Catalin Design
Catalin Design
  • Видео 100
  • Просмотров 106 698

Видео

How to calculate the energy demand for a industrial application
Просмотров 128Месяц назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
How you can select the proper luminaires for your application?
Просмотров 67Месяц назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
How to check the energy demand for an indoor parking
Просмотров 1562 месяца назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
Emergency lighting for corridors
Просмотров 2203 месяца назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html More info about emergency lighting standard in the video below ruclips.net/video/PbbXUPmUTK4/видео.html
Learn more about types of emergency lighting
Просмотров 2023 месяца назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
How to find more information about luminaires in Dialux evo
Просмотров 1194 месяца назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
How to use the energy demand in Dialux new version 12.1
Просмотров 4645 месяцев назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/3Kpj7BcQAZI/видео.html ruclips.net/video/f6XQkO7JS3c/видео.html
What is new on Dialux evo version 12.1 part II
Просмотров 2936 месяцев назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/vkvRAD1Em4Q/видео.html ruclips.net/video/f6XQkO7JS3c/видео.html
What is new on Dialux evo version 12.1?
Просмотров 3577 месяцев назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
How to draw and edit a space in Dialux
Просмотров 9168 месяцев назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
How to add furniture
Просмотров 1468 месяцев назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
Lighting design for classroom part II
Просмотров 2058 месяцев назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
How to create your own space in Dialux evo
Просмотров 2409 месяцев назад
Learn how to realize a lighting simulation by using Dialux evo ruclips.net/video/f6XQkO7JS3c/видео.html
How to turn ON outdoor lighting
Просмотров 2319 месяцев назад
How to turn ON outdoor lighting
Lighting for an apartment balcony
Просмотров 16410 месяцев назад
Lighting for an apartment balcony
Lighting for an apartment bathroom
Просмотров 24010 месяцев назад
Lighting for an apartment bathroom
Lighting for an apartment bedroom
Просмотров 27410 месяцев назад
Lighting for an apartment bedroom
Lighting for apartment part IV
Просмотров 22411 месяцев назад
Lighting for apartment part IV
Light for apartment part III
Просмотров 15511 месяцев назад
Light for apartment part III
Lighting for apartment part II
Просмотров 24011 месяцев назад
Lighting for apartment part II
Lighting for apartment
Просмотров 507Год назад
Lighting for apartment
Light for galleries part III
Просмотров 207Год назад
Light for galleries part III
Lighting for an outdoor building
Просмотров 256Год назад
Lighting for an outdoor building
Light for galleries part II
Просмотров 162Год назад
Light for galleries part II
Lighting solution for staricase part III
Просмотров 186Год назад
Lighting solution for staricase part III
Light for galleries part I
Просмотров 160Год назад
Light for galleries part I
Light a painting
Просмотров 158Год назад
Light a painting
Lighting design information part II
Просмотров 196Год назад
Lighting design information part II
Lighting design information
Просмотров 209Год назад
Lighting design information

Комментарии

  • @ayaribrahim4914
    @ayaribrahim4914 3 дня назад

    Can you share the reference doc for illuminance class

    • @catalindesigner
      @catalindesigner День назад

      Thanks for your question. By clicking on the following link you will find the programme2014-20.interreg-central.eu/Content.Node/Dynamic-Light/MODULE-4-PublicLightingStandards2-24-10-18.pdfluminance classes for street lighting

  • @thehappinessforyou9965
    @thehappinessforyou9965 19 дней назад

    Why u dont use the calculation object surface to limit the lighting stimulation

    • @catalindesigner
      @catalindesigner 18 дней назад

      Thanks for your question! I could do that without any problems, but I did not consider to add the object surface in this case.

  • @thehappinessforyou9965
    @thehappinessforyou9965 25 дней назад

    Hi Sir. What is the meaning of " In/out ramps ( at night ) " ?

    • @catalindesigner
      @catalindesigner 24 дня назад

      Thanks for your question. The In/out ramps means the enter and exist zones of an indoor parking. From where the car goes in or out. Hope that now is clear.

    • @thehappinessforyou9965
      @thehappinessforyou9965 24 дня назад

      @@catalindesigner Thank Sir !

    • @catalindesigner
      @catalindesigner 23 дня назад

      @@thehappinessforyou9965 you are welcome!

