Replacement of old and leaky R22 refrigerant coil and condenser to R410 System,
I just did the best upgrade! 🙌🔥 I replaced a leaky R22 equipment with a nice R410 system! 💯💨 Trust me, this improvement is game-changing! 😎✨ No more leaks and much lower electrical bill for customer, 
Просмотров: 921

Видео

How to replace the first company fan coil blower motor, and cleaning of the indoor coil,
Просмотров 5784 месяца назад
On this video, I show you how to change the motor and how to clean the coil
Commercial package unit blower motor fan won’t turn on, and the system is frozen!
Просмотров 1964 месяца назад
In this video, I show how to replace a bad blower motor on a commercial package unit, also a complete service include cleaning the coil, and changing a GFI
 why the furnace is blowing cold air, and the flame is not coming on
Просмотров 10911 месяцев назад
www.toptestools.com/ TOPTES leak detector
How to install H series- Horizontal discharge module link heat pump STD ECM kit
Просмотров 261Год назад
Installation of field kit  and H series horizontal discharge modeling heat pump STD ECM come through to Bility kit HMH7AK001/S1/HMH7AK001
How to install smoke detector for commercial building HVAC -parts 3
Просмотров 333Год назад
 Complete the wiring and Installation of contractors 
Recommend tools for HVAC Technician and Installers
Просмотров 266Год назад
Answering your questions about tools that I recommend for new HVAC technician and installers
How to install smoke detector for  commercial building, HVAC- part 2
Просмотров 517Год назад
Smoke detectors waiting for two
Duct Smoke Detector Installation for commercial building, HVAC - part 1
Просмотров 996Год назад
Installation of smoke detectors in commercial building part one
Not what I was expecting to do
Просмотров 257Год назад
Changing a Roof Top Heat Pump package System with opposite return and supply opening 
Commercial HVAC Ductwork
Просмотров 407Год назад
Installation of spiral pipe in commercial building 
Beware of crappy air-conditioning job
Просмотров 278Год назад
Very wrong way to install heating and air conditioning system in commercial building
Service call from a subscriber!
Просмотров 257Год назад
The Heating and Air conditioning system had a foul chemical odor; we cleaned the system, repaired the ductwork, and disinfected the system
Undetectable Leak on the Heat Pump Condenser
Просмотров 275Год назад
We tried every way to find a leak in the condenser but we couldn’t, and the Conclusion we came with is to change the system.
Flameless furnace pilot????
Просмотров 223Год назад
How to diagnose a furnace when endorsing motor comes on pilot comes on but you didn’t get no flame watch the video
The Damages of Hiring Unprofessional HVAC Services
Просмотров 2,8 тыс.2 года назад
The Damages of Hiring Unprofessional HVAC Services
What does the (FO) code on Frigidaire mini split Air Conditioning display indicate?
Просмотров 4,8 тыс.2 года назад
What does the (FO) code on Frigidaire mini split Air Conditioning display indicate?
Worst HVAC Job I ever seen
Просмотров 8492 года назад
Worst HVAC Job I ever seen
Convert R -22 Heat Pump First company fan coil to R-410
Просмотров 3252 года назад
Convert R -22 Heat Pump First company fan coil to R-410
How do you know your HVAC Job was done professionally?
Просмотров 4612 года назад
How do you know your HVAC Job was done professionally?
Commercial Building HVAC Installation
Просмотров 5142 года назад
Commercial Building HVAC Installation
Who won the raffle - April 10,
Просмотров 1052 года назад
Who won the raffle - April 10,
Heat pump condensation line complete installation
Просмотров 6352 года назад
Heat pump condensation line complete installation
How to install Air handler in the attic new construction
Просмотров 20 тыс.2 года назад
How to install Air handler in the attic new construction
Giveaway! Win a prize! See description for rules!
Просмотров 1552 года назад
Giveaway! Win a prize! See description for rules!
When the customer doesn’t have money to pay for complete HVAC installation
Просмотров 5322 года назад
When the customer doesn’t have money to pay for complete HVAC installation
Repair of commercial HVAC equipment
Просмотров 6752 года назад
Repair of commercial HVAC equipment
A big issue with brand new furnace blower motor
Просмотров 2652 года назад
A big issue with brand new furnace blower motor
furnace, coil installation and brazing the refrigeration lines
Просмотров 5612 года назад
furnace, coil installation and brazing the refrigeration lines
New construction HVAC installation part 2
Просмотров 2,3 тыс.2 года назад
New construction HVAC installation part 2

Комментарии

  • @MarkChaney
    @MarkChaney 13 дней назад

    doersnt hanging the air handler like that allow movement, which means it could move when getting worked on or whatever and tear away from the plenum?

