John Novak TR2FD
John Novak TR2FD
  • Видео 51
  • Просмотров 69 832
Vortex tie back Test.
Using the Vortex as an anchor frame for a ground controlled skate block. Testing tie back of the Vortex. Vortex being used as a high directional. Leg movement is from the raising of the load. A COD pulley was placed at the head of the Vortex and was setup as a skate block down to a Petzl MAESTRO that was used as the lowering device and progressive capture. The tie back of the Vortex was first done with an AZTEK and then with a single 1/2 static rope and 8mm prusik. Both test used a load cell between the tie back and the anchor. The load was 195 pounds. The max loading was 236 pounds and this was during the raising of the load using a 3:1 MA.
Просмотров: 34

Видео

Friction loss for 2 1/2 inch and 1 3/4 inch hose
Просмотров 4597 месяцев назад
Basic friction loss calculations for 2 1/2 inch and 1 3/4 inch hand lines. Video made for students to view prior to attending pump training at the academy.
Nozzle Pressures and Flows for Pump Operations
Просмотров 2007 месяцев назад
Short video for my pump school students to prepare them for class. Briefly speaking about common nozzles and nozzle pressures.
Fire Officer's Role in the Budget Process, Fire Officer Level 2 Training
Просмотров 11110 месяцев назад
My channel provides training videos for may aspects of firefighter training including pump operations, building construction for fire officers and other firefighter training videos.
Fire Officer Communications
Просмотров 5010 месяцев назад
My channel provides training videos for may aspects of firefighter training including pump operations, building construction for fire officers and other firefighter training videos.
Fire Officer Performance Evaluations
Просмотров 5910 месяцев назад
My channel provides training videos for may aspects of firefighter training including pump operations, building construction for fire officers and other firefighter training videos.
Clove Hitch on Stokes Basket
Просмотров 273Год назад
This short video was done to show how I tie clove hitches around the top of a stokes basket for a low angle lower or raise. Not shown is the finished loop using a bowline. This is just one option to use, there are others. You need to find something that works for your team.
Bowline On A Coil
Просмотров 1,7 тыс.Год назад
Short video to demonstrate tying a bowline on a coil around the head of a litter.
LDH Large Diameter Hose Limitations
Просмотров 255Год назад
This video is intended to illustrate some disadvantages and issues associated with using LDH or Large Diameter supply hose unsupported connected to a hydrant. I go over the basic friction loss formula to work backwards to determine the approximate available GPM based on the pressure in the water main and the friction loss in the 5-inch supply hose.
Commercial Building Fire Type 2
Просмотров 1,2 тыс.Год назад
Fire in commercial building Type 2 construction
Fire Department Company Officer Level 1 "Safety and Risk Management"
Просмотров 4132 года назад
Jones & Bartlett FDCO-1 Chapter 8. This video is intended to supplement the fire officer level 1 training program as presented in the Jones & Bartlett text. Video was made specifically for my academy class.
Fire Department Company Officer Level 1 "Command of Initial Emergency Operations"
Просмотров 3102 года назад
Jones & Bartlett FDCO-1 Chapter 7. This video is intended to supplement the fire officer level 1 training program as presented in the Jones & Bartlett text. Video was made specifically for my academy class.
Fire Department Company Officer Level 1 "Fire Department Administration"
Просмотров 6252 года назад
Fire Department Company Officer Level 1 "Fire Department Administration"
Fire Department Company Officer Level 1 "Community Risk Reduction"
Просмотров 8602 года назад
Fire Department Company Officer Level 1 "Community Risk Reduction"
Fire Department Company Officer Level 1 "Leading A Team"
Просмотров 4112 года назад
Fire Department Company Officer Level 1 "Leading A Team"
Fire Department Company Officer Level 1 "Understanding Leadership and Management Theories"
Просмотров 6682 года назад
Fire Department Company Officer Level 1 "Understanding Leadership and Management Theories"
Fire Department Company Officer Level 1 "Fire Officer as a Company Supervisor"
Просмотров 1 тыс.2 года назад
Fire Department Company Officer Level 1 "Fire Officer as a Company Supervisor"
Fire Department Company Officer Level 1 "Pre-Incident Planning and Code Enforcement"
Просмотров 4882 года назад
Fire Department Company Officer Level 1 "Pre-Incident Planning and Code Enforcement"
Parking Garage Fire Alternate view
Просмотров 3442 года назад
Parking Garage Fire Alternate view
Parking Garage Fire
Просмотров 1,4 тыс.2 года назад
Parking Garage Fire
Pump Operations
Просмотров 5312 года назад
Pump Operations
Dual Pumping
Просмотров 5 тыс.3 года назад
Dual Pumping
Pump Operations Lesson #4 Friction Loss 2 1/2 inch Hose
Просмотров 6 тыс.3 года назад
Pump Operations Lesson #4 Friction Loss 2 1/2 inch Hose
Pump Operations Lesson #5 Friction Loss 1 3/4 Inch Hose
Просмотров 4,7 тыс.3 года назад
Pump Operations Lesson #5 Friction Loss 1 3/4 Inch Hose
Pump Operations Lesson #3 (Apparatus Fire Pumps)
Просмотров 2,5 тыс.3 года назад
Pump Operations Lesson #3 (Apparatus Fire Pumps)
Pump Operations Lesson #2 Pressure Gauges
Просмотров 1,1 тыс.3 года назад
Pump Operations Lesson #2 Pressure Gauges
Pump Operations Lesson #1 (Nozzles, Flows, Nozzle Pressures etc.)
Просмотров 9713 года назад
Pump Operations Lesson #1 (Nozzles, Flows, Nozzle Pressures etc.)
B-17 Flight 2 of 2
Просмотров 244 года назад
B-17 Flight 2 of 2
B-17 Flight 1 of 2
Просмотров 224 года назад
B-17 Flight 1 of 2
Technical Rescue Awareness for Fire Officers
Просмотров 5284 года назад
Technical Rescue Awareness for Fire Officers

Комментарии

  • @timpowers225
    @timpowers225 27 дней назад

    Would you use 2 z rigs to get stokes up to victim and then change it over to a lower by just keeping the clutches?

