TOSHIBA VF-AS1 Factory reset (Drive/Inverter reset to default factory settings)
Просмотров 9459 месяцев назад
Video shows how to restore inverter to factory reset.
SEW Eurodrive LTE B+ Factory reset (Drive/Inverter reset to default factory settings)
Просмотров 72711 месяцев назад
SEW Eurodrive LTE-B inverter factory reset with explanation.
PDL Microflo Microdrive Factory reset (Drive/Inverter reset to default factory settings)
Просмотров 72611 месяцев назад
PDL MicroFlo inverter factory reset with explanation. The same procedure should wotk with MICRODRIVE series.
TOSHIBA VF-S7 Factory reset (Drive/Inverter reset to default factory settings)
Просмотров 2,2 тыс.11 месяцев назад
Video shows how to restore inverter to factory reset.
NORD SK PAR-3H ParameterBox Hanheld unit - Connection to NORDCON software
Просмотров 618Год назад
Video with a hint, if your NORDCON software can not find your SK PAR-3H handheld unit.
TR Electronic - PT100n encoder programmer - Simple overview - no explanation
Просмотров 212Год назад
TR Electronic - PT100n encoder programmer - Simple overview - no explanation
NORD SK PAR-3H ParameterBox Hanheld USB/PC programmer - Disassembled unit overview
Просмотров 103Год назад
NORD SK PAR-3H ParameterBox Hanheld USB/PC programmer - Disassembled unit overview
HOLIP HLP-A / HLP-B / HLP-SJ Factory reset (Drive/Inverter reset to default factory settings)
Просмотров 3 тыс.Год назад
HOLIP HLP-A / HLP-B / HLP-SJ Factory reset (Drive/Inverter reset to default factory settings)
Schneider ATS22 - ALTISTART Transistor testing (Soft starter unit_
Просмотров 472Год назад
Schneider ATS22 - ALTISTART Transistor testing (Soft starter unit_
Schneider ATS22 - ALTISTART inverter Factory reset (Drive/Inverter reset to default settings)
Просмотров 2 тыс.Год назад
Factory reset of an Schneider ATS22 softstarter
Schneider Telemecanique ATV18 Altivar - Factory reset (Drive/Inverter reset to default settings)
Просмотров 2,5 тыс.Год назад
Schneider Telemecanique ATV18 Altivar - Factory reset (Drive/Inverter reset to default settings)
INFRATEC pyrometer MEP series - MEPCTLT15CB3 (thermoMETER CTL Micro Epsilon)
Просмотров 188Год назад
Simple testing of Infratec infrared pyrometer. No explanation.
EATON MMX (M Max Micro) inverter Factory reset (Drive/Inverter reset to default factory settings)
Просмотров 2,2 тыс.Год назад
Quick video on how to Factory Reset EATON MMX drive
Schneider Electric XPS-DMB1132 - 2 coded magnetic switch Safety relay Preventa Safety XPSDMB
Просмотров 2,9 тыс.Год назад
Simple testing of old stock item, before sale.
LS electric iG5A Factory reset (Drive/Inverter reset to default factory settings)
Просмотров 6 тыс.Год назад
LS electric iG5A Factory reset (Drive/Inverter reset to default factory settings)
Moeller DV51 (Drive/Inverter reset to default factory settings)
Просмотров 3 тыс.Год назад
Moeller DV51 (Drive/Inverter reset to default factory settings)
EATON DC1 - Default password - Extended menu access = Parameter P-14
Просмотров 752Год назад
EATON DC1 - Default password - Extended menu access = Parameter P-14
EATON DC1 series frequency inverter DC1-34024FB-A20CE1 (380VAc / 11kW) Basic function test
Просмотров 967Год назад
EATON DC1 series frequency inverter DC1-34024FB-A20CE1 (380VAc / 11kW) Basic function test
Terminal connection - Danfoss MCD3000 (MSD series) - control pinout QUICK OVERVIEW
Просмотров 480Год назад
Terminal connection - Danfoss MCD3000 (MSD series) - control pinout QUICK OVERVIEW
Terminal connection - Danfoss MCD500 (MSD series) - control pinout QUICK OVERVIEW
Просмотров 608Год назад
Terminal connection - Danfoss MCD500 (MSD series) - control pinout QUICK OVERVIEW
REPAIR - Danfoss MSD1030 - Power transformer replacement (10V, 12V, 12-0-12V) (MSD series)
Просмотров 95Год назад
REPAIR - Danfoss MSD1030 - Power transformer replacement (10V, 12V, 12-0-12V) (MSD series)
Terminal connection - Danfoss MDS1030 (MSD series) - control pinout QUICK OVERVIEW
Просмотров 51Год назад
Terminal connection - Danfoss MDS1030 (MSD series) - control pinout QUICK OVERVIEW
LENZE Vector 82BRH.V (82B RH.V) High Voltage Thick film Ceramic Resistor
Просмотров 302Год назад
LENZE Vector 82BRH.V (82B RH.V) High Voltage Thick film Ceramic Resistor
Part 1 - OMRON H8PR - Rotary CAM positioner - Overview / disassembly (H8PS)
Просмотров 329Год назад
Part 1 - OMRON H8PR - Rotary CAM positioner - Overview / disassembly (H8PS)
KEB Combivert G6 / F6 series - X4A Diagnostics / Access / Programming port pinout / Combivis
Просмотров 642Год назад
KEB Combivert G6 / F6 series - X4A Diagnostics / Access / Programming port pinout / Combivis
KEB Combivert G6 / F6 series - Default password / Application Access Level overview
Просмотров 670Год назад
KEB Combivert G6 / F6 series - Default password / Application Access Level overview
KEB Combivert F5 - PROFINET operator simple overview (00.F5.060.L100) Diagnose
Просмотров 341Год назад
KEB Combivert F5 - PROFINET operator simple overview (00.F5.060.L100) Diagnose
KEB Combivert F5 - CAN-OPEN operator simple overview (00.F5.060.5100) CanBus
Просмотров 338Год назад
KEB Combivert F5 - CAN-OPEN operator simple overview (00.F5.060.5100) CanBus
Thalheimer ESS 104 - Adjustable Transformer overview / testing (Autotransformer)
Просмотров 259Год назад
Thalheimer ESS 104 - Adjustable Transformer overview / testing (Autotransformer)

