1,6 тыс.2 года назад
I recently found a tape with telephone intercept recordings and other various messages. It was made probably around 1995-96 since there are clearly recorded 2600Hz wire trunks, drum announcement machines, crossbar tandems and step-by-step local offices. Unfortunately the dialing part of the calls is completely ommited to save (in those days not really cheap) tapes. Here are some of the best sam...
SUPER SAIYAN POWER | ep.2 | 2MVA ALTERNATOR SHORT CIRCUIT ARC FLASH ON 400V BUS BARS
Просмотров 6832 года назад
SUPER SAIYAN POWER | ep.2 | 2MVA ALTERNATOR SHORT CIRCUIT ARC FLASH ON 400V BUS BARS Burning arc flash on 400V bus bars after short circuit initiated with piece of 0,2mm copper wire. The current peak was about 7,5kA and arc kept burning on "carbonized" isloator until the current was interrupted by a fuse. Voltage and current oscillogram at the end of the video. No stunts or illegal activities a...
SUPER SAIYAN POWER | ep.1 | DESTROYING MODULAR CIRCUIT BREAKER WITH 2 MVA GENSET
Просмотров 1,2 тыс.3 года назад
SUPER SAIYAN POWER | ep.1 | DESTROYING MODULAR CIRCUIT BREAKER WITH 2 MVA GENSET Frying a modular (miniature) circuit breaker (MCB) with currents exceeding its short circuit withstand capacity. The power source was a 2MVA 3x400/230V synchronous generator. The current peak was about 7,5kA while the MCB was rated at 4,5kA. Voltage and current oscillogram at the end of the video. No stunts or ille...
[ASMR] 2000 kVA Synchronous Generator Start-up and Spin-down | 10 Minutes | No Talking
Просмотров 1,6 тыс.3 года назад
This is a hardcore ASMR video of a 2 MVA generator of a testing faciliy (synchronous alternator) starting up and then spinning down to stop. No voice over or talking. Weird sounds not suitable for anything.. Have look at my other vids on the channel with high power stuff. Thanks for watching. This footage was shot on an iphone and gopro. Please do leave a like, comment, suggestion, hate speech ...
[ASMR] 45+ Minutes Of 16 MVA Electric Transformer Humming at 50 Hz | No Talking
Просмотров 16 тыс.4 года назад
This is a ASMR video of a 16 MVA power transformer at 110 kV substation. No voiceover or talking. Actual noise is accomplished by random village background noises like singing birds, passing cars and children playing. Weird relaxation, meditation, learning, studying background sounds. Name plate parameters: 16MVA Yy(d) 110kV - 8x2% / 6.3kV / (6.3kV) ONAF Thanks for watching. This POV footage wa...
TO THE POWER OF SPOON | ep.3 | BUS SIMULATOR IRL
Просмотров 8364 года назад
To The Power Of Spoon - Episode III. - Bus Simulator In Real Life aka. Why Would You Ride A Bus When You Can Drive It This video is inspired by _thelittlenuisance's quote "why would you take a bus when you can ride it". In this episode we are showing how to drive an Iveco Urbanway 12M bus. It is an urban bus for public transportation with 6-cylinder diesel 210kW engine, 31 seats and 94 passenge...
SHELTER EQUIPMENT | DIY NIGHT VISION INFRARED CAMERA
Просмотров 3294 года назад
Shelter, Doomsday and Exploration Equipment - DIY Night vision IR camera modification This is a video footage about the modification I did to my old digital CCD compact camera SONY CYBER-SHOT. No way I am promoting any products, services and/or encourage anyone to do anything. No illegal activities or forbidden stuff are shown in this video. The infrared optical filter is physically removed fro...
RANDOM BANDO | ep.3 | THE LAST DAYS | POV EXPLORATION VIDEO
Просмотров 3875 лет назад