    • @johnnovaktr2fd677
      @johnnovaktr2fd677 26 дней назад

      Yes, we could use two or just one 3:1's or even just a 1:1 to haul the basket up, then change over to a lower.

  • @daddydankmemes6260
    @daddydankmemes6260 3 месяца назад

    Very Boring, so on par for firefighter classroom training. Thanks John.

  • @JasonBatz
    @JasonBatz 7 месяцев назад

    Think you meant 1 1/8

    • @johnnovaktr2fd677
      @johnnovaktr2fd677 7 месяцев назад

      Jason, I believe you are referencing the one nozzle where I said it was a 1 3/16 inch. If that was the case, I did not miss speak. I was referencing a 1 3/16 inch tip for a 2 1/2 inch nozzle. Here is a good article that speaks to the advantage of the 1 3/16 inch nozzle (www.hydrant2nozzle.com/1-316-nozzle) If you were referencing something else could you be more specific so I can make the correction. However, thanks for watching the video.

    • @JasonBatz
      @JasonBatz 7 месяцев назад

      @@johnnovaktr2fd677 Chief, I could have sworn that when I watched the video the other day that your 2.5" example showed a 1.25" tip at 265. All good with 1 3/16 tip idea, we've played with that as well as the 1-1/16 Shupe tip for 2" lines! Thanks for the video.

  • @williammora7077
    @williammora7077 Год назад

    Dual Pumping has been actively used by the San Antonio Fire Department for over 23 years. (Since April 1, 2000) Results in numerous safety and efficiency benefits.

  • @robozoo2
    @robozoo2 Год назад

    Excellent video! I am currently studying for my c16 this is exactly what I was looking for.

  • @NeilM01989
    @NeilM01989 Год назад

    Liked, subscribed and shared your video and channel

  • @KB-dg2gr
    @KB-dg2gr Год назад

    Thank u heros people dont know the work fireman have to do to be ready.

  • @mattd8411
    @mattd8411 Год назад

    Thanks for the video.

  • @joemomma5353
    @joemomma5353 Год назад

    Please tell me there is a second video coming from this fire? Good operation!

    • @johnnovaktr2fd677
      @johnnovaktr2fd677 Год назад

      This is the only dashcam video that the chief gave me. Fire was knocked down and extinguished with the 2 1/2". Some roof deck fire was extinguished with the tower.

  • @gort400
    @gort400 Год назад

    THANK YOU!

  • @Psychiatrick
    @Psychiatrick Год назад

    john Novak TR2FD ... How does water get to the 1,000' level from sea level? Certainly, with gravity, it would take tremendous amount of pressure to pump water to that level. My thought is there would have to be reservoirs at graduated levels to pump water from one reservoir to another. for example, each floor of the World Trade Center was about 1 acre. The demand on water would be such there must have been several direct pumps to satisfy restroom, restaurant and sprinkler needs. I would also like to "think" if you pumped water to the 10th floor reservoir then the 20th floor etc. the weight of the 20th floor could use gravity to service the lower floors. As the holding tanks become depleted they would be refilled not unlike a toilet holding tank. The Roof of the WTC would hold a reservoir with water flowing down under pressure. Sea water is about 1 ton per cubic yard.

  • @dboatube
    @dboatube 2 года назад

    ok.. but why post over an hour of clear air garage for no reason? cut the vid down to just the smoke.

  • @steveroberts9534
    @steveroberts9534 2 года назад

    Why do you suggest shutting down the fire pump once the FDC has been supplied? Is this your department’s SOP?

    • @johnnovaktr2fd677
      @johnnovaktr2fd677 2 года назад

      Steve, the fdc is connected to the system up stream of the fire pump. There is usually a check valve between the fire pump and the distribution side of the system. Once the FD connects to the system we usually pressurize the system at a higher pressure than the fire pump. This would close the check valve and the fire pump would be running at "Churn" (no water flowing). If the fire pump is not set up to shut off if running at churn then possible damage could occur. It is important to know your buildings and systems in your response area.

  • @mysuperintendent9095
    @mysuperintendent9095 2 года назад

    Very good explanations!

  • @davidgorejr2560
    @davidgorejr2560 3 года назад

    Who didn't like the video smh always 1 hater

  • @larrylasich5136
    @larrylasich5136 3 года назад

    Pro tip; attach a 3 inch line from the hydrant to the second Engine to maintain the residual pressure that the hydrant can provide. Re-enforce all hydrants by attaching 2 1/2 Gate Valves.

  • @aletapearce2369
    @aletapearce2369 3 года назад

    This is excellent if you are studying the IBC and want to have an understanding of these systems.