Комментарии

  • @instabeatzbhremix7938
    @instabeatzbhremix7938 13 дней назад

    IG5A-4 value increase decrease up down button doesn't work please help

  • @mosik2
    @mosik2 26 дней назад

    Hello there thanks for your information i have vacon nxl wana run a fan with that and with key pad control set controller with keypad in parameters but motor don't run and start dont show on panel pls help me

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 26 дней назад

      If inverter runs from terminals, but does not run via Local control (operator panel) than issue is with parameters.

  • @primehunterradiantvisions
    @primehunterradiantvisions Месяц назад

    Why my IG5A has HP parameters and SENH error? Can you help me

  • @atpk5142
    @atpk5142 Месяц назад

    why i am using auto mode then after a while it switches to manual mode without anyone touching it

  • @atpk5142
    @atpk5142 Месяц назад

    why i am using auto mode then after a while it switches to manual mode without anyone touching it

  • @siddhakalipritingpress4834
    @siddhakalipritingpress4834 2 месяца назад

    Then what to do next???

  • @tum_86
    @tum_86 2 месяца назад

    มันใช้กับรุ่น m701ได้ไหม

  • @dentech6865
    @dentech6865 2 месяца назад

    Nice... Basic😉

  • @gt4654
    @gt4654 2 месяца назад

    Be careful. This chip is NOT RS-232, but RS-485. In specsheet, it may be used for both, but these KEB machines configures the MAX chip as RS-485 and the cables are NOT compatible with RS-232. You may burn either device or host, or both if you use normal RS-232 cable. Don't ask me how I know ;)

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 2 месяца назад

      Hi. Interesting INGO. Some time ago i disassembled one of the KEB F5 keypads with HSP5 port to see what it looks like inside and i seem to recall it had a CANbus lines to that port. Did not continue checking other pins. Sadly i didn't managed to test the Chinese cable - destroyed before testing. Thanks for input

  • @RameshChand-ym1br
    @RameshChand-ym1br 2 месяца назад

    How to repair power supply

  • @theinel
    @theinel 3 месяца назад

    Hi, Can I use cheap chinese USB to can adapter?

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 3 месяца назад

      In my experiance, you can use a cheap end USB-RS485 adapters. I myself for service purpose have a Lecom AB adapter with RS485 and RS232. And i am usually using cheap RS232 adapter. Works fine.

    • @theinel
      @theinel 3 месяца назад

      @@oem-xenon-repair7896 Sorry, but what I mean is can we use cheap CAN BUS to RS232 adapter?

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 3 месяца назад

      @@theinel now you're confusing me. Video you commented on, shows Lecom LENZE programming adapters (RS485 / RS232). I can only assume that you have a system where LENZE drive is controlled via CAN (you're system has only LECOM CAN adapter) , and you want to connect to it via cheap CAN-USB adapter. This is something I actually wanted to try myself, but don't have a Lenze drive with LECOM CAN adapter to test this idea.