Random 'bando - Episode III. - The last days (exploration video) In this episode of Random 'bando I enter the abandoned building that is soon to be demolished on literally last weekend before the site was handled to demolishing company and is guarded since than. The footage was created for preservation of industrial heritage. I did not vandalize, broke or steal anything. Rather long video shows...
SHELTER EQUIPMENT | VOLTAGE DETECTORS IN REAL LIFE
Просмотров 4075 лет назад
Shelter, Doomsday and Exploration Equipment - Voltage Detectors - IRL This is a random video footage about VOLTAGE DETECTORS cut from everyday real life experiences. No way I am promoting any products, services and/or encourage anyone to do anything. No stunts or illegal activities are shown in this video. Voltage Detectors presented in this video are from e-bay and European online shops: - AMP...
[ASMR] 30+ Minutes Of 1600 kVA Electric Transformer Humming at 50 Hz | No Talking
Просмотров 120 тыс.5 лет назад
This is a ASMR video of a 1600 kVA medium voltage power transformer peacefully humming at 50 Hz grid frequency. No voiceover. Actual noise varies with power load and current higher harmonics. Weird relaxation, meditation, learning, studying background sounds. Thanks for watching. This POV footage was shot on iphone and gopro as a VOD. Please do leave a like, comment, suggestion, hate speech or ...
IONIZING RADIATION EXPOSURE DURING COMMERCIAL DAY FLIGHT FROM BCN TO VIE | RADEX ONE
Просмотров 4035 лет назад
IONIZING RADIATION EXPOSURE DURING COMMERCIAL DAY FLIGHT FROM BCN TO VIE | RADEX ONE
IONIZING RADIATION EXPOSURE DURING COMMERCIAL NIGHT FLIGHT FROM BCN TO VIE | RADEX ONE
Просмотров 3485 лет назад
IONIZING RADIATION EXPOSURE DURING COMMERCIAL NIGHT FLIGHT FROM BCN TO VIE | RADEX ONE
RANDOM BANDO | ep.2 | THE NIGHTSHIFT | POV EXPLORATION VIDEO
Просмотров 8115 лет назад
RANDOM BANDO | ep.2 | THE NIGHTSHIFT | POV EXPLORATION VIDEO
ELEVATORS EXPLORED | pt.3 | GEARLESS ELEVATOR | ECODISC
Просмотров 27 тыс.5 лет назад
ELEVATORS EXPLORED | pt.3 | GEARLESS ELEVATOR | ECODISC
ELEVATORS EXPLORED | pt.1 | TRACTION ELEVATOR | TRANSPORTA
Просмотров 4,8 тыс.5 лет назад
ELEVATORS EXPLORED | pt.1 | TRACTION ELEVATOR | TRANSPORTA
ELEVATORS EXPLORED | pt.2 | HYDRAULIC ELEVATOR | CAR SURFING
Просмотров 10 тыс.5 лет назад
ELEVATORS EXPLORED | pt.2 | HYDRAULIC ELEVATOR | CAR SURFING
RANDOM BANDO | ep.1 | THE UNDERGROUND | POV EXPLORATION VIDEO
Просмотров 1505 лет назад
RANDOM BANDO | ep.1 | THE UNDERGROUND | POV EXPLORATION VIDEO
SHELTER EQUIPMENT | pt.4 | RADIOMETER RBGT-62 | QUICK REVIEW | OPERATION
Просмотров 2305 лет назад
SHELTER EQUIPMENT | pt.4 | RADIOMETER RBGT-62 | QUICK REVIEW | OPERATION
SHELTER EQUIPMENT | pt.3 | RADIOMETER DP-5V (ДП-5В) | QUICK REVIEW | OPERATION
Просмотров 6285 лет назад
SHELTER EQUIPMENT | pt.3 | RADIOMETER DP-5V (ДП-5В) | QUICK REVIEW | OPERATION
SHELTER EQUIPMENT | pt.2 | DOSIMETER SET DP-24 (ДП-24) DKP-50A (ДКП-50А) | QUICK REVIEW | OPERATION
Просмотров 5695 лет назад
SHELTER EQUIPMENT | pt.2 | DOSIMETER SET DP-24 (ДП-24) DKP-50A (ДКП-50А) | QUICK REVIEW | OPERATION
SHELTER EQUIPMENT | pt.1 | DIESEL GENERATORS | TEST START
Просмотров 4835 лет назад
SHELTER EQUIPMENT | pt.1 | DIESEL GENERATORS | TEST START
TO THE POWER OF SPOON | ep.2 | TRIBUTE TO SHIEY
Просмотров 2,3 тыс.6 лет назад
TO THE POWER OF SPOON | ep.2 | TRIBUTE TO SHIEY
TO THE POWER OF SPOON | ep.1 | TRIBUTE TO DESMOND
Просмотров 1,1 тыс.6 лет назад
TO THE POWER OF SPOON | ep.1 | TRIBUTE TO DESMOND

