Видео
repair Ultrasound transducer , cardiovascular probe
Просмотров 330Год назад
repair Ultrasound transducer , cardiovascular probe
dissaembly samsung HS40 ,board BE+ CPU+ card VGA
Просмотров 165Год назад
dissaembly samsung HS40 ,board BE CPU card VGA
Điện tử căn bản-Chức năng các thang đo trên đồ hồ số vạn năng (VOM)
Просмотров 78Год назад
điện tử căn bản,điện tử thực hành,điện tử ứng dụng
test Getinge classic 2, board LCD+controller
Просмотров 44Год назад
test Getinge classic 2, board LCD controller
repair suzuken ECG-306-test with simulator full option.
Просмотров 95Год назад
repair suzuken ECG-306-test with simulator full option.
ultrasound machine samsung sonoace R3 cpU board error, no screen display/ R3 lỗi bo cpu.
Просмотров 481Год назад
máy siêu âm samsung sonoace R3 lỗi bo CpU,không hiển thị màn hình/ultrasound machine samsung sonoace R3 cpU board error, no screen display
16-slice ACT Revolution CT Scanner error Link disconnect.Fix it.
Просмотров 2962 года назад
16-slice ACT Revolution CT Scanner error Link disconnect.Fix it.
ultrasound ALoka Alpha 6 error "TP command timeout" ,fix it.
Просмотров 1 тыс.2 года назад
ultrasound ALoka Alpha 6 error "TP command timeout" ,fix it.
CT scanner Siemens Somatom scope 16 slices-detail.
Просмотров 3612 года назад
CT scanner Siemens Somatom scope 16 slices-detail.
Check error CTscanner :Siemens Med Service software.
Просмотров 1662 года назад
Check error CTscanner :Siemens Med Service software.
Repair board AC/Dc Power supply ultrasound Samsung Medison R7/sửa nguồn siêu âm samsung R7
Просмотров 8033 года назад
Repair board AC/Dc Power supply ultrasound Samsung Medison R7/sửa nguồn siêu âm samsung R7
License -ultrasound samsung Medison R3-R5-X6
Просмотров 1,8 тыс.3 года назад
License -ultrasound samsung Medison R3-R5-X6
hướng dẫn sửa remote tivi 1 cách nhanh nhất.ai cũng làm dc.
Просмотров 3,3 тыс.3 года назад
hướng dẫn sửa remote tivi 1 cách nhanh nhất.ai cũng làm dc.
Instructions for checking and fixing power supply of Ultrasound Samsung Medison R7.
Просмотров 1,3 тыс.3 года назад
Instructions for checking and fixing power supply of Ultrasound Samsung Medison R7.
Hướng dẫn kiểm tra siêu âm Medison R3/Instructions for checking and repairing ultrasound Samsung R3
Просмотров 5503 года назад
Hướng dẫn kiểm tra siêu âm Medison R3/Instructions for checking and repairing ultrasound Samsung R3
Cpu X6 medison Switch to Cpu R3 (ultrasound)
Просмотров 4033 года назад
Cpu X6 medison Switch to Cpu R3 (ultrasound)
Repair power suply ultrasound Samsung Medison R7 error OLP,OVP…All error
Просмотров 1 тыс.3 года назад
Repair power suply ultrasound Samsung Medison R7 error OLP,OVP…All error
Test Motherboard cpu ultrasound Hitachi Aloka F37.
Просмотров 6083 года назад
Test Motherboard cpu ultrasound Hitachi Aloka F37.
Disassembly Phased-array ultrasound transducer /tháo và thay chấn tử đầu dò tim máy siêu âm
Просмотров 5003 года назад
Disassembly Phased-array ultrasound transducer /tháo và thay chấn tử đầu dò tim máy siêu âm
disassemble ultrasound probe extreme teardown (new)
Просмотров 9433 года назад
disassemble ultrasound probe extreme teardown (new)
ultrasound probe and transducer repairs/thay chấn tử đầu dò siêu âm.
Просмотров 5813 года назад
ultrasound probe and transducer repairs/thay chấn tử đầu dò siêu âm.
U have power supply h60 samasung
Hello sir i have x6 model can help i fix it..small screen and the big monitor cannot display..not funtion
Bên mình có sửa máy nội soi tai Mũi họng không
I m having issue same model
Hello can you help me to repair the cpu for mylab x5-x6??
Please let me know the type of oil for refill and where I can get bladder for oil thanks
زيت الة الخياطة اصفر اللون
Mylab x5 ultrasound need activation code do you have it sir ?
My brain CT protocol page for Siemens Sensation 16 Syngo 2006 software shows values for topogram (only kvp,csl.tı) and base. The DLP given for the base matches the total DLP. In dose report pages, I observe "head" instead of "base," and Siemens 16 sensation guide indicates separate ranges for base and cere. My slice thickness is set to 0.75 mm and 4.5 mm. The scan was performed with 2 ranges, but can the protocol page show only "base"? Since there's no value for cere, and both DLP and CTDI vol for cere are missing, I understand the total DLP could be larger. Is it possible that the scan was performed only with "base," leading to "base" being displayed on the protocol page and DLP and Ctdivol values are for all entire scan? and are the values on the protocol page generated by the machine during the scan? Thank you
I want to contact with you.... Please sent me... Contact info
I think so BF Board issue I am a right sir
yes, sir
Great job sir ...board leval repairing
I wonder why an idiot would post a video showing him measuring some voltages, and stating he is fixing 12V error.