  • @thehappinessforyou9965
    @thehappinessforyou9965 25 дней назад

    Many thanks. Keep going 😍

  • @thehappinessforyou9965
    @thehappinessforyou9965 25 дней назад

    Useful video ! Keep going 😍

  • @thehappinessforyou9965
    @thehappinessforyou9965 Месяц назад

    Thank you. In different way, why u dont increase the wattage of the lumanaires to achieve the 500 lux level

    • @catalindesigner
      @catalindesigner Месяц назад

      Thanks for your comment. If you increase the wattage of the luminaire you are reducing the uniformity and you don't want to do that. You need to find the proper balance between lumen output, distribution curve of the luminaire, number of luminaries for that space and achieve a uniformity as high as possible.

  • @MohammadAhmad-lc5xf
    @MohammadAhmad-lc5xf 2 месяца назад

    thank you 🌹

  • @ayaribrahim4914
    @ayaribrahim4914 2 месяца назад

    Nice

  • @hileltiaiba7036
    @hileltiaiba7036 2 месяца назад

    Very Nice thanks

  • @peturkrustev3845
    @peturkrustev3845 2 месяца назад

    how is it that the uniformity is less than 0.40 and the result is positive?

    • @catalindesigner
      @catalindesigner 2 месяца назад

      Hi @peturkristev3845, you are right the results should be negative, due to lower uniformity. I believe that it a software error. Thanks for your comment.

    • @Nopublicname
      @Nopublicname Месяц назад

      @@catalindesigner Hi Catalin, at least you can rewrite it to 0 and then the result is positive. But its not legal.

    • @catalindesigner
      @catalindesigner Месяц назад

      @@Nopublicname thanks for your comment, but to rewrite to 0 is not the right solution

  • @pabloescobar5448
    @pabloescobar5448 3 месяца назад

    Hello please can I get the soft copy of your work🙏. I urgently need it. Thanks a lot

    • @catalindesigner
      @catalindesigner 3 месяца назад

      Hi, yeah sure I can send you the outcome of this project, just send me your mail address.

  • @goku-dd7vf
    @goku-dd7vf 3 месяца назад

    Is dialux still being used for lighting design, or are there any other advanced softwares

    • @catalindesigner
      @catalindesigner 3 месяца назад

      Yes, Dialux is still used as a software for lighting design. Of course in the market are existing other softwares as AGI32 or Redux which can be used for lighting design.

    • @goku-dd7vf
      @goku-dd7vf 3 месяца назад

      @@catalindesigner Thank you

    • @catalindesigner
      @catalindesigner 3 месяца назад

      @@goku-dd7vf You are welcome!

  • @satyajay8276
    @satyajay8276 3 месяца назад

    Can you lease check the sound. Not Audible.

    • @catalindesigner
      @catalindesigner 3 месяца назад

      thanks for your comment. I checked the sound and everything look OK on my side. Did you tried to increase the volume?

  • @titli1018
    @titli1018 4 месяца назад

    Sir, very helpful video. Thankyou

    • @catalindesigner
      @catalindesigner 4 месяца назад

      Thanks for your comment! If you need more help you can subscribe to my channel and check the other videos as well!

  • @InnovationEngg
    @InnovationEngg 5 месяцев назад

    Great 🎉🎉🎉

  • @InnovationEngg
    @InnovationEngg 5 месяцев назад

    Great 🎉🎉🎉

  • @Fuckmahidol
    @Fuckmahidol 5 месяцев назад

    Good luck keep going bro

  • @mohibullah9172
    @mohibullah9172 6 месяцев назад

    Hello Respected Sir, I am working on a project at our hospital which includes shifting of pole solar lights to pole flood lights because of poor lighting and performance of these solar ligths. Sir, we have the boundary wall around the hospital buildings which lengths 531meter south wall, 440meter northside boudary wall and approximately 220 meter each each and west boudary walls. We have 62 poles already installed for solar lights what i am going to do is to replace solar lights with phillips 100w flood lights to improve serveillance and security of the hospital boundary wall and i do not have any site plans to import into dialux evo 12.1. Please suggest me for having proper working on this project at dialux. Bundle of thanks

    • @catalindesigner
      @catalindesigner 6 месяцев назад

      Hi, as mentioned in my previous comment. You can adjust the lumen output of the old luminaire with the new value of the new lamp to you are planning to use. In this way you are able to get a correct light simulation. I will try to make a video to show how you can do that. Kind regards, Catalin

    • @catalindesigner
      @catalindesigner 6 месяцев назад

      Hi, you have to measure the distance between two poles and the total area that you have to make the lighting calculation. it will be easier ion you can add this measurements in auto cad and then generate a dwg file which you could import into Dialux

