- Видео 9
- Просмотров 41 298
Golden4o
Добавлен 17 июл 2016
Streaming PC Games and everything about PC and PC Games! :)
Honda Club Bulgaria - Meeting 2024
Honda Club Bulgaria - Meeting 2024
Music - ruclips.net/video/JHwSP3juBvw/видео.html
Music - ruclips.net/video/JHwSP3juBvw/видео.html
Просмотров: 431
Видео
Growatt 3x SPF5000ES Parallel with batteries (Settings)
Просмотров 3,6 тыс.10 месяцев назад
In the video we are going through my 3x Growatt inverter settings. The system is with 3x Growatt SPF5000ES inverters working in parallel in a single phase with 7 batteries. #SPF5000ES #growattsettings #diysolar
Growatt SPF 5000 ES Parallel Installation with batteries
Просмотров 11 тыс.Год назад
In this video we will see how to connect 3 x Growatt SPF 5000 ES inverters to work in parallel in single phase with 7 batteries. Please note that some of the batteries might need a different communication setup between them. Also, please check your batteries manual before set them up. In the next video we will go through the Inverters settings and see how we can customize them.
Growatt Thor EV Charger Installation
Просмотров 3,9 тыс.2 года назад
Installing Growatt Thor EV Charger at home. I am still trying to figure out how to use the clamp meter... I will upload a new video just for that.
Growatt Thor 7KW Unboxing
Просмотров 1,5 тыс.2 года назад
This is the Growatt Thor 07AS-P 7KW (Single Phase Home EV charger)
Growatt SPF 5000 ES with battery BMS
Просмотров 19 тыс.2 года назад
Growatt SPF 5000 ES working in parallel in single phase and communication with 4x 48v 200Ah batteries BMS
GTX 1080 Ti Poseidon Install
Просмотров 1,7 тыс.7 лет назад
The end to end process of upgrading Snow White with GTX 1080Ti Poseidon Platinum Don't forget to subscribe for more. You can find me in: Twitch - www.twitch.tv/golden4o Twitter - Golden4o Facebook - Golden4o Music Is provided by - Hero Radio Support Hero Radio: RUclips: hero.re/1XZw0Rf Twitter: hero.re/1NoFLYu Facebook: hero.re/1NoFNj6 Support Elias Erlandsson: Soundclo...
Peel of the plastic from Asus GTX 1080 Ti Poseidon
Просмотров 2217 лет назад
I will make a video of how i build the PC.. You can find me in twitch too - www.twitch.tv/golden4o
How to clear error 52
Try setting 19,20 to 52V
Do you apply these settings on all 3 inverters? Or only on the Master?
@@qtin88 some of the settings are updated on all via the parallel cables. Just in case check all of the settings on each inverter.
Thanks for the quick response. I did a test yesterday afternoon with a friend’s system and it does update the slaves. Thanks for confirming also.
Thanks. Please can program 50 be set independently on the inverters in a parallel setup? I wish to set the "AC output time" for the slaves different from that of the master. Likewise, can program 4 (power saving mode) be set independently? I hope you understood what I meant.
Hi Am having issues with my growatt battery it starts to change and after ten minutes it shows red and switch off
@@morlaigconteh130 Can you please provide more information? What inverter do you use, what is the battery, do you see any warning or error?
