Ardent Scientific
Ardent Scientific
  • Видео 123
  • Просмотров 1 319 760

Видео

HPLC Tips and Troubleshooting 21 - Extra Column Volume Effects
Просмотров 7 тыс.6 лет назад
This video describes the effect of extra column volume in the system.
HPLC Tips and Troubleshooting 20 - Broad Unusual Peaks
Просмотров 8 тыс.7 лет назад
This video shows one of the main reasons why a peak appears unusually broad compared to other peaks in the chromatogram.
HPLC Tips and Troubleshooting 19 - The Guard Column
Просмотров 7 тыс.7 лет назад
This video describes the benefits of using a guard column installed before your analytical column.
HPLC Tips and Troubleshooting 18 - Endcapped Columns
Просмотров 11 тыс.7 лет назад
This video describes the process of HPLC column endcapping and explains why it is used.
HPLC Tips and Troubleshooting 17 - Poor Peak Shape
Просмотров 8 тыс.7 лет назад
This video explains some of the causes behind poor peak shape in HPLC.
HPLC Tips and Troubleshooting 16 - Column Voiding
Просмотров 6 тыс.7 лет назад
This video describes column voiding and how it affects peak shape and how to avoid it.
HPLC Tips and Troubleshooting 15 - Monitoring Column Performance
Просмотров 7 тыс.7 лет назад
This video describes the parameters you should keep an eye on for HPLC column performance monitoring.
HPLC Tips and Troubleshooting 14 - Injection Solvent
Просмотров 3,6 тыс.8 лет назад
This video describes the importance of the injection solvent in achieving good resolution
HPLC Tips and Troubleshooting 13 - Rotor Seal Maintenance
Просмотров 5 тыс.8 лет назад
This video outlines the reasons for HPLC autosampler rotor seal maintenance.
HPLC Tips and Troubleshooting 12 - Pressure Testing the Autosampler
Просмотров 6 тыс.8 лет назад
This video describes the pressure testing of the HPLC autosampler valve.
HPLC Tips and Troubleshooting 11 - Peak Area Reproducibility
Просмотров 6 тыс.8 лет назад
This video shows how the HPLC autosampler is most likely to affect peak area reproducibility.
HPLC Tips and Troubleshooting 10 - Pump Pressure Test
Просмотров 9 тыс.8 лет назад
This video shows an animation of a pump pressure test which is common on many HPLC systems.
HPLC Tips and Troubleshooting 9 - The Check Valve
Просмотров 6 тыс.8 лет назад
This video shows the maintenance of a HPLC check valve.
HPLC Tips and Troubleshooting 8 - Solvent Mixing and Retention Factor Tip
Просмотров 6 тыс.8 лет назад
This video describes how an understanding of solvent proportioning in relation to the retention factor can help diagnose instrument issues.
HPLC Tips and Troubleshooting 7 - Pump Flow and the Retention Factor
Просмотров 6 тыс.8 лет назад
HPLC Tips and Troubleshooting 7 - Pump Flow and the Retention Factor
HPLC Tips and Troubleshooting 6 - Solvent Leakage from Pump Seal Wear
Просмотров 8 тыс.8 лет назад
HPLC Tips and Troubleshooting 6 - Solvent Leakage from Pump Seal Wear
HPLC Tips and Troubleshooting 5 - Pump Seal Wear and Tear
Просмотров 7 тыс.8 лет назад
HPLC Tips and Troubleshooting 5 - Pump Seal Wear and Tear
HPLC Tips and Troubleshooting 4 - The Piston Pump Seal
Просмотров 9 тыс.8 лет назад
HPLC Tips and Troubleshooting 4 - The Piston Pump Seal
HPLC Tips and Troubleshooting 3 - Priming the Pump
Просмотров 18 тыс.8 лет назад
HPLC Tips and Troubleshooting 3 - Priming the Pump
HPLC Tips and Troubleshooting 2 - Degasser Tip
Просмотров 10 тыс.8 лет назад
HPLC Tips and Troubleshooting 2 - Degasser Tip
HPLC Tips and Troubleshooting 1 - Filtering and Degassing the Mobile Phase
Просмотров 18 тыс.8 лет назад
HPLC Tips and Troubleshooting 1 - Filtering and Degassing the Mobile Phase
HPLC Instrumentation 27 - Quantitation
Просмотров 11 тыс.8 лет назад
HPLC Instrumentation 27 - Quantitation
HPLC Instrumentation 26 - Diode Array Detector
Просмотров 50 тыс.8 лет назад
HPLC Instrumentation 26 - Diode Array Detector
HPLC Instrumentation 25 - Detector Flow Cell
Просмотров 17 тыс.8 лет назад
HPLC Instrumentation 25 - Detector Flow Cell
HPLC Instrumentation 24 - Sample Separation and Detection
Просмотров 10 тыс.8 лет назад
HPLC Instrumentation 24 - Sample Separation and Detection
HPLC Instrumentation 23 - Variable UV Detector
Просмотров 18 тыс.8 лет назад
HPLC Instrumentation 23 - Variable UV Detector
HPLC Instrumentation 22 - Detector Overview
Просмотров 10 тыс.8 лет назад
HPLC Instrumentation 22 - Detector Overview
HPLC Instrumentation 21 - The Rotor Seal
Просмотров 12 тыс.8 лет назад
HPLC Instrumentation 21 - The Rotor Seal
HPLC Instrumentation 20 - How a HPLC Autosampler Works
Просмотров 33 тыс.8 лет назад
HPLC Instrumentation 20 - How a HPLC Autosampler Works