  • @mohibullah9172
    @mohibullah9172 6 месяцев назад

    Hello Respected Sir, I am working on a project at our hospital which includes shifting of pole solar lights to pole flood lights because of poor lighting and performance of these solar ligths. Sir, we have the boundary wall around the hospital buildings which lengths 531meter south wall, 440meter northside boudary wall and approximately 220 meter each each and west boudary walls. We have 62 poles already installed for solar lights what i am going to do is to replace solar lights with phillips 100w flood lights to improve serveillance and security of the hospital boundary wall and i do not have any site plans to import into dialux evo 12.1. Please suggest me for having proper working on this project at dialux. Bundle of thanks

    • @catalindesigner
      @catalindesigner 6 месяцев назад

      Thanks for your message. It should be possible to change the power output from the old luminaire to the new one. However to have a proper lighting calculation in Dialux, you need to use the IES or LDT file of the old luminaire and just change the power or lumen output to the new lamp. In this case 100 W Philips lamp. Hope that this information will help you.

  • @ahmedabduraheimmoalim344
    @ahmedabduraheimmoalim344 6 месяцев назад

    Thanks sir

    • @catalindesigner
      @catalindesigner 6 месяцев назад

      Thanks for your message! Hope the other videos will help you as well!

  • @a-zmallu6117
    @a-zmallu6117 6 месяцев назад

    Is there any method to add non member ies files without paying subscription

    • @catalindesigner
      @catalindesigner 6 месяцев назад

      Hi, unfortunately I can not provide you an answer. The best way is to address this question directly to Dialux support.

  • @BjornFarber
    @BjornFarber 7 месяцев назад

    use the "calculate without furniture" button for hidden surfaces. It is to the left of the emergency groups

  • @eliasidbarria10
    @eliasidbarria10 7 месяцев назад

    Why target not appear in the results for calculation surface?

    • @catalindesigner
      @catalindesigner 7 месяцев назад

      Thanks for the question. Usually you setup the target of lux level based on the application|space that is defined in standards and as well in Dialux. The surface calculation is giving you an exact value for a specific area defined by you, compared with the overall lux level as you can see in this video from minute 15"52. Hope that everything is clear now.

  • @HamdaAlmarzooqi-hl9ir
    @HamdaAlmarzooqi-hl9ir 8 месяцев назад

    Good Day, the Create Template feature is not available in dialux evo 12.1 or 12. Do you have an idea how to find it ?

    • @catalindesigner
      @catalindesigner 8 месяцев назад

      Thanks for your message. I have to install the Dialux evo 12 or 12.1 and check this feature. Next week I will let you know.

  • @catalindesigner
    @catalindesigner 8 месяцев назад

    Check the lighting design for indoor parking part I and part II as well

  • @princyrijesh7720
    @princyrijesh7720 8 месяцев назад

    From where we can find gym thread mill and other gym 3d models??

    • @catalindesigner
      @catalindesigner 8 месяцев назад

      Thanks for your question. I made a video to show from where you can download the 3d furniture and how to uploaded to Dialux. Hope that this informations helps you. Let me know if you could do it.

  • @adicrisan5094
    @adicrisan5094 9 месяцев назад

    Salut Cătălin, lucrez pentru o companie din NYC care face design and build, lighting, retrofit LED in școli, universități, spitale etc. Imi poți lăsa un număr de telefon pentru o oportunitate de lucru? Mulțumesc.

    • @catalindesigner
      @catalindesigner 9 месяцев назад

      Salut Adi. Te rog sa mi trimiti un mesaj la adresa mea de mail Catalin.prahase@gmail.com. Nu as vrea sa fac public numărul meu de telefon aici. Mersi de mesaj.

  • @zaze4824
    @zaze4824 9 месяцев назад

    How do you turn the lights on? In my case I can't do it.. I mean I can do the calculations but the lights are off and I don't know why, thanks in advance

    • @catalindesigner
      @catalindesigner 9 месяцев назад

      Thanks for your comment. Did you add a calculation surface for outdoor lighting? before running the calculation or adding the luminaire.. let me know

    • @zaze4824
      @zaze4824 9 месяцев назад

      @@catalindesigner aaah the calculation surface for outdoor is different to the indoor? I think I didn't have that in count

    • @catalindesigner
      @catalindesigner 9 месяцев назад

      @@zaze4824 I made a video related to this theme / How to turn ON outdoor lighting ruclips.net/video/Tf_5hIbRIUs/видео.html

    • @zaze4824
      @zaze4824 9 месяцев назад

      @@catalindesigner thank you so much I'll check it

    • @catalindesigner
      @catalindesigner 9 месяцев назад

      @@zaze4824 you are welcome!

  • @sharvinmurugan9243
    @sharvinmurugan9243 10 месяцев назад

    Can i get the evo file of this corridor for some training?

