MrRight2006
MrRight2006
  • Видео 1
  • Просмотров 44 389
Cryo TEM sample preparation using Vitrobot
"In science, we believe in sharing."
Sit back and enjoy the show!
If you want to give credit, please give credit to the Cryo EM facility of the National University of Singapore.
Просмотров: 44 397

Видео

Комментарии

  • @MachinedInWood
    @MachinedInWood Месяц назад

    Now I know why it didn’t work for me. I forgot to faster the cooling……

  • @rg-pu9nz
    @rg-pu9nz Год назад

    انا حعمل Un subscribe للقناة عشان جاب التلوث دا .

  • @teleportvalorant7658
    @teleportvalorant7658 2 года назад

    Hi everyone.If you read this message please read the Holy Quran the direct words and the final message from Almighty God.It will guide you to peace truth and happiness in this world and the afterworld with my lovely wishes

  • @borjaabascalimizcoz8248
    @borjaabascalimizcoz8248 3 года назад

    Thanks very much for the video!! Its very helpful!

  • @황혜랑-y1w
    @황혜랑-y1w 4 года назад

    3:28 4:43 6:22 6:32 6:51 7:47

  • @frankthespank
    @frankthespank 5 лет назад

    Will this help me sneak dinosaur embryos out of the park?

  • @solarbuff350
    @solarbuff350 6 лет назад

    Great video. One question: When you take the sample out of ethane and into the liquid nitrogen, can you dip the tweezer in the liquid N2 as well? If you dip the tip of the tweezer too much, there will be bubbling because the upper portion of the tweezer is still at room temperature and I wonder if the ice will be formed on the sample because of this. I cannot see where your liquid nitrogen level is, so cannot be sure what you did at this step. Thanks!

    • @borjaabascalimizcoz8248
      @borjaabascalimizcoz8248 3 года назад

      To avoid that you can dip the tweezer before taking the grid, or at least touch the edge of the metal cylinder. I hope this helps :)

  • @PedroRodriguez-Amor-y-Paz
    @PedroRodriguez-Amor-y-Paz 9 лет назад

    Vitrobot FEI

  • @BhanuMantri
    @BhanuMantri 9 лет назад

    how you can set the lot time and blot force ? what are the parameters we should keep in mind to set these values?

  • @jingchuansun6915
    @jingchuansun6915 10 лет назад

    You didnot put anti-contaminator (a float ring on LN2). Why?

    • @SofyaPolyanskaya1
      @SofyaPolyanskaya1 10 лет назад

      To let people see the details of the process obviously.

  • @MrRight2006
    @MrRight2006 11 лет назад

    Parameters depend on the nature of sample. You need to play with different parameters at first. Try with different blot time at first. Vary between 1 and 10 sec . Then try changing blot force. Sample amount is about 3 to 3.5ul. The trick in the transfer is that you need to have a stable hand during transfer. Rest your palm on the cup, release tweezers and then transfer.

  • @buzy2a
    @buzy2a 11 лет назад

    hi, could you give me the diffrent paramaters you use: Blot time, bolt total, blot force and the quantity of liquid you put on the grid ? And do you use a special trick to transfer the grid from the ethane to LN2 ? Thx a lot

  • @MrRight2006
    @MrRight2006 12 лет назад

    you welcome!

  • @MrRight2006
    @MrRight2006 12 лет назад

    welcome :)

  • @tongsheng00
    @tongsheng00 12 лет назад

    It helps a lot. Thanks.