Paradigm Cooling
Paradigm Cooling
  • Видео 11
  • Просмотров 37 237
How to use a valve core removal tool
Valve cores are some of the most restrictive parts in an HVAC system and in this video we show you how to use a valve care removal tool to remove those valve cores in order to speed up the evacuation and recovery processes.
Просмотров: 3 777

Видео

How to use a nitrogen regulator
Просмотров 19 тыс.2 года назад
This video is a step by step guide for how to safely use a nitrogen regulator
Flaring and swaging basics for copper tubing
Просмотров 8482 года назад
In this video we demonstrate the basics of flaring and swaging copper tubing using a standard flaring kit.
How to recover refrigerant from a HVACR system
Просмотров 6062 года назад
Refrigerant recovery is an important part of the HVACR system repair process. Here we walk you through an onsite recovery, highlighting all the pre-checks and preliminary procedures associated with this system critical skill.
JB Industries Vacuum Pump oil change
Просмотров 1,4 тыс.2 года назад
A step by step guide to changing the oil in your JB Industries vacuum pump.
Refrigeration Evacuation secrets I wish my lecturers told me
Просмотров 2212 года назад
In this video we give you useful tips for the effective evacuation of a refrigeration or air conditioning system. From valve core removal, to refrigerant hose permeation, we discuss the most fundamental aspects of the evacuation process.
Refrigeration Basics : How a refrigeration system works
Просмотров 2022 года назад
In this video we give a brief description of the basic functions of the refrigeration vapor compression cycle.
Refrigeration Trade Test Tasks : Testing a 3 phase electrical motor
Просмотров 7 тыс.2 года назад
As part of our series on Commercial Refrigeration Trade Test tasks, we give a detailed outline of the procedures for testing a 3 phase electrical motor. In this video Wesley demonstrates the step by step method for completing the trade test task that is a standalone task in its own right, as well as being part of the motor starter task required for attaining the commercial refrigeration red seal.
Samsung DVM S, E - 213 and E - 215 error code repair.
Просмотров 3,6 тыс.2 года назад
The team shows us how to correct a E - 213 error code and E - 215 error code on a Samsung DVM S smart heat recovery system.
Paradigm Cooling 9000BTU Midwall Split installation
Просмотров 1362 года назад
The team goes out to the southern suburbs in Cape Town to install a 9000BTU Daikin Inverter Midwall Split air conditioning system at a domestic residence.
An introduction to Paradigm Cooling
Просмотров 1162 года назад
An introduction to Paradigm Cooling

Комментарии

  • @minnthant1834
    @minnthant1834 26 дней назад

    E 458 error repair

  • @Alex-y2p5u
    @Alex-y2p5u 2 месяца назад

    great video thanks

  • @PrabakaranN-d9u
    @PrabakaranN-d9u 3 месяца назад

    Will nitrogen cylider blast if regulator is not connected properly..? How to avoid this..? Pleasee reply

    • @paradigmcooling8497
      @paradigmcooling8497 2 месяца назад

      Hello. The nitrogen cylinder won't explode, but incorrect use of the regulator can cause an explosion outside of the cylinder. You can avoid this by making sure that the regulator is properly connected to the cylinder, without any leaks, and make sure that the pressure setting on the regulator does not exceed the safe operating pressure of the vessel that the nitrogen is being fed into. You can consult the manufacturer's specification literature for specific values.

  • @michaelamay9714
    @michaelamay9714 4 месяца назад

    Whats the difference between the left gauge and right gauge?

    • @paradigmcooling8497
      @paradigmcooling8497 3 месяца назад

      Hi Michael. The left gauge shows the pressure leaving the regulator, while the right gauge shows the pressure in the cylinder.

    • @michael931
      @michael931 12 дней назад

      ​@@paradigmcooling8497 why does the right hand gauge always show 0 PSI in the video?

  • @makhadzimakhams2419
    @makhadzimakhams2419 4 месяца назад

    Can you also add single phase motor test

    • @paradigmcooling8497
      @paradigmcooling8497 4 месяца назад

      Hi Makhadzi. That's a great idea. We have added it to our list of requests.

  • @jalicecopeland5407
    @jalicecopeland5407 8 месяцев назад

    How do you check to see how much pressure is inside before using ?

    • @paradigmcooling8497
      @paradigmcooling8497 6 месяцев назад

      Hi Jalice. The nitrogen regulator has two gauges fitted to it. One gauge reads the pressure in the cylinder and the second gauge shows the output pressure of nitrogen leaving the cylinder. In order to see how much pressure is in the cylinder, you simply have to open the cylinder with the t-style handle on the regulator still closed (as per normal operating procedures), and the high pressure gauge reading will rise to represent the cylinder pressure. The low pressure gauge should show zero at this point with the regulator still being closed. In this video, you will notice that the cylinder pressure is very low, hence the high pressure gauge showing very close to zero.

  • @joeoehm4341
    @joeoehm4341 8 месяцев назад

    Can I use the Schrader valve core remover right at the beginning? For new systems, practically BEFORE evacuation? For older systems, in cooling mode, but still switched off (there is a slightly pressure).