    • @catalindesigner
      @catalindesigner 9 месяцев назад

      Thanks for your comment. Unfortunately, I created the corridor space, therefore is no dwg file available which I can share with you. However next weekend I will do a video to show how you can create your own space based on your dimensions. BR, Catalin

    • @catalindesigner
      @catalindesigner 9 месяцев назад

      Hi, I made the following video, where you can see how to create your own space in Dialux evo. Hope that it is helping u. ruclips.net/video/tL63J8kIKSo/видео.html

  • @fliqur6516
    @fliqur6516 10 месяцев назад

    I have a question : If i have a multi story building, if i want to place downlights/cans on the landing of each half story (if that makes sense). How do i place the luminaire on the story above (due to the story heights) and still have the light output being shown in my calculation results for the floor below? Does that make sense? I hope so 😅😂

    • @catalindesigner
      @catalindesigner 10 месяцев назад

      Hi, thanks for your question. From my point of view you have 2 options how you can deal with this situation. First option is to add calculation surface on each level, and then you can see the value of light output. Second option is to design separately the staircase for the entire building and find out the light output. Hope that this information will help you. Kind regards, Catalin

  • @simisvas
    @simisvas 11 месяцев назад

    It’s incorrect calculation, becouse lumen outup on emergency mode will not be 100% of regular mode . Thanks

    • @catalindesigner
      @catalindesigner 11 месяцев назад

      thanks for your comment. Please check the emergency luminaire properties at the minut 1:02 of the video to see the light output. with the LED technology things got better.

  • @devipde
    @devipde 11 месяцев назад

    share cad drawing for practice

    • @catalindesigner
      @catalindesigner 11 месяцев назад

      Unfortunately, I can not share the CAD file.

  • @er.tariqalamfarooqi4771
    @er.tariqalamfarooqi4771 Год назад

    Sir, is it possible to get work from Home in dialux evo??

    • @catalindesigner
      @catalindesigner Год назад

      Hi, I am doing just examples of lighting projects in Dialux

  • @abdullahrajab3830
    @abdullahrajab3830 Год назад

    thank you sir

  • @zoltanvarga3583
    @zoltanvarga3583 Год назад

    Maan, dont feel that I hating you, really not in bad , just simple my good advice - this emergency lighting simulation is wrong as it is possible - the escape route (the side corridor/stairs are part of the escape route too, minimum on the left side because of the upper door opening and the antipanic area where the seats are, where is?- I know that the simulation will without the seats, just the whole area, but it shall be approved too)...I really hope that this is not final version (measurement area/route placement) of the simulation - and really not in bad, peace

    • @catalindesigner
      @catalindesigner Год назад

      thanks Man for your comment. I apreciate you time in checking the video. As you can see in the video I took the antipanic, a flat area as an example how you can define it and not for implementation. If this project had to be implemented then you need to do the correct setup of height for each row of sets. In the case of escape routes, you just need to add the escape signs above the two doors, knowing that the antipanic lighting system will provide a higher light level than the one requested for escape routes.

  • @zoltanvarga3583
    @zoltanvarga3583 Год назад

    Can you explain me what´s the reason of dual emergencey route next to each other? (I think its so wrong) - and real measurement for emergency lighting will not start directly from the wall ...

    • @catalindesigner
      @catalindesigner Год назад

      thanks for you comment. As you said already mentioned is not point of having for one room dual emergency-at least for a small office space, for a big open office the situation can be different. This video is about how you can define the emergency lighting. Also the general lighting will not start directly from the wall, only if you edit manually the distance. Hope that now everything is clear.

  • @benhammadiafaf5538
    @benhammadiafaf5538 Год назад

    Hi catalin, thank you so much !

  • @Sasha-rr3yr
    @Sasha-rr3yr Год назад

    Hi, you have used 60x60 panel lights- I haven't noticed if you have placed false ceiling? You have to have false ceiling when you are using 60x60 panel, am I wright?

    • @catalindesigner
      @catalindesigner Год назад

      Thanks for your comment. Most of lighting manufacturers are providing different installation options for 60x60 lighting fixture. Even the 60x60 is common recessed used in a false ceiling, you can install the same luminare surface or suspend mounted.