Комментарии

  • @guava1748
    @guava1748 4 месяца назад

    Keep going 🎉❤❤❤

  • @guava1748
    @guava1748 4 месяца назад

    Good job 🎉❤

  • @guava1748
    @guava1748 4 месяца назад

    ❤❤❤

  • @guava1748
    @guava1748 4 месяца назад

    ❤❤❤❤

  • @guava1748
    @guava1748 4 месяца назад

    V.good ❤

  • @guava1748
    @guava1748 4 месяца назад

    Omg ❤❤❤🎉

  • @guava1748
    @guava1748 4 месяца назад

    🫡🫡🫡🫡❤

  • @guava1748
    @guava1748 4 месяца назад

    ❤❤❤❤❤❤❤❤

  • @guava1748
    @guava1748 4 месяца назад

    ❤❤❤❤

  • @guava1748
    @guava1748 4 месяца назад

    Your explanation is very nice and concise 🤍

  • @mabel222nunez
    @mabel222nunez 4 месяца назад

    these videos are helping me comprehend everything for my exam!!! thank you so much, they are all incredibly well made, hard work of yours!!

  • @rodness_
    @rodness_ 6 месяцев назад

    Excellent!!

  • @mabel222nunez
    @mabel222nunez 7 месяцев назад

    super useful, thank you

  • @joepalmer5251
    @joepalmer5251 10 месяцев назад

    I like tacos

  • @usmanmajeed6336
    @usmanmajeed6336 11 месяцев назад

    that's good

  • @thebluebeyond2329
    @thebluebeyond2329 Год назад

    How do l find the unretained time?

  • @furgasagb7899
    @furgasagb7899 Год назад

    good work keep it up!!!

  • @owaisd6360
    @owaisd6360 Год назад

    You compared HPLC with liquor and airports?

  • @barbaraaghimien1786
    @barbaraaghimien1786 Год назад

    very helpful video thanks !!

  • @sergirodilperalta4287
    @sergirodilperalta4287 Год назад

    Nice explained! Keep uploading videos

  • @Bati_Games
    @Bati_Games Год назад

    what is meant if retention factor is greater than 1, or less than 1?

  • @TheJoshtheboss
    @TheJoshtheboss Год назад

    Hello, where can I use your interactive website.

  • @あいしてる-s6z
    @あいしてる-s6z 2 года назад

    used on science class well done

  • @baltgames1
    @baltgames1 2 года назад

    Why is important to know retention factor?

    • @ardentscientific7080
      @ardentscientific7080 2 года назад

      Because the retention factor shows the true retention of a compound i.e. the degree of interaction with the stationary phase. The retention time is only an indication.For example, if you connect a large length of tubing between the column and the detector, the retention time increases but the actual retention has not changed. Also the retention factor is useful for problem solving because it is a ratio of the time the component interacts with stationary phase over the time the component spends in the mobile phase. If the flow changes, the retention time will change but the retention factor will remain the same. If selectivity changes (for example the temperature or mobile phase composition or the column), the retention factor will change.

  • @jorgecastilloramirez3108
    @jorgecastilloramirez3108 2 года назад

    This video is no working, I used last month was OK. Other videos in series are working

    • @ardentscientific7080
      @ardentscientific7080 2 года назад

      Suggest you use another browser if possible. I have also had issues recently in Safari but MS Edge is fine.