Chiedo aiuto: Non funziona il bilanciamento dei carichi della mia Thor_07ASP Imposto la modalità Fast. Nelle Impostazioni: Impostazione della stazione EV: corrente uscita massima dal palo elettrico (a): 18 (che equivale a 4kw circa). Bilanciamento del carico: abilito e imposto un nuovo periodo (ogni giorno, tutto il giorno), massima potenza importata dalla rete: 4,5kw (ho il contatore da 5kw). Però, se inizio la carica a 4kw (a cui si aggiungono consumi istantanei di casa di circa 0,5kw) e dopo accendo il forno, la pinza amperometrica della colonnina segna 6kw (l'ho lasciato per 2 minuti e poi ho spento). Come mai???😭 (versione firmware THOR_07AS-V4.2.13-20230714)
Chiedo aiuto: Non funziona il bilanciamento dei carichi della mia Thor_07ASP Imposto la modalità Fast. Nelle Impostazioni: Impostazione della stazione EV: corrente uscita massima dal palo elettrico (a): 18 (che equivale a 4kw circa). Bilanciamento del carico: abilito e imposto un nuovo periodo (ogni giorno, tutto il giorno), massima potenza importata dalla rete: 4,5kw (ho il contatore da 5kw). Però, se inizio la carica a 4kw (a cui si aggiungono consumi istantanei di casa di circa 0,5kw) e dopo accendo il forno, la pinza amperometrica della colonnina segna 6kw (l'ho lasciato per 2 minuti e poi ho spento). Come mai???😭 (versione firmware THOR_07AS-V4.2.13-20230714)
Thank you very much. I have two Growatt ES 6000 plus, I want to put them in parallel now I wonder if I can connect the BMS to which Growatt?. Thank you in advance
Thank you very much. I have two Growatt ES 6000 plus, I want to put them in parallel now I wonder if I can connect the BMS to which Growatt?. Thank you in advance
@@Mboliaka It doesn't matter. If the inverters are in parallel you can connect the BMS to either of them.
@@golden4o Thank you
Hello Sir, when we put 3 Growatt in parallel. In which Growatt should we put the BMS as long as we do not have a Hub
Thank you very much. I have two Growatt ES 6000 plus, I want to put them in parallel now I wonder if I can connect the BMS to which Growatt?. Thank you in advance
Hello Sir, when we put 3 Growatt in parallel. In which Growatt should we put the BMS as long as we do not have a Hub
Check the communication ports of each inverter. If you have the new version the ports will be BMS and RS485. In that case you connect the batterie to the Master inverter (Probably it doesn't matter in which one you connect them but I prefer the Master one). If the ports are CAN and RS485 you will need a Hub. (Or you can make your own cable.)
Required a 5 kw 3 phase solar inverter send me contact details
Hi, I have a question... I have a 3-phase 240 V system in my home and two Growatt SPF 6000+ inverters. Can I use those on the 2 phases of my system leaving the 3rd phase intact? I have seen diagrams for seting up and connecting 3 inverters (one on each phase) but no only 2. Would that cause any problems? Thank you!
@@LDGRADBENISTVO I think you can do that. Try setting them up like a 3 phase system (without the 3rd phase). If this doesn't work, you can install the inverters as they are in separate systems with only one phase. (Two single phase systems) And the third phase you leave it as it is now. I'm m not 100% sure if this will work. Pretty sure it will, but still, you have to test it...
@@golden4o thank you!
Тоя белия прелюд ми 'ареса най-много!
Can you limit the %charging (ex. limit to 80%) from the growatt app?
No, the limit has to be set on the car.
hello, I have an identical installation with 3 inverters 5 kW mounted in parallel with a total single-phase output of 45 kw but I have a three-phase public network subscription of 15A per phase, I would like to know if it is possible to make the network injection of the 3 phases with one phase per inverter
Yes, you can make the inverters work in 3 phases and connect each phase of the residential network to the inverters. You can check the manual on how exactly you can connect them. I'm planning to switch to 3 phases as well as I have 3 phases coming to my house. Before you do that please make sure to balance each phase in your house. Because with 3 inverters you will have 5KW on each phase. (Total 15KW on the 3 phases)
@@golden4o Thank you for your feedback but I want to stay in parallel mono and inject each phase in an inverter thank you
@@angelkm2599 If you want to stay on single phase with the inverters and inject, you can only do that with one of the 3 phases that are coming to your house. Just grab one of the phases and connect it to the input of each inverter.
@@golden4o there is a risk of connecting the 3 phases if why, because each inverter normally sends its current, so I do not understand the risk and thank you again for your return
@@angelkm2599 The inverters cannot convert 3 phases into a single phase. No inverter can do that (as far as I know). So in order to use 3 phases, your inverters must be in 3 phase mode. If they are in single phase mode, you can only input single phase.
Please can I parrelle SPH 10000 growatts?
I'm not sure. You should check the manual for your exact model.
C'est génial et bon boulot ❤ mais 6 convertisseur en parallèle comment faire cet programmation.
Setting 23? When you are using single phase with 3 inverters in parallel the manual says to set it to PAL instead of SIG. But then it gives me a fault. What is your opinion? I am using exactly the same combination as your system...