  • @dannydelgado8181
    @dannydelgado8181 17 дней назад

    Great job 👌

  • @bruce8572
    @bruce8572 29 дней назад

    What hackery! Using a Vice-grip pliers............!!

  • @Ivan_2017_
    @Ivan_2017_ Месяц назад

    We can not hear 👂 anything

  • @gt-cr5mk
    @gt-cr5mk 2 месяца назад

    Where i can find that air piston? Can you put a link? Thanks

  • @korkhFUCK
    @korkhFUCK 2 месяца назад

    Looks great! What’s that telescopic lift you guys use for lifting equipment in the attic? I’d love to have one of those, thanks for the info.

  • @Hvacnc
    @Hvacnc 2 месяца назад

    Can you show how to get roof curb measurements. ( I know that depends on S and R dimensions of the new unit.)Also running square duct on finished roof

  • @jackalay23
    @jackalay23 4 месяца назад

    Well you should have started with telling folks to never locate an air handler in the attic of new construction.

    • @waisHVAC
      @waisHVAC 4 месяца назад

      I am not sure where you got this information from ? that you can not install air handler in the new construction?

    • @jackalay23
      @jackalay23 4 месяца назад

      @waisHVAC no you can install it there, sure. It's just a horribly inefficient place to put an air handler and ductwork. Modern efficient design practices always place the air handler and ducts within the building envelope. And from an installers point of view, would you rather service a unit in the attic or inside the living space?

    • @waisHVAC
      @waisHVAC 4 месяца назад

      Efficiency nothing to do where you installing the system? to measure the efficiency of central air conditioning and heat pumps. It's calculated by dividing the total cooling output (in BTUs) by the total electric energy input (in watt-hours) over a typical cooling season,

    • @jackalay23
      @jackalay23 2 месяца назад

      My man, if you think locating air handlers and ducts in the attic does not negatively impact system performance and efficiency, you need to get some remedial training.

    • @waisHVAC
      @waisHVAC 2 месяца назад

      @@jackalay23 Mr. Jack, can you send me the info where you found that information because in 30 years, me and million other HVAC contractors installed so many air handlers in the attic. We should all go and sue the manufacturer for making horizontal air handlers for attics,

  • @henrybucki7813
    @henrybucki7813 4 месяца назад

    why did yall not use rubbertex glue and then tape the joints? also r22 txv on coil and you are running 410

    • @henrybucki7813
      @henrybucki7813 4 месяца назад

      did you check the condenser for another factory installed liq drier.

    • @waisHVAC
      @waisHVAC 4 месяца назад

      Where did you see R 22 TXV? That was on old unit , We installed brand new R 410 coil, and why I use glue? It’s not a commercial project with 50’ expose pipe on the roof, we had only 2 feet expose, pipe and UV tape is approved by building and safety and it looks very neat and clean

    • @henrybucki7813
      @henrybucki7813 4 месяца назад

      i saw it on the original coil. didnt watch till the end where you replaced both the coil and the cond unit . i also used pvc pipe to run the refrigerant lines in. i started ac repair in 1972 after vietnam later worked for hussmann for 30 years later owned my on company doing grocery store repairs in ga

    • @waisHVAC
      @waisHVAC 4 месяца назад

      @@henrybucki7813We use Henry UV white glue on commercial buildings, if the line set is over 10 feet long, for short pipe it’s clean to use tape instead of using glue and you don’t want to drip the glue on the concert especially in house like that ,

  • @nshanaboolian172
    @nshanaboolian172 4 месяца назад

    Hi .You have no X13 ECM motor so you do not need to install the kit for this specific air handler. You installed the low end air handler with PSC motor which gray and black wires are low voltage and cannot be hooked up on PSC motor speed taps.

    • @waisHVAC
      @waisHVAC 4 месяца назад

      Yes, you do. That’s recommended by the manufacturer, you can contact York and ask them pimmedia.winsupplyinc.com Or google it Field Kit Installation Manual: H Series - Horizontal by the way, we have to do what the manufacturer recommends because of the warranty, in case something happen, fan control kit comes with the package, and it’s not extra things that I’m adding,

  • @sadsamr-un8rl
    @sadsamr-un8rl 5 месяцев назад

    عملا رائع شكرا على جهودك المبذولة لايصال المعلومة المفيدة لنا عن هذا الجهاز المتعب في صيانته

  • @BenDaijo
    @BenDaijo 5 месяцев назад

    Informative , thanks

  • @vladmir3203
    @vladmir3203 6 месяцев назад

    Good job, usta!

