Air Change
Air Change
  • Видео 13
  • Просмотров 222 083
The Digital Scroll Compressor - Improved Capacity Control But Is There a Downside?
The digital scroll compressor is a form of scroll compressor commonly used in commercial air conditioners. It uses an unloading mechanism to provide a form of capacity control.
In this video we will cover the digital scroll compressor and its pros and cons. In the next video of this series, we will cover the inverter scroll compressor for comparison.
The aim of these videos is to help HVAC engineers make more informed decisions when choosing air conditioning equipment.
Links to academic studies that plotted the efficiency of the digital scroll compressor:
docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2671&context=icec
docplayer.net/15274978-Development-and-testing-of-a-multi-type-air-conditi...
Просмотров: 16 962

Видео

The Scroll Compressor - Basics & The Fixed Speed Type
Просмотров 32 тыс.3 года назад
Scroll compressors are the most common type of compressor used in commercial air conditioners. But there are sub types of the scroll compressor which can make things a bit confusing. In this video we will cover the basic operating principle of the scroll compressor and the pros and cons of the fixed speed type. In the next two videos we will discuss the digital scroll compressor and the inverte...
Return Air Bypass Mode For ERV & HRV Units - Demand Controlled Ventilation
Просмотров 4,7 тыс.3 года назад
Return Air Bypass is another ERV or HRV unit mode that involves a form of heat exchanger bypass. Its function is quite different to economy cycle mode though, so it is important to understand the difference. In this video we explain Return Air Bypass Mode and how it can further miminise energy consumption by matching ventilation rates with demand.
Economy Cycle Mode for ERV & HRV Units
Просмотров 3 тыс.3 года назад
At Air Change we often get asked how economy cycle mode works with Energy Recovery Ventilators or Heat Recovery Ventilators units. So in this video we will explain it! In our previous video, we covered how ERV & HRV units minimise an outside air load by transferring heat, or energy, between air being exhausted outside and fresh air being supplied inside. Despite saving large amounts of energy s...
ERV & HRV Units Explained
Просмотров 141 тыс.3 года назад
Energy Recovery Ventilators & Heat Recovery Ventilators explained - what they are used for and how they work. Buildings need fresh air for indoor air quality. But introducing fresh air comes with an energy penalty. This is where ERV & HRV units help.
Low Dew Point Refrigeration Systems for Dehumidification
Просмотров 1,6 тыс.4 года назад
Air Change ACDHUM and Precise Control Units can incorporate Low Dew Point DX Refrigeration Systems for dehumidifying air to particularly low moisture contents. In this video we explain how Low Dew Point DX systems work, and how they provide a simple solution for humidity sensitive HVAC projects.
Hybrid CHW & DX Cooling Systems Part 2: Improving Chiller Operating Efficiency
Просмотров 3,1 тыс.4 года назад
Air Change Precise Control Units can incorporate chilled water coils alongside DX refrigeration to form a hybrid cooling system. In this video, Part 2 of Hybrid Chilled Water and DX Cooling Systems, we will cover how hybrid PCUs can save energy by improving the efficiency of chillers, particularly those that are operating in humid climates. If you haven't seen the Part 1 video, make sure you ch...
Combined Pool Water Heating & Air Handling for Large Energy Savings!
Просмотров 4,1 тыс.4 года назад
Indoor pools are great fun. And the provide us with a means of exercise contributing to our health and wellbeing. But to say indoor pools are energy demanding is an understatement. The pool water heating, the indoor air temperature control, and the high ventilation rates all consume large amounts of energy! The Air Change Poolpac has long been regarded as the go to solution for delivering effic...
Hybrid CHW & DX Cooling Systems Part 1
Просмотров 7 тыс.4 года назад
Air Change Precise Control Units can incorporate chilled water coils alongside DX refrigeration systems to form a hybrid cooling system. In this video, part 1 of hybrid cooling systems, we will go over the basic operating principle of hybrid Precise Control Units and how they can help CHW cooling systems perform better in humid climates. Learn more about our PCU ranger here: www.airchange.com.a...
Dehumidification & Humidification Combined
Просмотров 4,5 тыс.4 года назад
Air Change DOAS & Dehumidification units can incorporate humidifiers for complete indoor humidity control. Humidification in HVAC design is likely to grow in importance, as numerous health studies have found that low humidity levels seem to increase the transmission of viruses. Air Change combined humidification units simplify site installation as separate pieces of equipment are not needed for...
The Art of the Chart, Part 1 - A Guide to the Psychrometric Chart
Просмотров 7874 года назад
The Art of the Chart, Part 1 - A Guide to the Psychrometric Chart and how it Makes the Invisible Visible. Dry bulb temperature, wet bulb temperature, relative humidity and humidity ratio are covered in this video. Some HVAC engineers may find the psychrometric chart to be a bit daunting or confusing. Or maybe they have a good understanding of it but see it as a non-essential tool. Well, in this...
Split Make-Up Air (SMA) Explainer Video
Просмотров 1,5 тыс.4 года назад
Air Change SMA units supply dehumidified make-up air in an energy efficient manner. SMA units can also help VRF systems perform better in humid climates. Learn more about our SMA range here: www.airchange.com.au/cms/?product=split-make-up-unit
Precise Control Unit (PCU) Explainer Video
Просмотров 2,8 тыс.4 года назад
Designing effective HVAC systems for humidity control can be challenging. Because of this, Air Change developed the Precise Control Unit range of dehumidifiers to help HVAC engineers implement the simplest and most reliable solution for humidity control. Air Change PCU - precise temperature and humidity control for any application. Learn more about our PCU range here: www.airchange.com.au/cms/?...