    • @jklavz
      @jklavz Год назад

      Works at 360p only for me.

  • @seyedmohammadseyedkhademi2454
    @seyedmohammadseyedkhademi2454 2 года назад

    With respect Very helpful videos. Bit how can I found all of Video and your animation about HPLC? In you tube I could only few of them. Could you please guide me?

    • @ardentscientific7080
      @ardentscientific7080 2 года назад

      Hi, yes just look at the Ardent Scientific RUclips channel - they are all there!

  • @daqinnlokoctober3884
    @daqinnlokoctober3884 2 года назад

    The more percentage of the organic modifier is in the mobile phase (more hydrophobic), the less chance the components interact with the stationary phase (hydrophobic).

  • @anitaaranyos9112
    @anitaaranyos9112 2 года назад

    Remarkable video! Thanks for visualizing these factors, greatly support the true understanding of the process.

  • @ArisaRowen
    @ArisaRowen 2 года назад

    Hi. Thank you for such an amazing explanation. I had a question though. Is there a name assigned to this auto-sampler.

  • @pharmasolutionpakistan7668
    @pharmasolutionpakistan7668 3 года назад

    ruclips.net/channel/UCclJKlJplPCcFNKd-HzSwgA

  • @pharmasolutionpakistan7668
    @pharmasolutionpakistan7668 3 года назад

    Good

  • @nitishmishra3043
    @nitishmishra3043 3 года назад

    Good explanation

  • @pharmasolutionpakistan7668
    @pharmasolutionpakistan7668 3 года назад

    good

  • @michelleanne6500
    @michelleanne6500 3 года назад

    Nice explanation. The animation really clarifies the concepts. Thank you

  • @pharmasolutionpakistan7668
    @pharmasolutionpakistan7668 3 года назад

    ruclips.net/channel/UCclJKlJplPCcFNKd-HzSwgA

  • @pharmasolutionpakistan7668
    @pharmasolutionpakistan7668 3 года назад

    Good job

  • @marziyehshahrami5522
    @marziyehshahrami5522 3 года назад

    Great explanation 👌🏻

  • @marziyehshahrami5522
    @marziyehshahrami5522 3 года назад

    Great explanation 👌🏻

  • @peaceevbuomwan7815
    @peaceevbuomwan7815 3 года назад

    Very clear information, thanks so much for this!

  • @arslanafzal6813
    @arslanafzal6813 3 года назад

    Why tungsten lamp used.

  • @arslanafzal6813
    @arslanafzal6813 3 года назад

    What is the function of tungstun lamp in this process

    • @weictory
      @weictory 3 года назад

      to strengthen the intensity of visible spectrum wavelength

    • @UdayBundeliya
      @UdayBundeliya 11 месяцев назад

      It's basically a source of visible radiation

  • @boontje654
    @boontje654 3 года назад

    kusje op je voorhoofd poes xx

  • @vandanasindhu1582
    @vandanasindhu1582 3 года назад

    Please tell me, if I have a compund X, is this compound X shows the same or different retention time in HPLC and GC

  • @helmuti5149
    @helmuti5149 3 года назад

    Gutes Video, könnte ruhig länger sein :)

  • @dipuswapnu
    @dipuswapnu 3 года назад

    sir exactly what is the no.of theriotical plate either not less than 1500 or either NLT 2500? which is correct.... please tell me🙏

  • @nikolaibasic5395
    @nikolaibasic5395 4 года назад

    amazing!

    • @jacobvandijk6525
      @jacobvandijk6525 Месяц назад

      I find it amazing (and disappointing) that there is no link to a playlist.

  • @hks9899
    @hks9899 4 года назад

    Really thanks sir 🙏

  • @jonnathancar4735
    @jonnathancar4735 4 года назад

    What program do you use to do the HPLC demonstrations?

  • @137bob3d
    @137bob3d 4 года назад

    thanks for making this vid and its bite-size ideas ... helped me understand a little more of C18 silica

  • @sarahrosse2178
    @sarahrosse2178 4 года назад

    Expliquer brièvement pourquoi est-il difficile d'obtenir des temps de rétention (temps au bout duquel un composé est élué de la colonne et détecté) imitables en HPLC de phase normale, sachant que la silice est très hygroscopique