Bypass the Stupid F9 Error Code Oven Door Lock!!!
Просмотров 120 тыс.5 лет назад
Bypass the Stupid F9 Error Code Oven Door Lock!!!

Комментарии

  • @Tamara-id1pe
    @Tamara-id1pe Месяц назад

    Self clean is 800-900°F

  • @pjl_007
    @pjl_007 2 месяца назад

    Thank you so much for your video, it worked perfectly after discovering they dont make the replacement part anymore. Me and my 11 year old had a blast figuring it out and being succesful.

  • @USArmy91222
    @USArmy91222 2 месяца назад

    i have a Frigidaire Gallery oven that's locked in F9 error..i accidentally hit the clean button, now i can't get the F9 error code off and can no longer use the oven..after checking further, it looks like the motor that controls the door latch lock is seized and not working, which i believe is what caused the F9 error..mine has 1 red wire and 2 white wires that go directly to the motor..any idea how i can bypass this until i can get a new motor? the 2 white wires go to the same terminal and the red wire goes to a different terminal on the motor?

  • @pyts493
    @pyts493 6 месяцев назад

    I have a wall mounted kenmore oven model# 790.40523402 from 2007 This trick worked! BUT! the motor switch for our door lock was labeled NC NO and Common (pretty sure it was called common, it was obviously ground, on the opposite side of the other two wires) Initially I jumped the ground to the NO labeled wire, assuming the O stood for "Open". Didn't work, so I tried jumping to the NC wire, and that worked!!! I had to cut off female quick disconnects, then i stripped the wire a little and used a 2 wire Wago lever connector. It's all done and all good, I just made french fries to celebrate 🎉 Thank you.

    • @pyts493
      @pyts493 6 месяцев назад

      Edit: I reconnected the NO quick disconnect (had to crimp a new one on) back to the switch just so that if one day I want to repair the self-clean function, I'll know where the wires go. Also, in our case, lube wouldnt have fixed it. The plastic fitting that couples the lock motor to the lock rod had lost its internal "D" shape, so the motor's D-shaped output shaft could no longer rotate the rod, it just spun in the plastic coupling. So yeah! This was the go-to fix to avoid hunting down that plastic fitting on the internet and waiting forever for it to arrive (if I ever found a supplier).

  • @timwadebarrett
    @timwadebarrett 8 месяцев назад

    Man, thank you so much for this! I tried everything else resetting this punching this button doing this doing that bullshit so I run across your video and it works perfect. I'm not a big fan of safety crap anyway lol

  • @7adventcloud7
    @7adventcloud7 8 месяцев назад

    I just disconnected my door lock wires and it started working thx for the vid

  • @xthefella
    @xthefella 9 месяцев назад

    Thanks for this. Wish me luck.

  • @trmlundquist
    @trmlundquist 11 месяцев назад

    Thank you very much saved the day!!

  • @blackbird309
    @blackbird309 Год назад

    The only problem with this bypass is that the motor is going to activate if you put it into self clean mode and run the motor until the switch says the motor cam is in position, throwing it into error after a certain amount of time with the latch stuck.

  • @tomleszczynski2862
    @tomleszczynski2862 Год назад

    Friendly advice: the camera is way to shaky to pay attention to the video. You zoom in too close and for too long on things. Very informative but painful to watch.

  • @charlotterogers1182
    @charlotterogers1182 Год назад

    Very helpful, thanks .

  • @chrisdoss8553
    @chrisdoss8553 Год назад

    This wiring Method Works perfectly if you have a dump trailer that is power up and gravity down. If your trailer is Power up and gravity down you do not need the diodes. However If your trailer is power up and power down you will need To use the diodes. So in that case use the instruction video Which Instructs you to use the diodes.

  • @josephdaniel2097
    @josephdaniel2097 Год назад

    Just found that thing on my grandma's oven, unplug it and now it's working like a charm. Thank you my guy.

  • @tonyliguori2285
    @tonyliguori2285 Год назад

    Thanx for the tip. I'll try it, but "you talk too much"-(Thor to Thanos)-just saying

  • @geofftalbot9128
    @geofftalbot9128 Год назад

    CITYOF JESSE 2 years ago Don’t sit here and take your over apart: see if this works! 1. The door was locked shooting off that error F90 & some dr_00 2. I let it cool down didn’t fuss with it. 3. I hit the “Timer on/off” button and held it for a couple seconds (just for the hell of it.) and then I hit the OFF/hold button.

  • @commonsensepatriot9450
    @commonsensepatriot9450 Год назад

    Wow! Finally, it's a super simple description of how to do this. No diodes or complicated explanations. Thanks.

  • @christopherdougan3841
    @christopherdougan3841 Год назад

    Thank you so much homie. Parts are no longer available and it saved me 200$ to have a repair guy do what I just did for free!!!! 🙏

  • @erikyoung5139
    @erikyoung5139 Год назад

    I did something similar to bypass a broken lid switch on a top loading washer. Thanks for sharing.

  • @phillipmendez6536
    @phillipmendez6536 Год назад

    What should I replace to fix not bypass?

  • @richgenalski8639
    @richgenalski8639 Год назад

    thank u so much bro 🙏

  • @mitchplumlee3900
    @mitchplumlee3900 Год назад

    You are amazing 👏 ❤️. 3....different Maytag repairmen failed me. You saved me from buying new unit.!! My hero!

  • @dominicdinuzzo9945
    @dominicdinuzzo9945 Год назад

    With circuit off and oven unplugged. I sprayed oven cleaner in the latch area. Let it sit for 10mins. I tapped my door latch lightly with a hammer to close and open the latch 3x. Fixed my problem. Not sure it will fix everyone’s issue but thought I’d share.