I cannot access Setting 23, from 21 it jumps to 28. My guess is that the communication between the inverters is not properly connected.
Добра работа!
Hello, super video ! You have 4 ROSEN SOLAR batteries and what are the 3 others? Thanks. Jerome.
The other 3 are made from a local company.
@@golden4o can you bank different Ah battery in the same bank? or how are you doing it?
@@valentinvsk4621 What do you mean with bank? You can connect different Ah packs (batteries) in one system. But you cannot connect different Ah cells in one pack (battery). I have 4 batteries that are 200Ah and 3 that are 230Ah
@@golden4o so I have an 85Ah battery and a 200Ah battery,both are from the same brand, but the seller said I cannot parrallel them because of the different capacities.I would like to use both on them on my system.Would it be possible? Thanks
@@valentinvsk4621 Technically you can parrallel them, but one of the batteries will be depleted long before the other and if you have a big load the BMS of the other might shut off the power. That is why it is not recommended to parrallel them.
Where can i get those busbars ?
I was able to purchase the last two in stock from Amazon UK.
Link ?
Gloaso 600 Amp Bus Bar 300V AC /... www.amazon.co.uk/dp/B0B2JQR4VP?ref=ppx_pop_mob_ap_share
Sir what is the Max. PV input current of this inverter ?
18 Amps
Браво! Много полезно видео!
Very useful and well done. Thank you
Thanks for your efforts. You are doing a good job explaining things, especially considering English is not your native language. You are easy to understand. Greetings from Australia. I have 2 of those inverters, still in their boxes. The cost of batteries is the real killer!
Hi, can you tell me how to set up BMS protocol with lifepo4 baterry?
I will try to make another video for that.
Nice video, well done and beautifully explained about the good practices and also the bad ones. Keep the work going on for your off grid setup, by the way how much battery capacity are you using?
Thank you. My batteries are about 70KWh (7x200-230ah)
I need ur complete video of the installation of the 3 grow watt inverter
Next week I will be reinstalling them. I will try to make more informative video.
Би ли пуснал една снимка на буксата с 3-те кабелчета и в кой порт я вкарваш на инвертора. BMS или RS-485
Are you happy with the charger? Is it any good?
Yes. The charger is great. The only downside is for Teslas. There is no unlock button on the handle and I have to unlock the port from my phone or the car.
Alright thanks! I've ordered mine yesterday so wish me luck :D
Інформації нуль... Щось якось і через щось Клятий інвертор не хоче з батареєю працювати... Хоч би десь знайти інформацію про режими пункта 36...
Show how you connect it to the battery! All I learned is cut your cable into and hook it to the inverter and battery.
I am pretty sure you only connect to master of course is good to connect the 3 just because you. Don’t need to worry about startup order
Good morning, Sir, I am contacting you because I am really lost in the commissioning of a Growatt Thor 22 as-p... I am an engineer in Belgium and I have a small renewable energy company! I have no answer from the Growatt technical department. I have already spent hours on ShinePhone and ShineTools but I cannot add and make the commissioning of this E-V Charger! LinkdIn is my last hope to contact Growatt and try to get help... I hope you can help me or direct me to someone who can help me. In advance I would like to thank you. Sincerely yours.
Can you show cable pin out?
Great info. I just need to know whats the pin order 4th pin CAN H , 5th pin CAN L 6th pin Ground in the Growatt 5000es side. Is ground pin matters? My battery ground pins are PIN 2, PIN 7 CAN L and CAN H are correctly aligned
Can you explain how you connected 3 inverters to 4 batteries? Someone told me: Growatt SPF 5000 ES in parallel its only need to connect the main inverter to batteries in parallel. The Growatt SPF 5000 ES parallel cable will get the needed data from the slave inverters.
how did you connect the pins in the plug on both sides?
Do you have the link for the CT meter?
Unfortunately no. I got the Charget and the clamp in one package and I cannot see any markings on it. But, I'm pretty sure that you can use any CT clamp for AC.
@@golden4o tc 2000:1
Hello, I got the Thor EV charger like yours now. My question is what is the spec of the CT that you use?
