I am a NJ Master HVACR contractor license holder, home renovator and handyman. I have extensive experience in the HVAC field along with adequate knowledge in plumbing, electrical and carpentry to perform most tasks around a house. Subscribe to my channel for more around the home how to videos and other informative content.
Semi Hermetic Compressor Valve Plates Replacement
Replacing valve plates on a Copeland semi hermetic compressor. Part two of this video coming soon.
Follow me on twitter - _TravisMichael
Hello Everyone,
I am a NJ Master HVACR contractor license holder, home renovator and handyman. I have extensive experience in the HVAC field along with adequate knowledge in plumbing, electrical and carpentry to perform most tasks around a house. Subscribe to my channel for more around the home how to videos and other informative content. This video is not sponsored by any brands, products or companies seen or referred to in the video. Always check for power to verify electrical source has been isolated before working on any HVAC equipment. Alw...
Follow me on twitter - _TravisMichael
Hello Everyone,
I am a NJ Master HVACR contractor license holder, home renovator and handyman. I have extensive experience in the HVAC field along with adequate knowledge in plumbing, electrical and carpentry to perform most tasks around a house. Subscribe to my channel for more around the home how to videos and other informative content. This video is not sponsored by any brands, products or companies seen or referred to in the video. Always check for power to verify electrical source has been isolated before working on any HVAC equipment. Alw...
Просмотров: 7 530
Видео
TRANE No Heat Call, Is It The Hot Surface Igniter, Control Board Or Something Else?
Просмотров 11 тыс.2 года назад
TRANE No Heat Call, we take a look at a Trane roof top unit with no heating operations. I thoroughly check the necessary components to make the correct diagnosis for the reason of the heat failure. Follow me on twitter - _TravisMichael Hello Everyone, I am a NJ Master HVACR contractor license holder, home renovator and handyman. I have extensive experience in the HVAC field along wi...
My Experience With Fieldpiece's Tool Repair Process And A Refrigerant Leak That Wasn't Easy To Find
Просмотров 1,9 тыс.3 года назад
Finally got my Fieldpiece SMAN 460 back from Fieldpiece's repair center. Also, we look at a tiny refrigerant leak that was difficult to locate. Follow me on twitter - _TravisMichael Hello Everyone, In this video I discuss my experience with Fieldpiece tool repair process. I provide information regarding cost of repair and how long the process took. Further more, I also discuss a lea...
Daikin VRV IV - How To Activate Refrigerant Recovery And Evacuation Mode
Просмотров 25 тыс.3 года назад
Quick and straight forward demonstration on how to switch a Daikin VRV IV system into refrigerant recovery and evacuation mode. Follow me on twitter - _TravisMichael Hello Everyone, In this video I demonstrate how to place a Daikin VRV IV system into refrigerant recovery and evacuation mode. I also show how to return the system to normal operating mode. Further more, I explain when ...
50 Ton AAON RTU, Follow Up Repairs, Replacing Defective Contactors And Time Delays.
Просмотров 1,4 тыс.3 года назад
Follow up repairs from a previous service call of no cooling on a 50 ton Aaon roof top unit. 3 of 4 compressor not operating. This is a common problem with these units. I replace all four compressor contactors and 7 time delay relays. Follow me on twitter - _TravisMichael Hello Everyone, In this video I perform follow up repair work from a previous service call which I made a video....
Addison Roof Top Unit, Crankcase Heater Found Arcing And Smoking After Washing Condenser Coils.
Просмотров 3783 года назад
This crankcase heater was failing in front of me. Arcing can be heard and smoke can be seen. Check out the entire video to find out whether I took action on this issue or if I put the HVAC blinders on and let it be a problem for another day. Follow me on twitter - _TravisMichael Hello Everyone, In this video we take a look at a failing crankcase heater on an Addison Dehumidification...
Repairing A Condenser Coil Leak At The Tube Sheet And Locating The Leak With Inficon TEK-Mate
Просмотров 1,8 тыс.3 года назад
Locating and repairing a leak on a York condensing unit at the tube sheet of the condenser coil. Some things to look for to help identify location of the leak and recommendations of what to do when repairing. Follow me on twitter - _TravisMichael Hello Everyone, In this video I locate and repair a leak on a condenser coil of a York split system. I demonstrate how to easily locate a ...