    • @Sasha-rr3yr
      @Sasha-rr3yr Год назад

      Thank you

  • @ivanprado6504
    @ivanprado6504 Год назад

    Thats a conventional design, you waste more energy. The best solution its a qualitative design especially in oppen plan offices. You just focus the light where you reaaly need it eg the table en meeting room in the video and verify if you get 500 lx there not in the hole room

    • @catalinemilprahase7527
      @catalinemilprahase7527 Год назад

      Thanks for your comment. Appreciate your feedback. Related to your lighting it’s an Yes and No in the same time :). For new offices you can proposal free standing luminaries, but still you need additional luminaries for the background and surrounding areas. With a local lighting you will not be able to cover all the need for a modern office. My second point related to conventional lighting design. You need to consider that many office building have been equipped with 6x6 and 3x12 luminaries with fluorescent lamps. In these office buildings few investors will go with a total new layout of the ceiling. So the easy and fast way also from electrical circuits its a one to one replacement. From old to new LED luminaries.

    • @catalindesigner
      @catalindesigner Год назад

      Please find my comment below.

  • @toinetteborchelt1807
    @toinetteborchelt1807 Год назад

    'Promo sm'

  • @muhammadalvan8426
    @muhammadalvan8426 Год назад

    hello do you make tutorial how to make this project? i need to make something like this

    • @catalindesigner
      @catalindesigner Год назад

      In the following video you can find more information about this project. Hope that this video will help! ruclips.net/video/TDuBU8n_qIc/видео.html

  • @Cambo-SR
    @Cambo-SR Год назад

    thank you

  • @Cambo-SR
    @Cambo-SR Год назад

    thank you 👁‍🗨👁‍🗨❤❤❤❤bedroom lux specific ?

    • @catalindesigner
      @catalindesigner Год назад

      Have a look on the following video, where I am talking about lighting concept for your house.

  • @alriashi7
    @alriashi7 Год назад

    that was sooo beneficial for me ..thanks..

  • @arishsiddiqui3292
    @arishsiddiqui3292 Год назад

    Hello Sir. Great video! I had one question though, why did you not consider the furniture and also ignore the first reflection. Aren't both of these necessary for accurate results?

    • @catalindesigner
      @catalindesigner Год назад

      Hello, I did not mentioned about the furniture and refection because the main target was the lux level for emergency lighting to be achieved. However once you place the furniture into one space when you run the lighting calculation, the software takes into account the furniture placed in that space. I would do a video where I can explain and show the difference of illuminance with furniture and without furniture. Hope that I answer to your question. Thanks for your comment. BR, Catalin

    • @arishsiddiqui3292
      @arishsiddiqui3292 Год назад

      @@catalindesigner Still a bit confused, Shouldn't we have the option "calculate without furniture" off when calculating emergency lighting levels of a space with furniture in it in order to get the accurate lux level results? Appreciate your time and response.

    • @catalindesigner
      @catalindesigner Год назад

      @@arishsiddiqui3292 It will be great to have this feature in this software, let say as default: excluding or including the furniture for lighting calculation. Unfortunately for time being this option doesn't exist in the software. My opinion is that this option docent exist as usually all the rooms are being equipped with furniture, therefore the lighting calculation is done based on a realistic scenario.

    • @arishsiddiqui3292
      @arishsiddiqui3292 Год назад

      @@catalindesigner Thanks Catalin, appreciate your reply.

    • @catalindesigner
      @catalindesigner Год назад

      You are welcome!@@arishsiddiqui3292

  • @NelcaRoco
    @NelcaRoco Год назад

    I think you did it wrong. 😢

    • @catalindesigner
      @catalindesigner Год назад

      No problem, everything can be done better. Here is the video with the changed surface. ruclips.net/video/9Go4bYE1Z7o/видео.html

  • @manjudileep5477
    @manjudileep5477 Год назад

    Hi Catalin, thanks for the video!Can we change the target lux levels on the emergency / escape route calculation

    • @catalindesigner
      @catalindesigner Год назад

      Hi @manjudileep5477. First of all thanks for your question, to answer to your question I made the following video ruclips.net/video/dHY4tiIh74Q/видео.html. Please let me know if everything is clear now? Thanks :)

  • @josepreza8175
    @josepreza8175 Год назад

    ¿Las brp101 son de la fábrica PHILIPS Brazil? Saludos

    • @catalindesigner
      @catalindesigner Год назад

      Hi, unfortunately I don't know where these products have been manufacture

  • @er.tariqalamfarooqi4771
    @er.tariqalamfarooqi4771 Год назад

    sir how to glow the lights?

    • @catalindesigner
      @catalindesigner Год назад

      Hi, have a look on the following video ruclips.net/video/hOdE0Y0Arwg/видео.html. Usually after you run the lighting calculation you are able to see the luminaires turned ON.

  • @shaylaruhoff1905
    @shaylaruhoff1905 Год назад

    'promosm' 😂