Комментарии

  • @felixfriedlander4127
    @felixfriedlander4127 9 дней назад

    8:36 is an Australian (Telstra) recording. (this wording is still in use, in fact I think this very recording is still in use in some places)

  • @JoanndavidPatron
    @JoanndavidPatron Месяц назад

    4:46

  • @sxsphil
    @sxsphil Месяц назад

    Any new update with this. Would like to see a more detailed video, not a panoramic view

  • @venos2175
    @venos2175 Месяц назад

    This man has big balls💀💀

  • @michal_king478
    @michal_king478 Месяц назад

    I remember those days of sitting my whole night in front of a large switchboards full of contactors at a local mall. It was super loud

  • @TheShadowBrokers1
    @TheShadowBrokers1 Месяц назад

    Cool

  • @agn98
    @agn98 Месяц назад

    1600kVA Electric Transformer Hum :Frequencies Sonic Visualizer : 50 Hz 100Hz 200 Hz 250 Hz 300 Hz... Best viewed with 1080p , the lower pitch 50 Hz is a bit fuzzy ruclips.net/video/91AkTqw8I90/видео.htmlsi=NsI5zrAyf0qNyNfL

  • @Fr0zen14
    @Fr0zen14 2 месяца назад

    I work on a pstn switch that's been online longer than i have been alive..

  • @SA-gf3th
    @SA-gf3th 2 месяца назад

    Its using 5:14 40kva and it's a 1600Kva? That's like too little work for such a huge transformer, wasting too much inductive current at primary.

  • @theorovoicemailgreetingus5907
    @theorovoicemailgreetingus5907 2 месяца назад

    Only feminine-voiced recordings

  • @theorovoicemailgreetingus5907
    @theorovoicemailgreetingus5907 2 месяца назад

    SIT Tones are creepy to play in the dark.

  • @theorovoicemailgreetingus5907
    @theorovoicemailgreetingus5907 2 месяца назад

    Pat Fleet

  • @EmergencyChannel69420
    @EmergencyChannel69420 3 месяца назад

    As a British person I appreciate that you've made a 50 Hz hum available

  • @jaminova_1969
    @jaminova_1969 4 месяца назад

    I like the aesthetics of that telephone room. It has a very 80's feel to it!

  • @airtondalmagro4732
    @airtondalmagro4732 4 месяца назад

    Trabalhei nas ARF ERICSSON , onde esta este equipamento ?

  • @paulphillips675
    @paulphillips675 4 месяца назад

    I think the camera will make me sea sick if I keep watching!

  • @thecrow2588
    @thecrow2588 4 месяца назад

    Underground tunnels are fun to explore, like

  • @BunnybabuTananki
    @BunnybabuTananki 4 месяца назад

    Super sur. Your videos. Actually, II like transformer humming sounds, please upload me railway gates siren, railway gates, siren videos. At least 1 hour. Thank you so much super your videos, thank you, sir.😊

  • @betzabenaranja5165
    @betzabenaranja5165 4 месяца назад

    fascinating 🥰

  • @thecrow2588
    @thecrow2588 4 месяца назад

    Came for the urbex, stayed for the clicks I guess?