Hello sir , I have the same problem, the device work but scanning port not signal massage appear , the screen LCD have no problem I did test it in another device , but the problem is related to cpu board can u help me with it .
ok,please remove the cpu board and BE board, i will guide you to repair it
@@healthcaretv5312 thank u so much , I will try to remove them and contact you for helping me as soon as possible
@@healthcaretv5312 hello sir , I did remove the cpu and be boards, can u guide me to repair it ?
@@healthcaretv5312 hi sir.... My esaote mylab x6 cannot on... Can you guide me to repair it?
Hi. does the fan of power supply always work? I have a affiniti 50 power supply that doesn't work and I have checked the fan and it's intact.
Hello, I want to ask you something about ultrasound probes. how can I reach you
Comment faire pour le procurer ?
help plz wat type of oil is that
Anh ơi. Có thể làm 1 video đầy đủ về dựng hình 4D máy aloka 3500 được không ạ? Sao e thấy trong video này ,a không dùng roi ạ
How to use roi in 4D ?
Donde consigo el software del medison sa8000
si lo conseguiste
Anh ơi, cho em hỏi là cái dây cáp c5-1 kia độ dài là bao nhiêu vậy ạ?
Mình không để ta nữa khoảng 2m5
Please any idea related to prob tester board
And crystal required..
i have a problem if you can guide me please : power on for 5 sec only and shutting down , cant poot up
Hi, did you solved the problem? I have the same Samsung and I didn't figured out...
@@ion0bad no not yet
@@TestTest-rj9fb I think the problem lays in DDM (dc to dc module), there is I2C communication between PC board and power source via SCL, SDA and INT lines from a Atmega MCU inside DDM
Do you offer any course about probe repairing? What is the cost?
Probr killer
hello. When i click on power button machine start and i hear beep sound 4 time. 15 second later machine shutdown. 10second later again start and again 4 beep sound again again same things. Please let me know what should i explore?
Hey what is up next?
Hello, I really aprecciatte your work, do you have any Nihon Kohden to sell?? I´m really interested
Please let me know the type of oil for refill and where I can get bladder for oil thanks
Hi I wanna know the type of oil in the bladder.thanks
salah did you find the liquide
Can I buy a training course, please?
Giá máy bao nhiêu ạ
A liên hệ 0916252136 Đăng giúp em
Anh trai biết sửa s5-1 cw noise cho epiq philips không anh?
bị gì ạ,đem qua mình ktra hỗ trợ cho anh
Mình cũng nghề đây nhưng ko ở Việt Nam mình đang ở mỹ. Channel board của cái epiq bị prode S5-1 cw noise ở giửa mà ko biết sao hết. Thay con chipper rồi mà cũng ko hết. Có gì mình trao đổi được ko bạn ơi. Mìn làm prode với tất cả luôn. Cảm ơn bạn reply nha
have you solved the problem i strongly sggest that you chech surounding interferance espacialy if this happens only with convex probe the chek transformers inside and all electrical connections there must be some electrical leakage lets hope its not beamforming error
power suply & boad BF error,no problem with probe
New Transformatoren was switched 110v but installed 220v. It caused some little exposion. Can i repair it?
yes, no problem
Dụng cụ làm chảy chì lúc tháo anh dùng là gì v ạ
à đó là chì xả nha bạn
Very interesting and helping video. I am interested in repairing probes. Can you please tell me if a 4D GE probe loses some liquid (oil), what liquid should i use to replace it?
Yes,i can help you.
@@healthcaretv5312 hi I wanna know something about oil and bladder
hello any one knw the oil is wat
What is the price of refubshied monitor nihon kohden BSM2301K
cho e cái
2tr8 mua mới
What kind of material do you put on the top of the probe? Can you email me a tutorial? It would be a great help to me. gerardo600@gmail.com
Hi
M có 1 con như này, bật màn hình siêu âm bị trắng xóa là do lỗi gì vậy ad?sửa đc ko?
Sửa dc a,máy a bị trắng màn hình cảm ứng hay màn hình trên a,với a ở đâu ạ
@@healthcaretv5312 bị màn hình siêu âm thôi, màn hình cảm ứng vẫn lên ạ,nếu sửa giá hết tầm bn vậy ad?
@@hanhhoang8939 a ở đâu ạ,sửa hết khoảng 10-15tr a,tùy khu vực
Hiện tại máy bên e ko lên nguồn rồi add ạ, bên a nếu sửa đc liên hệ e 0967146784
Nhân tiện cho e hỏi là máy có thể nâng cấp hay thêm chức năng doppler đc ko?
Mình có cái đang mất nguồn nè, sữa dùm nha
ok anh,gui em lam giup cho
@@healthcaretv5312 cho anh thông tin liên hệ nha
@@tongphan1417 0904184517 em tên Bảo