15 Ton York Roof Top Unit, Look For This When Leaking Checking A Refrigeration Circuit.
Просмотров 9983 года назад
Locating a leak on a York roof top unit. Some things to look for to help identify location of the leak and recommendations of what to do when repairing. Follow me on twitter - _TravisMichael Hello Everyone, In this video I am working on a leak check and repair of a roof top package unit. I demonstrate how to easily locate a leak by using nitrogen and identifying visual signs of a le...
How To Diagnose A Defective HVAC Control Board, 3 Things To Check To Easily Troubleshoot
Просмотров 1,2 тыс.3 года назад
How to diagnose a defective HVAC control board of any brand or type. Determine the proper diagnosis by check just these three things. Thermostat Inputs, Safety and control circuit input/output and contactor/replay output. Follow me on twitter - _TravisMichael Hello Everyone, In this video I take a service call of AC system not reaching set point temperature. I demonstrate how to eas...
The Dirtiest Condenser Coil I Have Ever Seen, My Suggestion On How To Prevent This.
Просмотров 1,5 тыс.3 года назад
This has got to be the dirtiest A/C condenser coil I have came across in my career. Appears that maintenance has not been performed on these systems in quite sometime. The coil is completely plugged and the system needs a leak check and repair. Follow me on twitter - _TravisMichael Hello Everyone, In this video I take you on to a job site that has a few condensing unit which I was i...
Stop Work Order And How We Handled It, My Recommendations On What To Do When This Happens
Просмотров 1,4 тыс.3 года назад
Working on a job site replacing and repairing numerous unit heaters. The state showed up and told us to stop work because they had no record of permits being pulled. The following day the town popped in and told us the same thing. Follow me on twitter - _TravisMichael Hello Everyone, In this video I take you on to a job site where we ran into some issues with the state and local ins...
Fieldpiece SMAN460 Manifold Finally Broke, My Experience And Thoughts On Them.
Просмотров 3,6 тыс.3 года назад
My Fieldpiece SMAN 460 manifold gauges broke they other day on the Job. Should I replace them or go with another brand? Follow me on twitter - _TravisMichael Hello Everyone, In this video I talk about my experience and thoughts on the Fieldpiece digital manifold gauges that I have been working with. I share my experience with using these gauges and discuss whether I will replace the...
Why Condensing Units Should Not Be Installed Inside A Warehouse
Просмотров 1,5 тыс.3 года назад
I see it time and time again, condensing units and outdoor heat pump unit belong outside. The interior of a warehouse in many application is not a conducive environment to the performance and longevity of an air conditioning or heat pump system. Follow me on twitter - _TravisMichael Hello Everyone, In this video I take a look at a job site where there are 3 outdoor heat pump units i...
No Cooling Service Call And Repair 50 Ton Trane Roof Top Unit
Просмотров 2,3 тыс.3 года назад
No Cooling Service Call And Repair 50 Ton Trane Roof Top Unit
25 Ton AAON Roof Top Unit, Both Condenser Coils Leaking And What Caused The Leaks
Просмотров 6 тыс.3 года назад
25 Ton AAON Roof Top Unit, Both Condenser Coils Leaking And What Caused The Leaks
Less Then 24 Hours Left To Pre Register, Don’t Miss Out On Your Grant Of Up To $20,000 In NJ
Просмотров 273 года назад
Less Then 24 Hours Left To Pre Register, Don’t Miss Out On Your Grant Of Up To $20,000 In NJ
Need Your EIDL Advance Grant Now? This NJ Grant Program Can Pay You More Money And Faster!
Просмотров 643 года назад
Need Your EIDL Advance Grant Now? This NJ Grant Program Can Pay You More Money And Faster!
$30 Million Of Grant Funds Dedicated To Bars, Restaurants And Child Care Providers, Must Act By 6/30
Просмотров 143 года назад
$30 Million Of Grant Funds Dedicated To Bars, Restaurants And Child Care Providers, Must Act By 6/30
$10,000 Grants For Sole Props, Side Hustles, LLCs Without Employees, Etc Still Available! How To Get
Просмотров 763 года назад
$10,000 Grants For Sole Props, Side Hustles, LLCs Without Employees, Etc Still Available! How To Get
$20,000 Small Business Grant Is Still Available In NJ, But You Need To Act Fast! How To Apply.
Просмотров 1963 года назад
$20,000 Small Business Grant Is Still Available In NJ, But You Need To Act Fast! How To Apply.
