Michael Jones
Michael Jones
  • Видео 130
  • Просмотров 75 847
Sailing 2023 Mrs Jones & Ghost SD 480p
This is a slide show of the sailing on Mrs. Jones and Ghost in 2023.
Просмотров: 57

Видео

Sailing 2023 SD 480p
Просмотров 289 месяцев назад
Theyear in sailing first on the Mumm 36 Mrs. Jones and then on the Farr 40 Ghost. So mush fun!
Three phase power
Просмотров 3703 года назад
Three phase power
Capacitance
Просмотров 2613 года назад
Capacitance
Inductance
Просмотров 3553 года назад
Inductance
Alternating Current 1
Просмотров 3443 года назад
Alternating Current 1
AC Power
Просмотров 1523 года назад
AC Power
Distribution System Layout
Просмотров 5213 года назад
Distribution System Layout
Poles, Pole Top Hardware, and co
Просмотров 7743 года назад
Poles, Pole Top Hardware, and co
Pole Top Equipment
Просмотров 4663 года назад
Pole Top Equipment
Delta and Wye Primary Systems
Просмотров 6 тыс.3 года назад
Delta and Wye Primary Systems
Grounding
Просмотров 8963 года назад
Grounding
Equal Potential Grounding
Просмотров 12 тыс.3 года назад
Equal Potential Grounding
Equal Potential Grounding Connec
Просмотров 1,6 тыс.3 года назад
Equal Potential Grounding Connec
Transformer Basics
Просмотров 4,5 тыс.3 года назад
Transformer Basics
Single Phase Transformer
Просмотров 3323 года назад
Single Phase Transformer
Three Phase Primary Connections
Просмотров 7573 года назад
Three Phase Primary Connections
Delta Secondary Connections 1
Просмотров 3743 года назад
Delta Secondary Connections 1
Wye Secondary Connections
Просмотров 1853 года назад
Wye Secondary Connections
Basic Concepts of Power Quality
Просмотров 1873 года назад
Basic Concepts of Power Quality
Power Quality and the Customer
Просмотров 1063 года назад
Power Quality and the Customer
Curouts and reclosers intro
Просмотров 3513 года назад
Curouts and reclosers intro
Cutoffs
Просмотров 1063 года назад
Cutoffs
Reclosers
Просмотров 6573 года назад
Reclosers
Pole Top Voltage Regulators
Просмотров 4,8 тыс.3 года назад
Pole Top Voltage Regulators
Trouble Shooting a Voltage Reg
Просмотров 1463 года назад
Trouble Shooting a Voltage Reg
Replacing a Voltage Reg
Просмотров 1303 года назад
Replacing a Voltage Reg
Valparaiso
Просмотров 253 года назад
Valparaiso
maintianing motors 6
Просмотров 2353 года назад
maintianing motors 6
Maintaining Motors 5
Просмотров 2953 года назад
Maintaining Motors 5

Комментарии

  • @haitianstudent
    @haitianstudent День назад

    If you create an equal potential zone one span down, can you just put the bracket at the pole you’re climbing and connect it to the neutral, to climb over and work on the primary, without any additional grounds.?

  • @kelvinitotia4807
    @kelvinitotia4807 20 дней назад

    Thank you for this information!🎉

  • @kelvinitotia4807
    @kelvinitotia4807 20 дней назад

    Thank you 🎉

  • @armandoniebla
    @armandoniebla Месяц назад

    Armando nieblapasswordpasswordpasswordpasswordpasswordpasswordpasswordpasswordpasswordpasswordpassword

  • @TempleHerbert-f4j
    @TempleHerbert-f4j 2 месяца назад

    Alisa Fort

  • @armandoniebla
    @armandoniebla 2 месяца назад

    Armando niwvlapassqordpassqordpassqordpassqordpassqordpassqordpassqordpassqordpassqordpassqordpassqordpassqord

  • @JustNoah7
    @JustNoah7 2 месяца назад

    Thanks

  • @dangerchicken6943
    @dangerchicken6943 2 месяца назад

    You lost me 5 seconds in. Nipsco is a trash company. Scumbags all around. Chairmen to linemen. All slime

  • @ThomasPerez-l1p
    @ThomasPerez-l1p 3 месяца назад

    White Michael Taylor George Jackson Linda

  • @GloriaOwens-i3n
    @GloriaOwens-i3n 3 месяца назад

    Martinez Richard Allen Matthew Taylor Shirley

  • @JimwombatLand
    @JimwombatLand 4 месяца назад

    handline must be placed property, lineman must use it correctly,

  • @JimwombatLand
    @JimwombatLand 5 месяцев назад

    added advantage of capacitors is a voltage boost ...one or two volts most of the time ...depends where and how they are positioned on the line.

  • @monampuan2083
    @monampuan2083 5 месяцев назад

    Where to use delta delta connection?

  • @ibinsetradutasetra5327
    @ibinsetradutasetra5327 6 месяцев назад

    Thank you.

  • @backwoodz7160
    @backwoodz7160 7 месяцев назад

    Are u expected to handline transformers? Or do they use equipment for that

    • @brother_marzooq9097
      @brother_marzooq9097 6 месяцев назад

      No. There is a transformer jib that is sent up to you from a handline. You then attach that to the pole and then are sent up a rope pulley that allows the Groundsman to raise the transformer up to the position of where you are attaching it.