  • @alvincee7605
    @alvincee7605 6 месяцев назад

    ❤❤❤

  • @bagnerpaz3021
    @bagnerpaz3021 8 месяцев назад

    Each unit hav contactor you no need this

    • @waisHVAC
      @waisHVAC 8 месяцев назад

      Thank you for comment, but unfortunately, I had to follow the mechanical plan and design provided to us by the mechanical engineers and that’s how they want it ,As I explain, there’s more things will be connected to those contactors , like kitchen hood, sprinkler system and bathroom exhaust fans, because the bathroom fans are over 500 CFM , and the entire system will be controlled by the management computer systems

    • @waisHVAC
      @waisHVAC 8 месяцев назад

      One more thing for you information you don’t connect the smoke detector to AC contactor that will not shut off the blower you have to connect it to the 24 volt wire goes to the board to shut off the entire system not just a compressor.

  • @brandoncorrea511
    @brandoncorrea511 9 месяцев назад

    Do more light commercial work plans.

  • @joecox9958
    @joecox9958 9 месяцев назад

    Nice and thanks - noise of course! what kind of the anchor nut you used? is it like swing?

  • @erikcable1755
    @erikcable1755 9 месяцев назад

    Too bad no one can hear you talk(they do sell microphones) pro tip here...

  • @AlehaQuintero88
    @AlehaQuintero88 9 месяцев назад

    How you hang the air handler ? What you use ??

  • @dwaincorry4592
    @dwaincorry4592 11 месяцев назад

    Where is the auxiliary pan?

    • @waisHVAC
      @waisHVAC 11 месяцев назад

      Under the Air handler

  • @dwaincorry4592
    @dwaincorry4592 11 месяцев назад

    No auxiliary drain

  • @MariosACandRefrigeration
    @MariosACandRefrigeration 11 месяцев назад

    You are checking with the blower cover off,and checking co2 level ?,but i am afraid you have a cracked heat exchanger.you did not check for that.thanks for posting.

  • @lilziv1219
    @lilziv1219 11 месяцев назад

    Hey Sir I was just wondering as a person just getting started with HVAC should I refine into sheet metal or Technician side of HVAC? Thank you so much!

    • @waisHVAC
      @waisHVAC 11 месяцев назад

      Hi congratulations and welcome to HVAC business world, definitely it is up to you and your capabilities sheet metal work and installation is easy to learn and there will be always jobs demand for good Installers but being a Technician I will definitely suggest you to take HVAC classes, it’s harder to find job unless your a very experienced technician, and if you can do both it will be better for you, Good luck

    • @lilziv1219
      @lilziv1219 11 месяцев назад

      @@waisHVAC Thank you sir I appreciate the advice. This is my second year in university at the moment I wanna either drop out or take it part time and do full time apprenticeship with HVAC I have a few interviews coming up on the sheet metal side one commercial one residential. I did wanna do technician and get into refrigeration side of things but realized companies don’t hire non experienced technicians I would need to do a semester of college also I been hearing technicians within companies don’t have much hours whereas installing you always have an opportunity.

  • @johne4230
    @johne4230 11 месяцев назад

    Why don’t you use impact drill with socket attachment for the lag bolts??

    • @waisHVAC
      @waisHVAC 10 месяцев назад

      Unfortunately I don’t had the socket box with me that day, I know it was annoying to tight the lag bolts with wrench,

  •  Год назад

    would this be the same for a gree model? we hooked up coolbot to it and now getting f0 code

    • @waisHVAC
      @waisHVAC Год назад

      Most likely it’s low in refrigerant or Malfunction of indoor ambient temperature sensor at air return port

  • @AlexanderGolembewski-pt9nm
    @AlexanderGolembewski-pt9nm Год назад

    Wiring the overflow to the condenser wire is a great idea, but how does that help if you also use your condensation pump for your furnace humidifier? Your idea works great for summer ac, but could lead to a disaster in the winter when using the furnace. Please correct me if I am wrong.

    • @waisHVAC
      @waisHVAC Год назад

      Then you break the red wire (24 V ) the all furnace will go off

    • @waisHVAC
      @waisHVAC Год назад

      For humidifiers or furnaces you connect the the pump wire to the red wire (R)

  • @staycompassionate3811
    @staycompassionate3811 Год назад

    Hi, can I compensate you for an apprenticeship?