    • @theinel
      @theinel 3 месяца назад

      @@oem-xenon-repair7896 Lenze lecom adapter is quite expensive, if we can replace it with cheaper CAN adapter maybe will be good..Thats the idea.

    • @felipefranco8977
      @felipefranco8977 2 месяца назад

      ​@@theinelconseguiu resposta em relação a está adaptação? Vi que um original CAN LECOM está mais de 500 dólares

  • @samuelmartinez-c2n
    @samuelmartinez-c2n 3 месяца назад

    Good morning, very good content, my question is if you know the parameter to modify the torque

  • @machineryoverhaulretrofitm6607
    @machineryoverhaulretrofitm6607 3 месяца назад

    THANKS

  • @perokokpasif
    @perokokpasif 4 месяца назад

    Do you have hlp a series pdf ? Cuz i need

  • @erye9978
    @erye9978 5 месяцев назад

    maybe you can draw the schematic diagram, so you can fix it and that could be very helpful for us 🤭

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 5 месяцев назад

      Honestly I don't even know that this cable actually works through RJ45 port on the operator panel. Should have tested before disassembly. As i have original KEB USB adapter - I probably won't be spending any time on this Chinese cable.

  • @raheelkhan3815
    @raheelkhan3815 5 месяцев назад

    Please tell me which parameters of the delegation have to be set to operate from the switch and what are the parameter settings of the potentiometer.

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 5 месяцев назад

      I dont quite understand what you mean? It works with default settings. Do a factory reset, and it will work from buttons/switches connected toerminals.

    • @raheelkhan3815
      @raheelkhan3815 5 месяцев назад

      @@oem-xenon-repair7896 please tell me default settings parameter

  • @GoodElectronic
    @GoodElectronic 5 месяцев назад

    Thank you! Works the same for Commander SE.

  • @pregadordigital2952
    @pregadordigital2952 5 месяцев назад

    Preciso fazer esse comando...quais parâmetros tem que alterar

  • @shashikantmishra5238
    @shashikantmishra5238 5 месяцев назад

    Programming list

  • @sudhakart5354
    @sudhakart5354 6 месяцев назад

    How to set a parameter s

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 5 месяцев назад

      Which parameters? Even when using RUclips comment to ask someone for help its usefull to be specific!

  • @OscarSanchez-hs3jv
    @OscarSanchez-hs3jv 6 месяцев назад

    Donde lo puedo comprar

  • @RichardBonne-xb3zu
    @RichardBonne-xb3zu 7 месяцев назад

    Merci infiniment pour cette video (qui ma permis de delocker 2 unités récupérées )

  • @tranxuantoan1000
    @tranxuantoan1000 7 месяцев назад

    hi sir, how about the Undrive Sp? how we can remove the passcode, thank you alot

  • @hoangtieu5076
    @hoangtieu5076 7 месяцев назад

    hi sir , please give me diagram rj45

  • @danishbutt503b
    @danishbutt503b 7 месяцев назад

    its not perform Err Occured When Im Try This Kindly Help Me plzz❤

  • @GLLOBAL.51979
    @GLLOBAL.51979 7 месяцев назад

    Hello sir,, how can i reset my vfd like that,, my vfd is indicated the NET i can't change it, i hope you got this. Thanks

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 7 месяцев назад

      Did you check the manual before going to YT comment section?

  • @lnskid07haha96
    @lnskid07haha96 8 месяцев назад

    The GOAT

  • @ammarmouldi3816
    @ammarmouldi3816 8 месяцев назад

    Salut

  • @rajathiban8050
    @rajathiban8050 8 месяцев назад

    Which terminal used for reverse direction

  • @froogybaby
    @froogybaby 8 месяцев назад

    does the 3 wire input has a polatiry or signs?

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 8 месяцев назад

      What do you mean by polarity? Default connection is PNP (positive logic (24Vdc)).

  • @elielsilvaurra7689
    @elielsilvaurra7689 8 месяцев назад

    when I turn-on the inverter and I try to change to the PU mode (by pressing it, since it's default setting it seems to be in EXT) it doesn't work :(. Actually it doesn't do anything no matter if I press it multiple times or keep it pressed (dor a couple seconds), etc., could you help me with that? thx in advance

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 8 месяцев назад

      If settings does not matter, than reset device to factory settings. I'm 99% sure that will delete all other settings that are blocking the LOCAL mode.

  • @NaveedKhan-ro1zs
    @NaveedKhan-ro1zs 8 месяцев назад

    Brother give me keb f4 ( keypad model ) keypad back side picture

  • @irfankeisya5968
    @irfankeisya5968 8 месяцев назад

    How do you get out of the password menu?