    • @suriva
      @suriva 4 месяца назад

      well, thank you. byw I just uploaded an exploration vid

  • @lapub.
    @lapub. 4 месяца назад

    What was the purpose of the factory ?

  • @mxg75
    @mxg75 4 месяца назад

    I’m surprised a switch like this was built in the 80’s, I thought mechanical switches and the requirement for human operators for long distance calls were phased out by then.

    • @lapub.
      @lapub. 4 месяца назад

      They were still made at early 80's they were already "computerise" the switching matrix only where still mechanical. The switch evolution was mechanic "brain" and mechanic spatial "connexion matrix" electronic"brain" and mechanic spatial "connexion matrix" Computer "brain" and mechanic spatial "connexion matrix" Computer "brain" and analog electronic spatial "connexion matrix" Computer "brain" and digital "connexion matrix" The digital connexion matrix was designed in the early 70's since then the voice was digitized and send as packet just the same way it's done with Ethernet packets. but as you can imagine it cost a lot at the time; even if far more reliable (no more degradation in transmission) and huge multiplexing capability. So crossbars was still made even if already outdated they work well., just like you can still find DSL modem as you don't have fiber everywhere !

    • @suriva
      @suriva 4 месяца назад

      exactly. there were common program controlled analog switches in late 1960s (#1ESS) while "brute force motor operated mechanical" panel switches form 1930s were still in operation well into 1970s ... step-by-step COs like #1 or 355 invented in early 1900s were in operation into 2000s... EWSD, 1000 S12, DMS10, 100 from 1980s could be still found here and there today.... and human operators were absolutelly common even after 2000s its just matter of last decade that companies dont wnat you to speak with real people.... "if you want an operator to hang up on you press star now"

  • @joeMama-tp8oj
    @joeMama-tp8oj 4 месяца назад

    So cool!

  • @user-vl5ye1sn3v
    @user-vl5ye1sn3v 4 месяца назад

    This video was either filmed after work hours or the employees are not making many phone calls......

    • @suriva
      @suriva 4 месяца назад

      Many of the extensions are already migrated to VoIP. There are only 6 incoming trunks left and like 10 outgoing. Was filmed in the evening or on holidays, idk, I usually work late.

  • @alouisschafer7212
    @alouisschafer7212 4 месяца назад

    Gonna be an awesome day when we energize 3 of those transformers (very similar type 10KV to 400V 1250kva rated) at the new main transformer and power distribution building we are setting up for a hospital complex. State of the art Siemens Sivacon S8 with integrated power monitoring and metering on the low voltage side. Some feeds are rated up to 1000 amps and we paralleled multipe 4x300mm2 aluminium cables to make that possible. Each transformer is rated at around 1300 amps per phase. Big stuff. The building that houses everything is set up very differently that this installation here. Each transformer has its own separate cell, fireproofed from each other and the HV side switchgear needed to have its own room, also fireproofed aswell as the Sivacon S8 whose room is also fireproofed. A fire detection system is also in place and I am a bit surprised they didnt go for an automatic CO2 fire suppression system aswell. We have a couple installations where that was specified. I believe the need for a fire suppression system is dependent on the accessibility of the electrical rooms and how a fire would affect the building.

    • @suriva
      @suriva 4 месяца назад

      yes there are many ways how to waste money.... this instalation has 4 diesel gensets so the utility network and transforming station aint "primary source" for the consideration of reliability...