  • @hammadelectronics5441
    @hammadelectronics5441 Год назад

    Nice work sir, plzzz mintion contact number

    • @waisHVAC
      @waisHVAC Год назад

      You can send me email at Waisheatingandair@gmail.com

  • @Gabriel_chicken
    @Gabriel_chicken Год назад

    What size breaker was that condenser on and was it grounded properly?

  • @jaybro1046
    @jaybro1046 Год назад

    Do you have more information about Chinese brand manifold gauge duoyi? Model number something like it . Thx

    • @waisHVAC
      @waisHVAC Год назад

      Yes I will post it for you

    • @waisHVAC
      @waisHVAC Год назад

      Ball Valve Digital Manifold pressure tester Duoyi model DY522A

    • @jaybro1046
      @jaybro1046 Год назад

      @@waisHVAC thank you

    • @waisHVAC
      @waisHVAC Год назад

      www.duoyitool.com This is the company website

  • @keontaytarver3534
    @keontaytarver3534 Год назад

    👍

  • @keontaytarver3534
    @keontaytarver3534 Год назад

    👍

  • @randypaul5427
    @randypaul5427 Год назад

    Great job! Very enjoyable to watch.

  • @hernandezidaul8493
    @hernandezidaul8493 Год назад

    Hey man are you hiring , I’m in the field as well. Always looking to learn more.

  • @keontaytarver3534
    @keontaytarver3534 Год назад

    Greetings u haven't post in awhile

    • @waisHVAC
      @waisHVAC Год назад

      We will have very interesting jobs and videos coming soon

    • @keontaytarver3534
      @keontaytarver3534 Год назад

      @@waisHVAC k I'll be on the lookout

  • @williamjohnson1744
    @williamjohnson1744 Год назад

    Will you do a video showing rtu curbs and how you fasten the units for wind and seismic codes? Thanks!

  • @sncruiser
    @sncruiser Год назад

    Did you flush the line set and evaporator of old oil?

    • @waisHVAC
      @waisHVAC Год назад

      Of course with Co2

  • @jaimebonilla7750
    @jaimebonilla7750 Год назад

    That’s sloppy ductwork

    • @waisHVAC
      @waisHVAC Год назад

      Go play with your toys 🧸

  • @ronaldrosales8790
    @ronaldrosales8790 Год назад

    great video

  • @Junkawayllc
    @Junkawayllc Год назад

    I prefer duct mastic around connection, then inner spiral, then tape, then cable ties. You can spilt the insulation and cut duct shorter to allow enough insulation left to insulate Wye.

  • @javierlozano752
    @javierlozano752 Год назад

    Hey guys I’m 23 years old and I’m 5 months in on my HVAC career but I have a question how do you determine the size of the return and supply plenum? I asked other people I worked with and some say they don’t know others just don’t want to tell me

    • @waisHVAC
      @waisHVAC Год назад

      You have to calculate the return and supply duct size based on the CFM of the unit. For example, if you have a 2 Ton system which is 800 CFM, you calculate the size of the duct based on 800 CFM, And you will need a duct design calculator, to find what size of duct you will need to give you 800 CFM return and supply, I hope that helps God bless

  • @happybearinc.9083
    @happybearinc.9083 Год назад

    Is this a foam roof?

  • @voided738
    @voided738 Год назад

    What power tool brand would you recommend? I just got into commercial hvac mainly installs and I’m loving it. Not sure what a good brand would be to invest in long term that can handle getting beat

  • @Dojautlopez
    @Dojautlopez Год назад

    I do the 45 but I always install safety switch off the secondary on the coil to ensure the system shuts down before flood

  • @WelcometoKabul
    @WelcometoKabul Год назад

    👍🏽👍🏽👍🏽

  • @keontaytarver3534
    @keontaytarver3534 Год назад

    👍

  • @happybearinc.9083
    @happybearinc.9083 Год назад

    I hear you, brother. I've been seeing a lot of nasty and dirty jobs. From other contractors.

  • @HVAC304
    @HVAC304 Год назад

    I'm ac technician

  • @akeemhoque5976
    @akeemhoque5976 Год назад

    Thank you sir I was looking for a video just like this.

  • @Mike-nl5br
    @Mike-nl5br Год назад

    Brother better wear a mask

    • @waisHVAC
      @waisHVAC Год назад

      You’re absolutely right I’m a little bit careless when it comes to safety but thank you anyway,