  • @Kitty_minnie12
    @Kitty_minnie12 9 месяцев назад

    जोक स्पीड का हिंदी में बताए

  • @korayarslan1082
    @korayarslan1082 10 месяцев назад

    hello, could you share keb f4 parameter?

  • @mdayubali7814
    @mdayubali7814 10 месяцев назад

    আসসালামু আলাইকুম ভাই,Mitsubishi Inverter Fr E540. সমস্যা হল ইনভাটার On হয় না। সুইচ বোর্ড থেকে চালু দিলে অন্যান্য ইনভাটার চলে কিন্তু এই ইনভার্টার টা অন হয় না দয়া করে একটু পরামর্শ দিলে উপকৃত হব। ধন্যবাদ ভাই ভালো থাকেন।

  • @Jahangir-pt9lu
    @Jahangir-pt9lu 10 месяцев назад

    Hello

  • @ricardogallegosnina6777
    @ricardogallegosnina6777 10 месяцев назад

    Thank you very much

  • @sdengineers1742
    @sdengineers1742 11 месяцев назад

    I want to Control Card Rating Change. Plz Tell me how to D740 Control Card Rating change

    • @ainisl.3557
      @ainisl.3557 11 месяцев назад

      Why would somebody go on RUclips and ask silly questions like these in video comment section while using his company's logo in his account (or company's RUclips account)? In your company's homepage, it is clealry stated (quote from homepage): "SD ENGINEERS is BHILWARA (Rajasthan) based company. We provide high quality systematic repairing job work in the field of industrial electronics instrumentation and Ac Drives Sales And Services." 😂 "RUclips" engineer! 😂

  • @NiroPraneeth
    @NiroPraneeth 11 месяцев назад

    This one reset after all program setting Eres

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 11 месяцев назад

      Is that a question? Or statement? Method, seen in video, will restore all settings to factory defaults (delete all settings).

  • @mdayubali7814
    @mdayubali7814 11 месяцев назад

    আসসালামু আলাইকুম ভাই, আমি সিপনিং মিলের প্যারামিটার কিভাবেই সেটিং করতে হয় দয়া করে জানাবেন । ধন্যবাদ ।

  • @sluzorkiestra6020
    @sluzorkiestra6020 11 месяцев назад

    Could u tell me , which numbers of terminal block are u use to potentiometer ?

  • @hugoventer739
    @hugoventer739 11 месяцев назад

    Hi there I see you have a yellow wire connected on PC where dose it connect to ? from where?

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 11 месяцев назад

      Depending what control type you use (NPN or PNP). I probably used: SD to FWD / SD to RVS

  • @hungphong8h163
    @hungphong8h163 Год назад

    Can you explain that my vacon p2.1.11 is 0.00hz? Thank you

  • @maatarashankhabhandar2784
    @maatarashankhabhandar2784 Год назад

    XPS -ac need connection details, can you please help?

  • @FreeButOnline
    @FreeButOnline Год назад

    dear sir will you please help me about. commander SK which is showing a fault HF 20

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 Год назад

      If you have read the user manual, you'll see it's HF=Hardware fault. 20 = power stage error. . Probably defective power module. Replace the drive or bring to repair service. Do not attempt to do it yourself - way too many components are probably burnt.

    • @ThorOdinson1269
      @ThorOdinson1269 5 месяцев назад

      ​@@oem-xenon-repair7896 Sir, I've got HF26 fault code displayed, it's not giving me any output. Is the unit too defective to fix?

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 5 месяцев назад

      @@ThorOdinson1269 that's another HF (hardware fault). 26- either soft start relay defective or IGBT short circuit. There's no Quick Fix for Hardware Faults. If its relays fault a replacement could maybe fix it. However you're dealing with relative high DC voltage. Without any previous repair skillset i would not advise to attempt any kind of repair.

  • @Fduch-a
    @Fduch-a Год назад

    trash

  • @domingoshondehonde6339
    @domingoshondehonde6339 Год назад

    helo,, I like so much it. can you give me de electric diagram, and i have drive vacon 20, i want to conect but i dont have electric diagram..

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 Год назад

      Did you try to google first? Theres a lot of manuals available in Vacon homepage.

  • @DudasDudek
    @DudasDudek Год назад

    How to set moving back?

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 Год назад

      Again -> depends on your settings. If inverter is restored to factory settings, then forward and reverse is by default on digital inputs. If your Inverter is already preprogrammed and inputs already used for different functions, then I can't helt you any further.

  • @michaelcostello6991
    @michaelcostello6991 Год назад

    Does the speed you enter manually change after you go back to auto ?

    • @oem-xenon-repair7896
      @oem-xenon-repair7896 Год назад

      Depends on your settings. In terminal control mode - speed is set by analog input. In Manual control mode (control from operators panel) - speed is entered via potentiometer.