Masonry Institute of Michigan, Inc.
Masonry Institute of Michigan, Inc.
  • Видео 18
  • Просмотров 11 962
Specifying CMUs
This video provides an overview of how to specify compressive strength of concrete masonry units on your project.
Просмотров: 61

Видео

Specifying Mortar for Masonry Construction
Просмотров 91Год назад
This tutorial discusses best practices for specifying mortar for brick and CMU masonry construction. Recommendations from BIA and CMHA are reviewed, and the MIM presents best practices for specifying mortar for projects in Michigan.
Design_Modular Dimensioning
Просмотров 862 года назад
This video discusses the importance of modularity in masonry construction. Several rules are presented to aid designers in identifying modular dimensions which help aid in better jobsite productivity.
Construction_Grout Volume Estimation
Просмотров 1842 года назад
This video shows how to estimate the volume of grout required for CMU wall construction using NCMA TEK -0-04A.
Structural_URM: Partition Design
Просмотров 442 года назад
This video tutorial shows users how to design unreinforced masonry (URM) partition walls based on the Strength Design provisions of the TMS 402/602-16.
Structural_URM: Section Properties
Просмотров 1022 года назад
This video demonstrates how to calculate the net section properties for an ungrouted CMU wall spanning vertically. This video also discusses references and how these values can be used to design unreinforced masonry (URM) walls.
Structural_Masonry Lintels: Flexural Design
Просмотров 1 тыс.2 года назад
This video discusses the TMS 402/602-16 requirements as they relate to the flexural design of masonry lintels. Code provisions are presented through several examples and a discussion of factors that affect the design of masonry lintels.
Masonry Minute - Fire Resistance Ratings of Single Wythe CMU
Просмотров 3503 года назад
In this video, we specifically cover how to calculate the fire resistance rating of a single wythe CMU assembly using the 2018 International Building Code, specifically Section 703 Fire Resistance Ratings
Masonry Minute: Should truss or ladder-type joint reinforcement be used in CMU construction?
Просмотров 1,4 тыс.4 года назад
www.masonryinfo.org/ The two most common types of horizontal joint reinforcement are truss-type and ladder-type. When should each be specified? Listen to this Masonry Minute to see when each is appropriate.
Lintel Design: Principles of Flexure (1 of 4)
Просмотров 5094 года назад
www.masonryinfo.org/ This four part lintel design series focuses on the strength design (SD) provisions contained in Chapter 9 of the TMS 402-16 Building Code Requirements for Masonry Structures. The first part of our series focuses on principles of flexural design by comparing flexural analysis of reinforced concrete members based on ACI 318-14 to the provisions contained in TMS 402-16. Topics...
Masonry Minute: Are you over-designing your CMU lintels?
Просмотров 1 тыс.4 года назад
www.masonryinfo.org/ Did you know that masonry laid in running bond has an innate ability to span around openings? The masonry industry typically refers to this as "arching action", and taking advantage of arching action can allow for much more economical lintel sizes. Instead of designing a lintel for the total superimposed load from floors, roofs, and wall self weight; using arching action al...
Masonry Minute - Are you correctly specifying grout compressive strength on your project?
Просмотров 1574 года назад
www.masonryinfo.org/ The compressive strength of grout has both maximum and minimum values in the TMS 402/602 document as well as in ASTM C476. Make sure you are correctly specifying grout compressive strength in your project plans or specifications.
Masonry Minute: Can you use concrete cylinder molds for grout compressive strength specimens?
Просмотров 3974 года назад
www.masonryinfo.org/ Although commonly used on masonry job sites, this video addresses the use of plastic concrete cylinder molds used for compressive strength testing of grout. ASTM C1019 and NCMA Technical Note 18-08B are referenced to show testing recommendations for grout.
Masonry Minute: Are you correctly specifying masonry compressive strength?
Просмотров 3744 года назад
www.masonryinfo.org/ Masonry compressive strength (f'm) is used in almost every equation in the TMS 402/602 standard. It effects nearly everything; ranging from development length of reinforcement to reinforcement size and spacing. The TMS 602 includes the "Unit Strength Method" which includes a table relating mortar type and compressive strength of concrete masonry units to the compressive str...
Masonry Minute: Maximum Bar Spacing
Просмотров 1424 года назад
www.masonryinfo.org/ Learn the TMS 402/602 requirements for the maximum spacing of vertical reinforcement in masonry wall construction.
A Guide for Placing Control Joints in CMU Tutorial
Просмотров 5 тыс.4 года назад
A Guide for Placing Control Joints in CMU Tutorial
Calculate development length for masonry walls with TMS402-13 and TMS402-16.
Просмотров 5414 года назад
Calculate development length for masonry walls with TMS402-13 and TMS402-16.
Become a Masonry Institute of Michigan (MIM) member today!
Просмотров 1214 года назад
Become a Masonry Institute of Michigan (MIM) member today!

Комментарии

  • @amrhariri1996
    @amrhariri1996 Год назад

    Is there any reference to design unreinforcement masonry walls?

  • @eljinlaquindanum5029
    @eljinlaquindanum5029 Год назад

    Thank you!.,

  • @ahmedotefa8679
    @ahmedotefa8679 Год назад

    Could we construct BCJ for wall from one side with column/stiffener column, and fix the other side by angles, bonding agent and mortar with the other column??

  • @zainsaeed147
    @zainsaeed147 2 года назад

    The grout you mentioned are to be used in masonry units however now a days these have been developed further like mircroete grout that are used for connecting precast reinforced concrete sandwich walls. For those application i think we can still rely on cubes or cylinders

  • @Rayquesto
    @Rayquesto 3 года назад

    Does Arching action also occur in tilt up concrete walls?

  • @keysersoze2337
    @keysersoze2337 3 года назад

    Thank you for the great info,if you dont mind me asking,If the plans indicate 5 feet max grouting,can you keep laying the courses right after grouting or do you have to wait a certain time for the grout to cure? Also do you leave a grout key on a bond beam? Thank you.

    • @masonryinstituteofmichigan9713
      @masonryinstituteofmichigan9713 3 года назад

      The current TMS 602 (Specification for Masonry Structures) has grout pour heights includes in Section 3.5C. Designers and contractors typically limit grout pour heights to 5'-4" which is considered low lift grouting, and you would be permitted to continue laying courses after grouting. NCMA has more information on grouting available here: ncma.org/resource/grouting-concrete-masonry-walls/. Grout keys are covered in Section 3.5F where it states to form grout keys between grout lifts when the first lift is permitted to set prior to placement of the subsequent lift. The specification does state not to form grout keys within beams.

    • @keysersoze2337
      @keysersoze2337 3 года назад

      @@masonryinstituteofmichigan9713 thank you very much