The Worst Mini Split Install I Have Ever Seen - Hack Job
Просмотров 1,9 тыс.3 года назад
The Worst Mini Split Install I Have Ever Seen - Hack Job
Just Because It Looks Good Doesn’t Mean It Is Good - HVAC Install
Просмотров 483 года назад
Just Because It Looks Good Doesn’t Mean It Is Good - HVAC Install
So What Is This Channel About? Travis Michael Channel Trailer
Просмотров 2483 года назад
So What Is This Channel About? Travis Michael Channel Trailer
50 Ton AAON Roof top HVAC Unit, No Cooling Service Call
Просмотров 12 тыс.3 года назад
50 Ton AAON Roof top HVAC Unit, No Cooling Service Call
How To Minimize Refrigerant Loss When Disconnecting Service Hoses
Просмотров 6 тыс.3 года назад
How To Minimize Refrigerant Loss When Disconnecting Service Hoses
How To Diagnose A Faulty Thermostatic Expansion Valve
Просмотров 1,2 тыс.3 года назад
How To Diagnose A Faulty Thermostatic Expansion Valve
Hack Electricians Ruined This Air Conditioning Installation!
Просмотров 1,8 тыс.3 года назад
Hack Electricians Ruined This Air Conditioning Installation!
Review of 2020 Troy-Bilt Storm Tracker 2690 XP Snow Blower.
Просмотров 7 тыс.3 года назад
Review of 2020 Troy-Bilt Storm Tracker 2690 XP Snow Blower.
Snow blowing 28 plus inches of snow - North Western, NJ
Просмотров 62 тыс.3 года назад
Snow blowing 28 plus inches of snow - North Western, NJ
Good job sir thanks for sharing
30 lbs of R-22 Ouch!
I have a bunch of McQuay's . One 90 ton with 6d semi hermertic compressors. I just did this a year ago on my 90 ton RTU. I change oil on compressor, filter driers when doing so.
I have had a few issues also on AAON's. It's like any commercial RTU, they all have problems. Daikin's have had nothing but problems and they don't stand behind their products. Be glad you don't work on Daikin's
It's a matter of ease of finding versus space. Do you lose a considerable amount of space when you have to build out the wal in order to put the sliders on
Nice work.
I like your shirt supporting local food banks. And, it is a very informative demonstration.
-In this mode, do all the solenoid valves open, or does the compressor recover all the gas, including from the piping and indoor units?
Where did u purchase those hinges from. May I ask
simple. thank you for making it easier to understand!
6 years or 5 is not time for $ 500. Not good
Good video man
How do you check the transducers?
More videos on vrv settings 🎉
That's great if you have a Hole there what if there is no hole in the cabinet...
😂 heatwave at 98. That’s chilling temps
This is very good you replacment every part not working.
God damn that 50-ton gives me a hard on
4 x 12.5 ton compressors
Great video, i can now install my own, thank u!
Over controlled units
❤
Life saver
How do you purge the manifold body itself, not just the hoses?
AAONS are the biggest POS out there. Well, one of them. 37 years doing HVAC service and all of the manufactures forgot the KISS principal.
I’m going to call you sometime this week hope all is well Tom Mccann
Doing well, hope the same for you. Talk to you soon Tom
How to replace compressor without remove gas
You can close the isolation valves and remove just the refrigerant that’s in the outdoor unit, you cannot replace the compressor with refrigerant still on the lines.
Oddly enough, my house came with a double door deep pantry and adjustable sliding shelves on the side of my refrigerator like you show. I don't like them... too many steps to get at anything they contain and things are hard to get at in the back of the shelves (even with the pull-out feature, as the cabinet is 24" deep). Two hands are required to open both doors and pull out one or more shelves, each and every time I need access and its too easy to bang the shelves against the door(s) if they are not closed fully. I'm converting both cabinets, upper and lower, to full pull-out pantry units where the door is integrated with the shelf carcass and it then has internal adjustable shelves, using extra heavy duty soft-close drawer slides (275 lbs.). Two slides at the bottom and one at the top to keep it from racking. One action required to open the whole thing and you have access to all contents from the sides, which is way more convenient... especially when unloading groceries.
Sounds like your plan would be a huge improvement to your current cabinets with the double doors. Anything that requires 2 handed operation is far less efficient.
What exactly is the problem with semi-hermatic compressor and you replace all pressure valves etc... ? Appreciate your response as I am a new HVAC Technician learning. Thanks
This system utilizes a pump down cycle to shut the compressor down. Basically a liquid line solenoid valve closes when there is no longer a call mechanical cooling. The compressor is deenergized when the low pressure switch on the suction opens. One or more of the valves were leaking refrigerant back into the suction raising the pressure and causing the compressor to energize. The compressor would repeat the pump down cycle running until the low pressure switch opened again. The compressor was short cycling and running every few minutes for a short period of time.