    • @annesherwood1591
      @annesherwood1591 Год назад

      Dominic-Your comment was a lifesaver! I thought I needed to replace the part but I found your comment and decided to try your fix first! Totally worked... which is a huge lifesaver because it's Thanksgiving week and NOBODY has the part I need!

  • @hernandez660r
    @hernandez660r 2 года назад

    Something is not working for me

  • @adamdivine
    @adamdivine 2 года назад

    So I got this wired up today power up gravity down. How do I get power down? When I gravity down all of my fluid came shooting out of the reservoir cap.

    • @briangates8681
      @briangates8681 Год назад

      I agree this is a problem I don’t recommend the gravity down at all!! There is another video out that shows you how to do power down it uses diods it’s same harbor freight remote I’m doing mine now

  • @PNWTone
    @PNWTone 2 года назад

    Amazing. Very descriptive and slow and easy. Thank you

  • @stacyo2762
    @stacyo2762 2 года назад

    3 thumbs up from me dad and husband our oven has been stuck in f9 for a month found this Very Helpful Awesome Video and our Jenn Air oven is now Fully Functioning Thank You So Much

  • @RichardAgnewComGeek
    @RichardAgnewComGeek 2 года назад

    Great Video. Did you see this one? Amana Range Error Codes ruclips.net/video/a-EeIymEP1I/видео.html

  • @ElverGalarga58855
    @ElverGalarga58855 2 года назад

    ¡Es todo p¡nche culer0! Eres un mendigo dios!

  • @jacksonthomas5030
    @jacksonthomas5030 2 года назад

    Nice 😷 ? Can this same system work on single stage pump 😁

  • @bignix3490
    @bignix3490 3 года назад

    Or just yank the speaker out... problem solved

  • @filibertolopez3805
    @filibertolopez3805 3 года назад

    Thanks for the tip, you are a puto héroe 😂👍

  • @popapoco
    @popapoco 3 года назад

    You did it perfectly, you can also put a manual valve on the gravity down to slow the box when it has a heavy load or open the valve to allow more oil through when it is cold. I always thought gravity down was better but you hear everyone bragging about their power down lol good job

  • @Brewskin78
    @Brewskin78 3 года назад

    Hell yea! Thank you!!!!!!

  • @brycejcox
    @brycejcox 3 года назад

    I think you could have left the common where it was and just switched the other two around. Tomato to mato

  • @troyunderhill3588
    @troyunderhill3588 3 года назад

    Wired as you show but my pump motor surges on and off rather than maintain a constant lift. What’s causing this?

  • @brianvassar2556
    @brianvassar2556 3 года назад

    I would keep the wired controller in there In the moment you need it most the batteries in the remote will die

  • @skymap2347
    @skymap2347 3 года назад

    Thank you , works for my GE door motor

  • @laythalhamadani6022
    @laythalhamadani6022 3 года назад

    Thank you so much very helpful and appreciated

  • @michaelkennedy9794
    @michaelkennedy9794 3 года назад

    It is Easter weekend and Maytag oven bails because it does not want to work this weekend! This quick fix solved the problem. The actual part needed is no longer available so this was the great solution. My wife was a little bummed ☹️, as she was looking forward to new unit. Thanks for this video, saved me for now. Gas stoves/ovens like my wife wants cost several thousand dollars 💵 and not quite ready to purchase. Thank You!!

  • @PedroGarcia-tx9hr
    @PedroGarcia-tx9hr 3 года назад

    Awesome keep posting

  • @judithosborn1332
    @judithosborn1332 3 года назад

    But how did you release the door to access the screws to remove to stove top?

    • @bestgreenhomestead
      @bestgreenhomestead Год назад

      My problem exactly I can’t even pry it open

    • @snabbott
      @snabbott Год назад

      @@bestgreenhomestead I was able to slide a wire hanger in and catch the latch to open it. (Different model oven, but probably similar)

  • @NotMister
    @NotMister 3 года назад

    THANK YOU! I was attempting to broil and all of sudden the stupid code of death appeared " F-9 "code came on and now stupid oven won't work. I hope I can try your tips and have it work. Actually not me my husband..stupid program, stupid oven. Stupid stupid.

  • @scottparadise7339
    @scottparadise7339 3 года назад

    It’s the day before Christmas Eve and I got this error code. Thank you SO MUCH for taking the time to do this! 👍👍👍👍👍 You saved our turkey! Happy Holidays!!

  • @supernovapowa
    @supernovapowa 3 года назад

    This is the only workaround that worked. Thank you.

  • @rrf5336
    @rrf5336 4 года назад

    Just did this. WORKS!!!!!!!

  • @crox2000
    @crox2000 4 года назад

    Great fix, easy to do and probably saved me $500. You're a hero.

  • @waltkohler4030
    @waltkohler4030 4 года назад

    Bypass did not work, what next?

  • @timothycarey4629
    @timothycarey4629 4 года назад

    I have 2 30amp 4 pin relays it's power up and down but they back feeding when you hook up both i can get it to work gravity down but want power down can anyone help me please

    • @johnsandlinjr
      @johnsandlinjr 3 года назад

      Need some diodes buddy. Put diodes on the up and down jumpers over to the pump. Then it won’t back feed

  • @timothycarey4629
    @timothycarey4629 4 года назад

    How can i wire it with power up and down i have 2 relays i can use

  • @kyleturner3999
    @kyleturner3999 4 года назад

    Do you know what size the fuse is on the signal box?