- Видео 137
- Просмотров 313 671
Blue Collar Handyman
Добавлен 6 окт 2022
Life of construction things #framing #electrical #plumbing #roofing #concrete #landscape #welding
Видео
How to Wire Receptacle, Switched Half-Hot Receptacle #housewiring #electrician #electrical #wiring
Просмотров 52Год назад
How to Wire Receptacle, Switched Half-Hot Receptacle #housewiring #electrician #electrical #wiring
Electrical for Bathroom Remodel #electrician #electical #housewiring
Просмотров 27Год назад
Electrical for Bathroom Remodel #electrician #electical #housewiring
Framing bowed or crown studs! King and Trimmer stud #framing #carpentry #shopbuild
Просмотров 85Год назад
Framing bowed or crown studs! King and Trimmer stud #framing #carpentry #shopbuild
Setting 40’ span Trusses with a Lift! Hang On #framing #carpentry #shopbuild
Просмотров 4 тыс.Год назад
Setting 40’ span Trusses with a Lift! Hang On #framing #carpentry #shopbuild
Metabo Hpt 18v Router Cutting window openings #framing #carpentry #shopbuild
Просмотров 142Год назад
Metabo Hpt 18v Router Cutting window openings #framing #carpentry #shopbuild
Can this also be done on a brick siding?
Love the song ⚡️🎧 watching it over and over 😂
It's estwing so it will hold up for a 100 yrs. Just soak the leather handle in neatsfoot oil every 15 yrs or so. 🇺🇸 💪
Kindergarten build
Why would you do it like that
Clown
Is that Acrylic Latex High caulk? Or caulking sealant your using?
The whole idea of me watching this video was to know how did you do it. Did you cut the studs at 5 degrees or you beveled the sill itself, if yes how?
What they charge to move one in California?
Wth you live that they still let you bond neutral to ground in the panel
I think I’d rather have the Type 2 external one as opposed to the circuit breaker type that you installed. From what I’ve seen they typically have a larger rating as far as the surge it can take is concerned
Nice!!! I have the Flycraft Stealth X. I love it! One of the best boats out there for fly fishing! I need to do this in my garage! 🙌
Wrong Section Table 310.16 assumes the use of 75-degree terminals, typical for all AC units. If the wire is THHN, it would be #14, rated at 25A. Consequently, per NEC 240.4(G), a #14 wire rated for 25 amps can be used.
I've had mine for over 3 years now. The leather wears to your hand, it only got more comfortable with time. Roofing and rain work has been a bit harsh on it, though. Some of the leather bands have split, so it's loose, im sure i could repair it but instead, im just going to buy another one. Best hammer I've owned. Especially for the price
I didn't know they made lifts rated to hoist loads!
What hoist system is this?
How about the 125% required for conductor sizing? Can we apply it to the minimum circuit current?
Already calculated in the Minimum Circuit ampacity
No... Doesn't work that way on nameplate ratings. You go by nameplate ratings on heating and air.
According to 440.12a1 the disconnect has to be rated at 115% and 440.32 single motor compressors- branch circuit conductors shall have an ampacity not less than 125% of the motor compressor rated load current
What about the 200volts?...wouldn't that be a 2phase?
No. No such thing as 200v or 2 phase on AC. Either 120 or 240v single phase. But There's 120/208v 3 phase. 3 wire at 120v. Phase to phase is 208v.
I guess they asked for it. Looks like 6/3 on a 50A? Tesla chargers don't use neutral connection and are rated @ 48 amps on max setting. So #6 has to be thhn to go on a 60A breaker since it's a continuous load. Or else #4 using nm cable.
Do you really need the expansion fitting on those short stub ups?
Thank you, I am learning a lot from your videos. My goal is to run conduits outdoor for a few cameras that are hard to run the cables inside.
What happens when your shut off switch is outside in a separate box?
Does your sheathing pattern matter? Like first piece is 8ft from bottom to slightly over the header then you start your next one.
Sick!🤙🏽
Hi. Is this for your shed?
This is what I need for my shed.
Love the look of a long line of scissor trusses! Nice garage.
I would strap the header and throw HTT5’s in each portal. I live in hirricane country.
According to Mike Holt, you can use 14awg on that unit. With a 20 amp breaker.
Not at all. Where does he state that? 17.1 amps would need a 12 gauge romex.
@@CryptoManiac1776 310.16 assumes 75-degree terminals and THHN 240.4 G says I can use a #14 rated at 25 amps.
@@anthonyjannace4410 gotcha I see. It’s rated at 20 though.
Stacked leather estwing tools are just fantastic. They hold up amazing. The reduce shock quite a bit. If you look how the inside of the handle is designed you’d see. Easy enough to replace the leather as well.
A tool like this should be $100
Well done Mac Gyver...
For some reason I still can't see it idk.
How Is The Shed Getting Power ?
Hey, what's that thing called that you screwed into the retro? Really handy
Missed opportunity to put rocker switches
You work in California
If you brought the load out of the gfci to the outlet for the sump pump, then it’s still on a gfci. If the interior on trips , the sump pump outlet will also trip.
From what he said I think he knows that he just wanted to put it inside so it doesn’t heat up like the outside one would
What @benzoVAL said, the pump needs to be on GFCI, he just didn’t want direct sun heating up the GFCI receptacle causing it to trip.
Is the EMT and armiflex code in your area or just something you wanted to do?
Авр не?)
I bet it would be hell getting those headers up with no equipment!
музыка говенная
What kind of mount is that. Is it customer provided ?
The make up on that panel is trash
Nice
Hi I am a truss designer, in my service I provide truss layout and design. also provide quantity takeoff for construction jobs i/c; MEP. Thank you
Wow, careful with the screws coming from the roof.
This was too ez. You didn’t hit a fire block
update
Nice. Let’s see Paul Allen’s wall setup
💋 Promo*SM