Hi, nice video. The clam you are showing on the minute 3:49 to check the power consume from the house, come by default with the charger, or do you need to buy that apart?can you send me the model of that?
You have to buy that separately. Any AC clamp should work (for the rated AMPs)
Hi
Hi, thanks for your videos. The EC charger works without wifi? This have Bluetooth too? I need to install the charger in a parking with no internet. Regards.
Thanks for the video! Is it possible to setup 3-phase system from the same 3 growatt inverters?
Yes. You can do that by changing the settings of the inverters.
@@golden4o thank you!
Zero Information here.
What order in the cable then aka Color order? Close picture on the cable head to see the colour order= Null modem? RJ45 head Write colour to the left nr2 colour etc due to missing the cable !
Hi, how does PV linkage work? Also load balancing, did it happen to shut down your fuzes?
I was unable to test the PV linkage. I need to get more sensors for 3 phase system. My main fuses are 63A and the one going to the charger is 50A so no issues there.
Thank you for your video, did you use 1 phase 7kw? Why 3 phases?
@@komjazz I have only one phase but it is splited on three conductors. No idea why I don't have 3phase input. So that's why I use single phase charger. In order to use pv linkage I have to monitor those three conductors.
Hi, thank you for your reply, i have SPF5000 like yours, would love to see how it works. So little information on the internet now. 🙏
Small hint: Energy cannot be saved. So if I want to boil my water, I always have to use the same amount of energy for one liter. Christian's method relies on a longer period of time with less power in order to be able to use the power provided by the PV as efficiently as possible - so consumption peaks are intercepted. In the end, the energy consumption should even be (slightly) higher due to the interposition of the dimmer, but it doesn't matter, since more efficient coverage by the PV system and therefore better use of the self-generated energy .......... .... 🌞 ................ Solar Mini PV Tip ... Winter & Camping. A boiler and other hungry electricity consumers can be infinitely dimmed using the "5000W dimmer". Ebay €7. I run 5 dimmers in parallel on an 850W inverter. Kettle 2.2KW at 150W runs 12 hours a day, so the water is always hot. The room is also nicely heated. 2.5KW washing machine runs in parallel with dimmed to 200...400W. Iron, dishwasher, oven, electric heater, coffee machine, all internal heating are throttled with me. Videos on my channel ruclips.net/video/eC2olbCBhh0/видео.html The inverter stays cool, quiet and the MOSFETs + (battery) remain intact because no extreme current peaks arrive at the inverter. Now every Mini PV Inverter is enough to sell large devices. So, with the dimmer, all internal heaters/devices can be converted into base load devices that stay almost permanently ON, drawing very little current directly from the PV. With a wattmeter / energy cost measuring device you can then measure this perfectly in order to optimally set the dimmer. With the dimmer, self-sufficiency will now increase from 20% to almost 95% in summer, which means a huge breakthrough. The prerequisite is that you have at least a small balcony power station, and you don’t need an expensive battery either. Example of a kettle: Without a dimmer, the 2500W - 600W PV system needs = 1900W, which you have to pay more for. If I turn the kettle down to 600W with a dimmer, then every weak PV system can now supply each consumer independently and independently, because the 2500W kettle becomes a 600W kettle thanks to the dimmer. Magic... The 2000W e-heater becomes a 500W e-heater with a dimmer, which can run 12 hours a day free of charge via PV. ruclips.net/video/QbLWDbJi6ew/видео.html . The 4000W oven is also tamed. Not the solar systems have to grow, but the consumers just have to drop by 75%, which is sooo easy with the dimmer. are you convinced now I have already switched my entire household to dimmers. Please have a look at my channel. LG, Christian ................................
Hello: I have 16 model: 3.2 v 280 Ah batteries along with “Overkill Solar” battery management system. I have cut the wood that I will be using to construct the bottom of my wooden frame to hold all 16 batteries. I would like to purchase battery tape to provide support to all 16 batteries and to secure the battery terminals. After I’ve connected each one of the BMS leads to the positive terminals which includes the black lead to the negative terminal and the red lead to the positive terminal, I’m not sure what battery wires and devices should I use to connect two Growatts 3,000 kilo watt inverters to the 16 batteries. Would you do a video on this or provide an answer on this? Regards, Gabriel L.
Those t-shirt change faster than the car :D