  • @Spookyb329
    @Spookyb329 5 месяцев назад

    Amazing that this was still in use, I started in Telecoms in 2003 and learnt about Crossbar (theory not maintenance) and even then it was nearly 10 years since the last crossbar exchange was closed in England! (1994)

    • @suriva
      @suriva 4 месяца назад

      isnt it amazing ? its still working btw... yes we got rid of most crossbars in mid to late 90s too

  • @lucaspod
    @lucaspod 5 месяцев назад

    I can't believe this was installed in the 1980s. Where I live , in that time frame there would have been an SL1 fully digital system instead

    • @suriva
      @suriva 4 месяца назад

      wait wait wait... there were few Nortel SL1s in 80s and literally tons of Crossbars and even Steps back then. and yes there was a fully digital UE installed in the same time period (with size of a fridge) but was not EMP proof...

  • @agn98
    @agn98 5 месяцев назад

    Main peaks are at 100 ,200 ,300 and 400Hz. Secondary peaks at 4,76,150.. Hz

    • @suriva
      @suriva 4 месяца назад

      yk harmonics.... the fundamental is 50 Hz... btw even harmonics superimpose to DC component and should not be there... tho the 3rd 150 Hz component may be significant cause neutral wire load...

  • @jbsimmons54
    @jbsimmons54 5 месяцев назад

    I worked for GTE in the USA. Have to say that the outer frame panels are SUPERB! We didn't put up all those frame panels on ours and everything was directly accessible without removing anything. That said, the later computerized switching systems had enclosed frames, raised computer room floors, and air conditioning.

    • @suriva
      @suriva 4 месяца назад

      Thank you for your interest sir. Those are the little "cultural" diffrences.. basicly we had same switching systems like #1 and 355A step, #1 and #5 crossbar, crossbar and 4A tandems, even clones of all-relay switches like CX100, CX1000, later 1ESS/4ESS based topology like E10, DMS10/100, S12, ESWD in late 90s/early 00s up to softswitches and VoIP which I do not consider interesting anymore..

  • @XFile222
    @XFile222 5 месяцев назад

    Discurso de odio?¿ No, no me viene ninguno ahora. A si que me drogaron hasta el borde de la muerte cuenta?

  • @matbr6949
    @matbr6949 5 месяцев назад

    Those top-down Nixies are super neat!

    • @suriva
      @suriva 4 месяца назад

      imagine caller line identification in 1980s....

  • @eclairaigepublique35
    @eclairaigepublique35 6 месяцев назад

    backroom

    • @suriva
      @suriva 4 месяца назад

      yeahh I live in backrooms... somehow I noclipped there

  • @hauptuhrdotnetblog6700
    @hauptuhrdotnetblog6700 6 месяцев назад

    Thank you so much for doing this. I hope you are able to save the switch and the operator positions.

    • @suriva
      @suriva 4 месяца назад

      yes Im doing my best to save it all.. hope I could mange to rent the space so I dont have to remove it.... but its like hell of a dough yk

    • @hauptuhrdotnetblog6700
      @hauptuhrdotnetblog6700 4 месяца назад

      @@suriva renting the space while you get your plans together is good but obviously not a long term solution. One step at a time. You’ll figure it out.

  • @spootnewton7121
    @spootnewton7121 6 месяцев назад

    From back when telephones were used for serving humanity instead of tracking and controlling us.

  • @RealVaderInvader
    @RealVaderInvader 6 месяцев назад

    the proper way to tune a g string

  • @federicofromvenice8205
    @federicofromvenice8205 6 месяцев назад

    Assuming power factor =1 the power in Kw is 1.000 = 1 Mw, isn'it? In wich case the transformer has different power factor?

    • @suriva
      @suriva 4 месяца назад

      non linear loads like SMPS have capacitive power factor, on the other hand motor drives are inductive.. nothing except a pure resistive load (classic light bulb) has power factor of 1... speaking of higher harmonics you also have to distingusih between Displacement Power Factor (1. hramonic only) and True Power Factor (all other harmonics) which aint the same in case of non linear loads like power electronics and saturated magnetic circuits....