  • @markhemmings397
    @markhemmings397 7 месяцев назад

    Great video, something easier to understand about older educational videos!! Cheers

  • @bryanflores9056
    @bryanflores9056 9 месяцев назад

    These are the segments I’m learning in line school today

  • @linehandibew6205
    @linehandibew6205 9 месяцев назад

    So glad they copied cynch lock and change the design. The first style was trash

  • @ncooty
    @ncooty 10 месяцев назад

    Interesting, but not the least bit useful, because it doesn't really explain the principles or rationale. It's more about norms (with several exceptions), as if high-voltage electrical systems are like ornithology.

  • @lewy1
    @lewy1 11 месяцев назад

    Why is he wearing sleeves?

  • @linehandibew6205
    @linehandibew6205 Год назад

    Use a load buster on all capacitor banks , fixed and switched. Being that an oil switch is not a visual open. Never trust and switch without a visual open. On a switched bank operate unit to open verify open on switch i indicators then use load buster to open cutouts. Wait 5 minutes then bleed off any stored voltage with a ground.

  • @linehandibew6205
    @linehandibew6205 Год назад

    Bonus climbing with a perfectly good bucket right there 😂😂

  • @linehandibew6205
    @linehandibew6205 Год назад

    You can use two bushing delta pots on a wye system. It all depends on the transformers required system voltage. Our system is 7620/13.2Y and we have transformers that require 13.2 so they get 2 primary connections. And we have single phase 7629 pots that are conventional 2 bushing pots . It all depends on the system voltage and the required voltage of that transformer. I’ve worked on systems that were grounded wye on the main line and all the fused laterals were 2 phase delta with no neutral. Key thing is pay attention to system voltage and required voltages of the equipment being installed.

  • @linehandibew6205
    @linehandibew6205 Год назад

    We also use a neutral tester. Don’t trust the dials on the controller. With line side energized and load side port we test across line side and load side and cycle the unit through its steps and verify proper operation. Then we verify 0. After verification of tester working and that the unit operates properly then we tie in load side.

  • @georgeshelton6281
    @georgeshelton6281 Год назад

    Dudley Do-Right was hallucinating no thanks to what Snidley Whiplash did.

  • @ibraahimfiqi5115
    @ibraahimfiqi5115 Год назад

    how to figure out the timing for each section and the fault current?

  • @14IEA
    @14IEA Год назад

    Excellent video, do you have more videos regarding voltage regulators?

  • @tedlahm5740
    @tedlahm5740 Год назад

    Suggestion: On the triangular DELTA drawing. We could label the WINDING ends as H1 and H2 . This would help the NEW LEARNER visualize the concept. thank you

  • @tedlahm5740
    @tedlahm5740 Год назад

    Question: On the wye primary single bushing 3 phase configuration. What would happen if the GROUND connection to the EARTH became disconnected? I see no parallel neutral back to the substation? PS. wonderful presentation.

  • @tedlahm5740
    @tedlahm5740 Год назад

    Can the DISTRIBUTION system have a three phase three wire DELTA system WITH NO Neutral (back to the substation) and use a single BUSHING transformer with a CASE GROUNG ? This possibly not covered in the video? thank you

  • @tedlahm5740
    @tedlahm5740 Год назад

    Forward slash. not back slash on the voltages.

  • @tedlahm5740
    @tedlahm5740 Год назад

    Clearly the secondary two ends (left and right) are wound in opposite direction. This would not be good.m😊

  • @georgegrigolava4370
    @georgegrigolava4370 Год назад

    I love old school presentations like this. Do you know where I can find the other segments to watch?

    • @tonydelpilar
      @tonydelpilar Год назад

      Yes, where we can find the other segments?!

  • @donknots7003
    @donknots7003 Год назад

    This rocks

  • @mthobisiquinton226
    @mthobisiquinton226 Год назад

    Woe thank you

  • @brandanhall1138
    @brandanhall1138 Год назад

    How does the current flow through a wood to get to ground. I thought wood is a insulator

    • @mikemazzantini6397
      @mikemazzantini6397 Год назад

      The neutral wire is grounded somewhere.

    • @tedlahm5740
      @tedlahm5740 Год назад

      given enough voltage (pressure) it will conduct?

    • @gmccambry5963
      @gmccambry5963 Год назад

      @@tedlahm5740 Yes, that is reason they manufacture different class of ppe. At certain potential an insulator could become conductor.

    • @lewy1
      @lewy1 Год назад

      We were setting a pole under a 500kv line and we had to wear rubber gloves to handle the pole and the pole was never close to touching the line.

  • @lausd3138
    @lausd3138 Год назад

    Great teaching!!!

  • @benh580
    @benh580 Год назад

    When I went to pole climbing school we freeclimbed up and then belted. Cool video

  • @demiszenebe9133
    @demiszenebe9133 Год назад

    Great Really great!!!

  • @francisalbert1971
    @francisalbert1971 2 года назад

    Thank You very much!! I´ll use this to my team!!!

  • @rizwanahmed7382
    @rizwanahmed7382 2 года назад

    Very Good Explanation

  • @nestoralban8863
    @nestoralban8863 2 года назад

    Gracias por su videos salvan vidas

  • @joelgobeh7343
    @joelgobeh7343 3 года назад

    Wonderfully explained

  • @windspeedmetersandanemomet6444
    @windspeedmetersandanemomet6444 3 года назад

    THANK YOU, INFORMATIVE. 👍👍

  • @windspeedmetersandanemomet6444
    @windspeedmetersandanemomet6444 3 года назад

    THANKS FOR THE VIDEO!!

  • @phil6419
    @phil6419 5 лет назад

    I have hull number 12. This video makes me want to yank the pedestal steering and put in a tiller. The rudder shaft is already through the deck and ready to go.

  • @interstatesailing9484
    @interstatesailing9484 11 лет назад

    I love it!