BUEN TRABAJO FELICIDADES
Thank you
Hey i have a 10 ton unit and i bought hvac gut he couldnt locate the leak.is there any solution in finding the leak.keep on putting freon and keeps dying out because of the leak.
Did the hvac guy pressurize the system with nitrogen and perform a leak search? If not what method of locating the leak was used?
im a building engineer and today I came on roof because tech was doing repairs and I noticed the technician brazed an access port on the unit he was recovering and he also installed a bullet piercing valve and was recovering from both the brazed port and the BPV im like wtf is this shit ... cant be right?? he stated there was no port to recover from but I clearly saw suction line and 2 other original access ports from the daiken RTU ??
im going to look up the manual for that unit and see what those acces ports are because it looked like he only had 1 5/16 to 1/4 hose adapter so he just brazed in a port...
Was this a daikin vrv system? The only thing I can think is that the two factory access ports on the vrv unit are 5/16” and require an adapter to use with standard 1/4” charging hoses. Maybe he didn’t have the adapters? In my opinion the piercing valves are junk and should be removed after use. The other brazed port they were using, did they add that? Not sure how they would have brazed that if they could not recover the system prior to adding it.
Those look very similar in layout to the C box lennox units (15+ ton units) LGC/LGA/LGH type models.
Thank you for sharing. I have a 60 ton that shut down about 30min. And restart when there is 73 + oat and the third compressor kicks in. I never see the 4th run at anytime. I replaced the 4th comp. contactor and it run good for 5 days and start shutting down. advice.
Core depressors with field piece probes are the best way to never ever get burned while barley taking any refrigerant out of system. Hoses trap refrigerant probes don’t. Core depressors guarantee no burns and u control when schrader pin is actually pushed in. Every tech should know this because it changed the way I feel about hooking up. 1/4 inch core depressors are on Amazon for 18$ a pop and field piece probes and clamps ran me about 400$ from a supply house but u can probably find it cheaper. I hope this helps you as much as it helped me.
Thank you sir
I used this today thanks
Just a FYI I bought the same manifold bought a pelican case and came with foam inside to custom fit all my fieldpiece equipment in one sweet hard case
Great video mate
I have an SMAN4 that has a single wire detached from the circuit board. Is there any way you could send me a photo of the circuit board from your gauge set so I could see where the wire goes? Please and thank you!
Does this do both Master and slave
When you have twins unit do I need to set then both or just the master unit
Thank you for taking time and creating this video.
The gloves he’s wearing is the trick. Ball valve and low loss are great but one bad schrader or gasket in hose will cause u to get burned!
1/4 inch core depressors, 18$ on Amazon … thank me later
@@geoffi So what are the best gloves to grab? My coworker acted like I was weak for being nervous of being burned by refrigerant. But, I just felt there was a smarter and safer way to deal with the process. Please if you don't mind.... can you provide me with the exact gloves that are best for this? & a link to the field piece probes? I need both of these things if it will keep me from being burned. I have a coworker who's hands are literally stained with pale white skin burns and I prefer not to burn myself! Thank you so much man. Truly appreciate it!
@@geoffi my apologies i just read your other comment with all the information I needed and I highly thank you!!!!
They didn't write down the calculations for a job in a hotel with 4 vrv 3 units new compressor and boards
Great work. You do things the right way. Make some more videos ✌️
Thank you, I’m glad you enjoyed the video. I am planning on releasing more content soon as I have a few things in the works.
Any problems with the electric chute controls yet?
No issues yet, the snow blower has not gotten much use as this winter or the prior winter has been pretty light for snow fall. I did use it a few weeks ago and everything was working properly.
A featherboard for your table saw will help you keep those long cuts pressed next to the fence. Making your own drawers will save you a LOT of money.
I’ll have to look into getting one, yes I am sure you are correct. You can build your own for much less. Maybe I’ll give that a shot.
Nice TS ,
Thanks 👍
Travis- Is there anyone you can recommend that services Aaon units in Manhattan? Thank you.
If you give me a little more info I could probably give you a recommendation. Do you know what type of equipment it is? (I.E. packaged unit, split system, water sourced, chiller, etc.). Is this a commercial, residential, or production type facility?
Depending on certain variables, I may be interested in the service work. Let me know, thanks.