  • @DavidMoloi-y4m
    @DavidMoloi-y4m Год назад

    Thank you for the info. Can you please post the rest of the tasks.

    • @paradigmcooling8497
      @paradigmcooling8497 11 месяцев назад

      Thank you for your comment. We will be uploading the video on the efficiency test on a compressor in the next week or so.

  • @safetyalways7788
    @safetyalways7788 Год назад

    What did you connect the yellow hose from the valve core remover tool to?

    • @paradigmcooling8497
      @paradigmcooling8497 Год назад

      Hi @safetyalways7788. The yellow hose on the video is connected to my digital vacuum guage. Now it is important that the hose used be rated for vacuum, or alternatively just use a Micron Coupler, which is the industry best practice right now.

    • @safetyalways7788
      @safetyalways7788 Год назад

      @@paradigmcooling8497 ok

  • @garrybaker6485
    @garrybaker6485 Год назад

    This is the best video made on the topic. Appreciate you. My only question at this point - the manufacturer specifies pouring oil down the vacuum inlet port during the oil change. Can you demonstrate that part of the process?

    • @paradigmcooling8497
      @paradigmcooling8497 Год назад

      Thank you Gary. Yes the charging of oil through the vacuum inlet port is an important part of the oil flushing process when the replaced oil is badly contaminated and we should definitely do a video on the process. Thank you for the suggestion and we will certainly add it to our production list.

  • @amgari007
    @amgari007 Год назад

    Thank you for the video. I have an argon/co2 regulator .Can I use it with nitrogen since fits to tank if I change the left low gauge to 100-600 psi one? Thanks.

    • @paradigmcooling8497
      @paradigmcooling8497 Год назад

      That's a very good question. Conventional wisdom suggests that you could theoretically use an argon/co2 regulator for nitrogen applications provided that the fittings match the cylinder being used and that the maximum pressure threshold of the gauges is sufficient to manage the cylinder pressure. You could of course add additional adapters and fit new gauges to make the regulator compatible, but my personal preference is to use the correct regulator for the gas it was originally designed for. It is also worth a mention that the pressure regulation legislature in your country may prohibit such modifications under its safety laws. I would research them thoroughly before making any changes to the equipment. thank you for your question and be safe.

    • @amgari007
      @amgari007 Год назад

      @@paradigmcooling8497 Thank you very much for the reply. Best regards.

  • @candidoespinal2466
    @candidoespinal2466 Год назад

    Can you do a video pulling a vacuum with this pump on a condenser coil

    • @paradigmcooling8497
      @paradigmcooling8497 Год назад

      Yes we have a video in the works that involves a vaccuum decay test on a condenser, using this exact pump, which may be what you are looking for.

  • @lugongguo8125
    @lugongguo8125 Год назад

    Thanks for sharing the video. I will test pressure gauges with a nitrogen cylinder and regulator valve with an increase and decrease dial not a handle like yours. Do I have to turn the dial to the decrease side all the way before I open the shut-off valve of the cylinder? or it doesn't matter. Any safety tips? After I test each pressure gauge, do I have to shut off the cylinder? Thanks again. 👍

    • @paradigmcooling8497
      @paradigmcooling8497 Год назад

      Hello there. Yes it is best that you leave the regulator closed all the way before opening the cylinder. This is just to make sure that the pressure coming through the line doesn't exceed the maximum pressure tolerance of the guage that you are testing. You can gradually open the regulator until you get to the desired test pressure. Also, if you are testing multiple guages then it isn't necessary to close the cylinder after each test. You can just close the regulator after each test until all the tests are complete. Upon completion of all the tests, you can then close the cylinder as a final step.

  • @damienlb3551
    @damienlb3551 Год назад

    Does the regulator have to be shut before opening the cylinder valve ?

    • @paradigmcooling8497
      @paradigmcooling8497 Год назад

      Yes, it's best to do it that way in order to properly regulate the pressure coming out of the cylinder. It allows you to slowly raise the pressure to the desired level without the risk of rupturing the system being filled. I have seen a technician pre-set the regulator for a pressure test on an evaporator and upon opening the cylinder, the evaporator immediately ruptured because a part of system was weakened due to wear and tear. Luckily no one got hurt but the bang quickly cleared the building. Lol

  • @joaobandarra5044
    @joaobandarra5044 2 года назад

    You have the eva in thermistor damaged in the unit 13

  • @ediwardyeremia7916
    @ediwardyeremia7916 2 года назад

    Excellent tutorial , we need more boss

  • @30mAkills
    @30mAkills 2 года назад

    Excellent tutorial. It would have been more useful if you have provided meggering tip for thermistor protected motors.

    • @paradigmcooling8497
      @paradigmcooling8497 2 года назад

      That is a great tip, thank you. We will definitely look at making that video in the near future....

  • @andrzejbowhall2170
    @andrzejbowhall2170 2 года назад

    I'm going to check out your channel now! New fan :). Easy video ranking > P-R-O-M-O-S-M!!