    • @federicofromvenice8205
      @federicofromvenice8205 4 месяца назад

      @@suriva , thank you very much.

  • @OksanaTverdokhlebova
    @OksanaTverdokhlebova 6 месяцев назад

    5:30 Sounds like Рокот

  • @schaltnetzteil495
    @schaltnetzteil495 7 месяцев назад

    I personally like 50Hz transformer buzzing better than 60Hz transformer buzzing because well... I live in Europe where we have 50Hz mains.

  • @SM8150-AC
    @SM8150-AC 7 месяцев назад

    SNCF class Z 20500 at 25 kilovolts have a 100 Hz humming (certains have a 50 one, the 20510) but i prefer the continuous 1.5 kV than the AC 25 kV one for these trainsets.

  • @SM8150-AC
    @SM8150-AC 7 месяцев назад

    My phone's refresh rate cycles at 50.84 Hz :( Also that's good when you're using 25 fps. Also, the frame rate and the humming make a good sync, sound like a four cylinder engine to me.

  • @versedbridge4007
    @versedbridge4007 8 месяцев назад

    Try humming with this playing, it's quite a trip.

  • @ClockworkJohn92
    @ClockworkJohn92 8 месяцев назад

    Hodně zajímavé místo. Chci se zeptat jako laik... ta příruba směrem ke stropu je asi výfuk z agregátu co pohání generátor??? A sání vzduchu do motoru je podle filtrů je jenom z místnosti ? To jsou ty místnosti nějak speciálně ventilované pře filtraci vzduchu ?

    • @suriva
      @suriva 8 месяцев назад

      jsou tam vzudchovody cca. 2x2m pro chlazeni, sani motoru samotniho je z mistnosti, vejfuk jak rikate

  • @janpesak8272
    @janpesak8272 9 месяцев назад

    Zdravím, nějaký posun? Odhaduji také že bude někde CZ/SK, protože tam vidím i STP od inomy se mihnout :-) mám taktéž UK11, pokud se povedlo a chtěl by jste s něčím pomoct či ji propojit s IP světem, je možno :-)

    • @suriva
      @suriva 8 месяцев назад

      dobry den, jsme stale v provozu, postupna migrace na VOIP, ustrednu celou zachovam, snazim sa pronajmou prostory, kdyz ne, odsehuji jinde, muzu mit na Vas nejaky kontakt ?

  • @gabrielwaltermalter
    @gabrielwaltermalter 9 месяцев назад

    Lain Referenzen

  • @WhitfieldProductionsTV
    @WhitfieldProductionsTV 10 месяцев назад

    well would of been more fun if this would of been narrated by you and not a machine.

    • @suriva
      @suriva 8 месяцев назад

      next episodes..

  • @Journey_to_who_knows
    @Journey_to_who_knows 10 месяцев назад

    Sounds like my noise cancelling headphones when there’s no sound playing

  • @georgen.8027
    @georgen.8027 10 месяцев назад

    This is in CZ?

  • @spotterinc.engineering5207
    @spotterinc.engineering5207 10 месяцев назад

    This looks like an LM Ericsson PABX. If true, please advise the model number. I worked on many similar Ericsson PABX's in the 1970's

    • @suriva
      @suriva 8 месяцев назад

      nah, its eastern block "copy", been produced since late 60' to mid. 80'

  • @lcarliner
    @lcarliner 10 месяцев назад

    perhaps the Connections Museum in Seattle, Washington, be contacted as they very well may be interested into its collection

    • @suriva
      @suriva 8 месяцев назад

      Im a big fan of connections museum however I will preserve this switch in fully working condition my self

  • @spacetrucker2196
    @spacetrucker2196 11 месяцев назад

    Where can I get a set up like this?

    • @suriva
      @suriva 4 месяца назад

      try amazon or ebay, if not successfull try government agencies and nuclear facilities (btw. you can get anything in Ukraine nowadays)